RMRion Morishita

Rion Morishita

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Rion Morishita has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • High-speed full-field swept-source dynamic optical coherence tomography enabled by neural-network-based image generation

    by Suzuyo Komeda, Nobuhisa Tateno, Yusong Liu, Rion Morishita, Xibo Wang, Ibrahim Abd El-Sadek, Atsuko Furukawa, Satoshi Matsusaka, Shuichi Makita, Yoshiaki Yasuno

    We demonstrate neural-network-based high-speed and high-definition dynamic full-field swept-source optical coherence microscopy (D-FF-SSOCM). FF-SSOCM provides high-definition OCT images, but, particularly in DOCT imaging, it results in a significant enlargement of the data size and subsequently long data streaming and processing time, which prevents high-throughput imaging. We address this issue by introducing an NN-based DOCT method that generates high-definition logarithmic intensity variance (LIV) -based DOCT images from only four OCT volumes, whereas the conventional method required 32 volumes. The NN model successfully generates an LIV image that is qualitatively and quantitatively similar to the LIV image computed from 32 volumes. This approach significantly reduces data size and transfer time by a factor of eight for DOCT imaging, and consequently, the signal processing time is also significantly reduced. Specifically, these were reduced from 41 GB to 5.1 GB, 7.2 min to 54 s, and 3.3 hours to 57 min, respectively.


  • Dynamic full-field swept-source optical coherence tomography for high-resolution, long-depth, and intratissue-activity imaging

    by Nobuhisa Tateno, Yue Zhu, Suzuyo Komeda, Mahiro Ishikawa, Xibo Wang, Ibrahim Abd El-Sadek, Rion Morishita, Atsuko Furukawa, Satoshi Matsusaka, Shuichi Makita, et al.

    Optical coherence tomography (OCT) may use a high-numerical-aperture objective to achieve high lateral resolution. However, its practical imaging depth range is limited by the depth of focus (DOF). Although computational refocusing can potentially provide sharp images outside the DOF, signal reduction by the confocal effect still limits the imaging depth in practice in point-scanning OCT. In addition, standard OCT cannot visualize intra-tissue activities. To overcome these limitations, we demonstrate a dynamic spatially-coherent full-field OCT (dynamic SC-FFOCT). This modality uses computational refocusing to extend the imaging depth and a repetitive acquisition protocol for dynamic OCT imaging that visualizes intra-tissue activities. In addition, a repetitive acquisition protocol was designed to visualize intra-tissue activities (i.e., dynamic OCT imaging). The in-focus lateral resolution is 1.4 µm, and the axial resolution is 6.5 µm (in air) at full-width at half-maximum intensity. Three-dimensional structure and the dynamic OCT imaging using SC-FFOCT with computational refocusing was applied to human breast adenocarcinoma spheroids (MCF-7 cell line). Volumetric dynamic imaging with high lateral resolution is demonstrated over the full depth of the spheroid.


  • In vivo dynamic optical coherence tomography of human skin with hardware- and software-based motion correction

    by Yu Guo, Rion Morishita, Ibrahim Abd El-Sadek, Kohei Yamazaki, Shingo Sakai, Pradipta Mukherjee, Yiheng Lim, Cunyou Bao, Haotian Li, Keiichi Sugata, et al.

    In vivo application of dynamic optical coherence tomography (DOCT) is hindered by bulk motion of the sample. We demonstrate DOCT imaging of in vivo human skin by adopting a sample-fixation attachment to suppress bulk motion and a subsequent software motion correction to further reduce the effect of sample motion. The performance of the motion-correction method was assessed by DOCT image observation, statistical analysis of the mean DOCT values, and subjective image grading. Both the mean DOCT value analysis and subjective grading showed statistically significant improvement of the DOCT image quality. In addition, a previously unobserved high DOCT layer was identified though image observation, which may represent the stratum basale with high keratinocyte proliferation.


  • Dynamic optical coherence tomography algorithm for label-free assessment of swiftness and occupancy of intratissue moving scatterers

    by Rion Morishita, Pradipta Mukherjee, Ibrahim Abd El-Sadek, Tanatchaya Seesan, Tomoko Mori, Atsuko Furukawa, Shinichi Fukuda, Donny Lukmanto, Satoshi Matsusaka, Shuichi Makita, et al.

    Dynamic optical coherence tomography (DOCT) statistically analyzes fluctuations in time-sequential OCT signals, enabling label-free and three-dimensional visualization of intratissue and intracellular activities. Current DOCT methods, such as logarithmic intensity variance (LIV) and OCT correlation decay speed (OCDS), have several limitations. Namely, the DOCT values and intratissue motions are not directly related, and hence DOCT values are not interpretable in the context of the tissue motility. We introduce an open-source DOCT algorithm that provides a more direct interpretation of DOCT in the context of dynamic scatterer ratio and scatterer speed in the tissue. The detailed properties of the new and conventional DOCT methods are investigated by numerical simulations based on our open-source DOCT simulation framework, and the experimental validation with in vitro and ex vivo samples demonstrates the feasibility of the method.


  • Open Access

    Guide to dynamic OCT data analysis

    by Noah Heldt, Tual Monfort, Rion Morishita, Robert Schönherr, Olivier Thouvenin, Ibrahim Abd El-Sadek, Peter König, Gereon Hüttmann, Kate Grieve, Yoshiaki Yasuno

    Dynamic optical coherence tomography (DOCT) enhances conventional OCT by providing specific information related to flow dynamics, cell motility, and organelle metabolic activity. These biological phenomena can be detected with varying sensitivity depending on the OCT architecture parameters, including wavelength, numerical aperture, and implementation method (time domain or Fourier domain). Despite its potential, the field lacks standardization as various research groups have independently developed algorithms for specific applications. In this paper, we compare four widely used DOCT algorithms, each employing a distinct analytical approach: power spectral density moment analysis, frequency band visualization, logarithmic intensity variation evaluation, and motility-based analysis. These algorithms were originally optimized for different OCT technologies (full-field OCT, microscopic OCT, swept-source OCT, and spectral domain OCT), which vary in temporal and spatial resolution as well as susceptibility to motion artifacts. To conduct a fair evaluation, we perform comprehensive cross-wise comparisons using datasets acquired from each of these setups. Our findings reveal that each method exhibits unique advantages in specific imaging environments, thereby providing valuable guidance for algorithm selection based on particular application requirements.


  • Experimental and numerical investigation of wavelength and resolution dependency of dynamic optical coherence tomography signals

    by Shumpei Fujimura, Ibrahim Abd El-Sadek, Rion Morishita, Shuichi Makita, Atsuko Furukawa, Pradipta Mukherjee, Yiheng Lim, Lida Zhu, Yunake Feng, Thitiya Seesan, et al.

    The wavelength and system-resolution dependencies of dynamic optical coherence tomography (DOCT) are investigated experimentally and numerically. Experimental investigations demonstrate significant wavelength dependency for the DOCT values but no marked resolution dependency. Numerical simulations were performed using diffusion, random-ballistic motion, and mono-directional flow-based motion models. Diffusion and random-ballistic motion-based simulations show significant wavelength dependency. Additionally, these simulations revealed a small but certain resolution dependency. Mono-directional flow simulations did not show wavelength dependency but did demonstrate resolution dependency. The DOCT value is sensitive to both tissue dynamics and the OCT system specification. These effects should be considered when interpreting DOCT images.


  • Dynamic-OCT simulation framework based on mathematical models of intratissue dynamics, image formation, and measurement noise

    by Yuanke Feng, Shumpei Fujimura, Yiheng Lim, Thitiya Seesan, Rion Morishita, Ibrahim Abd El-Sadek, Pradipta Mukherjee, Shuichi Makita, Yoshiaki Yasuno

    Dynamic optical coherence tomography (DOCT) enables label-free functional imaging by capturing temporal OCT signal variations caused by intracellular and intratissue motions. However, the relationship between DOCT signals and the sample motion behind them remains unclear. This paper presents a comprehensive DOCT simulation framework that incorporates mathematical models of intracellular/intratissue motions, two OCT signal generator types that generate OCT signal time sequences from the moving scatterer models, and representative DOCT algorithms. The theory and algorithms of the framework are described in detail, and the utility of this framework is demonstrated through numerical studies. This framework is available as open source and will enhance the understanding and utility of DOCT.


  • Neural-network based high-speed volumetric dynamic optical coherence tomography

    by Yusong Liu, Ibrahim Abd El-Sadek, Rion Morishita, Shuichi Makita, Tomoko Mori, Atsuko Furukawa, Satoshi Matsusaka, Yoshiaki Yasuno

    We demonstrate deep-learning neural network (NN)-based dynamic optical coherence tomography (DOCT), which generates high-quality logarithmic-intensity-variance (LIV) DOCT images from only four OCT frames. The NN model is trained for tumor spheroid samples using a customized loss function: the weighted mean absolute error. This loss function enables highly accurate LIV image generation. The fidelity of the generated LIV images to the ground truth LIV images generated using 32 OCT frames is examined via subjective image observation and statistical analysis of image-based metrics. Fast volumetric DOCT imaging with an acquisition time of 6.55 s/volume is demonstrated using this NN-based method.


  • Open Access

    Label-free visualization and quantification of the drug-type-dependent response of tumor spheroids by dynamic optical coherence tomography

    by Ibrahim Abd El-Sadek, Rion Morishita, Tomoko Mori, Shuichi Makita, Pradipta Mukherjee, Satoshi Matsusaka, Yoshiaki Yasuno

    We demonstrate label-free dynamic optical coherence tomography (D-OCT)-based visualization and quantitative assessment of patterns of tumor spheroid response to three anti-cancer drugs. The study involved treating human breast adenocarcinoma (MCF-7 cell-line) with paclitaxel (PTX), tamoxifen citrate (TAM), and doxorubicin (DOX) at concentrations of 0 (control), 0.1, 1, and 10 μM for 1, 3, and 6 days. In addition, fluorescence microscopy imaging was performed for reference. The D-OCT imaging was performed using a custom-built OCT device. Two algorithms, namely logarithmic intensity variance (LIV) and late OCT correlation decay speed (OCDS l ) were used to visualize the tissue dynamics. The spheroids treated with 0.1 and 1 μM TAM appeared similar to the control spheroid, whereas those treated with 10 μM TAM had significant structural corruption and decreasing LIV and OCDS l over treatment time. The spheroids treated with PTX had decreasing volumes and decrease of LIV and OCDS l signals over time at most PTX concentrations. The spheroids treated with DOX had decreasing and increasing volumes over time at DOX concentrations of 1 and 10 μM, respectively. Meanwhile, the LIV and OCDS l signals decreased over treatment time at all DOX concentrations. The D-OCT, particularly OCDS l , patterns were consistent with the fluorescence microscopic patterns. The diversity in the structural and D-OCT results among the drug types and among the concentrations are explained by the mechanisms of the drugs. The presented results suggest that D-OCT is useful for evaluating the difference in the tumor spheroid response to different drugs and it can be a useful tool for anti-cancer drug testing.

  • Open Access

    Theoretical model for en face optical coherence tomography imaging and its application to volumetric differential contrast imaging

    by Kiriko Tomita, Shuichi Makita, Naoki Fukutake, Rion Morishita, Ibrahim Abd El-Sadek, Pradipta Mukherjee, Antonia Lichtenegger, Junya Tamaoki, Lixuan Bian, Makoto Kobayashi, et al.

    A new formulation of the lateral imaging process of point-scanning optical coherence tomography (OCT) and a new differential contrast method designed by using this formulation are presented. The formulation is based on a mathematical sample model called the dispersed scatterer model (DSM), in which the sample is represented as a material with a spatially slowly varying refractive index and randomly distributed scatterers embedded in the material. It is shown that the formulation represents a meaningful OCT image and speckle as two independent mathematical quantities. The new differential contrast method is based on complex signal processing of OCT images, and the physical and numerical imaging processes of this method are jointly formulated using the same theoretical strategy as in the case of OCT. The formula shows that the method provides a spatially differential image of the sample structure. This differential imaging method is validated by measuring in vivo and in vitro samples.