Taha Tuna Göksu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Taha Tuna Göksu has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
- Ahmet Yakın
Van Yuzuncu Yil Universitesi
2 shared publications - Fuat Yilmaz
Department of Mechanical Engineering, Gaziantep University, Gaziantep, Turkey
1 shared publication Hakan F. Öztop
1 shared publicationMehmet Gülcan
1 shared publication- Mehmet Gülcan
Department of Chemistry, Van Yüzüncü Yıl University, Van, 65080, Turkey
1 shared publication Rasim Behçet
1 shared publication
Latest Publications
- 11 February 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 217
Exergy and sustainability analysis of methylamine borane-enhanced gasoline fuel blends
- 11 February 2026
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 217
Exergy and sustainability analysis of methylamine borane-enhanced gasoline fuel blends
- Open Access
- 20 June 2024
- Published by European Mechanical Science in European Mechanical Science
- Vol. 8 (2) , 71-77
An analysis of the impact of nanofluids on the cooling effectiveness of pin and perforated heat sinks
In the presented numerical study, the effect of the use of mono and hybrid (CuO/Water at 2% volume concentration and CuO + Fe/Water (1% CuO + 1% Fe)) type nanofluid in heat sinks designed in new geometric structures used to increase the processor cooling performance was investigated. The geometries used are circular, triangular, square, hexagonal, square, and hexagonal, and their perforated structures and their effects on a total of eight geometries were analyzed. In addition to these, the rate of improving the temperature distribution and heat transfer in the heat sink, i.e., the Performance Evaluation Criterion (PEC), was also examined. According to the results obtained, the lowest thermal resistance value is seen in the circular cross-section with Rth = 0.289 K/W, while the highest thermal, i.e., cooling performance is seen in the triangular perforated structure with Rth = 0.63 K/W and at the lowest pressure inlet condition. In terms of temperature distribution, the most uniform distribution was obtained between 311.82 and 308.98 K in the circular section. The most interesting result in terms of the results was the PEC = 1.4 for the triangular hole structure in the heat transfer improvement performance. The main reason for this is that the range of the temperature distribution shown is very high (319–311.5K).
- 20 June 2024
- Published by European Mechanical Science in European Mechanical Science
- Vol. 8 (2) , 71-77
Open AccessAn analysis of the impact of nanofluids on the cooling effectiveness of pin and perforated heat sinks
In the presented numerical study, the effect of the use of mono and hybrid (CuO/Water at 2% volume concentration and CuO + Fe/Water (1% CuO + 1% Fe)) type nanofluid in heat sinks designed in new geometric structures used to increase the processor cooling performance was investigated. The geometries used are circular, triangular, square, hexagonal, square, and hexagonal, and their perforated structures and their effects on a total of eight geometries were analyzed. In addition to these, the rate of improving the temperature distribution and heat transfer in the heat sink, i.e., the Performance Evaluation Criterion (PEC), was also examined. According to the results obtained, the lowest thermal resistance value is seen in the circular cross-section with Rth = 0.289 K/W, while the highest thermal, i.e., cooling performance is seen in the triangular perforated structure with Rth = 0.63 K/W and at the lowest pressure inlet condition. In terms of temperature distribution, the most uniform distribution was obtained between 311.82 and 308.98 K in the circular section. The most interesting result in terms of the results was the PEC = 1.4 for the triangular hole structure in the heat transfer improvement performance. The main reason for this is that the range of the temperature distribution shown is very high (319–311.5K).
Energy, exergy analysis, and RSM modeling of different designed twisted tapes in placed PV/T systems
- Open Access
- 12 June 2024
- Published by Fırat University, Faculty of Engineering in Firat University Journal of Experimental and Computational Engineering
- Vol. 3 (2) , 185-203
Investigation of The Effect of Geometrical Parameters And Fluid Properties of Heat Sinks on Cooling By RSM Method
This study investigated the effect of the response surface method (RSM) on heat sinks designed in block types and using various fluids. The RSM method was applied to the data obtained from heat sinks designed in block type placed in both vertical and horizontal directions using water, mono, nanofluids, and hybrid nanofluids. The data were collected under five different pressure boundary conditions and applied to 144 data sets. The Box-Behnken method was used to analyze the design parameters and derive equations for seven different parameters: density, viscosity, specific heat, thermal conductivity, block thickness, block distances, and inlet pressure boundary conditions. The equations were used to determine the average CPU temperature, thermal resistance, and Performance Evaluation Criteria (PEC). The findings show that the R2 values for thermal resistance (Rth), average CPU temperature (Tm), and performance evaluation criteria (PEC) for flat arrangements are 99.21%, 99.21%, and 99.37%, respectively. The R2 values for the vertically designed geometries are 97.66%, 97.66%, and 98.45%, indicating a strong correlation between the results obtained from FLUENT and the ANOVA statistical results. The linear, square, and cubic effects of each variable had a significant impact on each solution. The study concluded that the RSM method has a significant effect on heat sinks with higher R2 values in horizontal arrangements and a higher distance between blocks. Another important result showed that increasing the block thickness also has a significant effect on Rth and Tm, homogenizing the temperature distribution while increasing the cooling capacity.
- 12 June 2024
- Published by Fırat University, Faculty of Engineering in Firat University Journal of Experimental and Computational Engineering
- Vol. 3 (2) , 185-203
Open AccessInvestigation of The Effect of Geometrical Parameters And Fluid Properties of Heat Sinks on Cooling By RSM Method
This study investigated the effect of the response surface method (RSM) on heat sinks designed in block types and using various fluids. The RSM method was applied to the data obtained from heat sinks designed in block type placed in both vertical and horizontal directions using water, mono, nanofluids, and hybrid nanofluids. The data were collected under five different pressure boundary conditions and applied to 144 data sets. The Box-Behnken method was used to analyze the design parameters and derive equations for seven different parameters: density, viscosity, specific heat, thermal conductivity, block thickness, block distances, and inlet pressure boundary conditions. The equations were used to determine the average CPU temperature, thermal resistance, and Performance Evaluation Criteria (PEC). The findings show that the R2 values for thermal resistance (Rth), average CPU temperature (Tm), and performance evaluation criteria (PEC) for flat arrangements are 99.21%, 99.21%, and 99.37%, respectively. The R2 values for the vertically designed geometries are 97.66%, 97.66%, and 98.45%, indicating a strong correlation between the results obtained from FLUENT and the ANOVA statistical results. The linear, square, and cubic effects of each variable had a significant impact on each solution. The study concluded that the RSM method has a significant effect on heat sinks with higher R2 values in horizontal arrangements and a higher distance between blocks. Another important result showed that increasing the block thickness also has a significant effect on Rth and Tm, homogenizing the temperature distribution while increasing the cooling capacity.
- Open Access
- 8 April 2024
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 149 (12) , 6517-6529
Investigation of pin and perforated heatsink cooling efficiency and temperature distribution
The uneven temperature distribution resulting from thermal stresses in heat sinks is a significant issue in modern electronic devices. This numerical investigation utilizes fluid to analyze the cooling, flow, and heat transfer characteristics of eight different heat sink designs. These include pin–fin heat sinks with circular, triangular, square, and hexagonal cross-sections, as well as their perforated versions. The results show that the thermal resistance range for all geometries was between Rth = 0.29 and 0.51 K W−1. The circular cross-section pin structure was found to be the most efficient in terms of thermal resistance, while the triangular perforated structure was the least efficient. The narrow and low temperature distribution indicates a high cooling potential for the heat sink. It has been observed that the temperature range studied is between 308.732 and 315.273 K. The circular cross-section pin structure is most efficient in terms of homogeneous distribution between 308.73 and 311.306 K. The pin-type structure with a square cross-section attained the maximum Performance Evaluation Criteria (PEC) of 1.1872 at P = 689 Pa, while the pin-type structure with a triangular cross-section attained the lowest PEC of 0.67 at P = 2750 Pa. The investigation revealed that, in relation to PEC, perforated structures had superior performance compared to other pin designs, except for the square-section pin structure. This research found that measuring the efficiency of a heat sink based just on thermal resistance or average temperature distribution is not enough; the PEC criteria must also be taken into account.
- 8 April 2024
- Published by Springer Nature in Journal of Thermal Analysis and Calorimetry
- Vol. 149 (12) , 6517-6529
Open AccessInvestigation of pin and perforated heatsink cooling efficiency and temperature distribution
The uneven temperature distribution resulting from thermal stresses in heat sinks is a significant issue in modern electronic devices. This numerical investigation utilizes fluid to analyze the cooling, flow, and heat transfer characteristics of eight different heat sink designs. These include pin–fin heat sinks with circular, triangular, square, and hexagonal cross-sections, as well as their perforated versions. The results show that the thermal resistance range for all geometries was between Rth = 0.29 and 0.51 K W−1. The circular cross-section pin structure was found to be the most efficient in terms of thermal resistance, while the triangular perforated structure was the least efficient. The narrow and low temperature distribution indicates a high cooling potential for the heat sink. It has been observed that the temperature range studied is between 308.732 and 315.273 K. The circular cross-section pin structure is most efficient in terms of homogeneous distribution between 308.73 and 311.306 K. The pin-type structure with a square cross-section attained the maximum Performance Evaluation Criteria (PEC) of 1.1872 at P = 689 Pa, while the pin-type structure with a triangular cross-section attained the lowest PEC of 0.67 at P = 2750 Pa. The investigation revealed that, in relation to PEC, perforated structures had superior performance compared to other pin designs, except for the square-section pin structure. This research found that measuring the efficiency of a heat sink based just on thermal resistance or average temperature distribution is not enough; the PEC criteria must also be taken into account.
- Open Access
- 5 February 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 55
Enhancing cooling efficiency: Innovative geometric designs and mono-hybrid nanofluid applications in heat sinks
- 5 February 2024
- Published by Elsevier in Case Studies in Thermal Engineering
- Vol. 55
Open AccessEnhancing cooling efficiency: Innovative geometric designs and mono-hybrid nanofluid applications in heat sinks
- 18 November 2021
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 7 (7) , 1683-1693
Numerical comparison study on heat transfer enhancement of different cross-section wire coils insert with varying pitches in a duct
Heat transfer enhancement (HTE) efforts spent during the last half-century have become one of the most important working areas of researchers from both academia and industry. One of the most popular passive methods, with regard to the price-performance ratio, is to place wire coils in a pipe or duct. In this study, the heat and pressure drop characteristics of diamond, triangular, and circular cross-sectional wire coils (DWC, TWC, and CWC) in a square duct were investigated by using the FLUENT program. In addition to the cross-section examination, the thermo-hydraulic behavior of three different pitches (p = 54, 72, and 90 mm) for the specified geometries were also investigated. The Reynolds number was between 4387 and 18,415. The square duct was 1.25 m in length, and was 18 mm in diameter. The results showed that the Nusselt number of CWC, TWC, and DWC were higher than that of a smooth pipe within 38–88%, 37–93%, and 38–98% range, respectively. The friction of CWC, TWC, and DWC was observed to be higher than that of a plain tube within a range of 87–278%, 82–266%, and 107–366%, respectively. The TWC with 90 mm pitch showed the highest heat transfer performance evaluation criteria (PEC) with a performance coefficient of 1.3 at Reynolds number of 4504, whereas the DWC with 54 mm pitch was observed to show the lowest PEC. Thus, the as-obtained PEC, which is 30% higher than that of a plain tube, indicates the prominence and effectiveness of the numerical study in increasing the heat transfer.
- 18 November 2021
- Published by Yildiz Technical University in Journal of Thermal Engineering
- Vol. 7 (7) , 1683-1693
Numerical comparison study on heat transfer enhancement of different cross-section wire coils insert with varying pitches in a duct
Heat transfer enhancement (HTE) efforts spent during the last half-century have become one of the most important working areas of researchers from both academia and industry. One of the most popular passive methods, with regard to the price-performance ratio, is to place wire coils in a pipe or duct. In this study, the heat and pressure drop characteristics of diamond, triangular, and circular cross-sectional wire coils (DWC, TWC, and CWC) in a square duct were investigated by using the FLUENT program. In addition to the cross-section examination, the thermo-hydraulic behavior of three different pitches (p = 54, 72, and 90 mm) for the specified geometries were also investigated. The Reynolds number was between 4387 and 18,415. The square duct was 1.25 m in length, and was 18 mm in diameter. The results showed that the Nusselt number of CWC, TWC, and DWC were higher than that of a smooth pipe within 38–88%, 37–93%, and 38–98% range, respectively. The friction of CWC, TWC, and DWC was observed to be higher than that of a plain tube within a range of 87–278%, 82–266%, and 107–366%, respectively. The TWC with 90 mm pitch showed the highest heat transfer performance evaluation criteria (PEC) with a performance coefficient of 1.3 at Reynolds number of 4504, whereas the DWC with 54 mm pitch was observed to show the lowest PEC. Thus, the as-obtained PEC, which is 30% higher than that of a plain tube, indicates the prominence and effectiveness of the numerical study in increasing the heat transfer.