VHV. Hashim

V. Hashim

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


V. Hashim has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A Novel Approach by Integrating CT‐Based Imaging Data and Machine Learning to Predict Patient‐Specific Young’s Modulus Values

    by Resmi S L, Hashim V, Jesna Mohammed, Dileep P N

    Finite element analysis (FEA) stands as a cornerstone in preclinical investigations for implant therapy, particularly in orthopaedics and biomechanics. Accurate modelling of bone properties is crucial for meaningful FEA outcomes, considering the complex nature of bone tissue. This study proposes a novel approach by integrating CT‐based imaging data and machine learning to predict patient‐specific Young’s modulus values. A back propagation neural network (BPNN), incorporating texture properties extracted from CT images, demonstrates robustness in predicting Young’s modulus. Validation against three‐point bending experiments on rabbit femur bones shows promising results, with stress values within 13% of those from FEA. The proposed methodology holds the potential for enhancing preclinical evaluations of implant therapy and fostering the development of patient‐specific implants for improved clinical outcomes.

  • Open Access

    Bone Mineral Density Prediction from CT Image: A Novel Approach using ANN

    by S. L. Resmi, V. Hashim, Jesna Mohammed, P. N. Dileep

    Background. Though treatable, osteoporosis continues as a substantially underdiagnosed and undertreated condition. Bone mineral density (BMD) monitoring will definitely aid in the prediction and prevention of medical emergencies arising from osteoporosis. Although quantitative computed tomography (QCT) is one of the most widely accepted tools for measuring BMD, it lacks the contribution of bone architecture in predicting BMD, which is significant as aging progresses. This paper presents an innovative approach for the prediction of BMD incorporating bone architecture that involves no extra cost, time, and exposure to severe radiation. Methods. In this approach, the BMD is predicted using clinical CT scan images taken for other indications based on image processing and artificial neural network (ANN). The network used in this study is a standard backpropagation neural network having five input neurons with one hidden layer having 40 neurons with a tan-sigmoidal activation function. The Digital Imaging and Communications in Medicine (DICOM) image properties extracted from QCT of human skull and femur bone of rabbit that are closely associated with the BMD are used as input parameters of the ANN. The density value of the bone which is computed from the Hounsfield units of QCT scan image through phantom calibration is used as the target value for training the network. Results. The ANN model predicts the density values using the image properties from the clinical CT of the same rabbit femur bone and is compared with the density value computed from QCT scan. The correlation coefficient between predicted BMD and QCT density valued to 0.883. The proposed network can assist clinicians in identifying early stage of osteoporosis and devise suitable strategies to improve BMD with no additional cost.


  • Open Access

    Determination of the Influence of Strut Connector on Stent Deployment

    by V. Hashim, S. L. Resmi, P. N. Dileep

    Coronary artery stents are tubular structures employed together with angioplasty. Stented angioplasty is a clinical procedure widely applied in the treatment of atherosclerosis to reopen the blocked artery. It is a simple and fast curing minimally invasive clinical procedure. However, it is essential to understand the expansion characteristics of a stent before implantation since the stent geometry, inflating pressure, etc., influence the performance of stents. Finite element analysis and in vitro experiments are simultaneously employed before clinical testing to predict the characteristics during deployment. In this paper, the expansion and deployment characteristics of Meril Osum coronary stent and Envision stent were investigated to study the influence of strut connector on the expansion behaviour of the stent by experimental and computational methods. The current study analyzes the real-time deployment characteristics such as rate of expansion, stress on stent, recoil, dog boning, and foreshortening. The stent expansion characteristics obtained from experiments and simulations were found matching and observed that strut connector has a significant effect on stent expansion. Further, the curved connector of small radius of curvature shows better performance with high patency rate.