Ann-Marie Taroc
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Ann-Marie Taroc has a total of 50 co-authors. Here are the top co-authors by number of shared publications:
Abdul Hakim Al‐Rawas
Sultan Qaboos Univ, Sultan Qaboos Univ Hosp, Muscat, Oman
1 shared publication- Aggrey Dhabangi
Child Health and Development Centre Makerere University College of Health Sciences Kampala Uganda
1 shared publication - Alshakim Nelson
University of Washington
1 shared publication - Ana Paula Hitomi Yokoyama
Hospital Israelita Albert Einstein, São Paulo, SP, Brazil
1 shared publication - Anel van Zyl
Stellenbosch University
1 shared publication - Arwa Z. Al-Riyami
Department of Hematology Sultan Qaboos University Hospital, University Medical City Muscat Oman
1 shared publication
Latest Publications
- 17 January 2023
- Published by Wiley in Vox Sanguinis
- Vol. 118 (3) , 230-251
International Forum on Small‐Volume Transfusions in Neonates and Paediatric Patients: Responses
- 17 January 2023
- Published by Wiley in Vox Sanguinis
- Vol. 118 (3) , 230-251
International Forum on Small‐Volume Transfusions in Neonates and Paediatric Patients: Responses
- Open Access
- 28 June 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (13) , 7164
Prototype Development of a Temperature-Sensitive High-Adhesion Medical Tape to Reduce Medical-Adhesive-Related Skin Injury and Improve Quality of Care
Medical adhesives are used to secure wound care dressings and other critical devices to the skin. Without means of safe removal, these stronger adhesives are difficult to painlessly remove from the skin and may cause medical-adhesive-related skin injuries (MARSI), including skin tears and an increased risk of infection. Lower-adhesion medical tapes may be applied to avoid MARSI, leading to device dislodgement and further medical complications. This paper outlines the development of a high-adhesion medical tape designed for low skin trauma upon release. By warming the skin-attached tape for 10–30 s, a significant loss in adhesion was achieved. A C14/C18 copolymer was developed and combined with a selected pressure-sensitive adhesive (PSA) material. The addition of 1% C14/C18 copolymer yielded the largest temperature-responsive drop in surface adhesion. The adhesive film was characterized using AFM, and distinct nanodomains were identified on the exterior surface of the PSA. Our optimized formulation yielded 67% drop in adhesion when warmed to 45 °C, perhaps due to melting nanodomains weakening the adhesive–substrate boundary layer. Pilot clinical testing resulted in a significant decrease in pain when a heat pack was used for removal, giving an average pain reduction of 66%.
- 28 June 2022
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 23 (13) , 7164
Open AccessPrototype Development of a Temperature-Sensitive High-Adhesion Medical Tape to Reduce Medical-Adhesive-Related Skin Injury and Improve Quality of Care
Medical adhesives are used to secure wound care dressings and other critical devices to the skin. Without means of safe removal, these stronger adhesives are difficult to painlessly remove from the skin and may cause medical-adhesive-related skin injuries (MARSI), including skin tears and an increased risk of infection. Lower-adhesion medical tapes may be applied to avoid MARSI, leading to device dislodgement and further medical complications. This paper outlines the development of a high-adhesion medical tape designed for low skin trauma upon release. By warming the skin-attached tape for 10–30 s, a significant loss in adhesion was achieved. A C14/C18 copolymer was developed and combined with a selected pressure-sensitive adhesive (PSA) material. The addition of 1% C14/C18 copolymer yielded the largest temperature-responsive drop in surface adhesion. The adhesive film was characterized using AFM, and distinct nanodomains were identified on the exterior surface of the PSA. Our optimized formulation yielded 67% drop in adhesion when warmed to 45 °C, perhaps due to melting nanodomains weakening the adhesive–substrate boundary layer. Pilot clinical testing resulted in a significant decrease in pain when a heat pack was used for removal, giving an average pain reduction of 66%.
- 1 January 2022
- Published by Association for Vascular Access in Journal of the Association for Vascular Access
- Vol. 27 (3) , 36-42
Identifying Odds of Bloodstream Infection in Repaired Silastic Central Venous Catheters in a Pediatric Population
Highlights: Nurse-led research is investigating infection in repaired central venous catheters. Eight out of 9 retrospective studies found no increased risk of infection with a repair. Broken catheters outside the hospital setting may be at risk for bacteremia. There are low frequencies of CLABSI or bacteremia and exposure to line repair. Background: Silicone central venous catheters (CVCs) that weaken or rupture are reparable using a commercial repair kit. A literature review exploring bloodstream infections in repaired CVCs identified many findings indicating low or no increased risk of infection. This study aimed to understand pediatric patients’ risk of bloodstream infection with repaired Hickman or Broviac catheters. Methods: A matched retrospective case-control study examined central line–associated bloodstream infection (CLABSI) or bacteremia in two separately matched cohorts of patients with silicone-type catheters. Controls were patients with CVCs selected from 2016 to 2019 and were matched to cases based on age group (older or younger than 3 years). Conditional logistic regression models calculated odds ratios (OR), with 95% confidence intervals (CI) representing the odds of a line repair occurring 30 days before an event among cases versus controls. Results: In 61 CLABSI cases and 104 controls, the OR of exposure to a line repair was 0.43; 95% CI, 0.05–3.87, P = 0.45. In comparing 49 bacteremia cases to 109 controls, the OR of exposure to a line repair was 6.69; 95% CI, 0.69–8, P = 0.10. Conclusions: The frequency of CVC repair was relatively low. Associations between repair and infection were not detected in either cohort; however, odds of line repair exposure appeared to be higher in bacteremia cases (a trend not observed in the CLABSI cohort). More extensive studies examining the demographic and clinical characteristics of the CVC repair population will be critical for improving outcomes.
- 1 January 2022
- Published by Association for Vascular Access in Journal of the Association for Vascular Access
- Vol. 27 (3) , 36-42
Identifying Odds of Bloodstream Infection in Repaired Silastic Central Venous Catheters in a Pediatric Population
Highlights: Nurse-led research is investigating infection in repaired central venous catheters. Eight out of 9 retrospective studies found no increased risk of infection with a repair. Broken catheters outside the hospital setting may be at risk for bacteremia. There are low frequencies of CLABSI or bacteremia and exposure to line repair. Background: Silicone central venous catheters (CVCs) that weaken or rupture are reparable using a commercial repair kit. A literature review exploring bloodstream infections in repaired CVCs identified many findings indicating low or no increased risk of infection. This study aimed to understand pediatric patients’ risk of bloodstream infection with repaired Hickman or Broviac catheters. Methods: A matched retrospective case-control study examined central line–associated bloodstream infection (CLABSI) or bacteremia in two separately matched cohorts of patients with silicone-type catheters. Controls were patients with CVCs selected from 2016 to 2019 and were matched to cases based on age group (older or younger than 3 years). Conditional logistic regression models calculated odds ratios (OR), with 95% confidence intervals (CI) representing the odds of a line repair occurring 30 days before an event among cases versus controls. Results: In 61 CLABSI cases and 104 controls, the OR of exposure to a line repair was 0.43; 95% CI, 0.05–3.87, P = 0.45. In comparing 49 bacteremia cases to 109 controls, the OR of exposure to a line repair was 6.69; 95% CI, 0.69–8, P = 0.10. Conclusions: The frequency of CVC repair was relatively low. Associations between repair and infection were not detected in either cohort; however, odds of line repair exposure appeared to be higher in bacteremia cases (a trend not observed in the CLABSI cohort). More extensive studies examining the demographic and clinical characteristics of the CVC repair population will be critical for improving outcomes.