Mina Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mina Lee has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Sihwa Joo
Safety Measurement Institute, Korea Research Institute of Standards and Science, Daejeon 34113, Republic of Korea
5 shared publications- Tae Geol Lee
Korea Research Institute of Standards and Science
2 shared publications Ui Jin Lee
2 shared publicationsBong H Chung
Bionanotechnology Research Center, Korea Research Institute of Bioscience and Biotechnology, Daejeon 34141, Republic of Korea
1 shared publication- Hak-Sung Jung
Quantum Magnetic Imaging Team, Korea Research Institute of Standards and Science, Daejeon 34113, Republic of Korea
1 shared publication Hye Young Son
Department of Radiology, College of Medicine, Yonsei University, Seoul 03722, South Korea
1 shared publication
Latest Publications
- Open Access
- 4 April 2025
- Published by Elsevier in Chemical Engineering Journal
- Vol. 511
Highly accurate multiplexed nanoplasmonic detection of microRNAs using splinted ligation
- 4 April 2025
- Published by Elsevier in Chemical Engineering Journal
- Vol. 511
Open AccessHighly accurate multiplexed nanoplasmonic detection of microRNAs using splinted ligation
- Open Access
- 21 June 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (28) , 33425-33436
Mesoporous Polydopamine-Encapsulated Fluorescent Nanodiamonds: A Versatile Platform for Biomedical Applications
Fluorescent nanodiamonds (FNDs) are versatile nanomaterials with promising properties. However, efficient functionalization of FNDs for biomedical applications remains challenging. In this study, we demonstrate mesoporous polydopamine (mPDA) encapsulation of FNDs. The mPDA shell is generated by sequential formation of micelles via self-assembly of Pluronic F127 (F127) with 1,3,5-trimethyl benzene (TMB) and composite micelles via oxidation and self-polymerization of dopamine hydrochloride (DA). The surface of the mPDA shell can be readily functionalized with thiol-terminated methoxy polyethylene glycol (mPEG-SH), hyperbranched polyglycerol (HPG), and d-α-tocopheryl polyethylene glycol 1000 succinate (TPGS). The PEGylated FND@mPDA particles are efficiently taken up by, and employed as a fluorescent imaging probe for, HeLa cells. HPG-functionalized FND@mPDA is conjugated with an amino-terminated oligonucleotide to detect microRNA via hybridization. Finally, the increased surface area of the mPDA shell permits efficient loading of doxorubicin hydrochloride. Further modification with TPGS increases drug delivery efficiency, resulting in high toxicity to cancer cells.
- 21 June 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (28) , 33425-33436
Open AccessMesoporous Polydopamine-Encapsulated Fluorescent Nanodiamonds: A Versatile Platform for Biomedical Applications
Fluorescent nanodiamonds (FNDs) are versatile nanomaterials with promising properties. However, efficient functionalization of FNDs for biomedical applications remains challenging. In this study, we demonstrate mesoporous polydopamine (mPDA) encapsulation of FNDs. The mPDA shell is generated by sequential formation of micelles via self-assembly of Pluronic F127 (F127) with 1,3,5-trimethyl benzene (TMB) and composite micelles via oxidation and self-polymerization of dopamine hydrochloride (DA). The surface of the mPDA shell can be readily functionalized with thiol-terminated methoxy polyethylene glycol (mPEG-SH), hyperbranched polyglycerol (HPG), and d-α-tocopheryl polyethylene glycol 1000 succinate (TPGS). The PEGylated FND@mPDA particles are efficiently taken up by, and employed as a fluorescent imaging probe for, HeLa cells. HPG-functionalized FND@mPDA is conjugated with an amino-terminated oligonucleotide to detect microRNA via hybridization. Finally, the increased surface area of the mPDA shell permits efficient loading of doxorubicin hydrochloride. Further modification with TPGS increases drug delivery efficiency, resulting in high toxicity to cancer cells.
- Open Access
- 9 March 2023
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 44 (6) , 536-541
Quantitative evaluation of brightness of fluorescent nanoparticles usingDNAorigami standards
Fluorescent nanoparticles (FNPs) are widely used in various applications owing to their brightness, stability, and biocompatibility. When FNPs are used as probes, the quantities of the targets are estimated from the fluorescence generated by the probes. Information on the brightness of FNPs is thus essential for the reliable analysis of targets; however, accurate methods to measure it have not been established yet. Here, we present a novel method that quantitatively evaluates the brightness of FNPs, using DNA origami as a standard. DNA origami particles labeled with different numbers of fluorophores are imaged, and their brightness is analyzed at the single‐particle level. By comparing with the origami data, the brightness of two commercially available FNPs was determined in terms of the equivalent number of fluorophores (ENF). This method is easy to implement because DNA origami standards with various fluorophores and stoichiometry can be readily prepared.
- 9 March 2023
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 44 (6) , 536-541
Open AccessQuantitative evaluation of brightness of fluorescent nanoparticles usingDNAorigami standards
Fluorescent nanoparticles (FNPs) are widely used in various applications owing to their brightness, stability, and biocompatibility. When FNPs are used as probes, the quantities of the targets are estimated from the fluorescence generated by the probes. Information on the brightness of FNPs is thus essential for the reliable analysis of targets; however, accurate methods to measure it have not been established yet. Here, we present a novel method that quantitatively evaluates the brightness of FNPs, using DNA origami as a standard. DNA origami particles labeled with different numbers of fluorophores are imaged, and their brightness is analyzed at the single‐particle level. By comparing with the origami data, the brightness of two commercially available FNPs was determined in terms of the equivalent number of fluorophores (ENF). This method is easy to implement because DNA origami standards with various fluorophores and stoichiometry can be readily prepared.
- 24 October 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (11) , 3409-3415
Highly Selective FRET-Aided Single-Molecule Counting of MicroRNAs Labeled by Splinted Ligation
MicroRNAs (miRNAs) are short non-coding RNAs that play an important role in regulating gene expression. Since miRNAs are abnormally expressed in various cancers, they are considered to be promising biomarkers for early cancer diagnosis. However, the short length and strong sequence similarity among miRNAs make their reliable quantification very challenging. We developed a highly selective amplification-free miRNA detection method based on Fo''rster resonance energy transfer (FRET)-aided single-molecule counting. miRNAs were selectively labeled with FRET probes using splinted ligation. When imaged with a single-molecule FRET setup, the miRNA molecules were accurately identified by the probe's FRET. miRNA concentrations were estimated from the count of molecules. The high sensitivity of the method in finding sparse molecules enabled us to achieve a limit of detection of 31-56 amol for miR-125b, miR-100, and miR-99a. Single nucleotide mismatch could be discriminated with a very high target-to-mismatch ratio. The method accurately measured the high expression of miR-125b in gastric cancer cells, which agreed well with previous reports. The high sensitivity and accuracy of this technique demonstrated its clinical potential as a robust miRNA detection method.
- 24 October 2022
- Published by American Chemical Society (ACS) in ACS Sensors
- Vol. 7 (11) , 3409-3415
Highly Selective FRET-Aided Single-Molecule Counting of MicroRNAs Labeled by Splinted Ligation
MicroRNAs (miRNAs) are short non-coding RNAs that play an important role in regulating gene expression. Since miRNAs are abnormally expressed in various cancers, they are considered to be promising biomarkers for early cancer diagnosis. However, the short length and strong sequence similarity among miRNAs make their reliable quantification very challenging. We developed a highly selective amplification-free miRNA detection method based on Fo''rster resonance energy transfer (FRET)-aided single-molecule counting. miRNAs were selectively labeled with FRET probes using splinted ligation. When imaged with a single-molecule FRET setup, the miRNA molecules were accurately identified by the probe's FRET. miRNA concentrations were estimated from the count of molecules. The high sensitivity of the method in finding sparse molecules enabled us to achieve a limit of detection of 31-56 amol for miR-125b, miR-100, and miR-99a. Single nucleotide mismatch could be discriminated with a very high target-to-mismatch ratio. The method accurately measured the high expression of miR-125b in gastric cancer cells, which agreed well with previous reports. The high sensitivity and accuracy of this technique demonstrated its clinical potential as a robust miRNA detection method.
- 25 June 2022
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 43 (8) , 1069-1074
Effect of time‐gating on stimulated emission depletion microscopy using sub‐nanosecond pulses
Stimulated emission depletion (STED) microscopy is a super‐resolution microscopy technique that overcomes the diffraction limit using a donut‐shaped beam switching off fluorescence through stimulated emission. Because the resolution of STED microscopy is directly affected by beam intensity, a light source for the donut beam is very important. Because of their output power, cost, and convenience, sub‐nanosecond fiber lasers have become popular. However, their pulses (approximately 500 ps) are somewhat long, which can degrade the resolution. In this study, we used time‐gating to improve the resolution of an STED microscope built with a sub‐nanosecond fiber laser. Quantitative analysis of single DNA origami bead images revealed that time‐gating increased the resolution and signal‐to‐background ratio by 15% and twofold, respectively. A similar effect was observed in cell imaging. This result suggests that time‐gating would be beneficial for STED microscopes using slightly long pulses.
- 25 June 2022
- Published by Wiley in Bulletin of the Korean Chemical Society
- Vol. 43 (8) , 1069-1074
Effect of time‐gating on stimulated emission depletion microscopy using sub‐nanosecond pulses
Stimulated emission depletion (STED) microscopy is a super‐resolution microscopy technique that overcomes the diffraction limit using a donut‐shaped beam switching off fluorescence through stimulated emission. Because the resolution of STED microscopy is directly affected by beam intensity, a light source for the donut beam is very important. Because of their output power, cost, and convenience, sub‐nanosecond fiber lasers have become popular. However, their pulses (approximately 500 ps) are somewhat long, which can degrade the resolution. In this study, we used time‐gating to improve the resolution of an STED microscope built with a sub‐nanosecond fiber laser. Quantitative analysis of single DNA origami bead images revealed that time‐gating increased the resolution and signal‐to‐background ratio by 15% and twofold, respectively. A similar effect was observed in cell imaging. This result suggests that time‐gating would be beneficial for STED microscopes using slightly long pulses.
- Open Access
- 29 October 2019
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 47 (21) , 11344-11354
Ring-shaped replicative helicase encircles double-stranded DNA during unwinding
Ring-shaped replicative helicases are hexameric and play a key role in cellular DNA replication. Despite their importance, our understanding of the unwinding mechanism of replicative helicases is far from perfect. Bovine papillomavirus E1 is one of the best-known model systems for replicative helicases. E1 is a multifunctional initiator that senses and melts the viral origin and unwinds DNA. Here, we study the unwinding mechanism of E1 at the single-molecule level using magnetic tweezers. The result reveals that E1 as a single hexamer is a poorly processive helicase with a low unwinding rate. Tension on the DNA strands impedes unwinding, indicating that the helicase interacts strongly with both DNA strands at the junction. While investigating the interaction at a high force (26–30 pN), we discovered that E1 encircles dsDNA. By comparing with the E1 construct without a DNA binding domain, we propose two possible encircling modes of E1 during active unwinding.
- 29 October 2019
- Published by Oxford University Press (OUP) in Nucleic Acids Research
- Vol. 47 (21) , 11344-11354
Open AccessRing-shaped replicative helicase encircles double-stranded DNA during unwinding
Ring-shaped replicative helicases are hexameric and play a key role in cellular DNA replication. Despite their importance, our understanding of the unwinding mechanism of replicative helicases is far from perfect. Bovine papillomavirus E1 is one of the best-known model systems for replicative helicases. E1 is a multifunctional initiator that senses and melts the viral origin and unwinds DNA. Here, we study the unwinding mechanism of E1 at the single-molecule level using magnetic tweezers. The result reveals that E1 as a single hexamer is a poorly processive helicase with a low unwinding rate. Tension on the DNA strands impedes unwinding, indicating that the helicase interacts strongly with both DNA strands at the junction. While investigating the interaction at a high force (26–30 pN), we discovered that E1 encircles dsDNA. By comparing with the E1 construct without a DNA binding domain, we propose two possible encircling modes of E1 during active unwinding.