Mika Pihlajamäki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Mika Pihlajamäki has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Veikko Sariola
Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
4 shared publications - Anastasia Koivikko
Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
2 shared publications Vilma Lampinen
Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
2 shared publications- Vilma Lampinen
Faculty of Medicine and Health Technology Tampere University Tampere Finland
2 shared publications Vipul Sharma
Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
2 shared publicationsAnastasia Koivikko
Faculty of Medicine and Health Technology, Tampere University, Tampere, Finland
1 shared publication
Latest Publications
- Open Access
- 14 October 2026
- Published by Wiley in Advanced Robotics Research
Distributed Micropneumatic Sensors for Soft Robots to Detect Touch and Pose
Soft robots benefit from their compliant materials, but the potential of safe and reliable operation remains limited without integration of strain and tactile sensors to detect contact, collisions, and robot pose. While humans achieve dexterous grasping through a dense distribution of mechanoreceptors in their hands, soft robotic grippers likewise need touch and pose sensing. Soft grippers often use pneumatic actuators, but integrating electrical or optical sensors to such actuators complicates their fabrication. Recently, we have reported a novel class of stretchable sensors, where the tactile pressure or strain measurement is based on measuring changes in airflow resistance caused by the deformation of a soft microchannel. These sensors are fabricated using identical techniques and materials as soft pneumatic actuators. In this work, we present a three‐fingered soft gripper with 18 distributed micropneumatic sensors. Each finger consists of a pneumatic actuator and six micropneumatic sensors. We demonstrate that multichannel micropneumatic sensing enables reliable detection of finger pose and object contact, supporting object recognition during grasping. Overall, the work provides a solution for integrating touch and pose sensing into soft robots without requiring additional fabrication methods or materials beyond those used for pneumatic actuators.
- 14 October 2026
- Published by Wiley in Advanced Robotics Research
Open AccessDistributed Micropneumatic Sensors for Soft Robots to Detect Touch and Pose
Soft robots benefit from their compliant materials, but the potential of safe and reliable operation remains limited without integration of strain and tactile sensors to detect contact, collisions, and robot pose. While humans achieve dexterous grasping through a dense distribution of mechanoreceptors in their hands, soft robotic grippers likewise need touch and pose sensing. Soft grippers often use pneumatic actuators, but integrating electrical or optical sensors to such actuators complicates their fabrication. Recently, we have reported a novel class of stretchable sensors, where the tactile pressure or strain measurement is based on measuring changes in airflow resistance caused by the deformation of a soft microchannel. These sensors are fabricated using identical techniques and materials as soft pneumatic actuators. In this work, we present a three‐fingered soft gripper with 18 distributed micropneumatic sensors. Each finger consists of a pneumatic actuator and six micropneumatic sensors. We demonstrate that multichannel micropneumatic sensing enables reliable detection of finger pose and object contact, supporting object recognition during grasping. Overall, the work provides a solution for integrating touch and pose sensing into soft robots without requiring additional fabrication methods or materials beyond those used for pneumatic actuators.
- Open Access
- 23 September 2024
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (2)
Soft Micropneumatic Touchpad
Soft tactile sensors outputting fluidic signals have many potential applications in soft microfluidic devices and soft robots. However, existing systems have been limited to a single or a few sensors in parallel, so they are not comparable to the state‐of‐the‐art electrical resistive and capacitive touchpads, which can detect rich tactile information, including touch location, pressure, area, and even multiple touches simultaneously. This work reports a soft micropneumatic touchpad. The touchpad consists of 32 pneumatic channels inside soft elastomer, with 16 channels aligned row‐wise and 16 column‐wise. The flow resistance of each channel is measured using a pressure divider. When the pad is touched, the cross‐sectional area of the channels close to the contact location deforms, which changes the flow resistance of those channels. With 32 sensing channels, the location, depth, area of the contact, and even two simultaneous touches can be detected. Letters hand‐written on the touchpad can be reconstructed from the measured data. With the assumption of sparsity, a tactile pressure map, with a value at each 16 × 16 grid point, can also be reconstructed. This work opens a path to replace electronic tactile sensors in soft devices with all‐fluidic alternatives.
- 23 September 2024
- Published by Wiley in Advanced Intelligent Systems
- Vol. 7 (2)
Open AccessSoft Micropneumatic Touchpad
Soft tactile sensors outputting fluidic signals have many potential applications in soft microfluidic devices and soft robots. However, existing systems have been limited to a single or a few sensors in parallel, so they are not comparable to the state‐of‐the‐art electrical resistive and capacitive touchpads, which can detect rich tactile information, including touch location, pressure, area, and even multiple touches simultaneously. This work reports a soft micropneumatic touchpad. The touchpad consists of 32 pneumatic channels inside soft elastomer, with 16 channels aligned row‐wise and 16 column‐wise. The flow resistance of each channel is measured using a pressure divider. When the pad is touched, the cross‐sectional area of the channels close to the contact location deforms, which changes the flow resistance of those channels. With 32 sensing channels, the location, depth, area of the contact, and even two simultaneous touches can be detected. Letters hand‐written on the touchpad can be reconstructed from the measured data. With the assumption of sparsity, a tactile pressure map, with a value at each 16 × 16 grid point, can also be reconstructed. This work opens a path to replace electronic tactile sensors in soft devices with all‐fluidic alternatives.
- Open Access
- 1 June 2024
- Published by SAGE Publications in Robotics Reports
- Vol. 2 (1)
Soft Pneumatic Tactile Pressure Sensor Matrix
The use of fluidics in soft devices has gained popularity in recent years, particularly in actuators and logic circuits. However, most tactile pressure sensors in the literature output an electrical or optical signal increasing the complexity of soft devices as the electrical or optical signals are transduced from the sensors to fluidic logic, and electrical power is needed just for the purposes of sensors and transducers. Including electrical and optical materials into a soft device also complicates the fabrication of the device. To address these drawbacks, we propose a soft pneumatic tactile pressure sensor matrix consisting of four sensors and operating on fluidic principles. Each sensor contains a meandering microchannel fabricated only from the same elastomer typically used in soft devices. When compressed, the pressure drop of the channel changes, which is measured as a sensor output signal. Our sensors can detect forces ranging from under 0.1 N to 4 N, with a maximum sensitivity of 50.5 N −1 . They have a hysteresis of 3.9% and the sensor signal drifts 16.4% in 12 hours under static compression. By using multiple sensors in a matrix, we can detect the point of contact and the magnitude of the applied force. Furthermore, we demonstrate that by attaching a protruding post to the matrix, we can infer forces acting on the post in three axes. This work paves the way toward electronics-free, entirely fluidic soft devices and soft robots that can detect not only the magnitudes of the contact forces but also their locations.
- 1 June 2024
- Published by SAGE Publications in Robotics Reports
- Vol. 2 (1)
Open AccessSoft Pneumatic Tactile Pressure Sensor Matrix
The use of fluidics in soft devices has gained popularity in recent years, particularly in actuators and logic circuits. However, most tactile pressure sensors in the literature output an electrical or optical signal increasing the complexity of soft devices as the electrical or optical signals are transduced from the sensors to fluidic logic, and electrical power is needed just for the purposes of sensors and transducers. Including electrical and optical materials into a soft device also complicates the fabrication of the device. To address these drawbacks, we propose a soft pneumatic tactile pressure sensor matrix consisting of four sensors and operating on fluidic principles. Each sensor contains a meandering microchannel fabricated only from the same elastomer typically used in soft devices. When compressed, the pressure drop of the channel changes, which is measured as a sensor output signal. Our sensors can detect forces ranging from under 0.1 N to 4 N, with a maximum sensitivity of 50.5 N −1 . They have a hysteresis of 3.9% and the sensor signal drifts 16.4% in 12 hours under static compression. By using multiple sensors in a matrix, we can detect the point of contact and the magnitude of the applied force. Furthermore, we demonstrate that by attaching a protruding post to the matrix, we can infer forces acting on the post in three axes. This work paves the way toward electronics-free, entirely fluidic soft devices and soft robots that can detect not only the magnitudes of the contact forces but also their locations.
- Open Access
- 29 June 2022
- Published by Springer Nature in Communications Engineering
- Vol. 1 (1) , 1-10
Integrated stretchable pneumatic strain gauges for electronics-free soft robots
In soft robotics, actuators, logic and power systems can be entirely fluidic and electronics-free. However, sensors still typically rely on electric or optical principles. This adds complexity to fluidic soft robots because transducers are needed, and electrical materials have to be incorporated. Herein, we show a highly-stretchable pneumatic strain gauge based on a meandering microchannel in a soft elastomer material thus eliminating the need for an electrical signal in soft robots. Using such pneumatic sensors, we demonstrate an all-pneumatic gripper with integrated pneumatic strain gauges that is capable of autonomous closure and object recognition. The gauges can measure at least up to 300% engineering strains. The sensor exhibits a very stable signal over a 12-hour measurement period with no hysteresis. Using pneumatic sensors, all four major components of robots—actuators, logic, power, and sensors—can be pneumatic, enabling all-fluidic soft robots with proprioception and exteroception.
- 29 June 2022
- Published by Springer Nature in Communications Engineering
- Vol. 1 (1) , 1-10
Open AccessIntegrated stretchable pneumatic strain gauges for electronics-free soft robots
In soft robotics, actuators, logic and power systems can be entirely fluidic and electronics-free. However, sensors still typically rely on electric or optical principles. This adds complexity to fluidic soft robots because transducers are needed, and electrical materials have to be incorporated. Herein, we show a highly-stretchable pneumatic strain gauge based on a meandering microchannel in a soft elastomer material thus eliminating the need for an electrical signal in soft robots. Using such pneumatic sensors, we demonstrate an all-pneumatic gripper with integrated pneumatic strain gauges that is capable of autonomous closure and object recognition. The gauges can measure at least up to 300% engineering strains. The sensor exhibits a very stable signal over a 12-hour measurement period with no hysteresis. Using pneumatic sensors, all four major components of robots—actuators, logic, power, and sensors—can be pneumatic, enabling all-fluidic soft robots with proprioception and exteroception.