Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


George Z. Tsogas has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Development of a Flatbed Scanner-Based Colorimetric Method for the Indirect Determination of Fluoride Ions Using 96-Well Plates in Oral Hygiene Products

    by Chrysanthi Galenteridi, Maria Tarara, Paraskevas D. Tzanavaras, George Z. Tsogas

    An indirect, novel, fast, and facile assay was developed for the colorimetric determination of fluoride anions using 96-well plates. The proposed method relies on the colorimetric degradation caused by fluoride ions after their reaction with the iron–thiocyanate complex in an acidic medium. The procedure required the addition of minimal amounts of ferric iron and thiocyanate anion solutions to form the corresponding complex with an intense blood-red color, after which, upon addition of fluoride ions, this complex would dissociate, and its color would gradually fade depending on the analyte concentration. The colorimetric differences were measured using a simple imaging device such as a flatbed scanner. Various parameters affecting the analytical performance of the proposed method were optimized, including solution concentrations, pH values, and reaction time for Fe(III)-SCN complex formation and its disintegration process. The proposed assay was successfully applied to the determination of F− in oral hygiene product samples. The method exhibited acceptable detection limits (3.2 mg L−1) with sufficient precision, good intra-day and inter-day reproducibility (ranging from 1.5 to 5.2%), and high selectivity against other anions and components of the samples under study.


  • Open Access

    Development of a 96-Well Plate Dithiothreitol Method for the Colorimetric Determination of Nickel Ions in Water Samples

    by George N. Nikas, Maria Tarara, George Z. Tsogas

    A new, simple, and accurate assay was developed for the colorimetric determination of nickel ions in 96-well plates. The proposed method utilized the color change immediately visible even to the naked eye during the reaction of Ni(II) ions with dithiothreitol molecules (DTT). The intensity of the color produced by the formation of the complex between nickel and dithiothreitol is linearly proportional to the concentration of the metal ions in an alkaline environment, at room temperature, and the detection was performed using a mobile phone as the detector. The proposed method had a good linear response between 0.05 and 0.75 mmol L−1 and a detection limit of 0.13 mmol L−1 and was successfully applied for the determination of Ni(II) in bottled and surface water samples.

  • Open Access

    O-Phthalaldehyde Derivatization for the Paper-Based Fluorometric Determination of Glutathione in Nutritional Supplements

    by Maria Tarara, Paraskevas D. Tzanavaras, George Z. Tsogas

    Herein, a new, direct paper-based fluorimetric method is described for the quantitative determination of glutathione (GSH) molecules in nutritional supplements. Briefly, the proposed analytical method is based on the fluorescence emission resulting from the direct and selective chemical reaction of GSH molecules with the derivatization reagent that is o-phthalaldehyde (OPA) in acidic conditions at room temperature. The intensity of the emitted fluorescence on the surface of the analytical paper devices after irradiation with a lamp at 365 nm is proportional to the concentration of GSH and is measured using a smartphone as the detector. This methodology, which is suitable for measurements in laboratories with limited resources, does not require specialized instrumentation or trained personnel. The protocol governing the proposed method is simple and easily applicable. Essentially, the chemical analyst should adjust the value of pH on the surface of the paper by adding a minimal amount of buffer solution; then, after adding a few microliters of the derivatization reagent, wait for the surface of the paper to dry and, finally, add the analyte. Subsequently, the irradiation of the sensor and the measurement of the emitted fluorescence can be recorded with a mobile phone. In the present study, several parameters affecting the chemical reaction and the emitted fluorescence were optimized, the effect of interfering compounds that may be present in dietary supplements was examined, and the stability of these paper sensors under different storage conditions was evaluated. Additionally, the chemical stability of these paper devices in various maintenance conditions was studied, with satisfactory results. The detection limit calculated as 3.3 S/N was 20.5 μmol L−1, while the precision of the method was satisfactory, ranging from 3.1% (intra-day) to 7.3% (inter-day). Finally, the method was successfully applied to three different samples of dietary supplements.


  • Open Access

    Smartphone-Based High-Throughput Fluorimetric Assay for Histidine Quantification in Human Urine Using 96-Well Plates

    by Dimitrios Baltzis, George Z. Tsogas, Constantinos K. Zacharis, Paraskevas D. Tzanavaras

    A high-throughput fluorimetric assay for histidine was developed, using a 96-well plates platform. The analyte reacts selectively with o-phthalaldehyde under mild alkaline conditions to form a stable derivative. Instrumental-free detection was carried out using a smartphone after illumination under UV light (365 nm). The method was proved to be linear up to 100 μM histidine, with an LLOQ (lower limit of quantification) of 10 μM. The assay was only prone to interference from glutathione and histamine that exist in the urine samples at levels that are orders of magnitude lower compared to histidine. Human urine samples were analyzed following minimum treatment and were found to contain histidine in the range of 280 to 1540 μM. The results were in good agreement with an HPLC corroborative method.


  • Open Access

    A Low-Cost Colorimetric Assay for the Analytical Determination of Copper Ions with Consumer Electronic Imaging Devices in Natural Water Samples

    by Argyro G. Gkouliamtzi, Vasiliki C. Tsaftari, Maria Tarara, George Z. Tsogas

    This study reports a new approach for the determination of copper ions in water samples that exploits the complexation reaction with diethyldithiocarbamate (DDTC) and uses widely available imaging devices (i.e., flatbed scanners or smartphones) as detectors. Specifically, the proposed approach is based on the ability of DDTC to bind to copper ions and form a stable Cu-DDTC complex with a distinctive yellow color detected with the camera of a smartphone in a 96-well plate. The color intensity of the formed complex is linearly proportional to the concentration of copper ions, resulting in its accurate colorimetric determination. The proposed analytical procedure for the determination of Cu2+ was easy to perform, rapid, and applicable with inexpensive and commercially available materials and reagents. Many parameters related to such an analytical determination were optimized, and a study of interfering ions present in the water samples was also carried out. Additionally, even low copper levels could be noticed by the naked eye. The assay performed was successfully applied to the determination of Cu2+ in river, tap, and bottled water samples with detection limits as low as 1.4 µM, good recoveries (89.0–109.6%), adequate reproducibility (0.6–6.1%), and high selectivity over other ions present in the water samples.


  • Open Access

    A Novel Equipment-Free Paper-Based Fluorometric Method for the Analytical Determination of Quinine in Soft Drink Samples

    by Vasiliki C. Tsaftari, Maria Tarara, Paraskevas D. Tzanavaras, George Z. Tsogas

    A simple, equipment-free, direct fluorometric method, employing paper-based analytical devices (PADs) as sensors, for the selective determination of quinine (QN) is described herein. The suggested analytical method exploits the fluorescence emission of QN without any chemical reaction after the appropriate pH adjustment with nitric acid, at room temperature, on the surface of a paper device with the application of a UV lamp at 365 nm. The devices crafted had a low cost and were manufactured with chromatographic paper and wax barriers, and the analytical protocol followed was extremely easy for the analyst and required no laboratory instrumentation. According to the methodology, the user must place the sample on the detection area of the paper and read with a smartphone the fluorescence emitted by the QN molecules. Many chemical parameters were optimized, and a study of interfering ions present in soft drink samples was carried out. Additionally, the chemical stability of these paper devices was considered in various maintenance conditions with good results. The detection limit calculated as 3.3 S/N was 3.6 mg L−1, and the precision of the method was satisfactory, being from 3.1% (intra-day) to 8.8% (inter-day). Soft drink samples were successfully analyzed and compared with a fluorescence method.


  • Open Access

    Development of a Paper-Based Analytical Method for the Colorimetric Determination of Calcium in Saliva Samples

    by Maria Tarara, Paraskevas D. Tzanavaras, George Z. Tsogas

    A novel, rapid, and facile method for the colorimetric determination of calcium using micro-analytical paper-based devices (μ-PADs) was developed. The proposed analytical method utilizes the color differences developing, after the addition of calcium, on the surface of the devices because of the complexation reaction of calcium with Methylthymol Blue (MTB) at room temperature, in alkaline pH. The devices were manufactured with chromatographic paper, using wax barriers, and the analytical protocol was easily implemented without the need of any experimental apparatus except for a simple imaging device. The user must regulate the pH, add the solutions on the paper, and measure the color intensity of the formed Ca(II)–MTB complex with a flatbed scanner. The experimental conditions for optimum color development, the possible interfering substances, and the reliability of the paper devices in different preserving conditions were optimized, with satisfactory results. The method exhibited acceptable detection limits (2.9 mg L−1) with sufficiently good precision, which varied from 4.2% (intra-day) to 6.4% (inter-day). Saliva samples from healthy volunteers were successfully analyzed, and the calcium levels were calculated in the range of 30.71 to 84.15 mg L−1.


  • Open Access

    Development of a Paper-Based Analytical Method for the Selective Colorimetric Determination of Bismuth in Water Samples

    by Panagiotis A. Bizirtsakis, Maria Tarara, Apostolia Tsiasioti, Paraskevas D. Tzanavaras, George Z. Tsogas

    A novel, direct and simple colorimetric method employing μicroanalytical paper-based devices (μ-PADs) for the selective determination of bismuth is described. The suggested method exploits the colorimetric variation of bismuth after its rapid reaction with methyl thymol blue (MTB) in an acidic medium (pH ranging between 0.7 and 3.0), modified with nitric acid, on the surface of a paper device at room temperature. The devices are low cost, composed of chromatographic paper and wax barriers and the analytical protocol is easily applicable with minimal technical expertise and without the need for experimental apparatus. The user must add a test sample and read the color intensity of the colored Bi(III)–MTB complex formed at the sensing area using a simple imaging device such as a flatbed scanner. Various chemical variables, such as HNO3 and MTB concentration, reaction time, ionic strength, detection zone size and photo-capture detector are optimized. A study of interfering ions such as K+, Na+, Ca2+, Mg2+, Cl−, SO42− and HCO3− was also conducted. The stability of the paper devices is also studied in different maintenance conditions with particularly satisfactory results, rendering the method suitable for field analysis. The detection limits are as low as 3.0 mg L−1 with very satisfactory precision, ranging from 4.0% (intra-day) to 5.5% (inter-day). Natural water samples are successfully analyzed, and bismuth percentage recoveries were calculated in the range of 82.8 to 115.4%.