Lirui Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Lirui Xu has a total of 47 co-authors. Here are the top co-authors by number of shared publications:
- Lidong Du
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100190, China
7 shared publications - Zhen Fang
Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing 100094, China
6 shared publications - Pan Xia
Kunming University of Science and Technology
5 shared publications - Xianxiang Chen
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
4 shared publications - Pang Wu
Aerospace Information Research Institute, Chinese Academy of Sciences,Beijing,China,100094
3 shared publications Peng Wang
State Key Laboratory of Transducer Technology, Aerospace Information Research Institute, Chinese Academy of Sciences, Beijing, China
3 shared publications
Latest Publications
- Open Access
Coherent Target Cancellation and Deceptive Jamming Through a Multi-Region Time-Coding Metasurface
Existing metasurface-based radar countermeasures commonly manipulate echoes from metasurface-covered regions, whereas protecting exposed scattering centers that cannot accommodate metasurfaces remains challenging. This paper presents a multi-region time-coding metasurface (MRTCM) architecture for coherent target cancellation and deceptive jamming. The proposed system uses multiple independently controlled metasurface regions distributed over available platform surfaces. Each region generates zeroth-order and higher-order harmonic components through periodic phase modulation, and these components coherently combine with echoes from uncovered areas. The zeroth-order component is invariant under cyclic shifts of the coding sequence, enabling stable cancellation during multi-pulse coherent processing without locking radar-pulse arrival to the start of the coding cycle. Higher-order harmonics can shift the apparent range of the metasurface response and support cancellation at range-separated cells, but require accurate timing and synchronization. Numerical simulations demonstrate more than 40 dB suppression in high-resolution range profiles and validate the cancellation behavior under moving-target detection processing. The MRTCM architecture therefore provides a theoretically grounded framework for electromagnetic protection when full metasurface coverage is impractical.
Open AccessCoherent Target Cancellation and Deceptive Jamming Through a Multi-Region Time-Coding Metasurface
Existing metasurface-based radar countermeasures commonly manipulate echoes from metasurface-covered regions, whereas protecting exposed scattering centers that cannot accommodate metasurfaces remains challenging. This paper presents a multi-region time-coding metasurface (MRTCM) architecture for coherent target cancellation and deceptive jamming. The proposed system uses multiple independently controlled metasurface regions distributed over available platform surfaces. Each region generates zeroth-order and higher-order harmonic components through periodic phase modulation, and these components coherently combine with echoes from uncovered areas. The zeroth-order component is invariant under cyclic shifts of the coding sequence, enabling stable cancellation during multi-pulse coherent processing without locking radar-pulse arrival to the start of the coding cycle. Higher-order harmonics can shift the apparent range of the metasurface response and support cancellation at range-separated cells, but require accurate timing and synchronization. Numerical simulations demonstrate more than 40 dB suppression in high-resolution range profiles and validate the cancellation behavior under moving-target detection processing. The MRTCM architecture therefore provides a theoretically grounded framework for electromagnetic protection when full metasurface coverage is impractical.
- Open Access
- 8 March 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (3) , 151
Blood Pressure Estimation Through Pulse Wave Analysis Using Features Extracted from Carotid Diameter Distension Waveforms
Blood pressure estimation through pulse wave analysis (PWA) aims to establish the relationship between features of pulse waveforms and blood pressure. This study is the first to investigate the connection between features of carotid artery diameter waveforms and variations in blood pressure, as well as to develop a blood pressure estimation model based on these features. A dataset was constructed from 14 subjects, with data collected across various physiological states and time points. For each subject, carotid artery diameter waveforms were measured using ultrasound, while synchronous blood pressure data were recorded with a reference device. A total of 52 morphological features were extracted from the diameter waveforms and their first and second derivatives. The influence of different models and feature combinations on blood pressure estimation was analyzed using various machine learning approaches. Ultimately, optimal models were developed for each subject to dynamic blood pressure fluctuations. On independent test data where blood pressure fluctuations exceeded 25 mmHg, the mean absolute error (MAE) of the estimates was 3.3 ± 4.1 mmHg. Even after a period of two days or more, the models remained effective, yielding a MAE of 4.2 ± 5.3 mmHg.
- 8 March 2026
- Published by MDPI AG in Biosensors
- Vol. 16 (3) , 151
Open AccessBlood Pressure Estimation Through Pulse Wave Analysis Using Features Extracted from Carotid Diameter Distension Waveforms
Blood pressure estimation through pulse wave analysis (PWA) aims to establish the relationship between features of pulse waveforms and blood pressure. This study is the first to investigate the connection between features of carotid artery diameter waveforms and variations in blood pressure, as well as to develop a blood pressure estimation model based on these features. A dataset was constructed from 14 subjects, with data collected across various physiological states and time points. For each subject, carotid artery diameter waveforms were measured using ultrasound, while synchronous blood pressure data were recorded with a reference device. A total of 52 morphological features were extracted from the diameter waveforms and their first and second derivatives. The influence of different models and feature combinations on blood pressure estimation was analyzed using various machine learning approaches. Ultimately, optimal models were developed for each subject to dynamic blood pressure fluctuations. On independent test data where blood pressure fluctuations exceeded 25 mmHg, the mean absolute error (MAE) of the estimates was 3.3 ± 4.1 mmHg. Even after a period of two days or more, the models remained effective, yielding a MAE of 4.2 ± 5.3 mmHg.
- 1 April 2025
- Published by Tsinghua University Press in Tsinghua Science and Technology
- Vol. 30 (2) , 650-669
Wearable Continuous Blood Pressure Monitoring Based on Pulsatile Cycle Volume Adjustment Method
Accurate and portable Blood Pressure (BP) monitoring is vital for managing cardiovascular diseases. However, existing wearable continuous BP monitoring technologies are often inaccurate and rely on external calibration, limiting their practical application in continuous BP monitoring. To address this challenge, we have developed a Wearable continuous non-invasive BP Monitor (WeBPM) equipped with a finger cuff sensor, capable of monitoring BP continuously and accurately within medical-grade precision. WeBPM integrates advanced finger oscillographic BP measurement technology to provide reliable self-calibration functionality. Moreover, Pulsatile Cycle Volume Adjustment Method (PCVAM) we proposed for the closed-loop phase can continuously track changes in vasomotor tone under a controlled frequency based on pulsatile cycles, thereby enabling continuous BP measurement. In comparative experiments with the Nexfin monitor, WeBPM demonstrates excellent performance in induced dynamic BP experiments, with measurement errors of (-1.4 ± 6.24) mmHg for Systolic BP (SBP) and (-0.82 ± 4.83) mmHg for Diastolic BP (DBP). Additionally, compared to clinical invasive reference measurements, WeBPM's SBP and DBP measurement errors are (-1.74 ± 4.9) mmHg and (0.37 ± 3.28) mmHg, respectively, further proving its outstanding performance. These results highlight WeBPM's potential in personalized health management and remote monitoring, offering a new solution for continuous non-invasive BP monitoring.
- 1 April 2025
- Published by Tsinghua University Press in Tsinghua Science and Technology
- Vol. 30 (2) , 650-669
Wearable Continuous Blood Pressure Monitoring Based on Pulsatile Cycle Volume Adjustment Method
Accurate and portable Blood Pressure (BP) monitoring is vital for managing cardiovascular diseases. However, existing wearable continuous BP monitoring technologies are often inaccurate and rely on external calibration, limiting their practical application in continuous BP monitoring. To address this challenge, we have developed a Wearable continuous non-invasive BP Monitor (WeBPM) equipped with a finger cuff sensor, capable of monitoring BP continuously and accurately within medical-grade precision. WeBPM integrates advanced finger oscillographic BP measurement technology to provide reliable self-calibration functionality. Moreover, Pulsatile Cycle Volume Adjustment Method (PCVAM) we proposed for the closed-loop phase can continuously track changes in vasomotor tone under a controlled frequency based on pulsatile cycles, thereby enabling continuous BP measurement. In comparative experiments with the Nexfin monitor, WeBPM demonstrates excellent performance in induced dynamic BP experiments, with measurement errors of (-1.4 ± 6.24) mmHg for Systolic BP (SBP) and (-0.82 ± 4.83) mmHg for Diastolic BP (DBP). Additionally, compared to clinical invasive reference measurements, WeBPM's SBP and DBP measurement errors are (-1.74 ± 4.9) mmHg and (0.37 ± 3.28) mmHg, respectively, further proving its outstanding performance. These results highlight WeBPM's potential in personalized health management and remote monitoring, offering a new solution for continuous non-invasive BP monitoring.
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 18710-18724
Spatiotemporal 3-D Variations Modeling With Self-Attention for Multilabel ECG Classification
Multi-label electrocardiogram (ECG) classification is of great significance for the diagnosis of cardiovascular diseases, and it is also a challenging task because of the various of pathological patterns across different cardiac abnormalities. This paper analyzes the complex spatial-temporal variations information contained in the 12-lead ECG from a new perspective, and proposes an advanced deep neural network framework to accurately identify various multi-label ECG abnormalities. Firstly, the 12-lead ECG was modeled as 3-dimensional (3-D) spatial-temporal variations involving the intra-period, inter-period temporal dimensions, and cross-lead spatial dimension. Then, a 3-D spatial-temporal learning network (3D-STLNet) was carefully designed to extract the complex pathological features from the 3-D spatial-temporal variations. Secondly, the multi-head attention (MHA) mechanism was introduced into the proposed network to extract global temporal dependencies in ECG segments, which further improved the performance of the proposed network. By integrating a residual backbone network, a 3D-STLNet, and the MHA module, our proposed network allows end-to-end learning and prediction in a unified framework. The influence of several classic threshold selection strategies on the performance of multi-label ECG classification algorithm was also analyzed, which provides a reference for subsequent research on optimal threshold selection for multi-label ECG classification. Finally, our proposed network was evaluated on multiple large multi-label ECG public datasets, and the performance of our network outperforms that of current state-of-the-art networks, which demonstrates that our network has great competitiveness in identifying a wider range of multi-label ECG abnormalities.
- 26 April 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 24 (11) , 18710-18724
Spatiotemporal 3-D Variations Modeling With Self-Attention for Multilabel ECG Classification
Multi-label electrocardiogram (ECG) classification is of great significance for the diagnosis of cardiovascular diseases, and it is also a challenging task because of the various of pathological patterns across different cardiac abnormalities. This paper analyzes the complex spatial-temporal variations information contained in the 12-lead ECG from a new perspective, and proposes an advanced deep neural network framework to accurately identify various multi-label ECG abnormalities. Firstly, the 12-lead ECG was modeled as 3-dimensional (3-D) spatial-temporal variations involving the intra-period, inter-period temporal dimensions, and cross-lead spatial dimension. Then, a 3-D spatial-temporal learning network (3D-STLNet) was carefully designed to extract the complex pathological features from the 3-D spatial-temporal variations. Secondly, the multi-head attention (MHA) mechanism was introduced into the proposed network to extract global temporal dependencies in ECG segments, which further improved the performance of the proposed network. By integrating a residual backbone network, a 3D-STLNet, and the MHA module, our proposed network allows end-to-end learning and prediction in a unified framework. The influence of several classic threshold selection strategies on the performance of multi-label ECG classification algorithm was also analyzed, which provides a reference for subsequent research on optimal threshold selection for multi-label ECG classification. Finally, our proposed network was evaluated on multiple large multi-label ECG public datasets, and the performance of our network outperforms that of current state-of-the-art networks, which demonstrates that our network has great competitiveness in identifying a wider range of multi-label ECG abnormalities.
- Open Access
- 7 September 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 1053
A Fast Calibration Method for Pneumotachograph with a 3L Syringe
The pneumotachograph (PNT), a commonly used flowmeter in pulmonary function diagnostic equipment, is the required frequency calibration to maintain high accuracy. Aiming to simplify calibration steps, we developed a fast calibration system with a commercially available 3L syringe to provide a real output flow waveform. The acquisition of the real output flow waveform is based on the reliable measurement of in-cylinder pressure and the real-time detection of plunger speed. To improve the calibration accuracy, the tapping position for measuring in-cylinder pressure was optimized by CFD dynamic-mesh updating technique. The plunger speed was obtained by tracking the handle of the plunger with a smart terminal. Then, the real output flow was corrected using a compensation model equation. The calibration system was verified by the pulmonary waveform generator that the accuracy satisfied the requirements for respiratory flow measurement according to ATS standardization. The experimental results suggest that the developed method promises the fast calibration of PNT.
- 7 September 2023
- Published by MDPI AG in Bioengineering
- Vol. 10 (9) , 1053
Open AccessA Fast Calibration Method for Pneumotachograph with a 3L Syringe
The pneumotachograph (PNT), a commonly used flowmeter in pulmonary function diagnostic equipment, is the required frequency calibration to maintain high accuracy. Aiming to simplify calibration steps, we developed a fast calibration system with a commercially available 3L syringe to provide a real output flow waveform. The acquisition of the real output flow waveform is based on the reliable measurement of in-cylinder pressure and the real-time detection of plunger speed. To improve the calibration accuracy, the tapping position for measuring in-cylinder pressure was optimized by CFD dynamic-mesh updating technique. The plunger speed was obtained by tracking the handle of the plunger with a smart terminal. Then, the real output flow was corrected using a compensation model equation. The calibration system was verified by the pulmonary waveform generator that the accuracy satisfied the requirements for respiratory flow measurement according to ATS standardization. The experimental results suggest that the developed method promises the fast calibration of PNT.
- 26 July 2023
- Published by Elsevier in Measurement
- Vol. 220
Online continuous measurement of arterial pulse pressure and pressure waveform using ultrasound
- 26 July 2023
- Published by Elsevier in Measurement
- Vol. 220
Online continuous measurement of arterial pulse pressure and pressure waveform using ultrasound
- Open Access
Continuous and Noninvasive Measurement of Arterial Pulse Pressure and Pressure Waveform using an Image-free Ultrasound System
The local beat-to-beat local pulse pressure (PP) and blood pressure waveform of arteries, especially central arteries, are important indicators of the course of cardiovascular diseases (CVDs). Nevertheless, noninvasive measurement of them remains a challenge in the clinic. This work presents a three-element image-free ultrasound system with a low-computational method for real-time measurement of local pulse wave velocity (PWV) and diameter waveforms, enabling real-time and noninvasive continuous PP and blood pressure waveforms measurement without calibration. The developed system has been well-validated in vitro and in vivo. In in vitro cardiovascular phantom experiments, the results demonstrated high accuracy in the measurement of PP (error < 3 mmHg) and blood pressure waveform (root-mean-square-errors (RMSE) < 2 mmHg, correlation coefficient (r) > textgreater 0.99). In subsequent human carotid experiments, the system was compared with an arterial tonometer, which showed excellent PP accuracy (mean absolute error (MAE) = 3.7 +- 3.4 mmHg) and pressure waveform similarity (RMSE = 3.7 +- 1.6 mmHg, r = 0.98 +- 0.01). Furthermore, comparative experiments with the volume clamp device demonstrated the system's ability to accurately trace blood pressure changes (induced by deep breathing) over a period of one minute, with the MAE of DBP, MAP, and SBP within 5 +- 8 mmHg. The present results demonstrate the accuracy and reliability of the developed system for continuous and noninvasive measurement of arterial PP and blood pressure waveform measurements, with potential applications in the diagnosis and prevention of CVDs.
Open AccessContinuous and Noninvasive Measurement of Arterial Pulse Pressure and Pressure Waveform using an Image-free Ultrasound System
The local beat-to-beat local pulse pressure (PP) and blood pressure waveform of arteries, especially central arteries, are important indicators of the course of cardiovascular diseases (CVDs). Nevertheless, noninvasive measurement of them remains a challenge in the clinic. This work presents a three-element image-free ultrasound system with a low-computational method for real-time measurement of local pulse wave velocity (PWV) and diameter waveforms, enabling real-time and noninvasive continuous PP and blood pressure waveforms measurement without calibration. The developed system has been well-validated in vitro and in vivo. In in vitro cardiovascular phantom experiments, the results demonstrated high accuracy in the measurement of PP (error < 3 mmHg) and blood pressure waveform (root-mean-square-errors (RMSE) < 2 mmHg, correlation coefficient (r) > textgreater 0.99). In subsequent human carotid experiments, the system was compared with an arterial tonometer, which showed excellent PP accuracy (mean absolute error (MAE) = 3.7 +- 3.4 mmHg) and pressure waveform similarity (RMSE = 3.7 +- 1.6 mmHg, r = 0.98 +- 0.01). Furthermore, comparative experiments with the volume clamp device demonstrated the system's ability to accurately trace blood pressure changes (induced by deep breathing) over a period of one minute, with the MAE of DBP, MAP, and SBP within 5 +- 8 mmHg. The present results demonstrate the accuracy and reliability of the developed system for continuous and noninvasive measurement of arterial PP and blood pressure waveform measurements, with potential applications in the diagnosis and prevention of CVDs.
- Open Access
- 30 June 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (7) , 479
A Flexible Ultrasound Array for Local Pulse Wave Velocity Monitoring
Pulse wave velocity (PWV) measured at a specific artery location is called local PWV, which provides the elastic characteristics of arteries and indicates the degree of arterial stiffness. However, the large and cumbersome ultrasound probes require an appropriate sensor position and pressure maintenance, introducing usability constraints. In this paper, we developed a light (0.5 g) and thin (400 m) flexible ultrasound array by encapsulating 1–3 composite piezoelectric transducers with a silicone elastomer. It can capture the distension waveforms of four arterial positions with a spacing of 10 mm and calculate the local PWV by multi-point fitting. This is illustrated by in vivo experiments, where the local PWV value of five normal subjects ranged from 3.07 to 4.82 m/s, in agreement with earlier studies. The beat-to-beat coefficient of variation (CV) is 12.0% ± 3.5%, showing high reliability. High reproducibility is shown by the results of two groups of independent measurements of three subjects (the error between the mean values is less than 0.3 m/s). These properties of the developed flexible ultrasound array enable the bandage-like application of local PWV monitoring to skin surfaces.- 30 June 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (7) , 479
Open AccessA Flexible Ultrasound Array for Local Pulse Wave Velocity Monitoring
Pulse wave velocity (PWV) measured at a specific artery location is called local PWV, which provides the elastic characteristics of arteries and indicates the degree of arterial stiffness. However, the large and cumbersome ultrasound probes require an appropriate sensor position and pressure maintenance, introducing usability constraints. In this paper, we developed a light (0.5 g) and thin (400 m) flexible ultrasound array by encapsulating 1–3 composite piezoelectric transducers with a silicone elastomer. It can capture the distension waveforms of four arterial positions with a spacing of 10 mm and calculate the local PWV by multi-point fitting. This is illustrated by in vivo experiments, where the local PWV value of five normal subjects ranged from 3.07 to 4.82 m/s, in agreement with earlier studies. The beat-to-beat coefficient of variation (CV) is 12.0% ± 3.5%, showing high reliability. High reproducibility is shown by the results of two groups of independent measurements of three subjects (the error between the mean values is less than 0.3 m/s). These properties of the developed flexible ultrasound array enable the bandage-like application of local PWV monitoring to skin surfaces.