Sara C. Hamon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Sara C. Hamon has a total of 150 co-authors. Here are the top co-authors by number of shared publications:
- Matthew F. Wipperman
Regeneron Pharmaceuticals, Inc. Tarrytown New York USA
7 shared publications - Jennifer D. Hamilton
Regeneron Pharmaceuticals Inc. Tarrytown New York USA
4 shared publications Andreja Avbersek
Early Clinical Development & Experimental Sciences, Regeneron Pharmaceuticals Inc
3 shared publications- Kaitlyn Gayvert
Molecular Profiling & Data Science, Regeneron Pharmaceuticals Inc
3 shared publications - Peter J. Ehmann
Regeneron Pharmaceuticals, Inc., Tarrytown, NY, USA
3 shared publications - Wei Keat Lim
Regeneron Pharmaceuticals, Tarrytown, NY 10591, USA
3 shared publications
Latest Publications
- Open Access
- 19 December 2025
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 8 (1) , 100735
Identification of alkaline phosphatase as a putative biomarker of anti-NGF treatment-associated arthropathies: Machine learning-assisted analyses of clinical trial data
- 19 December 2025
- Published by Elsevier in Osteoarthritis and Cartilage Open
- Vol. 8 (1) , 100735
Open AccessIdentification of alkaline phosphatase as a putative biomarker of anti-NGF treatment-associated arthropathies: Machine learning-assisted analyses of clinical trial data
- Open Access
Divergent T Cell Phenotypes Define Pediatric Crohn’s Disease and Ulcerative Colitis
Pediatric Inflammatory Bowel Disease (IBD) remains challenging to treat and difficult to prognosticate. Although multiple immune cell types coordinate pathology in both Crohn’s disease (CD) and ulcerative colitis (UC), specifying which cell types and cell states portend better or worse response to major IBD treatment strategies, including anti-TNF therapies (the only FDA-approved therapy for pediatric IBD), remains challenging. Here, we present the results of the PREDICT study, which enrolled 79 treatment-naïve pediatric patients at the time of diagnostic endoscopy, enabling a comprehensive transcriptomic, histologic, and serologic analysis of 40 CD patients and 16 UC patients, as well as 23 patients with functional gastrointestinal disorders (FGID) who served as pediatric non-inflamed controls. Leveraging these data, we performed a comprehensive analysis of colonic immunology in each of these clinical conditions. Our results indicate that, within the complex landscape of immune pathology in pediatric CD and UC, there is a coordinated shift across the T H 1-to-T H 17 immune activation continuum among T cells that is pertinent to anti-TNF response. For CD, this shift defines partial response to anti-TNF treatment. For UC, the landscape is more complex, with both T H 17 and TFH biology defining disease, and pre-treatment T H 17 biology contributing to anti-TNF treatment resistance. Related to this, polyreactive TCR phenotypes within UC T FH cells are correlated with both germinal center activity and the frequency of IgG1 plasma cells, yet opposed to the T H 17 signatures associated with anti-TNF nonresponse. The elucidation of these distinct mechanisms of T cell-dependent disease pathology, treatment response, and TCR polyreactivity suggests a model in which sustained T H 17 signaling in CD and baseline T H 17 signaling in UC are associated with disease pathogenesis, forming a basis for a generalized understanding of IBD pathogenesis and underscoring the need for endotype-specific approaches to IBD therapy.
Open AccessDivergent T Cell Phenotypes Define Pediatric Crohn’s Disease and Ulcerative Colitis
Pediatric Inflammatory Bowel Disease (IBD) remains challenging to treat and difficult to prognosticate. Although multiple immune cell types coordinate pathology in both Crohn’s disease (CD) and ulcerative colitis (UC), specifying which cell types and cell states portend better or worse response to major IBD treatment strategies, including anti-TNF therapies (the only FDA-approved therapy for pediatric IBD), remains challenging. Here, we present the results of the PREDICT study, which enrolled 79 treatment-naïve pediatric patients at the time of diagnostic endoscopy, enabling a comprehensive transcriptomic, histologic, and serologic analysis of 40 CD patients and 16 UC patients, as well as 23 patients with functional gastrointestinal disorders (FGID) who served as pediatric non-inflamed controls. Leveraging these data, we performed a comprehensive analysis of colonic immunology in each of these clinical conditions. Our results indicate that, within the complex landscape of immune pathology in pediatric CD and UC, there is a coordinated shift across the T H 1-to-T H 17 immune activation continuum among T cells that is pertinent to anti-TNF response. For CD, this shift defines partial response to anti-TNF treatment. For UC, the landscape is more complex, with both T H 17 and TFH biology defining disease, and pre-treatment T H 17 biology contributing to anti-TNF treatment resistance. Related to this, polyreactive TCR phenotypes within UC T FH cells are correlated with both germinal center activity and the frequency of IgG1 plasma cells, yet opposed to the T H 17 signatures associated with anti-TNF nonresponse. The elucidation of these distinct mechanisms of T cell-dependent disease pathology, treatment response, and TCR polyreactivity suggests a model in which sustained T H 17 signaling in CD and baseline T H 17 signaling in UC are associated with disease pathogenesis, forming a basis for a generalized understanding of IBD pathogenesis and underscoring the need for endotype-specific approaches to IBD therapy.
- Open Access
- 30 April 2024
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 13
Digital wearable insole-based identification of knee arthropathies and gait signatures using machine learning
Gait is impaired in musculoskeletal conditions, such as knee arthropathy. Gait analysis is used in clinical practice to inform diagnosis and monitor disease progression or intervention response. However, clinical gait analysis relies on subjective visual observation of walking as objective gait analysis has not been possible within clinical settings due to the expensive equipment, large-scale facilities, and highly trained staff required. Relatively low-cost wearable digital insoles may offer a solution to these challenges. In this work, we demonstrate how a digital insole measuring osteoarthritis-specific gait signatures yields similar results to the clinical gait-lab standard. To achieve this, we constructed a machine learning model, trained on force plate data collected in participants with knee arthropathy and controls. This model was highly predictive of force plate data from a validation set (area under the receiver operating characteristics curve [auROC] = 0.86; area under the precision-recall curve [auPR] = 0.90) and of a separate, independent digital insole dataset containing control and knee osteoarthritis subjects (auROC = 0.83; auPR = 0.86). After showing that digital insole-derived gait characteristics are comparable to traditional gait measurements, we next showed that a single stride of raw sensor time-series data could be accurately assigned to each subject, highlighting that individuals using digital insoles can be identified by their gait characteristics. This work provides a framework for a promising alternative to traditional clinical gait analysis methods, adds to the growing body of knowledge regarding wearable technology analytical pipelines, and supports clinical development of at-home gait assessments, with the potential to improve the ease, frequency, and depth of patient monitoring.
- 30 April 2024
- Published by eLife Sciences Publications, Ltd in eLife
- Vol. 13
Open AccessDigital wearable insole-based identification of knee arthropathies and gait signatures using machine learning
Gait is impaired in musculoskeletal conditions, such as knee arthropathy. Gait analysis is used in clinical practice to inform diagnosis and monitor disease progression or intervention response. However, clinical gait analysis relies on subjective visual observation of walking as objective gait analysis has not been possible within clinical settings due to the expensive equipment, large-scale facilities, and highly trained staff required. Relatively low-cost wearable digital insoles may offer a solution to these challenges. In this work, we demonstrate how a digital insole measuring osteoarthritis-specific gait signatures yields similar results to the clinical gait-lab standard. To achieve this, we constructed a machine learning model, trained on force plate data collected in participants with knee arthropathy and controls. This model was highly predictive of force plate data from a validation set (area under the receiver operating characteristics curve [auROC] = 0.86; area under the precision-recall curve [auPR] = 0.90) and of a separate, independent digital insole dataset containing control and knee osteoarthritis subjects (auROC = 0.83; auPR = 0.86). After showing that digital insole-derived gait characteristics are comparable to traditional gait measurements, we next showed that a single stride of raw sensor time-series data could be accurately assigned to each subject, highlighting that individuals using digital insoles can be identified by their gait characteristics. This work provides a framework for a promising alternative to traditional clinical gait analysis methods, adds to the growing body of knowledge regarding wearable technology analytical pipelines, and supports clinical development of at-home gait assessments, with the potential to improve the ease, frequency, and depth of patient monitoring.
- Open Access
Differential modulation of allergic rhinitis nasal transcriptome by dupilumab and allergy immunotherapy
Background: Nasal epithelial cells are important regulators of barrier function and immune signaling; however, in allergic rhinitis (AR) these functions can be disrupted by inflammatory mediators. We aimed to better discern AR disease mechanisms using transcriptome data from nasal brushing samples from individuals with and without AR.Methods: Data were drawn from a feasibility study of individuals with and without AR to Timothy grass and from a clinical trial evaluating 16 weeks of treatment with the following: dupilumab, a monoclonal antibody that binds interleukin (IL)‐4Rα and inhibits type 2 inflammation by blocking signaling of both IL‐4/IL‐13; subcutaneous immunotherapy with Timothy grass (SCIT), which inhibits allergic responses through pleiotropic effects; SCIT + dupilumab; or placebo. Using nasal brushing samples from these studies, we defined distinct gene signatures in nasal tissue of AR disease and after nasal allergen challenge (NAC) and assessed how these signatures were modulated by study drug(s).Results: Treatment with dupilumab (normalized enrichment score [NES] = −1.73, p = .002) or SCIT + dupilumab (NES = −2.55, p < .001), but not SCIT alone (NES = +1.16, p = .107), significantly repressed the AR disease signature. Dupilumab (NES = −2.55, p < .001), SCIT (NES = −2.99, p < .001), and SCIT + dupilumab (NES = −3.15, p < .001) all repressed the NAC gene signature.Conclusion: These results demonstrate type 2 inflammation is an important contributor to the pathophysiology of AR disease and that inhibition of the type 2 pathway with dupilumab may normalize nasal tissue gene expression.
Open AccessDifferential modulation of allergic rhinitis nasal transcriptome by dupilumab and allergy immunotherapy
Background: Nasal epithelial cells are important regulators of barrier function and immune signaling; however, in allergic rhinitis (AR) these functions can be disrupted by inflammatory mediators. We aimed to better discern AR disease mechanisms using transcriptome data from nasal brushing samples from individuals with and without AR.Methods: Data were drawn from a feasibility study of individuals with and without AR to Timothy grass and from a clinical trial evaluating 16 weeks of treatment with the following: dupilumab, a monoclonal antibody that binds interleukin (IL)‐4Rα and inhibits type 2 inflammation by blocking signaling of both IL‐4/IL‐13; subcutaneous immunotherapy with Timothy grass (SCIT), which inhibits allergic responses through pleiotropic effects; SCIT + dupilumab; or placebo. Using nasal brushing samples from these studies, we defined distinct gene signatures in nasal tissue of AR disease and after nasal allergen challenge (NAC) and assessed how these signatures were modulated by study drug(s).Results: Treatment with dupilumab (normalized enrichment score [NES] = −1.73, p = .002) or SCIT + dupilumab (NES = −2.55, p < .001), but not SCIT alone (NES = +1.16, p = .107), significantly repressed the AR disease signature. Dupilumab (NES = −2.55, p < .001), SCIT (NES = −2.99, p < .001), and SCIT + dupilumab (NES = −3.15, p < .001) all repressed the NAC gene signature.Conclusion: These results demonstrate type 2 inflammation is an important contributor to the pathophysiology of AR disease and that inhibition of the type 2 pathway with dupilumab may normalize nasal tissue gene expression.
- Open Access
- 7 December 2022
- Published by Elsevier in Microbes and Infection
- Vol. 25 (4) , 105081
Association of complement pathways with COVID-19 severity and outcomes
- 7 December 2022
- Published by Elsevier in Microbes and Infection
- Vol. 25 (4) , 105081
Open AccessAssociation of complement pathways with COVID-19 severity and outcomes
- Open Access
Machine learning analysis of a digital insole versus clinical standard gait assessments for digital endpoint development
Biomechanical gait analysis informs clinical practice and research by linking characteristics of gait with neurological or musculoskeletal injury or disease. However, there are limitations to analyses conducted at gait labs as they require onerous construction of force plates into laboratories mimicking the lived environment, on-site patient assessments, as well as requiring specialist technicians to operate. Digital insoles may offer patient-centric solutions to these challenges. In this work, we demonstrate how a digital insole measuring osteoarthritis-specific gait signatures yields similar results to the clinical gait-lab standard. To achieve this, we constructed a machine learning model, trained on force plate data collected in participants with knee arthropathy and healthy controls. This model was highly predictive of force plate data from a validation set (area under the receiver operating characteristics curve (auROC) = 0.86; area under the precision-recall curve (auPR) = 0.90) and of a separate, independent digital insole dataset containing control and knee osteoarthritis subjects (auROC = 0.83; auPR = 0.86). After showing that digital insole derived gait characteristics are comparable to traditional gait measurements, we next show that a single stride of raw sensor time series data could be accurately assigned to each subject, highlighting that individuals (even healthy) using digital insoles can be identified by their gait characteristics. This work provides a framework for a promising alternative to traditional clinical gait analysis methods, adds to the growing body of knowledge regarding wearable technology analytical pipelines, and supports clinical development of at-home gait assessments, with the potential to improve the ease, frequency, and depth of patient monitoring. One Sentence Summary: Biosensor data collected by digital insoles is comparable to lab-based clinical assessments and can be used to identify subject-specific gait patterns.
Open AccessMachine learning analysis of a digital insole versus clinical standard gait assessments for digital endpoint development
Biomechanical gait analysis informs clinical practice and research by linking characteristics of gait with neurological or musculoskeletal injury or disease. However, there are limitations to analyses conducted at gait labs as they require onerous construction of force plates into laboratories mimicking the lived environment, on-site patient assessments, as well as requiring specialist technicians to operate. Digital insoles may offer patient-centric solutions to these challenges. In this work, we demonstrate how a digital insole measuring osteoarthritis-specific gait signatures yields similar results to the clinical gait-lab standard. To achieve this, we constructed a machine learning model, trained on force plate data collected in participants with knee arthropathy and healthy controls. This model was highly predictive of force plate data from a validation set (area under the receiver operating characteristics curve (auROC) = 0.86; area under the precision-recall curve (auPR) = 0.90) and of a separate, independent digital insole dataset containing control and knee osteoarthritis subjects (auROC = 0.83; auPR = 0.86). After showing that digital insole derived gait characteristics are comparable to traditional gait measurements, we next show that a single stride of raw sensor time series data could be accurately assigned to each subject, highlighting that individuals (even healthy) using digital insoles can be identified by their gait characteristics. This work provides a framework for a promising alternative to traditional clinical gait analysis methods, adds to the growing body of knowledge regarding wearable technology analytical pipelines, and supports clinical development of at-home gait assessments, with the potential to improve the ease, frequency, and depth of patient monitoring. One Sentence Summary: Biosensor data collected by digital insoles is comparable to lab-based clinical assessments and can be used to identify subject-specific gait patterns.
- Open Access
- 30 June 2022
- Published by Public Library of Science (PLoS) in PLOS Digital Health
- Vol. 1 (6) , e0000061
A pilot study of the Earable device to measure facial muscle and eye movement tasks among healthy volunteers
The Earable device is a behind-the-ear wearable originally developed to measure cognitive function. Since Earable measures electroencephalography (EEG), electromyography (EMG), and electrooculography (EOG), it may also have the potential to objectively quantify facial muscle and eye movement activities relevant in the assessment of neuromuscular disorders. As an initial step to developing a digital assessment in neuromuscular disorders, a pilot study was conducted to determine whether the Earable device could be utilized to objectively measure facial muscle and eye movements intended to be representative of Performance Outcome Assessments, (PerfOs) with tasks designed to model clinical PerfOs, referred to as mock-PerfO activities. The specific aims of this study were: To determine whether the Earable raw EMG, EOG, and EEG signals could be processed to extract features describing these waveforms; To determine Earable feature data quality, test re-test reliability, and statistical properties; To determine whether features derived from Earable could be used to determine the difference between various facial muscle and eye movement activities; and, To determine what features and feature types are important for mock-PerfO activity level classification. A total of N = 10 healthy volunteers participated in the study. Each study participant performed 16 mock-PerfOs activities, including talking, chewing, swallowing, eye closure, gazing in different directions, puffing cheeks, chewing an apple, and making various facial expressions. Each activity was repeated four times in the morning and four times at night. A total of 161 summary features were extracted from the EEG, EMG, and EOG bio-sensor data. Feature vectors were used as input to machine learning models to classify the mock-PerfO activities, and model performance was evaluated on a held-out test set. Additionally, a convolutional neural network (CNN) was used to classify low-level representations of the raw bio-sensor data for each task, and model performance was correspondingly evaluated and compared directly to feature classification performance. The model’s prediction accuracy on the Earable device’s classification ability was quantitatively assessed. Study results indicate that Earable can potentially quantify different aspects of facial and eye movements and may be used to differentiate mock-PerfO activities. Specially, Earable was found to differentiate talking, chewing, and swallowing tasks from other tasks with observed F1 scores >0.9. While EMG features contribute to classification accuracy for all tasks, EOG features are important for classifying gaze tasks. Finally, we found that analysis with summary features outperformed a CNN for activity classification. We believe Earable may be used to measure cranial muscle activity relevant for neuromuscular disorder assessment. Classification performance of mock-PerfO activities with summary features enables a strategy for detecting disease-specific signals relative to controls, as well as the monitoring of intra-subject treatment responses. Further testing is needed to evaluate the Earable device in clinical populations and clinical development settings.
- 30 June 2022
- Published by Public Library of Science (PLoS) in PLOS Digital Health
- Vol. 1 (6) , e0000061
Open AccessA pilot study of the Earable device to measure facial muscle and eye movement tasks among healthy volunteers
The Earable device is a behind-the-ear wearable originally developed to measure cognitive function. Since Earable measures electroencephalography (EEG), electromyography (EMG), and electrooculography (EOG), it may also have the potential to objectively quantify facial muscle and eye movement activities relevant in the assessment of neuromuscular disorders. As an initial step to developing a digital assessment in neuromuscular disorders, a pilot study was conducted to determine whether the Earable device could be utilized to objectively measure facial muscle and eye movements intended to be representative of Performance Outcome Assessments, (PerfOs) with tasks designed to model clinical PerfOs, referred to as mock-PerfO activities. The specific aims of this study were: To determine whether the Earable raw EMG, EOG, and EEG signals could be processed to extract features describing these waveforms; To determine Earable feature data quality, test re-test reliability, and statistical properties; To determine whether features derived from Earable could be used to determine the difference between various facial muscle and eye movement activities; and, To determine what features and feature types are important for mock-PerfO activity level classification. A total of N = 10 healthy volunteers participated in the study. Each study participant performed 16 mock-PerfOs activities, including talking, chewing, swallowing, eye closure, gazing in different directions, puffing cheeks, chewing an apple, and making various facial expressions. Each activity was repeated four times in the morning and four times at night. A total of 161 summary features were extracted from the EEG, EMG, and EOG bio-sensor data. Feature vectors were used as input to machine learning models to classify the mock-PerfO activities, and model performance was evaluated on a held-out test set. Additionally, a convolutional neural network (CNN) was used to classify low-level representations of the raw bio-sensor data for each task, and model performance was correspondingly evaluated and compared directly to feature classification performance. The model’s prediction accuracy on the Earable device’s classification ability was quantitatively assessed. Study results indicate that Earable can potentially quantify different aspects of facial and eye movements and may be used to differentiate mock-PerfO activities. Specially, Earable was found to differentiate talking, chewing, and swallowing tasks from other tasks with observed F1 scores >0.9. While EMG features contribute to classification accuracy for all tasks, EOG features are important for classifying gaze tasks. Finally, we found that analysis with summary features outperformed a CNN for activity classification. We believe Earable may be used to measure cranial muscle activity relevant for neuromuscular disorder assessment. Classification performance of mock-PerfO activities with summary features enables a strategy for detecting disease-specific signals relative to controls, as well as the monitoring of intra-subject treatment responses. Further testing is needed to evaluate the Earable device in clinical populations and clinical development settings.
- 1 May 2020
- Published by Elsevier in Gastroenterology
- Vol. 158 (6)
Mo1228 DUPILUMAB NORMALIZES THE EOSINOPHILIC ESOPHAGITIS DISEASE TRANSCRIPTOME IN ADULT PATIENTS WITH EOSINOPHILIC ESOPHAGITIS
- 1 May 2020
- Published by Elsevier in Gastroenterology
- Vol. 158 (6)
Mo1228 DUPILUMAB NORMALIZES THE EOSINOPHILIC ESOPHAGITIS DISEASE TRANSCRIPTOME IN ADULT PATIENTS WITH EOSINOPHILIC ESOPHAGITIS
- Open Access
- 1 September 2016
- Published by Wolters Kluwer Health in Pharmacogenetics and Genomics
- Vol. 26 (9) , 428-435
The α-1 adrenoceptor (ADRA1A) genotype moderates the magnitude of acute cocaine-induced subjective effects in cocaine-dependent individuals
Objectives We examined whether a functional variant of the ADRA1A gene moderated cocaine-induced subjective effects in a group of cocaine-dependent individuals. Methods This study was a within-participant, double-blind, placebo-controlled inpatient human laboratory evaluation of 65 nontreatment-seeking, cocaine-dependent [Diagnostic and Statistical Manual of Mental Disorders, 4th ed. (DSM-IV)] individuals aged 18–55 years. Participants received both placebo (saline, IV) and cocaine (40 mg, IV), and subjective responses were assessed 15 min before receiving an infusion and at 5 min intervals for the subsequent 20 min. The rs1048101 variant of the α1A-adrenoceptor (ADRA1A) gene was genotyped and it was evaluated whether the Cys to Arg substitution at codon 347 in exon 2 (Cys347Arg) moderated the magnitude of the subjective effects produced by cocaine. Results Thirty (46%) participants were found to have the major allele CC genotype and 35 (44%) carried at least one minor T-allele of rs1048101 (TT or TC genotype). Individuals with the CC genotype showed greater responses for ‘desire’ (PPPPPADRA1A genotype could be used to identify individuals for whom acute cocaine exposure may be more rewarding and by inference may result in greater difficulty in establishing and/or maintaining abstinence from cocaine.
- 1 September 2016
- Published by Wolters Kluwer Health in Pharmacogenetics and Genomics
- Vol. 26 (9) , 428-435
Open AccessThe α-1 adrenoceptor (ADRA1A) genotype moderates the magnitude of acute cocaine-induced subjective effects in cocaine-dependent individuals
Objectives We examined whether a functional variant of the ADRA1A gene moderated cocaine-induced subjective effects in a group of cocaine-dependent individuals. Methods This study was a within-participant, double-blind, placebo-controlled inpatient human laboratory evaluation of 65 nontreatment-seeking, cocaine-dependent [Diagnostic and Statistical Manual of Mental Disorders, 4th ed. (DSM-IV)] individuals aged 18–55 years. Participants received both placebo (saline, IV) and cocaine (40 mg, IV), and subjective responses were assessed 15 min before receiving an infusion and at 5 min intervals for the subsequent 20 min. The rs1048101 variant of the α1A-adrenoceptor (ADRA1A) gene was genotyped and it was evaluated whether the Cys to Arg substitution at codon 347 in exon 2 (Cys347Arg) moderated the magnitude of the subjective effects produced by cocaine. Results Thirty (46%) participants were found to have the major allele CC genotype and 35 (44%) carried at least one minor T-allele of rs1048101 (TT or TC genotype). Individuals with the CC genotype showed greater responses for ‘desire’ (PPPPPADRA1A genotype could be used to identify individuals for whom acute cocaine exposure may be more rewarding and by inference may result in greater difficulty in establishing and/or maintaining abstinence from cocaine.
- 11 February 2014
- Published by Springer Nature in Sleep and Breathing
- Vol. 18 (3) , 571-577
Effect of musculoskeletal pain on sleep architecture in patients with obstructive sleep apnea
Obstructive sleep apnea and chronic musculoskeletal pain both affect sleep. Sleep architecture of patients suffering from both is largely unknown. This study seeks to define the sleep architecture of patients with chronic musculoskeletal pain and obstructive sleep apnea. Patients with obstructive sleep apnea diagnosed by sleep study during the past 3 years were included. Patients with clinical documentation of chronic musculoskeletal pain constituted cases, while others were classified as controls. Demographics, clinical factors affecting sleep, medications affecting sleep, Epworth sleepiness scores, and polysomnographic parameters; total sleep time, sleep efficiency, sleep stages, rapid eye movement (REM) sleep onset, apnea–hypopnea index, arousal index, and periodic leg movements were recorded. There were 393 subjects: 200 cases (obstructive sleep apnea and chronic musculoskeletal pain) and 193 controls (obstructive sleep apnea alone). There was significant difference in total sleep time (274.5 ± 62.5 vs. 302.2 ± 60.1 min, p = 0.0001), sleep efficiency (73.54 ± 15.8 vs. 78.76 ± 14.3 %, p = 0.0003), and REM sleep onset (148.18 ± 80.5 vs. 124.8 ± 70.9 min, p = 0.006). Subgroup analysis within the obstructive sleep apnea with chronic musculoskeletal pain group revealed that subjects had better total sleep time and sleep efficiency if they were on REM sleep affecting medications (suppressants and stimulants). Those on REM sleep suppressants slept 25.7 min longer and had 6.4 % more efficient sleep than those not on REM suppressants (p = 0.0034 and p = 0.0037). Patients with obstructive sleep apnea and chronic musculoskeletal pain sleep not only significantly less but also with inferior sleep quality. Their REM sleep is also less in duration and its onset is delayed. Despite low TST and SE, these patients may not exhibit sleepiness.
- 11 February 2014
- Published by Springer Nature in Sleep and Breathing
- Vol. 18 (3) , 571-577
Effect of musculoskeletal pain on sleep architecture in patients with obstructive sleep apnea
Obstructive sleep apnea and chronic musculoskeletal pain both affect sleep. Sleep architecture of patients suffering from both is largely unknown. This study seeks to define the sleep architecture of patients with chronic musculoskeletal pain and obstructive sleep apnea. Patients with obstructive sleep apnea diagnosed by sleep study during the past 3 years were included. Patients with clinical documentation of chronic musculoskeletal pain constituted cases, while others were classified as controls. Demographics, clinical factors affecting sleep, medications affecting sleep, Epworth sleepiness scores, and polysomnographic parameters; total sleep time, sleep efficiency, sleep stages, rapid eye movement (REM) sleep onset, apnea–hypopnea index, arousal index, and periodic leg movements were recorded. There were 393 subjects: 200 cases (obstructive sleep apnea and chronic musculoskeletal pain) and 193 controls (obstructive sleep apnea alone). There was significant difference in total sleep time (274.5 ± 62.5 vs. 302.2 ± 60.1 min, p = 0.0001), sleep efficiency (73.54 ± 15.8 vs. 78.76 ± 14.3 %, p = 0.0003), and REM sleep onset (148.18 ± 80.5 vs. 124.8 ± 70.9 min, p = 0.006). Subgroup analysis within the obstructive sleep apnea with chronic musculoskeletal pain group revealed that subjects had better total sleep time and sleep efficiency if they were on REM sleep affecting medications (suppressants and stimulants). Those on REM sleep suppressants slept 25.7 min longer and had 6.4 % more efficient sleep than those not on REM suppressants (p = 0.0034 and p = 0.0037). Patients with obstructive sleep apnea and chronic musculoskeletal pain sleep not only significantly less but also with inferior sleep quality. Their REM sleep is also less in duration and its onset is delayed. Despite low TST and SE, these patients may not exhibit sleepiness.