Aldair Wontroba
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Aldair Wontroba has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Adriano Peres de Morais
Federal University of Santa Maria , Santa Maria , Brazil
3 shared publications - Ghendy Cardoso
Laboratory for Analysis and Protection of Electrical Systems, Federal University of Santa Maria, Santa Maria, Brazil
3 shared publications Jean Pereira Rossini
Univ Fed Santa Maria, Dept Elect Engn, Santa Maria, Rio Grande do S, Brazil
3 shared publicationsPatrick Escalante Farias
Fed Inst Rio Grande do Sul, Farroupilha, Rio Grande do S, Brazil
3 shared publicationsJoão Paulo Abreu Vieira
Fed Univ Para, Dept Elect Engn, Belem, Para, Brazil
2 shared publications- João Paulo Abreu Vieira
Grupo de Sistemas de Energia Elétrica e Inovação (GSEI), Programa de Pós-Graduação em Engenharia Elétrica (PPGEE), Universidade Federal do Pará (UFPA), Belém 66075-110, PA, Brazil
2 shared publications
Latest Publications
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (6) , 3382-3389
An Artificial Intelligence Framework for Vegetation Identification in Overhead Distribution Networks Using the IEC 61850 Standard
The identification of vegetation contact with the power grid is a critical issue for utilities, posing significant risks to the population. Undetected events can lead to system failures, such as short circuits, outages, cable degradation, and environmental hazards, including large-scale wildfires. Vegetation pruning near distribution networks is common but costly due to the difficulty of covering extensive areas. The low current magnitudes from these events, known as vegetation high-impedance faults, often require high-frequency components for detection. However, high-frequency signal acquisition technologies are expensive and impractical for widespread deployment, prompting alternative methods for identification and vegetation management. This study proposes a practical and reliable framework for detecting vegetation contact with the distribution grid. It employs IEC 61850 standard and extended time-window analysis, capturing up to one minute of neutral current signals. These signals are processed by an AI algorithm that classifies events and delivers results. The proposed framework was tested in one feeder on real-time simulation but it is scalable to all substation feeders using technology of centralized protection. The approach achieved 95% accuracy and a false positive rate below 1% .
- 18 September 2025
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 40 (6) , 3382-3389
An Artificial Intelligence Framework for Vegetation Identification in Overhead Distribution Networks Using the IEC 61850 Standard
The identification of vegetation contact with the power grid is a critical issue for utilities, posing significant risks to the population. Undetected events can lead to system failures, such as short circuits, outages, cable degradation, and environmental hazards, including large-scale wildfires. Vegetation pruning near distribution networks is common but costly due to the difficulty of covering extensive areas. The low current magnitudes from these events, known as vegetation high-impedance faults, often require high-frequency components for detection. However, high-frequency signal acquisition technologies are expensive and impractical for widespread deployment, prompting alternative methods for identification and vegetation management. This study proposes a practical and reliable framework for detecting vegetation contact with the distribution grid. It employs IEC 61850 standard and extended time-window analysis, capturing up to one minute of neutral current signals. These signals are processed by an AI algorithm that classifies events and delivers results. The proposed framework was tested in one feeder on real-time simulation but it is scalable to all substation feeders using technology of centralized protection. The approach achieved 95% accuracy and a false positive rate below 1% .
- 26 June 2022
- Published by Elsevier in Electric Power Systems Research
- Vol. 211
High-impedance fault detection on downed conductor in overhead distribution networks
- 26 June 2022
- Published by Elsevier in Electric Power Systems Research
- Vol. 211
High-impedance fault detection on downed conductor in overhead distribution networks
- Open Access
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
High-Impedance Fault Detection on Downed Conductor in Overhead Distribution Networks
High impedance faults (HIF) may occur in the medium voltage distribution systems and constitute a danger to human beings. Many cases of high impedance faults are caused due to downed power cables in the distribution network. In this paper, a methodology for detecting HIF, generated by cable breakage, is presented. The algorithm is based on the analysis of the harmonic and symmetrical components of the current. The method is validated by means of real-time digital simulations and hardware implementation (hardware-in-the-loop concept). A distribution system based on a real feeder is used in the simulations, as well as two notable HIF models. Different soil configurations are used in the simulations, as well as different cases of broken cables that can occur in a real scenario. The results show that the proposed methodology has presented the performance under different types of HIF, models of HIF, and achieved a general accuracy of 90% and security of 100% for the tests performed. Even so, it employs common mathematical tools, such as symmetrical components and Fast Fourier Transform. Therefore, it is easy to implement it in actual Intelligent Electronic Devices (IEDs).
- 1 January 2022
- Published by Elsevier in SSRN Electronic Journal
Open AccessHigh-Impedance Fault Detection on Downed Conductor in Overhead Distribution Networks
High impedance faults (HIF) may occur in the medium voltage distribution systems and constitute a danger to human beings. Many cases of high impedance faults are caused due to downed power cables in the distribution network. In this paper, a methodology for detecting HIF, generated by cable breakage, is presented. The algorithm is based on the analysis of the harmonic and symmetrical components of the current. The method is validated by means of real-time digital simulations and hardware implementation (hardware-in-the-loop concept). A distribution system based on a real feeder is used in the simulations, as well as two notable HIF models. Different soil configurations are used in the simulations, as well as different cases of broken cables that can occur in a real scenario. The results show that the proposed methodology has presented the performance under different types of HIF, models of HIF, and achieved a general accuracy of 90% and security of 100% for the tests performed. Even so, it employs common mathematical tools, such as symmetrical components and Fast Fourier Transform. Therefore, it is easy to implement it in actual Intelligent Electronic Devices (IEDs).
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 6432-6437
Comprehensive High Impedance Fault Model for Real-Time Environment
This paper presents a comprehensive high impedance fault model for real-time environment. This model offers different types of ground surface and high impedance faults. Experimental results show that it is suitable for relays and algorithms commissioning in closed loop environment. The model is incorporated into OPAL-RT simulator and implemented in Hypersim software. Finally, the performance of the model is validated under a real case of high impedance fault by comparison with real-time simulation.
- 1 October 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 6432-6437
Comprehensive High Impedance Fault Model for Real-Time Environment
This paper presents a comprehensive high impedance fault model for real-time environment. This model offers different types of ground surface and high impedance faults. Experimental results show that it is suitable for relays and algorithms commissioning in closed loop environment. The model is incorporated into OPAL-RT simulator and implemented in Hypersim software. Finally, the performance of the model is validated under a real case of high impedance fault by comparison with real-time simulation.