Haruka Yokota
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Haruka Yokota has a total of 4 co-authors. Here are the top co-authors by number of shared publications:
- Hiroaki Yokota
Affiliation The Graduate School for the Creation of New Photonics Industries, Hamamatsu, Japan
1 shared publication - Masahiro Ohsawa
Laboratory of Systems Pharmacology, Faculty of Pharmaceutical Sciences, Teikyo University, Tokyo, Japan
1 shared publication - Shisei Kubo
Division of Cariology and Restorative Dentistry, Nagasaki University Graduate School of Biomedical Sciences, Nagasaki, Japan
1 shared publication - Yoshihiko Hayashi
Department of Chemistry, Graduate School of Science, Osaka University, 1-1 Machikaneyama-cho, Toyonaka, Osaka 560-0043, Japan
1 shared publication
Latest Publications
- Open Access
- 1 January 2006
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 25 (1) , 66-74
Effect of a Caries-detecting Solution on the Tensile Bond Strength of Four Dentin Adhesive Systems
This study investigated the effect of a caries-detecting solution on the tensile bond strength (TBS) to sound bovine dentin - which was either rinsed thoroughly of or contaminated with the caries-detecting solution. Caries Detector (1.0% acid red in propylene glycol) was applied on flat dentin surfaces for 10 seconds, rinsed, and dried with syringe air. In another group, Caries Detector was not rinsed but air-dried. Then, the surfaces were treated with one of the following adhesive systems: Clearfil Protect Bond, Clearfil SE Bond, One-Up Bond F, or Single Bond. Furthermore, an ingredient of Caries Detector, either 1.0% acid red aqueous solution or propylene glycol, was applied to evaluate the effect of each component. In the control groups, Caries Detector was not applied to the dentin surfaces. Finally, a resin composite was light-cured and the TBS measured. Fractured specimens and treated dentin surfaces were observed by SEM. Caries Detector did not reduce the tensile bond strength of any adhesive system (p>0.05) when rinsed thoroughly. On the other hand, when dentin surface was contaminated with Caries Detector, TBS decreased significantly with Clearfil SE Bond and Single Bond. As for the ingredients of Caries Detector, the effect of acid red on TBS was not significant, but that of propylene glycol was significant
- 1 January 2006
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 25 (1) , 66-74
Open AccessEffect of a Caries-detecting Solution on the Tensile Bond Strength of Four Dentin Adhesive Systems
This study investigated the effect of a caries-detecting solution on the tensile bond strength (TBS) to sound bovine dentin - which was either rinsed thoroughly of or contaminated with the caries-detecting solution. Caries Detector (1.0% acid red in propylene glycol) was applied on flat dentin surfaces for 10 seconds, rinsed, and dried with syringe air. In another group, Caries Detector was not rinsed but air-dried. Then, the surfaces were treated with one of the following adhesive systems: Clearfil Protect Bond, Clearfil SE Bond, One-Up Bond F, or Single Bond. Furthermore, an ingredient of Caries Detector, either 1.0% acid red aqueous solution or propylene glycol, was applied to evaluate the effect of each component. In the control groups, Caries Detector was not applied to the dentin surfaces. Finally, a resin composite was light-cured and the TBS measured. Fractured specimens and treated dentin surfaces were observed by SEM. Caries Detector did not reduce the tensile bond strength of any adhesive system (p>0.05) when rinsed thoroughly. On the other hand, when dentin surface was contaminated with Caries Detector, TBS decreased significantly with Clearfil SE Bond and Single Bond. As for the ingredients of Caries Detector, the effect of acid red on TBS was not significant, but that of propylene glycol was significant