Lucian Fasselt
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lucian Fasselt has a total of 138 co-authors. Here are the top co-authors by number of shared publications:
- Carlos Antonio Solans Sanchez
CERN
6 shared publications - Laura Gonella
Dipartimento di Fisica dell’Università and Sezione INFN
6 shared publications - Dumitru Vlad Berlea
Deutsches Elektronen-Synchrotron DESY, Zeuthen, Germany
5 shared publications Milou van Rijnbach
5 shared publications- Petra Riedler
CERN
5 shared publications - Tomohiro Inada
Kyushu University, 744 Motooka, Nishi-ku, 819-0395 Fukuoka, Japan
5 shared publications
Latest Publications
- Open Access
- 28 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7) , 890
Design optimization of MAPS-based detectors using a data-driven fast simulation approach
A parametric simulation tool for pixel sensors is presented. A realistic pixel response is simulated purely based on measurement input, without requiring detailed knowledge of the underlying manufacturing process. As such, it provides an efficient alternative to the use of Technology Computer-Aided Design simulations, which typically depend on proprietary process information. Due to its parametric approach, the package is fast and thus particularly useful for larger detector systems and high hit rate environments. This work presents measurements, simulation and its validation for the MALTA2 sensor. It is a small collection electrode monolithic active pixel sensor produced in the Tower 180 nm complementary metal-oxide-semiconductor imaging process. Modifications to the sensor’s periphery, mainly in the hit merger, are studied in order to optimize the performance for tracking and calorimetry. This optimization is of special interest as part of the MALTA3 sensor redesign in the 65 nm Tower Partners Semiconductor Co. process.
- 28 July 2026
- Published by Springer Nature in The European Physical Journal C
- Vol. 86 (7) , 890
Open AccessDesign optimization of MAPS-based detectors using a data-driven fast simulation approach
A parametric simulation tool for pixel sensors is presented. A realistic pixel response is simulated purely based on measurement input, without requiring detailed knowledge of the underlying manufacturing process. As such, it provides an efficient alternative to the use of Technology Computer-Aided Design simulations, which typically depend on proprietary process information. Due to its parametric approach, the package is fast and thus particularly useful for larger detector systems and high hit rate environments. This work presents measurements, simulation and its validation for the MALTA2 sensor. It is a small collection electrode monolithic active pixel sensor produced in the Tower 180 nm complementary metal-oxide-semiconductor imaging process. Modifications to the sensor’s periphery, mainly in the hit merger, are studied in order to optimize the performance for tracking and calorimetry. This optimization is of special interest as part of the MALTA3 sensor redesign in the 65 nm Tower Partners Semiconductor Co. process.
- Open Access
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04001
Charge collection parameterization of MALTA2, a depleted monolithic active pixel sensor
A fast simulation method is presented for a depleted monolithic active pixel sensor, which uses a data driven parameterization of the charge collection and propagation. This approach provides an efficient alternative to TCAD simulations, particularly for sensors whose proprietary process details — such as doping profiles or implant geometries — are unavailable. Data was obtained with a MALTA2 sensor fabricated in a 180 nm CMOS imaging technology on 30 µm epitaxial silicon using the MALTA beam telescope at CERN SPS. The model reproduces the measured in-pixel efficiency with high accuracy and enables a realistic yet computationally lightweight analog pixel simulation. This method will be further employed in optimizing the digital sensor design for applications in high-rate particle tracking and high-granularity calorimetry.
- 1 April 2026
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 21 (04) , C04001
Open AccessCharge collection parameterization of MALTA2, a depleted monolithic active pixel sensor
A fast simulation method is presented for a depleted monolithic active pixel sensor, which uses a data driven parameterization of the charge collection and propagation. This approach provides an efficient alternative to TCAD simulations, particularly for sensors whose proprietary process details — such as doping profiles or implant geometries — are unavailable. Data was obtained with a MALTA2 sensor fabricated in a 180 nm CMOS imaging technology on 30 µm epitaxial silicon using the MALTA beam telescope at CERN SPS. The model reproduces the measured in-pixel efficiency with high accuracy and enables a realistic yet computationally lightweight analog pixel simulation. This method will be further employed in optimizing the digital sensor design for applications in high-rate particle tracking and high-granularity calorimetry.
- Open Access
- 11 September 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1082
Charge calibration of MALTA2, a radiation hard depleted monolithic active pixel sensor
- 11 September 2025
- Published by Elsevier in Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment
- Vol. 1082
Open AccessCharge calibration of MALTA2, a radiation hard depleted monolithic active pixel sensor
- Open Access
- 1 September 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (09) , P09039
Timing characterization of MALTA and MALTA2 pixel detectors using Micro X-ray source
The MALTA monolithic active pixel detector is developed to address some of the challenges anticipated in future high-energy physics detectors. As part of its characterization, we conducted timing studies necessary to provide a figure of merit for this family of monolithic pixel detectors. MALTA has a metal layer in front-end electronics, and the conventional laser technique is not suitable for timing studies due to the reflection of the laser from the metallic surface. X-rays have been employed as a more effective alternative for penetration through these layers. The triggered X-ray set-up is designed to study timing measurements of monolithic detectors. The timing response of the X-ray set-up is characterized using an LGAD. The timing response of the MALTA and MALTA2 pixel detectors is studied, and the best response time of MALTA2 pixel detectors is measured at about 2.6 ns.
- 1 September 2025
- Published by IOP Publishing in Journal of Instrumentation
- Vol. 20 (09) , P09039
Open AccessTiming characterization of MALTA and MALTA2 pixel detectors using Micro X-ray source
The MALTA monolithic active pixel detector is developed to address some of the challenges anticipated in future high-energy physics detectors. As part of its characterization, we conducted timing studies necessary to provide a figure of merit for this family of monolithic pixel detectors. MALTA has a metal layer in front-end electronics, and the conventional laser technique is not suitable for timing studies due to the reflection of the laser from the metallic surface. X-rays have been employed as a more effective alternative for penetration through these layers. The triggered X-ray set-up is designed to study timing measurements of monolithic detectors. The timing response of the X-ray set-up is characterized using an LGAD. The timing response of the MALTA and MALTA2 pixel detectors is studied, and the best response time of MALTA2 pixel detectors is measured at about 2.6 ns.
- Open Access
Charge calibration of MALTA2, a radiation hard depleted monolithic active pixel sensor
MALTA2 is a depleted monolithic active pixel sensor (DMAPS) designed for tracking at high rates and typically low detection threshold of $\sim150\,\mathrm{e^-}$. A precise knowledge of the threshold is crucial to understanding the charge collection in the pixel and specifying the environment for sensor application. A simple procedure is developed to calibrate the threshold to unit electrons making use of a dedicated charge injection circuit and an Fe-55 source with dominant charge deposition of $1600\, \mathrm{e^-}$. The injection voltage is determined which corresponds to the injection under Fe-55 exposure and is the basis for charge calibration. The charge injection circuit incorporates a capacitance with design value of $\mathrm{C_{inj}}=$ 230 aF. Experimentally, the average capacitance value for non-irradiated samples is found to be $\mathrm{C_{inj,exp}}=$ 257 aF. The 12 % divergence motivates the need for the presented precise calibration procedure, which is proposed to be performed for each MALTA2 sensor.Open AccessCharge calibration of MALTA2, a radiation hard depleted monolithic active pixel sensor
MALTA2 is a depleted monolithic active pixel sensor (DMAPS) designed for tracking at high rates and typically low detection threshold of $\sim150\,\mathrm{e^-}$. A precise knowledge of the threshold is crucial to understanding the charge collection in the pixel and specifying the environment for sensor application. A simple procedure is developed to calibrate the threshold to unit electrons making use of a dedicated charge injection circuit and an Fe-55 source with dominant charge deposition of $1600\, \mathrm{e^-}$. The injection voltage is determined which corresponds to the injection under Fe-55 exposure and is the basis for charge calibration. The charge injection circuit incorporates a capacitance with design value of $\mathrm{C_{inj}}=$ 230 aF. Experimentally, the average capacitance value for non-irradiated samples is found to be $\mathrm{C_{inj,exp}}=$ 257 aF. The 12 % divergence motivates the need for the presented precise calibration procedure, which is proposed to be performed for each MALTA2 sensor. - Open Access
- 17 October 2023
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 11, 1231336
Energy calibration through X-ray absorption of the DECAL sensor, a monolithic active pixel sensor prototype for digital electromagnetic calorimetry and tracking
In calorimetry, the predominant detection principle is to measure the energy deposited by particles within a shower initiated by an incident particle. An alternative concept is a sampling calorimeter where the highly granular active layers rather measure the number of secondary particles in the shower by detecting hits through binary readout similar to sensors for tracking applications. In this context, the DECAL sensor is a fully-depleted monolithic active pixel sensor prototype with reconfigurable readout for digital electromagnetic calorimetry and tracking. Its 64 × 64 pixels with a pitch of 55 µm are fabricated in a modified TowerJazz 180 nm CMOS imaging process using a 25 µm epitaxial silicon layer. The readout at 40 MHz is configurable in counting hits in the sensor grouped as either 64 strips or 4 pads. In this article, we present the energy calibration of this sensor using a gamma source of americium-241 as well as X-ray fluorescence at various wavelengths. The uniformity of the pixel responses is shown, allowing the summation of counts across all pixels. By that, two standalone energy calibration methods are developed that describe the X-ray absorption in the energy range of 4–60 keV and agree with each other. The signal pulse height is related to the absorbed photon energy with a 5.54 ± 0.37 mV/keV scale which corresponds to a conversion gain of cg = 19.95 ± 1.32 μV/e−. The relative energy resolution for photon absorption is found to be σE/E = 11.8 ± 3.0%. The absolute counts observed with the DECAL sensor agree with expectations and substantiate the assumption of a fully depleted epitaxial layer. The understanding of the photon absorption is an important input for further development of the sensor towards a multi-layer calorimeter.
- 17 October 2023
- Published by Frontiers Media SA in Frontiers in Physics
- Vol. 11, 1231336
Open AccessEnergy calibration through X-ray absorption of the DECAL sensor, a monolithic active pixel sensor prototype for digital electromagnetic calorimetry and tracking
In calorimetry, the predominant detection principle is to measure the energy deposited by particles within a shower initiated by an incident particle. An alternative concept is a sampling calorimeter where the highly granular active layers rather measure the number of secondary particles in the shower by detecting hits through binary readout similar to sensors for tracking applications. In this context, the DECAL sensor is a fully-depleted monolithic active pixel sensor prototype with reconfigurable readout for digital electromagnetic calorimetry and tracking. Its 64 × 64 pixels with a pitch of 55 µm are fabricated in a modified TowerJazz 180 nm CMOS imaging process using a 25 µm epitaxial silicon layer. The readout at 40 MHz is configurable in counting hits in the sensor grouped as either 64 strips or 4 pads. In this article, we present the energy calibration of this sensor using a gamma source of americium-241 as well as X-ray fluorescence at various wavelengths. The uniformity of the pixel responses is shown, allowing the summation of counts across all pixels. By that, two standalone energy calibration methods are developed that describe the X-ray absorption in the energy range of 4–60 keV and agree with each other. The signal pulse height is related to the absorbed photon energy with a 5.54 ± 0.37 mV/keV scale which corresponds to a conversion gain of cg = 19.95 ± 1.32 μV/e−. The relative energy resolution for photon absorption is found to be σE/E = 11.8 ± 3.0%. The absolute counts observed with the DECAL sensor agree with expectations and substantiate the assumption of a fully depleted epitaxial layer. The understanding of the photon absorption is an important input for further development of the sensor towards a multi-layer calorimeter.
- Open Access
DECAL: A Reconfigurable Monolithic Active Pixel Sensor for Tracking and Calorimetry in a 180 nm Image Sensor Process
In this paper, we describe DECAL, a prototype Monolithic Active Pixel Sensor (MAPS) device designed to demonstrate the feasibility of both digital calorimetry and reconfigurability in ASICs for particle physics. The goal of this architecture is to help reduce the development and manufacturing costs of detectors for future colliders by developing a chip that can operate both as a digital silicon calorimeter and a tracking chip. The prototype sensor consists of a matrix of 64 × 64 55 m pixels, and provides a readout at 40 MHz of the number of particles which have struck the matrix in the preceding 25 ns. It can be configured to report this as a total sum across the sensor (equivalent to the pad of an analogue calorimeter) or the sum per column (equivalent to a traditional strip detector). The design and operation of the sensor are described, and the results of chip characterisation are reported and compared to simulations.Open AccessDECAL: A Reconfigurable Monolithic Active Pixel Sensor for Tracking and Calorimetry in a 180 nm Image Sensor Process
In this paper, we describe DECAL, a prototype Monolithic Active Pixel Sensor (MAPS) device designed to demonstrate the feasibility of both digital calorimetry and reconfigurability in ASICs for particle physics. The goal of this architecture is to help reduce the development and manufacturing costs of detectors for future colliders by developing a chip that can operate both as a digital silicon calorimeter and a tracking chip. The prototype sensor consists of a matrix of 64 × 64 55 m pixels, and provides a readout at 40 MHz of the number of particles which have struck the matrix in the preceding 25 ns. It can be configured to report this as a total sum across the sensor (equivalent to the pad of an analogue calorimeter) or the sum per column (equivalent to a traditional strip detector). The design and operation of the sensor are described, and the results of chip characterisation are reported and compared to simulations.