JMJ. Scott Mellors

J. Scott Mellors

*This is an algorithmically generated author record based on publicly available information.

J. Scott Mellors has a total of 40 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Performance Evaluation of a Quantitative Metabolomics Workflow Incorporating Microchip Capillary Electrophoresis, Indexed Migration Time, and Single-Point External Calibration

    by J. Scott Mellors, Corinne Moss, Erin A. Redman, Christopher Shuford, James P. Campbell, J. Michael Ramsey, Joshua J. Coon, J. Will Thompson

    Capillary electrophoresis-mass spectrometry (CE-MS) offers unique analytical advantages for polar metabolite profiling but has remained underutilized in metabolomics relative to liquid chromatography-MS (LC-MS), in part due to challenges in managing migration time drift during data analysis. Here we introduce the use of indexed migration time (iMT) for easily managing this aspect of CE-MS data for metabolomics. Migration time indexing using a panel of stable isotope-labeled (SIL) amino acid reference standards, stored as an iRT database in Skyline, outperformed both uncorrected migration time and relative migration time (RMT) correction across three independent analytical batches spanning 90 samples from four biological matrices. The indexed migration time approach achieved sub-1% relative standard deviation (RSD) in migration index across batches, compared to up to ~15% RSD for uncorrected migration times. Additionally, we evaluate the use of single-point external calibration in Skyline for the purposes of metabolite quantification from complex matrices in order to ease the burden of translational metabolite quantification from metabolomics using high-resolution mass spectrometry (HRMS). Single-point external calibration using a biological matrix-based calibrator was benchmarked against a 13-point linear calibration curve across a panel of amino acids; above 1 μM, greater than 95% of back-calculated concentrations fell within ±20% of multi-point calibration. Application of the complete workflow to plasma, serum, urine, and NIST Standard Reference Material (SRM)-1950 demonstrated low inter-batch variability by principal components analysis, broad metabolite coverage across 126 quantifiable analytes, and strong quantitative concordance (Deming slope = 0.862, pseudo-R 2 = 0.994, n = 64 analytes) with an independent comprehensive reference dataset for NIST SRM-1950. Together, these results establish a practical mCE-HRMS metabolomics workflow that bridges targeted and discovery metabolomics paradigms and lays the groundwork for single-point external calibration as a powerful tool for translational metabolomics.

  • Open Access

    SPE-CZE-MS Quantifies Zeptomole Amounts of Phosphorylated Peptides

    by Lia R. Serrano, J. Scott Mellors, J. Will Thompson, Noah M. Lancaster, Margaret Lea Robinson, Katherine A. Overmyer, Scott T. Quarmby, Joshua J. Coon

    Capillary zone electrophoresis (CZE) is gaining attention in the field of single-cell proteomics for its ultralow-flow and high-resolution separation abilities. Even more sample-limited yet rich in biological information are phosphoproteomics experiments, as the phosphoproteome composes only a fraction of the whole cellular proteome. Rapid analysis, high sensitivity, and maximization of sample utilization are paramount for single-cell analysis. Some challenges of coupling CZE analysis with mass spectrometry analysis (MS) of complex mixtures include 1. sensitivity due to volume loading limitations of CZE and 2. incompatibility of MS duty cycles with electropherographic time scales. Here, we address these two challenges as applied to single-cell-equivalent phosphoproteomics experiments by interfacing a microchip-based CZE device integrated with a solid-phase-extraction (SPE) bed with the Orbitrap Astral mass spectrometer. Using 225 phosphorylated peptide standards and phosphorylated peptide-enriched mouse brain tissue, we investigate microchip-based SPE-CZE functionality, quantitative performance, and complementarity to nano-LC-MS (nLC-MS) analysis. We highlight unique SPE-CZE separation mechanisms that can empower fit-for-purpose applications in single-cell-equivalent phosphoproteomics.


  • Open Access

    SPE-CZE-MS quantifies zeptomole concentrations of phosphorylated peptides

    by Lia R. Serrano, J. Scott Mellors, J. Will Thompson, Noah M. Lancaster, Margaret Lea Robinson, Katherine A. Overmyer, Scott T. Quarmby, Joshua J. Coon

    Capillary zone electrophoresis (CZE) is gaining attention in the field of single-cell proteomics for its ultra-low-flow and high-resolution separation abilities. Even more sample-limited yet rich in biological information are phosphoproteomics experiments, as the phosphoproteome composes only a fraction of the whole cellular proteome. Rapid analysis, high sensitivity, and maximization of sample utilization are paramount for single-cell analysis. Some challenges of coupling CZE analysis with mass spectrometry analysis (MS) of complex mixtures include 1. sensitivity due to volume loading limitations of CZE and 2. incompatibility of MS duty cycles with electrophoretic timescales. Here, we address these two challenges as applied to single-cell equivalent phosphoproteomics experiments by interfacing a microchip-based CZE device integrated with a solid-phase-extraction (SPE) bed with the Orbitrap Astral mass spectrometer. Using 225 phosphorylated peptide standards and phosphorylated peptide-enriched mouse brain tissue, we investigate microchip-based SPE-CZE functionality, quantitative performance, and complementarity to nano-LC-MS (nLC-MS) analysis. We highlight unique SPE-CZE separation mechanisms that can empower fit-for-purpose applications in single-cell-equivalent phosphoproteomics.


  • Open Access

    A microfluidic chip-based capillary zone electrophoresis-mass spectrometry method for measuring adenosine 5′-Triphosphate and its similar nucleotide analogues

    by Cristina Di Poto, Xiang Tian, Scott Mellors, Sanna Rosengren, Sabina Issop, Sara J. Bonvini, Sonja Hess, Erik L. Allman


  • Open Access

    High-Throughput, Quantitative Analysis of Peptide-Exchanged MHCI Complexes by Native Mass Spectrometry

    by Luis F. Schachner, Wilson Phung, Guanghui Han, Martine Darwish, Ashley Bell, J. Scott Mellors, Kristina Srzentic, Romain Huguet, Craig Blanchette, Wendy Sandoval

    Immune monitoring in cancer immunotherapy involves screening CD8+ T-cell responses against neoantigens, the tumor-specific peptides presented by Major histocompatibility complex Class I (MHCI) on the cell surface. High-throughput immune monitoring requires methods to produce and characterize small quantities of thousands of MHCI-peptide complexes that may be tested for a patient's T-cell response. MHCI synthesis has been achieved using a photocleavable peptide that is exchanged by the neoantigen; however, assays that measure peptide exchange currently disassemble the complex prior to analysis─precluding direct molecular characterization. Here, we use native mass spectrometry (MS) to profile intact recombinant MHCI complexes and directly measure peptide exchange. Coupled with size-exclusion chromatography or capillary-zone electrophoresis, the assay identified all tested human leukocyte antigen (HLA)/peptide combinations in the nanomole to picomole range with minimal run time, reconciling the synthetic and analytical requirements of MHCI-peptide screening with the downstream T-cell assays. We further show that the assay can be "multiplexed" by measuring exchange of multiple peptides simultaneously and also enables calculation of Vc50, a measure of gas-phase stability. Additionally, MHCI complexes were fragmented by top-down sequencing, demonstrating that the intact complex, peptide sequence, and their binding affinity can be determined in a single analysis. This screening tool for MHCI-neoantigen complexes represents a step toward the application of state-of-the-art MS technology in translational settings. Not only is this assay already informing on the viability of immunotherapy in practice, the platform also holds promise to inspire novel MS readouts for increasingly complex biomolecules used in the diagnosis and treatment of disease.


  • On-Chip Preconcentration Microchip Capillary Electrophoresis Based CE-PRM-LIVE for High-Throughput Selectivity Profiling of Deubiquitinase Inhibitors

    by He Zhu, J. Scott Mellors, Wai Cheung Chan, J. Will Thompson, Scott B. Ficarro, Isidoro Tavares, Ariana S. Bratt, Jens Decker, Michael Krause, Gary Kruppa, et al.

    The family of deubiquitinases (DUBs) comprises ∼100 enzymes that cleave ubiquitin from substrate proteins and thereby regulate key aspects of human physiology. DUBs have recently emerged as disease-relevant and chemically tractable, although currently there are no approved DUB-targeting drugs and most preclinical small molecules are low-potency and/or multitargeted. We paired a novel capillary electrophoresis microchip containing an integrated, "on-chip" C18 bed (SPE-ZipChip) with a TMT version of our recently described PRM-LIVE acquisition scheme on a timsTOF Pro mass spectrometer to facilitate rapid activity-based protein profiling of DUB inhibitors. We demonstrate the ability of the SPE-ZipChip to improve proteome coverage of complex samples as well as the quantitation integrity of CE-PRM-LIVE for TMT labeled samples. These technologies provide a platform to accurately quantify competitive binding of covalent and reversible inhibitors in a multiplexed assay that spans 49 endogenous DUBs in less than 15 min.