Angela T. Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Angela T. Li has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Anu Patel
University of California San Francisco Department of Bioengineering and Therapeutic Sciences San Francisco, CA
2 shared publications - Belen Perez Solans
University of California San Francisco Department of Bioengineering and Therapeutic Sciences San Francisco, CA
2 shared publications - Radojka M. Savic
Department of Bioengineering and Therapeutic Sciences, University of California San Francisco, San Francisco, California, USA
2 shared publications - Nadav Shapira
University of Pennsylvania
1 shared publication - Peter Benjamin Noël
Department of Radiology Perelman School of Medicine University of Pennsylvania Philadelphia Pennsylvania USA
1 shared publication
Latest Publications
- Open Access
Establishing a framework for human dose prediction in anti-tuberculosis drug development
Rationale: Efficacious dose selection for anti-tuberculosis drugs has traditionally relied on achieving plasma exposures above the minimum inhibitory concentration, but this approach has not consistently aligned with clinical outcomes. Objectives: We sought to identify early pharmacokinetic-pharmacodynamic targets most predictive of clinical efficacious dose. Methods: We conducted a back-translational, pharmacokinetic-pharmacodynamic simulation-based analysis of 15 anti-tuberculosis drugs. Using pharmacokinetic data from multiple biological matrices and a range of pharmacodynamic metrics, we established candidate exposure-response targets for attainment. We systematically evaluated the predictive accuracy of each target pair against established clinical doses to formulate a decision-making framework linking key drug properties to the most predictive targets. Measurements and Main Results: Depending on the target used, projected clinical doses varied widely—both within and across compounds—highlighting the importance of target selection for dose projection and go/no-go decisions. In general, targeting cellular lesion-level drug exposures relative to in vivo preclinical potency provided an effective approach for early dose selection. However, for highly penetrating drugs, targeting site-of-action therapeutic exposures in the caseum was more predictive of clinical dose. Based on these findings, we developed a preliminary dose prediction tool that enables drug developers to estimate clinically relevant dose ranges of compounds using in vitro and early in vivo data. Conclusions: This work establishes and validates a simple, evidence-based framework to standardize early translational decision-making on dose selection of anti-tuberculosis candidates in development.
Open AccessEstablishing a framework for human dose prediction in anti-tuberculosis drug development
Rationale: Efficacious dose selection for anti-tuberculosis drugs has traditionally relied on achieving plasma exposures above the minimum inhibitory concentration, but this approach has not consistently aligned with clinical outcomes. Objectives: We sought to identify early pharmacokinetic-pharmacodynamic targets most predictive of clinical efficacious dose. Methods: We conducted a back-translational, pharmacokinetic-pharmacodynamic simulation-based analysis of 15 anti-tuberculosis drugs. Using pharmacokinetic data from multiple biological matrices and a range of pharmacodynamic metrics, we established candidate exposure-response targets for attainment. We systematically evaluated the predictive accuracy of each target pair against established clinical doses to formulate a decision-making framework linking key drug properties to the most predictive targets. Measurements and Main Results: Depending on the target used, projected clinical doses varied widely—both within and across compounds—highlighting the importance of target selection for dose projection and go/no-go decisions. In general, targeting cellular lesion-level drug exposures relative to in vivo preclinical potency provided an effective approach for early dose selection. However, for highly penetrating drugs, targeting site-of-action therapeutic exposures in the caseum was more predictive of clinical dose. Based on these findings, we developed a preliminary dose prediction tool that enables drug developers to estimate clinically relevant dose ranges of compounds using in vitro and early in vivo data. Conclusions: This work establishes and validates a simple, evidence-based framework to standardize early translational decision-making on dose selection of anti-tuberculosis candidates in development.
- Open Access
Automatic Bolus Tracking in Abdominal CT scans with Convolutional Neural Networks
Background Bolus tracking can optimize the time delay between contrast injection and diagnostic scan initiation in contrast-enhanced computed tomography (CT), yet the procedure is time-consuming and subject to inter- and intra-operator variances which affect the enhancement levels in diagnostic scans. The objective of the current study is to use artificial intelligence algorithms to fully automate the bolus tracking procedure in contrast-enhanced abdominal CT exams for improved standardization and diagnostic accuracy while providing a simplified imaging workflow. Methods This retrospective study used abdominal CT exams collected under a dedicated IRB. Input data consisted of CT topograms and images with high heterogeneity in terms of anatomy, sex, cancer pathologies, and imaging artifacts acquired with four different CT scanner models. Our method consisted of two sequential steps: (i) automatic locator scan positioning on topograms, and (ii) automatic ROI positioning within the aorta on locator scans. The task of locator scan positioning is formulated as a regression problem, where the limited amount of annotated data is circumvented using transfer learning. The task of ROI positioning is formulated as a segmentation problem. Results Our locator scan positioning network offered improved positional consistency compared to a high degree of variance in manual slice positionings, verifying inter-operator variance as a significant source of error. When trained using expert-user ground truth labels, the locator scan positioning network achieved a sub-centimeter error (9.76 ± 6.78 mm) on a test dataset. The ROI segmentation network achieved a sub-millimeter absolute error (0.99 ± 0.66 mm) on a test dataset. Conclusions Locator scan positioning networks offer improved positional consistency compared to manual slice positionings and verified inter-operator variance as an important source of error. By significantly reducing operator-related decisions, this method opens opportunities to standardize and simplify the workflow of bolus tracking procedures for contrast-enhanced CT.
Open AccessAutomatic Bolus Tracking in Abdominal CT scans with Convolutional Neural Networks
Background Bolus tracking can optimize the time delay between contrast injection and diagnostic scan initiation in contrast-enhanced computed tomography (CT), yet the procedure is time-consuming and subject to inter- and intra-operator variances which affect the enhancement levels in diagnostic scans. The objective of the current study is to use artificial intelligence algorithms to fully automate the bolus tracking procedure in contrast-enhanced abdominal CT exams for improved standardization and diagnostic accuracy while providing a simplified imaging workflow. Methods This retrospective study used abdominal CT exams collected under a dedicated IRB. Input data consisted of CT topograms and images with high heterogeneity in terms of anatomy, sex, cancer pathologies, and imaging artifacts acquired with four different CT scanner models. Our method consisted of two sequential steps: (i) automatic locator scan positioning on topograms, and (ii) automatic ROI positioning within the aorta on locator scans. The task of locator scan positioning is formulated as a regression problem, where the limited amount of annotated data is circumvented using transfer learning. The task of ROI positioning is formulated as a segmentation problem. Results Our locator scan positioning network offered improved positional consistency compared to a high degree of variance in manual slice positionings, verifying inter-operator variance as a significant source of error. When trained using expert-user ground truth labels, the locator scan positioning network achieved a sub-centimeter error (9.76 ± 6.78 mm) on a test dataset. The ROI segmentation network achieved a sub-millimeter absolute error (0.99 ± 0.66 mm) on a test dataset. Conclusions Locator scan positioning networks offer improved positional consistency compared to manual slice positionings and verified inter-operator variance as an important source of error. By significantly reducing operator-related decisions, this method opens opportunities to standardize and simplify the workflow of bolus tracking procedures for contrast-enhanced CT.