Mahmoud Khashaa Mohammed
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mahmoud Khashaa Mohammed has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Andrew Robert Dawson
Univ. of Nottingham
3 shared publications Nicholas Howard Thom
3 shared publications- Abdulkader Ismail Al-Hadithi
University of Anbar
2 shared publications Asmaa S. Hussien
2 shared publications- Yousif A. Mansoor
Civil Engineering Department, University of Anbar, Ramadi-Iraq
2 shared publications Abdulrahman S. Mohammed
Dams and water resources departement, College of Engineering, University of Anbar, Ramadi, Iraq
1 shared publication
Latest Publications
- 27 January 2026
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 11 (2) , 91
Optimization of waste brick and CKD powders as partial replacement of cement for sustainable self-compacting mortars SC-Ms
- 27 January 2026
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 11 (2) , 91
Optimization of waste brick and CKD powders as partial replacement of cement for sustainable self-compacting mortars SC-Ms
- Open Access
- 6 October 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (5) , 27908-27914
Sulfate Resistance and Microstructure Changes of Sustainable Self-Compacting Concrete Containing Micro to Nano Waste Materials
The concrete microstructure may change the resistance of concrete to the penetration of aggressive substances from the environment into the concrete body. Incorporating micro-to-nano waste materials, such as Limestone (LS), Fly Ash (FA), Glass Powder (GP) and Kaolin (K), can modify the concrete microstructure and increase its chemical resistance. This study investigated the use of four waste material formulations with different scales in medium-strength (at the range of 25-45 MPa) sustainable Self-Compacting Concrete (SCC), and its sulfate resistance and microstructural changes were studied. Ordinary Portland cement was replaced with 40% waste materials at the microscale, and 4% at the microscale to nanoscale. The analysis of the performed tests showed that the type and scale of the cement replacement material significantly affected the durability performance of SCC under magnesium sulfate exposure. In addition to the fresh properties, the flowability improved significantly with the use of waste materials at the microscale, while the passing and segregation resistances of microscale to nanoscale waste materials improved more than microscale replacement. The tests performed showed that 4% FA demonstrated a better mechanical performance and durability in a magnesium sulfate environment.
- 6 October 2025
- Published by Engineering, Technology & Applied Science Research in Engineering, Technology & Applied Science Research
- Vol. 15 (5) , 27908-27914
Open AccessSulfate Resistance and Microstructure Changes of Sustainable Self-Compacting Concrete Containing Micro to Nano Waste Materials
The concrete microstructure may change the resistance of concrete to the penetration of aggressive substances from the environment into the concrete body. Incorporating micro-to-nano waste materials, such as Limestone (LS), Fly Ash (FA), Glass Powder (GP) and Kaolin (K), can modify the concrete microstructure and increase its chemical resistance. This study investigated the use of four waste material formulations with different scales in medium-strength (at the range of 25-45 MPa) sustainable Self-Compacting Concrete (SCC), and its sulfate resistance and microstructural changes were studied. Ordinary Portland cement was replaced with 40% waste materials at the microscale, and 4% at the microscale to nanoscale. The analysis of the performed tests showed that the type and scale of the cement replacement material significantly affected the durability performance of SCC under magnesium sulfate exposure. In addition to the fresh properties, the flowability improved significantly with the use of waste materials at the microscale, while the passing and segregation resistances of microscale to nanoscale waste materials improved more than microscale replacement. The tests performed showed that 4% FA demonstrated a better mechanical performance and durability in a magnesium sulfate environment.
- Open Access
- 3 June 2024
- Published by Salud, Ciencia y Tecnologia in Salud, Ciencia y Tecnología - Serie de Conferencias
- Vol. 3, 831
Structural behaviors of different corroded RC members strengthened by different types of concrete jackets
Existing corroded reinforced concrete (RC) structures must be repaired and strengthened to extend their service life. Otherwise, they must be demolished and rebuilt. In general, repair and strengthening are more cost-effective than demolition and reconstruction. This research assessed the performance of corrosion-damaged reinforced concrete beams and columns strengthened with different types of concrete. The corrosion rate of reinforcing columns and beams was assumed to be 10% using accelerating electrochemical corrosion method. After steel corrosion, the surface of concrete members is roughened by sandblasting; it was then strengthened with different types of concrete: self-compacting concrete (SCC), fiber-reinforced self-compacting concrete (FRSCC), high-performance concrete (HPC), fiber-reinforced high-performance concrete (FRHPC), and fiber reinforced normal concrete (FRNC). Before and after corrosion, the flexural and compression tests were carried out for the beams and columns, respectively. Experimental findings demonstrated that the bearing and axial compression capacities of beams and columns were reduced considerably. due to the corrosion of reinforcements, and concrete jackets from different types of used concrete could efficiently restore the damage resulting from corroded steel rods. The study concludes that the use different types of concrete are suitable for the external strengthening of corroded RC members. However, for flexure, the strengthen concrete beam that achieved the highest increase in flexural and ductility is the one strengthens by 30 mm FRHPC jacket (8.65%). For axial compression, strengthen concrete column that achieved the highest increase is that strengths with 30 mm of FRSCC (136.78%). Las estructuras de hormigón armado corroídas deben repararse y reforzarse para prolongar su vida útil. En caso contrario, deben ser demolidas y reconstruidas. En general, la reparación y el refuerzo son más rentables que la demolición y la reconstrucción. Esta investigación evaluó el comportamiento de vigas y pilares de hormigón armado dañados por la corrosión y reforzados con diferentes tipos de hormigón. La tasa de corrosión de los pilares y vigas reforzados se supuso del 10% utilizando el método de corrosión electroquímica acelerada. Tras la corrosión del acero, la superficie de los elementos de hormigón se desbastó mediante chorro de arena; a continuación, se reforzaron con diferentes tipos de hormigón: hormigón autocompactante (SCC), hormigón autocompactante reforzado con fibras (FRSCC), hormigón de altas prestaciones (HPC), hormigón de altas prestaciones reforzado con fibras (FRHPC) y hormigón normal reforzado con fibras (FRNC). Antes y después de la corrosión, se realizaron ensayos de flexión y compresión para las vigas y los pilares, respectivamente. Los resultados experimentales demostraron que las capacidades portante y de compresión axial de vigas y pilares se reducían considerablemente debido a la corrosión de las armaduras, y que las camisas de hormigón de diferentes tipos de hormigón utilizado podían restaurar eficazmente los daños resultantes de las varillas de acero corroídas. El estudio concluye que el uso de diferentes tipos de hormigón es adecuado para el refuerzo externo de elementos de CR corroídos. Sin embargo, para la flexión, la viga de hormigón reforzado que logró el mayor aumento en la flexión y la ductilidad es la reforzada por 30 mm de revestimiento FRHPC (8,65%). Para compresión axial, la columna de hormigón armado que alcanzó el mayor incremento es la reforzada con 30 mm de FRSCC (136.78%).
- 3 June 2024
- Published by Salud, Ciencia y Tecnologia in Salud, Ciencia y Tecnología - Serie de Conferencias
- Vol. 3, 831
Open AccessStructural behaviors of different corroded RC members strengthened by different types of concrete jackets
Existing corroded reinforced concrete (RC) structures must be repaired and strengthened to extend their service life. Otherwise, they must be demolished and rebuilt. In general, repair and strengthening are more cost-effective than demolition and reconstruction. This research assessed the performance of corrosion-damaged reinforced concrete beams and columns strengthened with different types of concrete. The corrosion rate of reinforcing columns and beams was assumed to be 10% using accelerating electrochemical corrosion method. After steel corrosion, the surface of concrete members is roughened by sandblasting; it was then strengthened with different types of concrete: self-compacting concrete (SCC), fiber-reinforced self-compacting concrete (FRSCC), high-performance concrete (HPC), fiber-reinforced high-performance concrete (FRHPC), and fiber reinforced normal concrete (FRNC). Before and after corrosion, the flexural and compression tests were carried out for the beams and columns, respectively. Experimental findings demonstrated that the bearing and axial compression capacities of beams and columns were reduced considerably. due to the corrosion of reinforcements, and concrete jackets from different types of used concrete could efficiently restore the damage resulting from corroded steel rods. The study concludes that the use different types of concrete are suitable for the external strengthening of corroded RC members. However, for flexure, the strengthen concrete beam that achieved the highest increase in flexural and ductility is the one strengthens by 30 mm FRHPC jacket (8.65%). For axial compression, strengthen concrete column that achieved the highest increase is that strengths with 30 mm of FRSCC (136.78%). Las estructuras de hormigón armado corroídas deben repararse y reforzarse para prolongar su vida útil. En caso contrario, deben ser demolidas y reconstruidas. En general, la reparación y el refuerzo son más rentables que la demolición y la reconstrucción. Esta investigación evaluó el comportamiento de vigas y pilares de hormigón armado dañados por la corrosión y reforzados con diferentes tipos de hormigón. La tasa de corrosión de los pilares y vigas reforzados se supuso del 10% utilizando el método de corrosión electroquímica acelerada. Tras la corrosión del acero, la superficie de los elementos de hormigón se desbastó mediante chorro de arena; a continuación, se reforzaron con diferentes tipos de hormigón: hormigón autocompactante (SCC), hormigón autocompactante reforzado con fibras (FRSCC), hormigón de altas prestaciones (HPC), hormigón de altas prestaciones reforzado con fibras (FRHPC) y hormigón normal reforzado con fibras (FRNC). Antes y después de la corrosión, se realizaron ensayos de flexión y compresión para las vigas y los pilares, respectivamente. Los resultados experimentales demostraron que las capacidades portante y de compresión axial de vigas y pilares se reducían considerablemente debido a la corrosión de las armaduras, y que las camisas de hormigón de diferentes tipos de hormigón utilizado podían restaurar eficazmente los daños resultantes de las varillas de acero corroídas. El estudio concluye que el uso de diferentes tipos de hormigón es adecuado para el refuerzo externo de elementos de CR corroídos. Sin embargo, para la flexión, la viga de hormigón reforzado que logró el mayor aumento en la flexión y la ductilidad es la reforzada por 30 mm de revestimiento FRHPC (8,65%). Para compresión axial, la columna de hormigón armado que alcanzó el mayor incremento es la reforzada con 30 mm de FRSCC (136.78%).
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3009 (1)
Optimization of different types of self-compacting concrete mixes for strengthening purposes
This article presents an optimization of percentages of cement replacement materials in a filler-typed self- compacting concrete SCC. This is to obtain adequate fresh properties and desired compressive strength for strengthening purposes. This has been done using experimental results and statistical analysis. Different types of cement replacement materials were considered for SCC mixes, divided into four groups. Fly ash replacements in the first group were 10, 20, and 30% by weight of cement, and the same percentages for limestone powder in the second group. The third group consists of a combination of fly ash and silica fume at the same ratios, while silica fume was added at 8, 10, and 12 % in the fourth group. Different tests were applied to assess the properties such as slump flow, T500, L-box, sieve stability test, and compressive strength as a main hardened property. By optimizing experimental results in Minitab software, tests and statistical results indicated the closeness of results of the theoretical optimization with experimental results and the best SCC mix that could be used for strengthening purposes is that contains mixed fly ash and silica fume at a percent of 18% as partial replacement of cement.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3009 (1)
Open AccessOptimization of different types of self-compacting concrete mixes for strengthening purposes
This article presents an optimization of percentages of cement replacement materials in a filler-typed self- compacting concrete SCC. This is to obtain adequate fresh properties and desired compressive strength for strengthening purposes. This has been done using experimental results and statistical analysis. Different types of cement replacement materials were considered for SCC mixes, divided into four groups. Fly ash replacements in the first group were 10, 20, and 30% by weight of cement, and the same percentages for limestone powder in the second group. The third group consists of a combination of fly ash and silica fume at the same ratios, while silica fume was added at 8, 10, and 12 % in the fourth group. Different tests were applied to assess the properties such as slump flow, T500, L-box, sieve stability test, and compressive strength as a main hardened property. By optimizing experimental results in Minitab software, tests and statistical results indicated the closeness of results of the theoretical optimization with experimental results and the best SCC mix that could be used for strengthening purposes is that contains mixed fly ash and silica fume at a percent of 18% as partial replacement of cement.
- Open Access
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3009 (1)
Porosity and strength of self-compacting concrete incorporating waste plastic as: Fibers and fine aggregate
This study aims to investigate the impact of incorporating recycled Polyethylene Terephthalate plastic on porosity and compressive strength of the self-compacting concrete and the relation between them. This is by using the Polyethylene Terephthalate as fibers and as fine aggregate replacement. Five proportions were used for each type of Polyethylene Terephthalate (0.25, 0.5, 0.75, 1.0, and 1.25) % as volume fractions for fiber addition of the mix total volume and (2, 4, 6, 8, and 10) % by volume as replacements of sand with fine Polyethylene Terephthalate. All mixes were compared with a reference self-compacting concrete mix that has no Polyethylene Terephthalate. The porosity showed a notable increase for all proportions of the two types of Polyethylene Terephthalate but the self-compacting concrete mixes containing fine Polyethylene Terephthalate showed higher values than mixes with the fiber-Polyethylene Terephthalate. As for the 28-day compressive strength, it showed a decrease in all mixes compared with the reference mix. As for the same type of Polyethylene Terephthalate there was no constant changing among the mixes whether they all rise or fall in values. The same is for porosity. The result obtained from correlation coefficient revealed that there is an inversely weak relation between porosity and compressive strength.
- 1 January 2024
- Published by AIP Publishing in AIP Conference Proceedings
- Vol. 3009 (1)
Open AccessPorosity and strength of self-compacting concrete incorporating waste plastic as: Fibers and fine aggregate
This study aims to investigate the impact of incorporating recycled Polyethylene Terephthalate plastic on porosity and compressive strength of the self-compacting concrete and the relation between them. This is by using the Polyethylene Terephthalate as fibers and as fine aggregate replacement. Five proportions were used for each type of Polyethylene Terephthalate (0.25, 0.5, 0.75, 1.0, and 1.25) % as volume fractions for fiber addition of the mix total volume and (2, 4, 6, 8, and 10) % by volume as replacements of sand with fine Polyethylene Terephthalate. All mixes were compared with a reference self-compacting concrete mix that has no Polyethylene Terephthalate. The porosity showed a notable increase for all proportions of the two types of Polyethylene Terephthalate but the self-compacting concrete mixes containing fine Polyethylene Terephthalate showed higher values than mixes with the fiber-Polyethylene Terephthalate. As for the 28-day compressive strength, it showed a decrease in all mixes compared with the reference mix. As for the same type of Polyethylene Terephthalate there was no constant changing among the mixes whether they all rise or fall in values. The same is for porosity. The result obtained from correlation coefficient revealed that there is an inversely weak relation between porosity and compressive strength.
- 19 September 2023
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 8 (10) , 1-24
Fresh, mechanical and impact properties of self-compacting lightweight concrete containing waste PET fibers
- 19 September 2023
- Published by Springer Nature in Innovative Infrastructure Solutions
- Vol. 8 (10) , 1-24
Fresh, mechanical and impact properties of self-compacting lightweight concrete containing waste PET fibers
- Open Access
- 21 October 2022
- Published by University of Anbar in Anbar Journal of Engineering Sciences
- Vol. 13 (1) , 23-34
Properties of Sustainable Self- compacting Concrete Containing Treated and Modified Waste Plastic Fibers
This study aims to improve different properties of sustainable self-compacting concrete SCC containing treated and modified polyethylene terephthalate PET fibers. For this purpose, gamma ray surface treatment and geometric modification were utilized for the used PET fibers. Concrete fresh properties include slump flow, T500mm, L-box and sieve segregation while mechanical properties include compressive, split tensile strength, flexural strength, static modulus of elasticity and impact strength. Further, physical properties and related durability properties comprise dry density, ultrasonic pulse velocity, porosity and water absorption. The results obtained demonstrated that the treatment and the modification used for the PET fibers slightly reduced the fresh properties of produced sustainable SCC (slump flow, T500 mm, L-Box and sieve segregation). However, they were within the limits of the SCC specification as reported in EFNERC guidelines. Further, concrete hardened properties in terms of compressive strength, splitting tensile strength, flexural strength, modulus of elasticity, impact strength, ultrasonic pulse velocity, decrease in the dry density, decrease in porosity and water absorption increased significantly.
- 21 October 2022
- Published by University of Anbar in Anbar Journal of Engineering Sciences
- Vol. 13 (1) , 23-34
Open AccessProperties of Sustainable Self- compacting Concrete Containing Treated and Modified Waste Plastic Fibers
This study aims to improve different properties of sustainable self-compacting concrete SCC containing treated and modified polyethylene terephthalate PET fibers. For this purpose, gamma ray surface treatment and geometric modification were utilized for the used PET fibers. Concrete fresh properties include slump flow, T500mm, L-box and sieve segregation while mechanical properties include compressive, split tensile strength, flexural strength, static modulus of elasticity and impact strength. Further, physical properties and related durability properties comprise dry density, ultrasonic pulse velocity, porosity and water absorption. The results obtained demonstrated that the treatment and the modification used for the PET fibers slightly reduced the fresh properties of produced sustainable SCC (slump flow, T500 mm, L-Box and sieve segregation). However, they were within the limits of the SCC specification as reported in EFNERC guidelines. Further, concrete hardened properties in terms of compressive strength, splitting tensile strength, flexural strength, modulus of elasticity, impact strength, ultrasonic pulse velocity, decrease in the dry density, decrease in porosity and water absorption increased significantly.
- 11 September 2022
- Published by Taylor & Francis in European Journal of Environmental and Civil Engineering
- Vol. 27 (9) , 2967-2984
Optimum characteristics of plastic fibres for sustainable self-compacting concrete SCC
The main aim of this research is to optimize various characteristics of Polyethylene terephthalate PET fibres in a sustainable self-compacting concrete in terms of volume fraction Vf, aspect ratio Ar and method of surface treatment. In the first stage, the performance of fibre-reinforced self-compacting concrete was analysed in terms of main fresh and hardened properties. Nine different SCC mixtures were designed using three different ratios of Vf and Ar. The fresh tests were evaluated through the examination of the slump flow and T500 while the hardened tests include compressive and splitting tensile strength test. The optimal mixture was selected based on a statistical program (Minitab19) for the next stage. The optimized mix in stage two is selected to be a control mix in addition to other two mixtures with PET fibres treated chemically (NaOH solution), and mechanically (surface roughness). The fresh tests in this stage include slump flow, T500mm, L-box, sieve segregation whereas the hardened tests include compressive, splitting tensile, flexural, impact strength, porosity, and water absorption. The multi-objective optimization results from first stage indicated that the optimum Vf and Ar for PET fibres, to achieve the optimum performance in terms of the tested properties and the partitioning of sustainability aspects, were 0.7% and 24.4 respectively. The results of the two modifications used for PET fibres reduced the fresh properties slightly (flow, L-box, T500, sieve segregation) yet they were within the specification limits for SCC. However, the mechanical and related durability properties (strength, tensile, flexural, impact, less porosity, less absorption) were increased considerably. It can be deduced that treatment of PET fibres by increasing the roughness surface with the optimum characteristics of PET fibres from stage one, in terms Vf and Ar, can give the best performance.
- 11 September 2022
- Published by Taylor & Francis in European Journal of Environmental and Civil Engineering
- Vol. 27 (9) , 2967-2984
Optimum characteristics of plastic fibres for sustainable self-compacting concrete SCC
The main aim of this research is to optimize various characteristics of Polyethylene terephthalate PET fibres in a sustainable self-compacting concrete in terms of volume fraction Vf, aspect ratio Ar and method of surface treatment. In the first stage, the performance of fibre-reinforced self-compacting concrete was analysed in terms of main fresh and hardened properties. Nine different SCC mixtures were designed using three different ratios of Vf and Ar. The fresh tests were evaluated through the examination of the slump flow and T500 while the hardened tests include compressive and splitting tensile strength test. The optimal mixture was selected based on a statistical program (Minitab19) for the next stage. The optimized mix in stage two is selected to be a control mix in addition to other two mixtures with PET fibres treated chemically (NaOH solution), and mechanically (surface roughness). The fresh tests in this stage include slump flow, T500mm, L-box, sieve segregation whereas the hardened tests include compressive, splitting tensile, flexural, impact strength, porosity, and water absorption. The multi-objective optimization results from first stage indicated that the optimum Vf and Ar for PET fibres, to achieve the optimum performance in terms of the tested properties and the partitioning of sustainability aspects, were 0.7% and 24.4 respectively. The results of the two modifications used for PET fibres reduced the fresh properties slightly (flow, L-box, T500, sieve segregation) yet they were within the specification limits for SCC. However, the mechanical and related durability properties (strength, tensile, flexural, impact, less porosity, less absorption) were increased considerably. It can be deduced that treatment of PET fibres by increasing the roughness surface with the optimum characteristics of PET fibres from stage one, in terms Vf and Ar, can give the best performance.
- Open Access
- 1 November 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 928 (2) , 022140
Optimization of glass powder content in self-compacting concrete as partial replacement of cement
The main aim of the present work is to investigate the fresh and hardened properties of self-compacting concrete by utilization recycled glass powder as partial replacement material for cement and to specify the optimum percent from performance and sustainability point of views. In this study, five mixes were designed with different percentage of grinded glass powder used as cement replacement at 0%, 10%, 20%, 30%, and 40% by weight. Slump flow diameter, time needed to achieve a flow diameter of 500 mm, sieve segregation resistance and L-box height ratio were utilized to examine the rheological properties of the produced self-compacting concrete. For the main mechanical properties, compressive strength at 7, 28, 56 days, splitting tensile, and flexural strengths test at 28 day were conducted. The test results illustrate that the increase in the partial replacement of cement by glass powder led to keep flow ability and caused small decrease in T500 mmtime. However, there was slight decrease in the passing ability and better performance in segregation resistance compared to the mix without glass powder. The mechanical properties of the produced mixes increased up to the replacement level of 30%. However, the optimization results using Minitab 18 statistical software deduced that the optimum percent is 24% to achieve optimum performance in terms tested properties and evaluated sustainability aspects.
- 1 November 2020
- Published by IOP Publishing in IOP Conference Series: Materials Science and Engineering
- Vol. 928 (2) , 022140
Open AccessOptimization of glass powder content in self-compacting concrete as partial replacement of cement
The main aim of the present work is to investigate the fresh and hardened properties of self-compacting concrete by utilization recycled glass powder as partial replacement material for cement and to specify the optimum percent from performance and sustainability point of views. In this study, five mixes were designed with different percentage of grinded glass powder used as cement replacement at 0%, 10%, 20%, 30%, and 40% by weight. Slump flow diameter, time needed to achieve a flow diameter of 500 mm, sieve segregation resistance and L-box height ratio were utilized to examine the rheological properties of the produced self-compacting concrete. For the main mechanical properties, compressive strength at 7, 28, 56 days, splitting tensile, and flexural strengths test at 28 day were conducted. The test results illustrate that the increase in the partial replacement of cement by glass powder led to keep flow ability and caused small decrease in T500 mmtime. However, there was slight decrease in the passing ability and better performance in segregation resistance compared to the mix without glass powder. The mechanical properties of the produced mixes increased up to the replacement level of 30%. However, the optimization results using Minitab 18 statistical software deduced that the optimum percent is 24% to achieve optimum performance in terms tested properties and evaluated sustainability aspects.
- 1 February 2019
- Published by Elsevier in Construction and Building Materials
- Vol. 197, 734-746
Production and optimization of eco-efficient self compacting concrete SCC with limestone and PET
- 1 February 2019
- Published by Elsevier in Construction and Building Materials
- Vol. 197, 734-746
Production and optimization of eco-efficient self compacting concrete SCC with limestone and PET