Shunsuke Kawatani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Shunsuke Kawatani has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Masaru Kato
Tottori University
3 shared publications - Aiko Takami
Department of Cardiovascular Medicine and Endocrinology and Metabolism, Faculty of Medicine, Tottori University
2 shared publications - Akihiro Okamura
Department of Cardiovascular Medicine and Endocrinology and Metabolism, Faculty of Medicine, Tottori University, Yonago, Japan
2 shared publications - Kazuhiro Yamamoto
National Cerebral and Cardiovascular Center Hospital Suita Japan
2 shared publications Takuya Tomomori
Tottori Daigaku
2 shared publicationsAiko Takami
Tottori Daigaku
1 shared publication
Latest Publications
- Open Access
- 21 March 2023
- Published by Wiley
Characteristics and Incidence of Patients With Tricuspid Valve Prolapse After Micra Transcatheter Pacing System Implantation
Background: The characteristics and incidence of patients with tricuspid valve (TV) prolapse after leadless pacemaker implantation are unknown. Methods and Results: We retrospectively identified 35 of 85 patients with sufficient echocardiographic TV imaging before and after Micra transcatheter pacing system (Micra TPS) implantation. The post-procedure incidence of TV prolapse was 8.6%, and the cause of prolapse was chordae tendineae rupture. Patients with TV prolapse had significantly longer procedure times and more deployments than patients without TV prolapse. Conclusions: TV prolapse after Micra TPS implantation is not a rare complication and is accompanied by frequent deployments and prolonged procedure times.
- 21 March 2023
- Published by Wiley
Open AccessCharacteristics and Incidence of Patients With Tricuspid Valve Prolapse After Micra Transcatheter Pacing System Implantation
Background: The characteristics and incidence of patients with tricuspid valve (TV) prolapse after leadless pacemaker implantation are unknown. Methods and Results: We retrospectively identified 35 of 85 patients with sufficient echocardiographic TV imaging before and after Micra transcatheter pacing system (Micra TPS) implantation. The post-procedure incidence of TV prolapse was 8.6%, and the cause of prolapse was chordae tendineae rupture. Patients with TV prolapse had significantly longer procedure times and more deployments than patients without TV prolapse. Conclusions: TV prolapse after Micra TPS implantation is not a rare complication and is accompanied by frequent deployments and prolonged procedure times.
- Open Access
- 30 June 2022
- Published by Radcliffe Medical Media Ltd in Journal of Asian Pacific Society of Cardiology
- Vol. 1
Impact of BMI and Type of Ablation Procedure on Atrial Fibrillation Recurrence in Japanese Patients
Background: AF recurs more frequently after catheter ablation in individuals with a high BMI than it does in those with a normal BMI. However, the association between AF recurrence and BMI may be influenced by race. The authors investigated the relationship between BMI and AF recurrence after catheter ablation in Japanese patients. Methods: They enrolled 726 consecutive patients with paroxysmal or persistent AF (241 patients classified as overweight/obese [BMI ≥25 kg/m2] and 485 classified as non-overweight/obese [BMI <25 kg/m2]) who underwent cryoablation or radiofrequency ablation. The relationship between BMI and AF recurrence was assessed. Results: AF recurred in 183 patients (25.2%; 105 with paroxysmal AF and 78 with persistent AF). Median BMI differed significantly between patients with and without AF recurrence (23.9 kg/m2 [interquartile range: 21.6–26.9] versus 23.2 kg/m2 [interquartile range: 21.3–25.4]; p=0.011). Fisher’s exact test showed that the AF recurrence rate increased significantly with BMI in the radiofrequency ablation group (non-overweight/obese: 23.9% versus overweight/obese: 44.6%; p<0.001) but not in the cryoablation group (non-overweight/obese: 19.3% versus overweight/obese: 18.0%; p=0.883). Patients classified as overweight/obese had a significantly larger left atrial dimension, and left atrial dimension increased synergistically with persistent AF and increasing BMI. Conclusion: The AF recurrence rate in Japanese patients who underwent radiofrequency ablation, but not in those who underwent cryoablation, increased with BMI (especially BMI ≥25 kg/m2). Cryoablation may be superior to radiofrequency ablation in Japanese patients classified as overweight/obese.
- 30 June 2022
- Published by Radcliffe Medical Media Ltd in Journal of Asian Pacific Society of Cardiology
- Vol. 1
Open AccessImpact of BMI and Type of Ablation Procedure on Atrial Fibrillation Recurrence in Japanese Patients
Background: AF recurs more frequently after catheter ablation in individuals with a high BMI than it does in those with a normal BMI. However, the association between AF recurrence and BMI may be influenced by race. The authors investigated the relationship between BMI and AF recurrence after catheter ablation in Japanese patients. Methods: They enrolled 726 consecutive patients with paroxysmal or persistent AF (241 patients classified as overweight/obese [BMI ≥25 kg/m2] and 485 classified as non-overweight/obese [BMI <25 kg/m2]) who underwent cryoablation or radiofrequency ablation. The relationship between BMI and AF recurrence was assessed. Results: AF recurred in 183 patients (25.2%; 105 with paroxysmal AF and 78 with persistent AF). Median BMI differed significantly between patients with and without AF recurrence (23.9 kg/m2 [interquartile range: 21.6–26.9] versus 23.2 kg/m2 [interquartile range: 21.3–25.4]; p=0.011). Fisher’s exact test showed that the AF recurrence rate increased significantly with BMI in the radiofrequency ablation group (non-overweight/obese: 23.9% versus overweight/obese: 44.6%; p<0.001) but not in the cryoablation group (non-overweight/obese: 19.3% versus overweight/obese: 18.0%; p=0.883). Patients classified as overweight/obese had a significantly larger left atrial dimension, and left atrial dimension increased synergistically with persistent AF and increasing BMI. Conclusion: The AF recurrence rate in Japanese patients who underwent radiofrequency ablation, but not in those who underwent cryoablation, increased with BMI (especially BMI ≥25 kg/m2). Cryoablation may be superior to radiofrequency ablation in Japanese patients classified as overweight/obese.
- Open Access
- 29 March 2022
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 86 (9) , CJ-22-0071-1480
Successful Chemotherapy With Early Leadless Pacemaker Implantation for a Giant Malignant Lymphoma Complicated by Unstable Atrioventricular Block and Superior Vena Cava Syndrome
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 29 March 2022
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 86 (9) , CJ-22-0071-1480
Open AccessSuccessful Chemotherapy With Early Leadless Pacemaker Implantation for a Giant Malignant Lymphoma Complicated by Unstable Atrioventricular Block and Superior Vena Cava Syndrome
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.