Владимир Анатольевич Сурин
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Владимир Анатольевич Сурин has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Anton Veniaminovich Korzhov
Южно-Уральский государственный университет
3 shared publications - P.V. Lonzinger
Южно-Уральский государственный университет
3 shared publications South Ural State University
3 shared publications- V.I. Safonov
Южно-Уральский государственный университет
3 shared publications - Кирилл Николаевич Белов
Южно-Уральский государственный университет
3 shared publications - Ya. V. Bushmelev
South Ural State University
2 shared publications
Latest Publications
- Open Access
- 1 January 2025
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Power Engineering"
- Vol. 25 (3) , 13-21
THE USE OF FUZZY SETS TO CREATE A DATASET FOR A NEURAL NETWORK ASSESSING THE HAZARD OF GLASS INSULATOR DEFECTS
The article considers the formation of a calculation model for assessing the hazard of 1–2 mm air inclu-sions in glass parts of PS-70E (U70) insulators. The model includes fuzzy sets for the following input variables: defect size, distance from the part axis to the defect center, position of the defect center. The hazard of defects was assessed using the Mamdani algorithm based on the obtained model. The calculation results were verified based on the calculation of electric field distribution patterns. The article shows that the calculation model allows for the correct classification of defects for the considered examples in terms of the hazard of electrical strength failures. The developed model can be improved by expanding its generalizing ability to other types of defects and boundaries of glass parts. Given the expected performance accuracy, the model can be used to form training data for a neural network able to assess the hazard of potential defects in terms of electrical strength failures based on the images of glass parts. Рассматривается формирование расчетной модели для оценки опасности воздушных включений диаметрами от 1 до 2 мм в стеклянных деталях изоляторов марки ПС-70Е. В состав модели входят нечеткие множества для входных переменных: размер дефекта, расстояние от оси детали до центра дефекта, положение центра дефекта. С использованием алгоритма Мамдани на основе полученной модели проведена оценка опасности дефектов. Результаты расчета были верифицированы на основе расчета картин распределения электрического поля. Показано, что для рассмотренных примеров расчетная модель позволяет проводить правильную классификацию дефектов с точки зрения опасности нарушения электрической прочности. Разработанная модель может быть улучшена путем расширения ее обобщающей способности на другие разновидности дефектов и виды границ стеклянных деталей. При обеспечении ожидаемой точности работы модели возможно формирование с ее помощью обучающих данных для нейронной сети, способной по изображениям стеклянных деталей формировать оценку опасности потенциальных дефектов с точки зрения нарушения электрической прочности.
- 1 January 2025
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Power Engineering"
- Vol. 25 (3) , 13-21
Open AccessTHE USE OF FUZZY SETS TO CREATE A DATASET FOR A NEURAL NETWORK ASSESSING THE HAZARD OF GLASS INSULATOR DEFECTS
The article considers the formation of a calculation model for assessing the hazard of 1–2 mm air inclu-sions in glass parts of PS-70E (U70) insulators. The model includes fuzzy sets for the following input variables: defect size, distance from the part axis to the defect center, position of the defect center. The hazard of defects was assessed using the Mamdani algorithm based on the obtained model. The calculation results were verified based on the calculation of electric field distribution patterns. The article shows that the calculation model allows for the correct classification of defects for the considered examples in terms of the hazard of electrical strength failures. The developed model can be improved by expanding its generalizing ability to other types of defects and boundaries of glass parts. Given the expected performance accuracy, the model can be used to form training data for a neural network able to assess the hazard of potential defects in terms of electrical strength failures based on the images of glass parts. Рассматривается формирование расчетной модели для оценки опасности воздушных включений диаметрами от 1 до 2 мм в стеклянных деталях изоляторов марки ПС-70Е. В состав модели входят нечеткие множества для входных переменных: размер дефекта, расстояние от оси детали до центра дефекта, положение центра дефекта. С использованием алгоритма Мамдани на основе полученной модели проведена оценка опасности дефектов. Результаты расчета были верифицированы на основе расчета картин распределения электрического поля. Показано, что для рассмотренных примеров расчетная модель позволяет проводить правильную классификацию дефектов с точки зрения опасности нарушения электрической прочности. Разработанная модель может быть улучшена путем расширения ее обобщающей способности на другие разновидности дефектов и виды границ стеклянных деталей. При обеспечении ожидаемой точности работы модели возможно формирование с ее помощью обучающих данных для нейронной сети, способной по изображениям стеклянных деталей формировать оценку опасности потенциальных дефектов с точки зрения нарушения электрической прочности.
- 1 January 2025
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Power Engineering"
- Vol. 25 (2) , 17-24
USING OF SURROGATE MODELS OF ELECTROPHYSICAL CHARACTERISTICS FOR THE DESIGN OF HIGH-VOLTAGE INSULATORS, TAKING INTO ACCOUNT THE POTENTIAL PRESENCE OF DEFECTS
The article is devoted to the construction of surrogate models as a tool for assessing the influence of the properties of materials of insulating structures and the defects present in them, the geometry of insulating structures, on the electrical strength in the area of the defect location. Using the example of a glass part of the PS-70E (U70) insulator, it is shown that a surrogate model in the form of a polynomial of four seventh-order variables, which takes into account changes in the dielectric permittivity and specific conductivities of the model materials, is sufficient to analyze the electrical strength in the area of the defect location when the properties of materials change. The relative error in determining the electric field based on the results of simulation modeling and calculation using the surrogate model is no more than 11.2% and 10.7% for the maximum and minimum electric field strengths in the defect, respectively. It is shown that the dielectric constant of the substance of the insulating structure has a significant effect on the field strength only when the permeability of the defect substance is less than 6, which is typical for defects in the form of gas inclusions. The change in the characteristics of the field in the defect, depending on the geometry of the structure, was also considered using the example of the head of the glass part of the PS-70E insulator. The change in geometry was studied at different values of the amplitudes of the first spatial harmonics of the forming boundaries with a simultaneous change in the location of the spherical defect inside the structure. It is shown that in this case, a polynomial of 5 degrees of 4 variables is sufficient to construct a surrogate model. The maximum margin of error is no more than 7.6%. The analysis of the dependences of the field strengths inside the defect in the considered surrogate models, as well as in the obtained model, suggests that defects in high-voltage insulators ranging in size from 0.1 to 2 mm can be considered potentially dangerous. Статья посвящена построению суррогатных моделей как инструменту оценки влияния свойств материалов изоляционных конструкций и присутствующих в них дефектов, геометрии изоляционных конструкций, на электрическую прочность в области расположения дефекта. На примере стеклянной детали изолятора ПС-70Е показано, что для анализа электрической прочности в области расположения дефекта при изменении свойств материалов достаточно суррогатной модели в виде полинома четырех переменных седьмого порядка, учитывающей изменение диэлектрических проницаемостей и удельных проводимостей материалов модели. Относительная ошибка в определении электрического поля по результатам имитационного моделирования и расчета по суррогатной модели составляет не более 11,2% и 10,7% для максимальной и минимальной напряженности электрического поля в дефекте соответственно. Показано, что диэлектрическая проницаемость вещества изоляционной конструкции оказывает существенное влияние на напряженность поля только при проницаемостях вещества дефекта, меньших 6, что характерно для дефектов в виде газовых включений. Изменение характеристик поля в дефекте в зависимости от геометрии конструкции рассматривалось также на примере головки стеклянной детали изолятора ПС-70Е. Изменение геометрии изучалось при различных значениях амплитуд первых пространственных гармоник образующих границ с одновременным изменением расположения сферического дефекта внутри конструкции. Показано, что для построения суррогатной модели в этом случае достаточно полинома 5 степени 4 переменных. Максимальная погрешность при этом составляет не более 7,6%. Анализ зависимостей напряженностей поля внутри дефекта в рассматриваемых суррогатных моделях, а также в полученной ранее модели, позволяет утверждать, что потенциально опасными могут считаться дефекты в высоковольтных изоляторах размерами от 0,1 до 2 мм.
- 1 January 2025
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Power Engineering"
- Vol. 25 (2) , 17-24
USING OF SURROGATE MODELS OF ELECTROPHYSICAL CHARACTERISTICS FOR THE DESIGN OF HIGH-VOLTAGE INSULATORS, TAKING INTO ACCOUNT THE POTENTIAL PRESENCE OF DEFECTS
The article is devoted to the construction of surrogate models as a tool for assessing the influence of the properties of materials of insulating structures and the defects present in them, the geometry of insulating structures, on the electrical strength in the area of the defect location. Using the example of a glass part of the PS-70E (U70) insulator, it is shown that a surrogate model in the form of a polynomial of four seventh-order variables, which takes into account changes in the dielectric permittivity and specific conductivities of the model materials, is sufficient to analyze the electrical strength in the area of the defect location when the properties of materials change. The relative error in determining the electric field based on the results of simulation modeling and calculation using the surrogate model is no more than 11.2% and 10.7% for the maximum and minimum electric field strengths in the defect, respectively. It is shown that the dielectric constant of the substance of the insulating structure has a significant effect on the field strength only when the permeability of the defect substance is less than 6, which is typical for defects in the form of gas inclusions. The change in the characteristics of the field in the defect, depending on the geometry of the structure, was also considered using the example of the head of the glass part of the PS-70E insulator. The change in geometry was studied at different values of the amplitudes of the first spatial harmonics of the forming boundaries with a simultaneous change in the location of the spherical defect inside the structure. It is shown that in this case, a polynomial of 5 degrees of 4 variables is sufficient to construct a surrogate model. The maximum margin of error is no more than 7.6%. The analysis of the dependences of the field strengths inside the defect in the considered surrogate models, as well as in the obtained model, suggests that defects in high-voltage insulators ranging in size from 0.1 to 2 mm can be considered potentially dangerous. Статья посвящена построению суррогатных моделей как инструменту оценки влияния свойств материалов изоляционных конструкций и присутствующих в них дефектов, геометрии изоляционных конструкций, на электрическую прочность в области расположения дефекта. На примере стеклянной детали изолятора ПС-70Е показано, что для анализа электрической прочности в области расположения дефекта при изменении свойств материалов достаточно суррогатной модели в виде полинома четырех переменных седьмого порядка, учитывающей изменение диэлектрических проницаемостей и удельных проводимостей материалов модели. Относительная ошибка в определении электрического поля по результатам имитационного моделирования и расчета по суррогатной модели составляет не более 11,2% и 10,7% для максимальной и минимальной напряженности электрического поля в дефекте соответственно. Показано, что диэлектрическая проницаемость вещества изоляционной конструкции оказывает существенное влияние на напряженность поля только при проницаемостях вещества дефекта, меньших 6, что характерно для дефектов в виде газовых включений. Изменение характеристик поля в дефекте в зависимости от геометрии конструкции рассматривалось также на примере головки стеклянной детали изолятора ПС-70Е. Изменение геометрии изучалось при различных значениях амплитуд первых пространственных гармоник образующих границ с одновременным изменением расположения сферического дефекта внутри конструкции. Показано, что для построения суррогатной модели в этом случае достаточно полинома 5 степени 4 переменных. Максимальная погрешность при этом составляет не более 7,6%. Анализ зависимостей напряженностей поля внутри дефекта в рассматриваемых суррогатных моделях, а также в полученной ранее модели, позволяет утверждать, что потенциально опасными могут считаться дефекты в высоковольтных изоляторах размерами от 0,1 до 2 мм.
- Open Access
- 1 January 2024
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Power Engineering"
- Vol. 24 (4) , 13-22
SURROGATE MODELS OF ELECTROPHYSICAL CHARACTERISTICS OF GLASS PARTS OF HIGH-VOLTAGE INSULATORS
The article is devoted to the development of a surrogate model as an element of a computer vision system to identify internal defects in insulating parts of complex shape. To analyze the electrophysical characteristics of high-voltage insulators with defects, the principles of optimal construction of a physical model necessary to obtain simulation data are determined. A set of functional dependencies for the analysis of the electrical strength of the sample and the principles of selecting arguments for these dependencies are also defined. Using the example of a glass part of the PS-70E insulator, it has been shown that a numerical model in the form of a polynomial of five seventh-order variables, taking into account the change in the shape of elliptical gas inclusions and their distribution, is sufficient to analyze the electrical strength of the insulator. The relative error in determining the main characteristics of the electric field in the defect based on the results of simulation modeling and calculation using a surrogate model is no more than 10%. The use of a surrogate model makes it possible to identify areas for which the maximum electric field strength will be observed in defects, which makes it possible for the computer vision system to assess the potential danger of defects. Using the polynomial form of the surrogate model simplifies the process of creating a model, since the construction algorithm is deterministic. This advantage can be used in the construction of surrogate models of insulation structures, since their physical properties are sufficiently homogeneous throughout the entire product and they can be approximated by a polynomial function of a small degree. Also, the advantage of the polynomial model was determined by the relative simplicity of obtaining simulation data. Статья посвящена построению суррогатной модели как элементу системы технического зрения для выявления внутренних дефектов в изоляционных деталях сложной формы. Для анализа электрофизических характеристик высоковольтных изоляторов с дефектами определены принципы оптимального построения физической модели, необходимой для получения имитационных данных. Также определен набор функциональных зависимостей для анализа электрической прочности образца и принципы подбора аргументов этих зависимостей. На примере стеклянной детали изолятора ПС-70Е показано, что для анализа электрической прочности изолятора достаточно суррогатной модели в виде полинома пяти переменных седьмого порядка, учитывающей изменение формы эллиптических газовых включений и их расположение. Относительная ошибка в определении основных характеристик электрического поля в дефекте по результатам имитационного моделирования и расчета по суррогатной модели составляет не более 10%. Использование суррогатной модели позволяет выявить области, для которых в дефектах будет наблюдаться максимальная напряженность электрического поля, что дает возможность системе технического зрения оценивать потенциальную опасность дефектов. Использование полиномиальной формы суррогатной модели упрощает процесс создания модели, поскольку алгоритм построения имеет детерминированный характер. Указанное преимущество можно использовать при построении суррогатных моделей изоляционных конструкций, поскольку их физические свойства достаточно однородны во всем изделии и их можно аппроксимировать полиномиальной функцией небольшой степени. Также преимущество полиномиальной модели определялось относительной простотой получения данных имитационного моделирования.
- 1 January 2024
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Power Engineering"
- Vol. 24 (4) , 13-22
Open AccessSURROGATE MODELS OF ELECTROPHYSICAL CHARACTERISTICS OF GLASS PARTS OF HIGH-VOLTAGE INSULATORS
The article is devoted to the development of a surrogate model as an element of a computer vision system to identify internal defects in insulating parts of complex shape. To analyze the electrophysical characteristics of high-voltage insulators with defects, the principles of optimal construction of a physical model necessary to obtain simulation data are determined. A set of functional dependencies for the analysis of the electrical strength of the sample and the principles of selecting arguments for these dependencies are also defined. Using the example of a glass part of the PS-70E insulator, it has been shown that a numerical model in the form of a polynomial of five seventh-order variables, taking into account the change in the shape of elliptical gas inclusions and their distribution, is sufficient to analyze the electrical strength of the insulator. The relative error in determining the main characteristics of the electric field in the defect based on the results of simulation modeling and calculation using a surrogate model is no more than 10%. The use of a surrogate model makes it possible to identify areas for which the maximum electric field strength will be observed in defects, which makes it possible for the computer vision system to assess the potential danger of defects. Using the polynomial form of the surrogate model simplifies the process of creating a model, since the construction algorithm is deterministic. This advantage can be used in the construction of surrogate models of insulation structures, since their physical properties are sufficiently homogeneous throughout the entire product and they can be approximated by a polynomial function of a small degree. Also, the advantage of the polynomial model was determined by the relative simplicity of obtaining simulation data. Статья посвящена построению суррогатной модели как элементу системы технического зрения для выявления внутренних дефектов в изоляционных деталях сложной формы. Для анализа электрофизических характеристик высоковольтных изоляторов с дефектами определены принципы оптимального построения физической модели, необходимой для получения имитационных данных. Также определен набор функциональных зависимостей для анализа электрической прочности образца и принципы подбора аргументов этих зависимостей. На примере стеклянной детали изолятора ПС-70Е показано, что для анализа электрической прочности изолятора достаточно суррогатной модели в виде полинома пяти переменных седьмого порядка, учитывающей изменение формы эллиптических газовых включений и их расположение. Относительная ошибка в определении основных характеристик электрического поля в дефекте по результатам имитационного моделирования и расчета по суррогатной модели составляет не более 10%. Использование суррогатной модели позволяет выявить области, для которых в дефектах будет наблюдаться максимальная напряженность электрического поля, что дает возможность системе технического зрения оценивать потенциальную опасность дефектов. Использование полиномиальной формы суррогатной модели упрощает процесс создания модели, поскольку алгоритм построения имеет детерминированный характер. Указанное преимущество можно использовать при построении суррогатных моделей изоляционных конструкций, поскольку их физические свойства достаточно однородны во всем изделии и их можно аппроксимировать полиномиальной функцией небольшой степени. Также преимущество полиномиальной модели определялось относительной простотой получения данных имитационного моделирования.
- Open Access
- 1 January 2023
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Mathematics. Mechanics. Physics"
- Vol. 15 (4) , 21-29
RAW IMAGE FILTERING BASED ON THE GENERALIZED METHOD OF LEAST MODULES
Рассматриваются необработанные RAW-изображения, получаемые с фотоматрицы. Цель работы – адаптировать фильтр на основе обобщенного метода наименьших модулей (ОМНМ) для фильтрации RAW-изображений с цифровых камер. Цифровые изображения, получаемые при оцифровке аналогового сигнала цифровой фотоматрицей, помимо полезного сигнала имеют шумовую составляющую. Кроме того, структура изображения, полученная напрямую с цифровой матрицы, сильно отличается от привычного RGB-изображения. Для получения RGB-изображения необходимо применить интерполяционный алгоритм, называемый демозаикой, которая вносит дополнительные искажения. Предлагается производить фильтрацию полученного изображения до применения алгоритма демозаики. RAW-изображения используют большее количество бит для описания яркости каждого пикселя, чем стандартные RGB-изображения, и имеют другую структуру. Для работы с такими изображениями требуется адаптация существующих цифровых фильтров. Для ОМНМ-фильтрации подобраны коэфициенты для параметров функции сглаживающего преобразования. Показаны преимущества фильтрации RAW-изображений, по сравнению со стандартными RGB-изображениями, а также сравнение ОМНМ с усредняющей и медианной фильтрацией. На основе полученных зависимостей решена практическая задача по повышению контрастности изображений стеклянных изоляторах на основе их RAW-снимков для последующего обнаружения дефектов в изоляторах.
- 1 January 2023
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Mathematics. Mechanics. Physics"
- Vol. 15 (4) , 21-29
Open AccessRAW IMAGE FILTERING BASED ON THE GENERALIZED METHOD OF LEAST MODULES
Рассматриваются необработанные RAW-изображения, получаемые с фотоматрицы. Цель работы – адаптировать фильтр на основе обобщенного метода наименьших модулей (ОМНМ) для фильтрации RAW-изображений с цифровых камер. Цифровые изображения, получаемые при оцифровке аналогового сигнала цифровой фотоматрицей, помимо полезного сигнала имеют шумовую составляющую. Кроме того, структура изображения, полученная напрямую с цифровой матрицы, сильно отличается от привычного RGB-изображения. Для получения RGB-изображения необходимо применить интерполяционный алгоритм, называемый демозаикой, которая вносит дополнительные искажения. Предлагается производить фильтрацию полученного изображения до применения алгоритма демозаики. RAW-изображения используют большее количество бит для описания яркости каждого пикселя, чем стандартные RGB-изображения, и имеют другую структуру. Для работы с такими изображениями требуется адаптация существующих цифровых фильтров. Для ОМНМ-фильтрации подобраны коэфициенты для параметров функции сглаживающего преобразования. Показаны преимущества фильтрации RAW-изображений, по сравнению со стандартными RGB-изображениями, а также сравнение ОМНМ с усредняющей и медианной фильтрацией. На основе полученных зависимостей решена практическая задача по повышению контрастности изображений стеклянных изоляторах на основе их RAW-снимков для последующего обнаружения дефектов в изоляторах.
- Open Access
- 1 January 2021
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Mathematics. Mechanics. Physics"
- Vol. 13 (1) , 14-21
ON PROCESSING NOISY CONTRAST IMAGES
The problem of noise reduction at sharp transitions of brightness in digital noisy contrast images is considered. In addition to the useful signal, digital images obtained by digitizing an analogue signal with a digital photo matrix have a noise component. Moreover, to obtain a digital image in the standard RGB color model, a demosaicing interpolation algorithm must be applied to the image obtained from a digital photo matrix. Due to such transformations, the Gaussian distribution of noise in a digital noisy image is violated. Using a standard image digitization model for noise reduction is not effective. For more effective noise reduction, the digital image is transferred from the RGB color model to the HSV or LAB color model, where the brightness and color components of the digital noise can be filtered separately. Color noise is suppressed in the color channels of the image using a Gaussian filter. Noise reduction in the brightness channel of a digital image is more difficult task, especially at the edge of sharp transitions of brightness. To suppress the brightness noise in contrast images, it is proposed to use a nonlinear filter based on the generalized method of least absolute values (GMLAV). The process of smoothing the contrast noisy transition by the GMLAV-filter is described, and its efficiency is shown in comparison with the median filtration.
- 1 January 2021
- Published by FSAEIHE South Ural State University (National Research University) in Bulletin of the South Ural State University Series "Mathematics. Mechanics. Physics"
- Vol. 13 (1) , 14-21
Open AccessON PROCESSING NOISY CONTRAST IMAGES
The problem of noise reduction at sharp transitions of brightness in digital noisy contrast images is considered. In addition to the useful signal, digital images obtained by digitizing an analogue signal with a digital photo matrix have a noise component. Moreover, to obtain a digital image in the standard RGB color model, a demosaicing interpolation algorithm must be applied to the image obtained from a digital photo matrix. Due to such transformations, the Gaussian distribution of noise in a digital noisy image is violated. Using a standard image digitization model for noise reduction is not effective. For more effective noise reduction, the digital image is transferred from the RGB color model to the HSV or LAB color model, where the brightness and color components of the digital noise can be filtered separately. Color noise is suppressed in the color channels of the image using a Gaussian filter. Noise reduction in the brightness channel of a digital image is more difficult task, especially at the edge of sharp transitions of brightness. To suppress the brightness noise in contrast images, it is proposed to use a nonlinear filter based on the generalized method of least absolute values (GMLAV). The process of smoothing the contrast noisy transition by the GMLAV-filter is described, and its efficiency is shown in comparison with the median filtration.