Yi Hong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Yi Hong has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Biao Ma
Key Laboratory of Microbiological Metrology, Measurement & Bio-product Quality Security, State Administration for Market Regulation, College of Life Sciences, China Jiliang University, Hangzhou 310018, China
4 shared publications - Jiali Li
Hangzhou Quickgene Sci-Tech. Co., Ltd., Hangzhou 310018, China
4 shared publications - Mingzhou Zhang
Key Laboratory of Microbiological Metrology, Measurement & Bio-product Quality Security, State Administration for Market Regulation, College of Life Sciences, China Jiliang University, Hangzhou 310018, China
4 shared publications - Bei Jin
Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
2 shared publications - Hanyue Xu
College of Life Science, China JiLiang University, Hangzhou 310018, China
2 shared publications - Erjing Chen
Zhejiang Provincial Key Laboratory of Biometrology and Inspection & Quarantine, China Jiliang University, Hangzhou 310018, China
1 shared publication
Latest Publications
- Open Access
- 14 June 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (6) , 652
Europium Nanoparticle-Based Lateral Flow Strip Biosensors Combined with Recombinase Polymerase Amplification for Simultaneous Detection of Five Zoonotic Foodborne Pathogens
The five recognized zoonotic foodborne pathogens, namely, Listeria monocytogenes, Staphylococcus aureus, Streptococcus suis, Salmonella enterica and Escherichia coli O157:H7, pose a major threat to global health and social–economic development. These pathogenic bacteria can cause human and animal diseases through foodborne transmission and environmental contamination. Rapid and sensitive detection for pathogens is particularly important for the effective prevention of zoonotic infections. In this study, rapid and visual europium nanoparticle (EuNP)-based lateral flow strip biosensors (LFSBs) combined with recombinase polymerase amplification (RPA) were developed for the simultaneous quantitative detection of five foodborne pathogenic bacteria. Multiple T lines were designed in a single test strip for increasing the detection throughput. After optimizing the key parameters, the single-tube amplified reaction was completed within 15 min at 37 °C. The fluorescent strip reader recorded the intensity signals from the lateral flow strip and converted the data into a T/C value for quantification measurement. The sensitivity of the quintuple RPA-EuNP-LFSBs reached a level of 101 CFU/mL. It also exhibited good specificity and there was no cross-reaction with 20 non-target pathogens. In artificial contamination experiments, the recovery rate of the quintuple RPA-EuNP-LFSBs was 90.6–101.6%, and the results were consistent with those of the culture method. In summary, the ultrasensitive bacterial LFSBs described in this study have the potential for widespread application in resource-poor areas. The study also provides insights in respect to multiple detection in the field.
- 14 June 2023
- Published by MDPI AG in Biosensors
- Vol. 13 (6) , 652
Open AccessEuropium Nanoparticle-Based Lateral Flow Strip Biosensors Combined with Recombinase Polymerase Amplification for Simultaneous Detection of Five Zoonotic Foodborne Pathogens
The five recognized zoonotic foodborne pathogens, namely, Listeria monocytogenes, Staphylococcus aureus, Streptococcus suis, Salmonella enterica and Escherichia coli O157:H7, pose a major threat to global health and social–economic development. These pathogenic bacteria can cause human and animal diseases through foodborne transmission and environmental contamination. Rapid and sensitive detection for pathogens is particularly important for the effective prevention of zoonotic infections. In this study, rapid and visual europium nanoparticle (EuNP)-based lateral flow strip biosensors (LFSBs) combined with recombinase polymerase amplification (RPA) were developed for the simultaneous quantitative detection of five foodborne pathogenic bacteria. Multiple T lines were designed in a single test strip for increasing the detection throughput. After optimizing the key parameters, the single-tube amplified reaction was completed within 15 min at 37 °C. The fluorescent strip reader recorded the intensity signals from the lateral flow strip and converted the data into a T/C value for quantification measurement. The sensitivity of the quintuple RPA-EuNP-LFSBs reached a level of 101 CFU/mL. It also exhibited good specificity and there was no cross-reaction with 20 non-target pathogens. In artificial contamination experiments, the recovery rate of the quintuple RPA-EuNP-LFSBs was 90.6–101.6%, and the results were consistent with those of the culture method. In summary, the ultrasensitive bacterial LFSBs described in this study have the potential for widespread application in resource-poor areas. The study also provides insights in respect to multiple detection in the field.
- Open Access
Triplex-Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Immunoassay for the Simultaneous Detection of Three Pathogens of Porcine Viral Diarrhea Syndrome in Swine
Porcine epidemic diarrhea virus (PEDV), porcine bocavirus (PBoV), and porcine rotavirus (PoRV) are associated with porcine viral diarrhea. In this study, triplex loop-mediated isothermal amplification (LAMP) combined with a lateral flow dipstick (LFD) was established for the simultaneous detection of PEDV, PoRV, and PBoV. The PEDV-gp6, PoRV-vp6, and PBoV-vp1 genes were selected to design LAMP primers. The amplification could be carried out at 64 °C using a miniature metal bath within 30 min. The triplex LAMP–LFD assay exhibited no cross-reactions with other porcine pathogens. The limits of detection (LODs) of PEDV, PoRV, and PBoV were 2.40 × 101 copies/μL, 2.89 × 101 copies/μL, and 2.52 × 101 copies/μL, respectively. The consistency between rt-qPCR and the triplex LAMP–LFD was over 99% in field samples testing. In general, the triplex LAMP–LFD assay was suitable for the rapid and simultaneous detection of the three viruses in the field.
Open AccessTriplex-Loop-Mediated Isothermal Amplification Combined with a Lateral Flow Immunoassay for the Simultaneous Detection of Three Pathogens of Porcine Viral Diarrhea Syndrome in Swine
Porcine epidemic diarrhea virus (PEDV), porcine bocavirus (PBoV), and porcine rotavirus (PoRV) are associated with porcine viral diarrhea. In this study, triplex loop-mediated isothermal amplification (LAMP) combined with a lateral flow dipstick (LFD) was established for the simultaneous detection of PEDV, PoRV, and PBoV. The PEDV-gp6, PoRV-vp6, and PBoV-vp1 genes were selected to design LAMP primers. The amplification could be carried out at 64 °C using a miniature metal bath within 30 min. The triplex LAMP–LFD assay exhibited no cross-reactions with other porcine pathogens. The limits of detection (LODs) of PEDV, PoRV, and PBoV were 2.40 × 101 copies/μL, 2.89 × 101 copies/μL, and 2.52 × 101 copies/μL, respectively. The consistency between rt-qPCR and the triplex LAMP–LFD was over 99% in field samples testing. In general, the triplex LAMP–LFD assay was suitable for the rapid and simultaneous detection of the three viruses in the field.
- Open Access
Antibodies Induced by Homologous or Heterologous Inactivated (CoronaVac/BBIBP-CorV) and Recombinant Protein Subunit Vaccines (ZF2001) Dramatically Enhanced Inhibitory Abilities against B.1.351, B.1.617.2, and B.1.1.529 Variants
Safe and effective vaccines for Corona Virus Disease 2019 (COVID-19) can prevent the virus from infecting human populations and treat patients infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this study, we discuss the inhibitory abilities of primary and booster vaccine-induced antibodies inhibitory ability toward the SARS-CoV-2 wild-type strain, as well as B.1.1.7, B.1.351, P.1, B.1.617.2, and B.1.1.529. We confirmed these antibodies had the strongest inhibitory effects on the wild-type strain and cross-inhibition activities against other mutant strains after two inactivated vaccine doses. However, the B.1.351, B.1.617.2 and B.1.1.529 mutants exhibit antibody resistance in the vaccine serum. Antibodies induced by homologous inactivated vaccines (n = 92) presented more effective inhibition against tested SARS-CoV-2 strains (p < 0.0001), especially B.1.351, B.1.617.2, and B.1.1.529 mutant strains, which had strong immune escape characteristics. In addition, a heterologous booster vaccination (n = 50) of a protein subunit vaccine ZifiVax (ZF2001) significantly restored humoral immune responses and even showed an increasing response against wild-type, B.1.351, B.1.617.2, and B.1.1.529 than homologous inactivated vaccines. Our analysis of the humoral immune response elicited by the different vaccine regimens, including inhibiting antibodies, indicated that a booster, whether homologous or heterologous, could be essential for achieving greater efficacy against SARS-CoV-2.
Open AccessAntibodies Induced by Homologous or Heterologous Inactivated (CoronaVac/BBIBP-CorV) and Recombinant Protein Subunit Vaccines (ZF2001) Dramatically Enhanced Inhibitory Abilities against B.1.351, B.1.617.2, and B.1.1.529 Variants
Safe and effective vaccines for Corona Virus Disease 2019 (COVID-19) can prevent the virus from infecting human populations and treat patients infected with severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2). In this study, we discuss the inhibitory abilities of primary and booster vaccine-induced antibodies inhibitory ability toward the SARS-CoV-2 wild-type strain, as well as B.1.1.7, B.1.351, P.1, B.1.617.2, and B.1.1.529. We confirmed these antibodies had the strongest inhibitory effects on the wild-type strain and cross-inhibition activities against other mutant strains after two inactivated vaccine doses. However, the B.1.351, B.1.617.2 and B.1.1.529 mutants exhibit antibody resistance in the vaccine serum. Antibodies induced by homologous inactivated vaccines (n = 92) presented more effective inhibition against tested SARS-CoV-2 strains (p < 0.0001), especially B.1.351, B.1.617.2, and B.1.1.529 mutant strains, which had strong immune escape characteristics. In addition, a heterologous booster vaccination (n = 50) of a protein subunit vaccine ZifiVax (ZF2001) significantly restored humoral immune responses and even showed an increasing response against wild-type, B.1.351, B.1.617.2, and B.1.1.529 than homologous inactivated vaccines. Our analysis of the humoral immune response elicited by the different vaccine regimens, including inhibiting antibodies, indicated that a booster, whether homologous or heterologous, could be essential for achieving greater efficacy against SARS-CoV-2.
- Open Access
- 5 July 2022
- Published by MDPI AG in Microorganisms
- Vol. 10 (7) , 1352
Simultaneous Detection of Five Foodborne Pathogens Using a Mini Automatic Nucleic Acid Extractor Combined with Recombinase Polymerase Amplification and Lateral Flow Immunoassay
In recent years, foodborne disease outbreaks have caused huge losses to the economy and have had severe impacts on public health. The accuracy and variety of detection techniques is crucial to controlling the outbreak and spread of foodborne diseases. The need for instruments increases the difficulty of field detection, while manually-handled samples are subject to user error and subjective interpretation. Here, we use a mini automatic nucleic acid extractor combined with recombinant polymerase amplification (RPA) and lateral flow immunoassay (LFIA) for simultaneous quantitative detection of five major foodborne pathogens. The pre-treatment device using the magnetic bead method allows for nucleic acid extraction of the reagent tank without manual operation, which is highly efficient and stable for preventing aerosol contamination. The nuc gene of Staphylococcus aureus, the toxR gene of Vibrio parahaemolyticus, the rfbE gene of Escherichia coli O157:H7, the hlyA gene of Listeria monocytogenes, and the fimY gene of Salmonella enterica were used as target fragments. The labeled antibody concentration is optimized on the LFIA to find the equilibrium point for the binding capacity of the five chemical markers and to efficiently and accurately visualize the bands. The RPA assay shows an optimal performance at 37 °C for 15 min. The optimized RPA-LFIA detection limit can reach 101 CFU/mL. There was no cross-reactivity among forty-eight strains. Furthermore, the average recoveries in spiked food samples were 90.5–104.5%. In summary, the RPA-LFIA established in this study can detect five pathogenic bacteria simultaneously with little dependence on laboratory equipment, and it has promising prospects for screening in low-resource areas.
- 5 July 2022
- Published by MDPI AG in Microorganisms
- Vol. 10 (7) , 1352
Open AccessSimultaneous Detection of Five Foodborne Pathogens Using a Mini Automatic Nucleic Acid Extractor Combined with Recombinase Polymerase Amplification and Lateral Flow Immunoassay
In recent years, foodborne disease outbreaks have caused huge losses to the economy and have had severe impacts on public health. The accuracy and variety of detection techniques is crucial to controlling the outbreak and spread of foodborne diseases. The need for instruments increases the difficulty of field detection, while manually-handled samples are subject to user error and subjective interpretation. Here, we use a mini automatic nucleic acid extractor combined with recombinant polymerase amplification (RPA) and lateral flow immunoassay (LFIA) for simultaneous quantitative detection of five major foodborne pathogens. The pre-treatment device using the magnetic bead method allows for nucleic acid extraction of the reagent tank without manual operation, which is highly efficient and stable for preventing aerosol contamination. The nuc gene of Staphylococcus aureus, the toxR gene of Vibrio parahaemolyticus, the rfbE gene of Escherichia coli O157:H7, the hlyA gene of Listeria monocytogenes, and the fimY gene of Salmonella enterica were used as target fragments. The labeled antibody concentration is optimized on the LFIA to find the equilibrium point for the binding capacity of the five chemical markers and to efficiently and accurately visualize the bands. The RPA assay shows an optimal performance at 37 °C for 15 min. The optimized RPA-LFIA detection limit can reach 101 CFU/mL. There was no cross-reactivity among forty-eight strains. Furthermore, the average recoveries in spiked food samples were 90.5–104.5%. In summary, the RPA-LFIA established in this study can detect five pathogenic bacteria simultaneously with little dependence on laboratory equipment, and it has promising prospects for screening in low-resource areas.