Zhuohui Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Zhuohui Wu has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Xiaoping Wang
Ocean College, Zhejiang University, Zhoushan 316021, China
2 shared publications - Hanjing Deng
Beibu Gulf Port Co., Ltd., Nanning 530201, China
1 shared publication - Haoyuan Cai
College of Ocean Information Engineering, Jimei University, Xiamen 361021, China
1 shared publication - Jing Liu
School of Ocean Information Engineering, Fujian Provincial Key Laboratory of Oceanic Information Perception and Intelligent Processing, Jimei University, Xiamen 361021, China
1 shared publication - Mengwei Wang
Ocean College, Zhejiang University, Zhoushan 316021, China
1 shared publication - Shihan Shan
Ocean College, Zhejiang University, Zhoushan 316021, China
1 shared publication
Latest Publications
- Open Access
- 24 November 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (12) , 247
Rapid Correction of Turbidity Interference on Chemical Oxygen Demand Measurements by Using Ultraviolet-Visible Spectrometry
We developed a simple, rapid, and high-precision method to compensate for the turbidity interference in the measurement of water parameters using ultraviolet-visible spectrometry. By combining direct orthogonal signal correction (DOSC) with partial least squares (PLS), we corrected the full spectra (220 nm to 600 nm), significantly enhancing the accuracy of the water parameter calculations. First, DOSC was applied to filter out turbidity-related components, retaining only the spectral elements most closely associated with the target substance, without requiring a standard baseline for the turbidity effect. Then, 13 wavelengths were selected from the corrected full spectra to construct the discrete absorption spectra. Further, a PLS regression model was established based on the corrected discrete absorption spectra and their corresponding concentrations. In our experiment, this method effectively eliminated the blue shift and peak height reduction caused by turbidity, especially in shorter wavelengths, which are more sensitive to interference. Moreover, when applied to new samples, the correlation coefficients (R2) between the predicted and actual values improved from 0.5455 to 0.9997, and the root mean square error (RMSE) decreased from 12.3604 to 0.2295 after correction. Overall, the DOSC-PLS method, together with ultraviolet-visible spectrometry, posed a great potential for the precise monitoring of target water parameters in field studies.
- 24 November 2024
- Published by MDPI AG in Chemosensors
- Vol. 12 (12) , 247
Open AccessRapid Correction of Turbidity Interference on Chemical Oxygen Demand Measurements by Using Ultraviolet-Visible Spectrometry
We developed a simple, rapid, and high-precision method to compensate for the turbidity interference in the measurement of water parameters using ultraviolet-visible spectrometry. By combining direct orthogonal signal correction (DOSC) with partial least squares (PLS), we corrected the full spectra (220 nm to 600 nm), significantly enhancing the accuracy of the water parameter calculations. First, DOSC was applied to filter out turbidity-related components, retaining only the spectral elements most closely associated with the target substance, without requiring a standard baseline for the turbidity effect. Then, 13 wavelengths were selected from the corrected full spectra to construct the discrete absorption spectra. Further, a PLS regression model was established based on the corrected discrete absorption spectra and their corresponding concentrations. In our experiment, this method effectively eliminated the blue shift and peak height reduction caused by turbidity, especially in shorter wavelengths, which are more sensitive to interference. Moreover, when applied to new samples, the correlation coefficients (R2) between the predicted and actual values improved from 0.5455 to 0.9997, and the root mean square error (RMSE) decreased from 12.3604 to 0.2295 after correction. Overall, the DOSC-PLS method, together with ultraviolet-visible spectrometry, posed a great potential for the precise monitoring of target water parameters in field studies.
- Open Access
- 28 June 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (13) , 2219
Performance Enhancement of SPR Biosensor Using Graphene–MoS2 Hybrid Structure
We investigate a high-sensitivity surface plasmon resonance (SPR) biosensor consisting of a Au layer, four-layer MoS2, and monolayer graphene. The numerical simulations, by the transfer matrix method (TMM), demonstrate the sensor has a maximum sensitivity of 282°/RIU, which is approximately 2 times greater than the conventional Au-based SPR sensor. The finite difference time domain (FDTD) indicates that the presence of MoS2 film generates a strong surface electric field and enhances the sensitivity of the proposed SPR sensor. In addition, the influence of the number of MoS2 layers on the sensitivity of the proposed sensor is investigated by simulations and experiments. In the experiment, MoS2 and graphene films are transferred on the Au-based substrate by the PMMA-based wet transfer method, and the fabricated samples are characterized by Raman spectroscopy. Furthermore, the fabricated sensors with the Kretschmann configuration are used to detect okadaic acid (OA). The okadaic acid–bovine serum albumin bioconjugate (OA-BSA) is immobilized on the graphene layer of the sensors to develop a competitive inhibition immunoassay. The results show that the sensor has a very low limit of detection (LOD) of 1.18 ng/mL for OA, which is about 22.6 times lower than that of a conventional Au biosensor. We believe that such a high-sensitivity SPR biosensor has potential applications for clinical diagnosis and immunoassays.
- 28 June 2022
- Published by MDPI AG in Nanomaterials
- Vol. 12 (13) , 2219
Open AccessPerformance Enhancement of SPR Biosensor Using Graphene–MoS2 Hybrid Structure
We investigate a high-sensitivity surface plasmon resonance (SPR) biosensor consisting of a Au layer, four-layer MoS2, and monolayer graphene. The numerical simulations, by the transfer matrix method (TMM), demonstrate the sensor has a maximum sensitivity of 282°/RIU, which is approximately 2 times greater than the conventional Au-based SPR sensor. The finite difference time domain (FDTD) indicates that the presence of MoS2 film generates a strong surface electric field and enhances the sensitivity of the proposed SPR sensor. In addition, the influence of the number of MoS2 layers on the sensitivity of the proposed sensor is investigated by simulations and experiments. In the experiment, MoS2 and graphene films are transferred on the Au-based substrate by the PMMA-based wet transfer method, and the fabricated samples are characterized by Raman spectroscopy. Furthermore, the fabricated sensors with the Kretschmann configuration are used to detect okadaic acid (OA). The okadaic acid–bovine serum albumin bioconjugate (OA-BSA) is immobilized on the graphene layer of the sensors to develop a competitive inhibition immunoassay. The results show that the sensor has a very low limit of detection (LOD) of 1.18 ng/mL for OA, which is about 22.6 times lower than that of a conventional Au biosensor. We believe that such a high-sensitivity SPR biosensor has potential applications for clinical diagnosis and immunoassays.