Steve S. Kraman

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Steve S. Kraman has a total of 8 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Smart Devices Are Poised to Revolutionize the Usefulness of Respiratory Sounds

    by Steve S. Kraman, Hans Pasterkamp, George R. Wodicka


  • The Ins and Outs of Respiration

    by Steve Kraman

    The single-breath carbon monoxide diffusing capacity (Dl,co) is commonly used to test the function of the alveolar capillary membrane (A–C) and is an important test in the evaluation of diseases that destroy or thicken the A–C membrane. However, the test result can easily be affected by nonmembrane related factors, such as hemoglobin concentration, recent smoking, airway diseases, and vascular abnormalities. Adjustments can be made for some of these factors but not others. In the latter case, reasonable interpretation may be impossible.

  • Lesser Used Tests of Pulmonary Function: Compliance, Resistance and Dead Space

    by Steve Kraman

    The measurements of lung compliance, airway resistance and respiratory dead space as clinical tests have gradually fallen into disuse as the standard pulmonary function testing procedures; spirometry, lung volume and diffusing capacity measurement, followed, if necessary, by imaging have become the norm for diagnosis of COPD and other lung diseases. To have a real understanding of what spirometry and lung volume tests measure requires some knowledge of compliance and airway resistance. The respiratory dead space is an important global indicator of ventilation/perfusion relationships that remains of interest in the early detection of pulmonary emboli. There are other situations as well where it is clinically useful to perform the measurements described here, so these techniques, although generally set aside from the commonly used tests, should not be forgotten.


  • Transmission of Lung Sounds through Light Clothing

    by Steve S. Kraman

    Background: Doctors are exhorted to always place the stethoscope directly on the skin and never to auscultate through clothing. Nevertheless, casual observation reveals that doctors and even pulmonologists often violate this principle. Objectives: This study was designed to evaluate the sensitivity of two common stethoscopes when used through clothing. Methods: Littmann Classic and Littmann Master Cardiology stethoscopes were studied under conditions of light (60–100 g), medium (240 g) and heavy (555 g) force when placed on a lung sound test platform with one or two layers of cloth (T-shirt material and flannel) interposed between the stethoscope and the test surface. The test platform was designed to mimic the acoustic and mechanical properties of the chest wall and was driven by amplified white noise. The recorded amplitude spectra were compared over a range of 150–1,000 Hz. Results: Compared to the sensitivity on a bare test platform surface, either fabric in single or double layers attenuated the sounds by a mean of 5–18 dB under light pressure. This attenuation was nearly abolished by the addition of either medium or heavy force on the stethoscope head. Conclusions: The deleterious effect of one or two layers of indoor clothing on lung sounds acquired through a stethoscope can be negated by force on the stethoscope head making effective auscultation possible. Nevertheless, auscultation through clothing remains problematic due to the hindrance to inspection and percussion and the risk of acoustic artifacts caused by clothing.


  • Comparison of lung sound transducers using a bioacoustic transducer testing system

    by Steve S. Kraman, George R. Wodicka, Gary A. Pressler, Hans Pasterkamp

    Sensors used for lung sound research are generally designed by the investigators or adapted from devices used in related fields. Their relative characteristics have never been defined. We employed an artificial chest wall with a viscoelastic surface and a white noise signal generator as a stable source of sound to compare the frequency response and pulse waveform reproduction of a selection of devices used for lung sound research. We used spectral estimation techniques to determine frequency response and cross-correlation of pulses to determine pulse shape fidelity. The sensors evaluated were the Siemens EMT 25 C accelerometer (Siemens); PPG 201 accelerometer (PPG); Sony ECM-T150 electret condenser microphone with air coupler (air coupler; with cylindrical air chambers of 5-, 10-, and 15-mm diameter and conical air chamber of 10-mm diameter); Littman classic stethoscope head (Littman) connected to an electret condenser microphone; and the Andries Tek (Andries) electronic stethoscope. We found that the size and shape of the air coupler chamber to have no important effect on the detected sound. The Siemens, air coupler, and Littman performed similarly with relatively flat frequency responses from 200 to 1,200 Hz. The PPG had the broadest frequency response, with useful sensitivity extending to 4,000 Hz. The Andries' frequency response was the poorest above 1,000 Hz. Accuracy in reproducing pulses roughly corresponded with the high-frequency sensitivity of the sensors. We conclude that there are important differences among commonly used lung sound sensors that have to be defined to allow the comparison of data from different laboratories.


    • 11 June 2002
      • Vol. 36  (3) , 177-82

    Are minidisc recorders adequate for the study of respiratory sounds?

    by Steve S Kraman, George R Wodicka, Hiroshi Kiyokawa, Hans Pasterkamp

    Digital audio tape (DAT) recorders have become the de facto gold standard recording devices for lung sounds. Sound recorded on DAT is compact-disk (CD) quality with adequate sensitivity from below 20 Hz to above 20 KHz. However, DAT recorders have drawbacks. Although small, they are relatively heavy, the recording mechanism is complex and delicate, and finding one desired track out of many is inconvenient. A more recent development in portable recording devices is the minidisc (MD) recorder. These recorders are widely available, inexpensive, small and light, rugged, mechanically simple, and record digital data in tracks that may be named and accessed directly. Minidiscs hold as much recorded sound as a compact disk but in about 1/5 of the recordable area. The data compression is achieved by use of a technique known as adaptive transform acoustic coding for minidisc (ATRAC). This coding technique makes decisions about what components of the sound would not be heard by a human listener and discards the digital information that represents these sounds. Most of this compression takes place on sounds above 5.5 KHz. As the intended use of these recorders is the storage and reproduction of music, it is unknown whether ATRAC will discard or distort significant portions of typical lung sound signals. We determined the suitability of MD recorders for respiratory sound research by comparing a variety of normal and pathologic lung sounds that were digitized directly into a computer and also after recording by a DAT recorder and 2 different MD recorders (Sharp and Sony). We found that the frequency spectra and waveforms of respiratory sounds were not distorted in any important way by recording on the two MD recorders tested.

  • ‘Slide whistle’ breath sounds: acoustical correlates of variable tracheal obstruction

    by Steve S Kraman, Paul Harper, Hans Pasterkamp, George R Wodicka

    We report a case of a man who developed severe shortness of breath and the finding of breath sounds that rose in frequency during inspiration and fell during expiration. These unusual sounds were caused by a spherical tumour arising from the main carina that nearly completely obstructed the distal trachea. The frequency variation disappeared after the removal of the mass. We evaluated this phenomenon using a modelling technique that we had previously developed to analyse the human airways as acoustical tubes. This analysis revealed that the acoustical conditions in the trachea were substantially modified by the presence of the solid mass as the trachea slightly dilated during inspiration, partially relieving the obstruction. Most of the anomalous characteristics of the breath sounds could be explained using this model. We conclude that a detailed understanding of the acoustic conditions of the airways allows correlation with anatomical and physiological conditions and may be of use in diagnosis or evaluation of the airways in health and disease.