HWHongzhi Wang

Hongzhi Wang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Hongzhi Wang has a total of 26 co-authors. Here are the top co-authors by number of shared publications:

  • Benli Yu

    School of Physics and Optoelectronic Engineering, Key Laboratory of Opto-Electronic Information Acquisition and Manipulation of Ministry of Education, Information Materials and Intelligent Sensing Laboratory of Anhui Province, Anhui University, Hefei, 230601, China

    3 shared publications
  • Hongtao Li

    School of Physics and Optoelectronic Engineering, State Key Laboratory of Opto-Electronic Information Acquisition and Protection Technology, Information Materials and Intelligent Sensing Laboratory of Anhui Province, Key Laboratory of Opto-Electronic Information Acquisition and Manipulation of Ministry of Education, Anhui University, Hefei, 230601, China; Institute of Environment, Hefei Comprehensive National Science Center, Hefei, 230088, China

    3 shared publications
  • Liang Lu

    School of Physics and Optoelectronic Engineering, Key Laboratory of Opto-Electronic Information Acquisition and Manipulation of Ministry of Education, Information Materials and Intelligent Sensing Laboratory of Anhui Province, Anhui University, Hefei, 230601, China

    3 shared publications
  • Chaozhao Liang

    Department of Urology the First Affiliated Hospital of Anhui Medical University Hefei China

    2 shared publications
  • Hao Yuan

    Information Materials and Intelligent Sensing Laboratory of Anhui Province, Anhui University, Hefei 230601, China

    2 shared publications
  • Lei Zhang

    Information Materials and Intelligent Sensing Laboratory of Anhui Province, Anhui University, Hefei 230601, China

    2 shared publications

Latest Publications

  • Single-port EDGE SP1000 versus multi-port Da Vinci Xi robot-assisted radical prostatectomy: a comparative analysis of technique and perioperative outcomes

    by Jialong Zhang, Longxiang Zhou, Hao Li, Hexi Du, Hongzhi Wang, Sheng Tai, Chaozhao Liang

    The EDGE single-port endoscopic surgical robot (SP1000), specifically designed for urological, gynecological, thoracic and general surgical procedures, has recently been applied in various operations. However, there is currently a lack of evidence comparing its performance with the Da Vinci Xi robot system. This study aims to compare the technique and perioperative outcomes of radical prostatectomy (RP) performed with EDGE SP1000 versus the Da Vinci Xi robot system. Data were collected from radical prostatectomy cases performed at Anhui Medical University from March 2025 to December 2025. 101 patients underwent radical prostatectomy using EDGE SP1000 and 102 patients using Da Vinci Xi were operated on using the Da Vinci Xi system. A 1:1 propensity score matching method was applied to compare the two groups both before and after matching based on age, body mass index, prostate size, prostate specific antigen (PSA) level, and Gleason score. We primarily evaluated the surgical efficacy of the two robotic systems by comparing perioperative clinical data. In the matched surgery groups (EDGE SP1000 vs. Da Vinci Xi), there were no significant differences in age (68.6 years vs. 69.3 years; p = 0.59), PSA (10.3 ng/ml vs. 10.1 ng/ml; p = 0.93), Gleason score (7 vs. 7; p = 0.41) and prostate volume (38.0 cm3 vs. 37.4 cm3; p = 0.81). All procedures were completed successfully without any conversion to open surgery. There was no significant difference in the total operative time between the two groups (136.6 vs. 129.0 min; p = 0.14). No major intra or postoperative complications were observed in either group. Positive surgical margin rates were no significant (36% vs. 41%; p = 0.41). Despite the design variations between the two robotic systems, there were no significant differences in the final surgical outcomes. The EDGE SP1000 system serves as a viable option for radical prostatectomy.

  • Open Access

    Interleukin expression patterns and immune cell infiltration in prostate adenocarcinoma: Implications for recurrence risk

    by Jialong Zhang, Cong Huang, Xu Wang, Jun He, Hongzhi Wang, Chaozhao Liang

    Objective: This study aims to comprehensively investigate the expression profiles of interleukins in prostate adenocarcinoma (PRAD) and their relationship with immune cell infiltration, tumor progression, and patient prognosis. By establishing an interleukin-related risk score, we seek to enhance the understanding of the tumor immune microenvironment and facilitate the development of tailored immunotherapeutic strategies for PRAD patients. Introduction: Interleukins can nurture a tumor promoting environment and simultaneously regulate immune cell infiltration. However, the potential roles of interleukins in the prostate adenocarcinoma immune landscape remain abstruse. Methods: We comprehensively investigated the interleukin expression patterns and tumor immune landscape of prostate adenocarcinoma patients. And explored the interleukin expression patterns with immune infiltration landscape. The interleukin score was established using LASSO cox regression analysis. Multivariate Cox regression analysis was employed to assess the prognostic value of the interleukin score. Results: We identified two distinct interleukin clusters, characterized by different immune cell infiltration, tumor promoting signaling pathways activation and prognosis. The interleukin score was established to estimate the prognosis of individual prostate adenocarcinoma (PRAD) patient. Further analysis demonstrated that the interleukin score was an independent prognostic factor of PRAD. Finally, we investigated the predictive value of interleukin score in the programmed cell death protein (PD-1) blockade therapy of patients with prostate adenocarcinoma. At the same time, the differences in related genes among different prostate cell lines were also identified. Conclusions: This study demonstrated the correlation between interleukin and tumor immune landscape in prostate adenocarcinoma. The comprehensive evaluation of interleukin expression patterns in individual prostate patients contribute to our understanding of the immune landscape and helps clinicians selecting proper immunotherapy strategies for prostate patients.


  • Combined Ultrasensitive Detection of Renal Cancer Proteins and Cells Using an Optical Microfiber Functionalized with Ti3C2 MXene and Gold Nanorod-Nanosensitized Interfaces

    by Hongtao Li, Tianqi Huang, Hao Yuan, Liang Lu, Zhigang Cao, Lei Zhang, Yu Yang, Benli Yu, Hongzhi Wang

    The ultrasensitive and quantitative detection of renal cancer protein biomarkers present at ultralow concentrations for early-stage cancer diagnosis requires a biosensing probe possessing ultrahigh detection sensitivity and remarkable biosensing selectivity. Here, we report an optical microfiber integrated with Ti3C2-supported gold nanorod hybrid nanointerfaces for implementation in ultrasensitive sensing of the carbonic anhydrase IX (CAIX) protein and renal cancer cells. Because the evanescent field of the fiber is strongly coupled with nanointerfaces in the near-infrared region, the proposed optical microfiber biosensor achieves ultrahigh-sensitivity detection of the CAIX protein biomarker with ultralow limits of detection (LODs) of 13.8 zM in pure buffer solution and 0.19 aM in 30% serum solution. In addition, the proposed sensor also successfully and specifically recognizes living renal cancer cells in cell culture media with a LOD of 180 cells/mL. This strategy may serves as a powerful biosensing platform that combines the quantification of protein biomarkers and cancer cells, resulting in a higher accuracy of early-stage renal cancer diagnosis and screenings.


  • Ultrasensitive Detection of Exosomes Using an Optical Microfiber Decorated with Plasmonic MoSe2-Supported Gold Nanorod Nanointerfaces

    by Hongtao Li, Tianqi Huang, Liang Lu, Hao Yuan, Lei Zhang, Hongzhi Wang, Benli Yu

    Exosomes are potential and promising natural noninvasive biomarkers for liquid biopsies and can be involved in various biological and pathological processes in early-stage cancer. Thus, there is an urgent demand to develop low-cost, small-size, remarkable-specificity, and ultrasensitive exosome biosensors for early clinical point-of-care (POC) testing. Although various conventional tumor exosome detection methods have been generally proposed, the low detection sensitivity and specificity significantly hinder their use in cancer clinical diagnosis and prognosis. To address the above challenges, an optical microfiber integrated with MoSe2-supported gold nanorods is proposed. To tune the strong localized surface plasmon resonance (LSPR) of the nanointerfaces on the optical microfiber to be in accordance with the operating wavelength of the silica optical microfiber in the telecommunication band, gold nanorods with a high aspect ratio of approximately 10:1 are proposed. Due to the interaction between the excited LSPR effect and the evanescent field of the optical microfiber, the sensor can detect clear cell renal cancer exosomes within a wide concentration range from 100 particles/mL to 108 particles/mL, with an extremely low limit of detection (LOD) of 9.32 particles/mL, which is lower than that of current various state of the art methods. More importantly, the microfiber with high specificity can successfully differentiate pathological plasma and healthy controls, exhibiting very promising clinical applications in renal cancer diagnosis and prognosis. This work opens up a new approach for the in situ detection and quantification of exosomes with ultrahigh sensitivity in early clinical screening and diagnosis.