Jingjie Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jingjie Wang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:
- Tianyou Luo
Department of Radiology, The First Affiliated Hospital of Chongqing Medical University , Chongqing
3 shared publications - Yongmei Li
Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, China
3 shared publications Jiajing Wu
2 shared publications- Jiajing Wu
Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuzhong District, Chongqing 400016, China
2 shared publications Jiayang Liu
2 shared publications- Jiayang Liu
Department of Radiology, The First Affiliated Hospital of Chongqing Medical University, No. 1 Youyi Road, Yuzhong District, Chongqing 400016, China
2 shared publications
Latest Publications
- Open Access
- 1 April 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (4) , 2865-2880
Unfavorable venous outflow correlates with poor prognosis in acute ischemic stroke due to large vessel occlusion (AIS-LVO) patients assessed dynamically and quantitatively based on four-dimensional computed tomography angiography/perfusion (4D-CTA/CTP)
Background: The condition of cerebral venous outflow (VO) and tissue level collaterals (TLC) can indirectly reflect cerebral microvascular perfusion in patients with acute ischemic stroke due to large vessel occlusion (AIS-LVO). This study aimed to investigate the association among VO, TLC, and long-term functional prognosis based on four-dimensional computed tomography angiography/perfusion (4D-CTA/CTP); and to compare the predictive value of different VO indicators for poor outcome. Methods: Enrolled AIS-LVO patients were categorized into good and poor outcome groups based on 90-day modified Rankin Scale (mRS) score, and they all underwent 4D-CTA/CTP examination at baseline. Veins were evaluated by three indicators: (I) four-dimensional cortical venous collaterals score (4D-VCS); (II) combined indicators of velocity and extent. Nine combined indicators were obtained according to the combination of velocity (Fast or Slow), and extent (Good or Poor), which were divided into three categories: favorable, moderate, and unfavorable; (III) cortical vein opacification score (COVES) at the venous phase. TLC was evaluated according to the hypoperfusion intensity ratio (HIR). Mann-Whitney U test or Chi-squared test was used to compare indicators between groups. Binary logistic regression analysis was used to explore the relationship between vein indicators and prognosis, and combined the vein indicators, TLC, and clinical indicators to establish 11 multivariable models. At last, the receiver operating characteristic (ROC) curve performance was compared by DeLong test. Results: A total of 172 patients were included. Compared with good outcome group, patients of poor outcome group showed advanced age {73.137±11.020 years old; 76 [interquartile range (IQR), 66–81] years old}, higher National Institutes of Health Stroke Scale (NIHSS) [12.34±6.308; 12 (IQR, 8–16)], lower 4D-VCS [5.67±3.988; 5 (IQR, 3–8)], lower COVES [3.088±1.904; 3 (IQR, 2–5)], Slow1 + Poor and Slow2 + Poor. The results of binary logistic regression analysis showed that the advanced age and high NIHSS were independent predictors for poor outcome in all 11 models (PConclusions: The three evaluation indicators of VO based on 4D-CTA/CTP can independently predict the long-term functional prognosis of AIS-LVO patients, and 4D-VCS had relatively higher predictive value. In the prognosis prediction of AIS-LVO patients, the combined model including 4D-VCS, clinical indicators, and TLC was superior to the model which only included clinical indicators.
- 1 April 2025
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 15 (4) , 2865-2880
Open AccessUnfavorable venous outflow correlates with poor prognosis in acute ischemic stroke due to large vessel occlusion (AIS-LVO) patients assessed dynamically and quantitatively based on four-dimensional computed tomography angiography/perfusion (4D-CTA/CTP)
Background: The condition of cerebral venous outflow (VO) and tissue level collaterals (TLC) can indirectly reflect cerebral microvascular perfusion in patients with acute ischemic stroke due to large vessel occlusion (AIS-LVO). This study aimed to investigate the association among VO, TLC, and long-term functional prognosis based on four-dimensional computed tomography angiography/perfusion (4D-CTA/CTP); and to compare the predictive value of different VO indicators for poor outcome. Methods: Enrolled AIS-LVO patients were categorized into good and poor outcome groups based on 90-day modified Rankin Scale (mRS) score, and they all underwent 4D-CTA/CTP examination at baseline. Veins were evaluated by three indicators: (I) four-dimensional cortical venous collaterals score (4D-VCS); (II) combined indicators of velocity and extent. Nine combined indicators were obtained according to the combination of velocity (Fast or Slow), and extent (Good or Poor), which were divided into three categories: favorable, moderate, and unfavorable; (III) cortical vein opacification score (COVES) at the venous phase. TLC was evaluated according to the hypoperfusion intensity ratio (HIR). Mann-Whitney U test or Chi-squared test was used to compare indicators between groups. Binary logistic regression analysis was used to explore the relationship between vein indicators and prognosis, and combined the vein indicators, TLC, and clinical indicators to establish 11 multivariable models. At last, the receiver operating characteristic (ROC) curve performance was compared by DeLong test. Results: A total of 172 patients were included. Compared with good outcome group, patients of poor outcome group showed advanced age {73.137±11.020 years old; 76 [interquartile range (IQR), 66–81] years old}, higher National Institutes of Health Stroke Scale (NIHSS) [12.34±6.308; 12 (IQR, 8–16)], lower 4D-VCS [5.67±3.988; 5 (IQR, 3–8)], lower COVES [3.088±1.904; 3 (IQR, 2–5)], Slow1 + Poor and Slow2 + Poor. The results of binary logistic regression analysis showed that the advanced age and high NIHSS were independent predictors for poor outcome in all 11 models (PConclusions: The three evaluation indicators of VO based on 4D-CTA/CTP can independently predict the long-term functional prognosis of AIS-LVO patients, and 4D-VCS had relatively higher predictive value. In the prognosis prediction of AIS-LVO patients, the combined model including 4D-VCS, clinical indicators, and TLC was superior to the model which only included clinical indicators.
- Open Access
- 1 September 2023
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 13 (9) , 6026-6036
Imaging features of cardioembolic stroke on 4-dimensional computed tomography angiography
Background: Identifying cardioembolic stroke is important for the decision-making of endovascular treatment and anticoagulation therapy. We aimed to explore the features of cardioembolic stroke on 4-dimensional (4D) computed tomography angiography (4D-CTA) and assess whether these features can assist in classifying stroke etiology. Methods: In this retrospective study, we analyzed the images of 294 patients with acute ischemic stroke (AIS) from July 2020 to February 2022 at the First Affiliated Hospital of Chongqing Medical University, which had been consecutively collected. The data of 110 patients with occlusion of the M1/M2 segment of the middle cerebral artery (MCA) with/without intracranial internal carotid artery (ICA) occlusion were analyzed to calculate the clot burden score (CBS) and collateral score (CS), and the data of 88 patients with a clear origin and distal part were analyzed to measure clot length. Maximum intensity projection (MIP) and time MIP (tMIP) post-processing were used to assess the clot features. The Mann-Whitney U test was used to compare the clot characteristics between the 2 groups. Binary logistic regression was performed to assess the association between the image characteristics and cardioembolic stroke. Moreover, the receiver operating characteristic (ROC) curve was used to test the diagnostic efficacy of MIP/tMIP clot features in classifying cardioembolic stroke. Results: Age, high-risk factors for cerebrovascular disease, high/medium-risk sources of cardioembolic stroke, clot length, CBS, and CS were significantly different between the cardioembolic stroke group and non-cardioembolic stroke group (PConclusions: Clot length and CBS were overestimated on MIP images. Among the clot characteristics, clot length could identify cardioembolic stroke.
- 1 September 2023
- Published by AME Publishing Company in Quantitative Imaging in Medicine and Surgery
- Vol. 13 (9) , 6026-6036
Open AccessImaging features of cardioembolic stroke on 4-dimensional computed tomography angiography
Background: Identifying cardioembolic stroke is important for the decision-making of endovascular treatment and anticoagulation therapy. We aimed to explore the features of cardioembolic stroke on 4-dimensional (4D) computed tomography angiography (4D-CTA) and assess whether these features can assist in classifying stroke etiology. Methods: In this retrospective study, we analyzed the images of 294 patients with acute ischemic stroke (AIS) from July 2020 to February 2022 at the First Affiliated Hospital of Chongqing Medical University, which had been consecutively collected. The data of 110 patients with occlusion of the M1/M2 segment of the middle cerebral artery (MCA) with/without intracranial internal carotid artery (ICA) occlusion were analyzed to calculate the clot burden score (CBS) and collateral score (CS), and the data of 88 patients with a clear origin and distal part were analyzed to measure clot length. Maximum intensity projection (MIP) and time MIP (tMIP) post-processing were used to assess the clot features. The Mann-Whitney U test was used to compare the clot characteristics between the 2 groups. Binary logistic regression was performed to assess the association between the image characteristics and cardioembolic stroke. Moreover, the receiver operating characteristic (ROC) curve was used to test the diagnostic efficacy of MIP/tMIP clot features in classifying cardioembolic stroke. Results: Age, high-risk factors for cerebrovascular disease, high/medium-risk sources of cardioembolic stroke, clot length, CBS, and CS were significantly different between the cardioembolic stroke group and non-cardioembolic stroke group (PConclusions: Clot length and CBS were overestimated on MIP images. Among the clot characteristics, clot length could identify cardioembolic stroke.
- Open Access
- 20 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1810
Comparison of Three Algorithms for Predicting Infarct Volume in Patients with Acute Ischemic Stroke by CT Perfusion Software: Bayesian, CSVD, and OSVD
This study aimed to compare the performance of the Bayesian probabilistic method, circular Singular Value Decomposition (cSVD), and oscillation index Singular Value Decomposition (oSVD) algorithms in Olea Sphere for predicting infarct volume in patients with acute ischemic stroke (AIS). Eighty-seven patients suffering from AIS with large vessel occlusion were divided into improvement and progression groups. The improvement group included patients with successful recanalization (TICI 2b-3) after thrombectomy or whose clinical symptoms improved after thrombolysis. The progression group consisted of patients whose clinical symptoms did not improve or even got worse. The infarct core volume from the Olea Sphere software was used as the predicted infarct volume (PIV) in the improvement group, whereas the hypoperfusion volume was used as the PIV in the progression group. We defined predicted difference (PD) as PIV minus final infarct volume (FIV) measured at follow-up imaging. Differences among the three algorithms were assessed by the Friedman test. Spearman correlation analysis was used to verify the correlation between PIV and FIV. In addition, we performed a subgroup analysis of the progression group based on collateral circulation status. The median [interquartile range (IQR)] of the PD and Spearman correlation coefficients (SCCs) between PIV and FIV for the improvement group (n = 22) were: Bayesian = [6.99 (−14.72, 18.99), 0.500]; oSVD = [−12.74 (−41.06, −3.46), 0.423]; cSVD = [−15.38 (−38.92, −4.68), 0.586]. For the progression group (n = 65), the median (IQR) of PD and SCCs were: Bayesian = [1.00 (−34.07, 49.37), 0.748]; oSVD = [−0.17 (−53.42, 29.73), 0.712]; cSVD = [66.55 (7.94, 106.32), 0.674]. The Bayesian algorithm in the Olea Sphere software predicted infarct volumes with better accuracy and stability than the other two algorithms in both the progression and improvement groups.
- 20 May 2023
- Published by MDPI AG in Diagnostics
- Vol. 13 (10) , 1810
Open AccessComparison of Three Algorithms for Predicting Infarct Volume in Patients with Acute Ischemic Stroke by CT Perfusion Software: Bayesian, CSVD, and OSVD
This study aimed to compare the performance of the Bayesian probabilistic method, circular Singular Value Decomposition (cSVD), and oscillation index Singular Value Decomposition (oSVD) algorithms in Olea Sphere for predicting infarct volume in patients with acute ischemic stroke (AIS). Eighty-seven patients suffering from AIS with large vessel occlusion were divided into improvement and progression groups. The improvement group included patients with successful recanalization (TICI 2b-3) after thrombectomy or whose clinical symptoms improved after thrombolysis. The progression group consisted of patients whose clinical symptoms did not improve or even got worse. The infarct core volume from the Olea Sphere software was used as the predicted infarct volume (PIV) in the improvement group, whereas the hypoperfusion volume was used as the PIV in the progression group. We defined predicted difference (PD) as PIV minus final infarct volume (FIV) measured at follow-up imaging. Differences among the three algorithms were assessed by the Friedman test. Spearman correlation analysis was used to verify the correlation between PIV and FIV. In addition, we performed a subgroup analysis of the progression group based on collateral circulation status. The median [interquartile range (IQR)] of the PD and Spearman correlation coefficients (SCCs) between PIV and FIV for the improvement group (n = 22) were: Bayesian = [6.99 (−14.72, 18.99), 0.500]; oSVD = [−12.74 (−41.06, −3.46), 0.423]; cSVD = [−15.38 (−38.92, −4.68), 0.586]. For the progression group (n = 65), the median (IQR) of PD and SCCs were: Bayesian = [1.00 (−34.07, 49.37), 0.748]; oSVD = [−0.17 (−53.42, 29.73), 0.712]; cSVD = [66.55 (7.94, 106.32), 0.674]. The Bayesian algorithm in the Olea Sphere software predicted infarct volumes with better accuracy and stability than the other two algorithms in both the progression and improvement groups.
- Open Access
- 27 June 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (7) , 1562
Merging Multiphase CTA Images and Training Them Simultaneously with a Deep Learning Algorithm Could Improve the Efficacy of AI Models for Lateral Circulation Assessment in Ischemic Stroke
We aimed to build a deep learning-based, objective, fast, and accurate collateral circulation assessment model. We included 92 patients who had suffered acute ischemic stroke (AIS) with large vessel occlusion in the anterior circulation in this study, following their admission to our hospital from June 2020 to August 2021. We analyzed their baseline whole-brain four-dimensional computed tomography angiography (4D-CTA)/CT perfusion. The images of the arterial, arteriovenous, venous, and late venous phases were extracted from 4D-CTA according to the perfusion time–density curve. The subtraction images of each phase were created by subtracting the non-contrast CT. Each patient was marked as having good or poor collateral circulation. Based on the ResNet34 classification network, we developed a single-image input and a multi-image input network for binary classification of collateral circulation. The training and test sets included 65 and 27 patients, respectively, and Monte Carlo cross-validation was employed for five iterations. The network performance was evaluated based on its precision, accuracy, recall, F1-score, and AUC. All the five performance indicators of the single-image input model were higher than those of the other model. The single-image input processing network, combining multiphase CTA images, can better classify AIS collateral circulation. This automated collateral assessment tool could help to streamline clinical workflows, and screen patients for reperfusion therapy.
- 27 June 2022
- Published by MDPI AG in Diagnostics
- Vol. 12 (7) , 1562
Open AccessMerging Multiphase CTA Images and Training Them Simultaneously with a Deep Learning Algorithm Could Improve the Efficacy of AI Models for Lateral Circulation Assessment in Ischemic Stroke
We aimed to build a deep learning-based, objective, fast, and accurate collateral circulation assessment model. We included 92 patients who had suffered acute ischemic stroke (AIS) with large vessel occlusion in the anterior circulation in this study, following their admission to our hospital from June 2020 to August 2021. We analyzed their baseline whole-brain four-dimensional computed tomography angiography (4D-CTA)/CT perfusion. The images of the arterial, arteriovenous, venous, and late venous phases were extracted from 4D-CTA according to the perfusion time–density curve. The subtraction images of each phase were created by subtracting the non-contrast CT. Each patient was marked as having good or poor collateral circulation. Based on the ResNet34 classification network, we developed a single-image input and a multi-image input network for binary classification of collateral circulation. The training and test sets included 65 and 27 patients, respectively, and Monte Carlo cross-validation was employed for five iterations. The network performance was evaluated based on its precision, accuracy, recall, F1-score, and AUC. All the five performance indicators of the single-image input model were higher than those of the other model. The single-image input processing network, combining multiphase CTA images, can better classify AIS collateral circulation. This automated collateral assessment tool could help to streamline clinical workflows, and screen patients for reperfusion therapy.
- 1 January 2018
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 91 (1083) , 20150777
Structural abnormalities and altered regional brain activity in multiple sclerosis with simple spinal cord involvement
Objective: To assess the changes of the structural and functional abnormalities in multiple sclerosis with simple spinal cord involvement (MS-SSCI) by using resting-state functional MRI (RS-fMRI), voxel based morphology (VBM) and diffusion tensor tractography. Methods: The amplitude of low-frequency fluctuation (ALFF) of 22 patients with MS-SSCI and 22 healthy controls (HCs) matched for age, gender and education were compared by using RS-fMRI. We also compared the volume, fractional anisotropy (FA) and apparent diffusion coefficient of the brain regions in baseline brain activity by using VBM and diffusion tensor imaging. The relationships between the expanded disability states scale (EDSS) scores, changed parameters of structure and function were further explored. Results: (1) Compared with HCs, the ALFF of the bilateral hippocampus and right middle temporal gyrus in MS-SSCI decreased significantly. However, patients exhibited increased ALFF in the left middle frontal gyrus, left posterior cingulate gyrus and right middle occipital gyrus ( two-sample t-test, after AlphaSim correction, p < 0.01, voxel size > 40). The volume of right middle frontal gyrus reduced significantly (p < 0.01). The FA and ADC of right hippocampus, the FA of left hippocampus and right middle temporal gyrus were significantly different. (2) A significant correlation between EDSS scores and ALFF was noted only in the left posterior cingulate gyrus. Conclusion: Our results detected structural and functional abnormalities in MS-SSCI and functional parameters were associated with clinical abnormalities. Multimodal imaging plays an important role in detecting structural and functional abnormalities in MS-SSCI. Advances in knowledge: This is the first time to apply RS-fMRI, VBM and diffusion tensor tractography to study the structural and functional abnormalities in MS-SSCI, and to explore its correlation with EDSS score.
- 1 January 2018
- Published by Oxford University Press (OUP) in British Journal of Radiology
- Vol. 91 (1083) , 20150777
Structural abnormalities and altered regional brain activity in multiple sclerosis with simple spinal cord involvement
Objective: To assess the changes of the structural and functional abnormalities in multiple sclerosis with simple spinal cord involvement (MS-SSCI) by using resting-state functional MRI (RS-fMRI), voxel based morphology (VBM) and diffusion tensor tractography. Methods: The amplitude of low-frequency fluctuation (ALFF) of 22 patients with MS-SSCI and 22 healthy controls (HCs) matched for age, gender and education were compared by using RS-fMRI. We also compared the volume, fractional anisotropy (FA) and apparent diffusion coefficient of the brain regions in baseline brain activity by using VBM and diffusion tensor imaging. The relationships between the expanded disability states scale (EDSS) scores, changed parameters of structure and function were further explored. Results: (1) Compared with HCs, the ALFF of the bilateral hippocampus and right middle temporal gyrus in MS-SSCI decreased significantly. However, patients exhibited increased ALFF in the left middle frontal gyrus, left posterior cingulate gyrus and right middle occipital gyrus ( two-sample t-test, after AlphaSim correction, p < 0.01, voxel size > 40). The volume of right middle frontal gyrus reduced significantly (p < 0.01). The FA and ADC of right hippocampus, the FA of left hippocampus and right middle temporal gyrus were significantly different. (2) A significant correlation between EDSS scores and ALFF was noted only in the left posterior cingulate gyrus. Conclusion: Our results detected structural and functional abnormalities in MS-SSCI and functional parameters were associated with clinical abnormalities. Multimodal imaging plays an important role in detecting structural and functional abnormalities in MS-SSCI. Advances in knowledge: This is the first time to apply RS-fMRI, VBM and diffusion tensor tractography to study the structural and functional abnormalities in MS-SSCI, and to explore its correlation with EDSS score.