FDFilippo Dell’agnello

Filippo Dell’agnello

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Filippo Dell’agnello has a total of 59 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Feasibility Study of a Sensorized Prosthetic Foot for Gait Monitoring and Prosthesis Control

    by Alessandro Mazzarini, Ilaria Fagioli, Filippo Dell’AGnello, Fabrizio Moncelli, Emanuele Gruppioni, Nicola Vitiello, Emilio Trigili, Simona Crea

    The assessment of gait parameters in daily life offers valuable insights for tailoring rehabilitation protocols and personalizing lower-limb assistive devices. Integrating sensory systems into prostheses may enable adaptive control and continuous gait monitoring. Traditional assessment methods such as motion capture, force platforms, and wearable Inertial Measurement Unit (IMU) are effective but often lack seamless integration with prostheses, limiting their use in everyday environments. This article presents a novel plantar sensory system designed for integration with lower-limb prostheses. The system employs optoelectronic plantar pressure sensors embedded between the prosthetic foot and cosmetic cover at load-bearing regions of the gait cycle. Endurance testing confirmed its robustness over prolonged use. Ten healthy subjects participated in a study evaluating the system’s ability to estimate vertical ground reaction force (vGRF) during walking. A Gaussian Process Regressor was trained on sensory signals with force plate data as ground truth. Using leave-one-subject-out cross-validation, the model showed good generalizability (R² = 0.94 ± 0.04), high correlation with force platform data (Pearson r = 0.94 (0.05)), and comparable peak vGRF values. Model stability was assessed by repeating the training 30 times, yielding a coefficient of variation of the RMSE equal to 7.7%. The trained model was also applied to unseen data from two subjects with transtibial amputation, producing physiologically consistent vGRF profiles. The system also promptly detected gait events, identifying heel strike and toe off with median delays of 0.01 s and 0.002 s, respectively. These results support the potential of the system for gait parameter estimation in prosthetic applications.


  • A Unilateral Active Knee Exoskeleton to Assist Individuals With Hemiparesis—A Pilot Study

    by Andrea Pergolini, Clara Beatriz Sanz-Morère, Chiara Livolsi, Matteo Fantozzi, Filippo Dell’aGnello, Tommaso Ciapetti, Alessandro Maselli, Andrea Baldoni, Emilio Trigili, Simona Crea, et al.

    Most individuals who experience a stroke exhibit several sensorimotor impairments that limit their independence in everyday activities. Hemiparetic gait is frequently characterized by reduced knee flexion in swing due to knee stiffness or muscle weakness and knee hyperextension or knee buckling in the stance phase. Recently, unilateral-powered orthoses have been designed to overcome the limitations of the passive knee-ankle-foot orthoses. This study presents a unilateral Active Knee Orthosis Exoskeleton, AKO-$\beta$, endowed with a series elastic actuator and designed to assist the knee in flexion and extension movements. The paper describes the system mechatronic design and its characterization on the bench, the control system, and pilot experiments with three post-stroke participants. The device has a weight of 1.78 kg on the user's leg, with a lateral encumbrance of 76 mm. The pilot experiments aimed to verify the effects of the exoskeleton assistance in hemiparetic gait patterns. When walking with the device, participants on average increased the knee flexion on the paretic side by 18.70 deg (+44.9%) during swing and decreased knee hyperextension in stance by 4.50 deg, compared to walking without it. Overall, when walking with the exoskeleton, subjects showed improved Gait Variable Score of the paretic knee profile by 37.5% compared to walking without it. The temporal and spatial gait symmetry indexes did not show clear changes, although an improvement in symmetry was observed in two of the three participants. These preliminary results suggest the potential benefits of the unilateral Active Knee Orthosis exoskeleton to enhance and restore mobility in individuals with hemiparetic gait.


  • Enhancing Motor Synchrony in Rhythmic Dyadic Tasks Through Portable Elbow Exoskeletons

    by Emanuele Peperoni, Stefano Laszlo Capitani, Lorenzo Grazi, Michele Francesco Penna, Lorenzo Amato, Filippo Dell'Agnello, Andrea Baldoni, Domenico Formica, Marc Leman, Nicola Vitiello, et al.

    Synchrony is a cornerstone for the successful physical interaction between humans while cooperating or competing towards a goal and is achieved by correct and smooth information exchange between subjects. Recently, Human-Robot-Human (HRH) interaction arose as an emerging paradigm for improving motor control in collaborative and dyadic motor tasks. Among the robotic solutions explored for agent coupling, exoskeletons are powerful tools for exerting torque and force feedback at the joint level. In this work, two identical torque-controlled elbow exoskeletons were used in dyadic interaction, to provide haptic feedback and improve synchrony between two individuals performing a tapping task. Each exoskeleton is lightweight and compact, weighing 0.8 kg on the arm. Bench tests to verify the performance of closed-loop torque control showed a residual torque below 0.2 Nm when the reference torque was set to zero, and a bandwidth higher than 6 Hz, thus achieving adequate performance for applications in HRH scenarios. In human subjects’ experiments, the root-mean-squared error between the two users’ joint trajectories was 50% lower when users received haptic feedback compared to the condition without feedback; the relative phase error was lower than 60%. The results of this study suggest that exoskeletons can enhance synchrony in HRH interactions, being potentially useful in rehabilitation training, collaborative industrial tasks or sport and music learning.


  • Open Access

    An Underactuated Active Transfemoral Prosthesis With Series Elastic Actuators Enables Multiple Locomotion Tasks

    by Ilaria Fagioli, Francesco Lanotte, Tommaso Fiumalbi, Andrea Baldoni, Alessandro Mazzarini, Filippo Dell'AGnello, Huseyin Eken, Vito Papapicco, Tommaso Ciapetti, Alessandro Maselli, et al.

    Robotic lower-limb prostheses have the power to revolutionize mobility by enhancing gait efficiency and facilitating movement. While several design approaches have been explored to create lightweight and energy-efficient devices, the potential of underactuation remains largely untapped in lower-limb prosthetics. Taking inspiration from the natural harmony of walking, we have developed an innovative active transfemoral prosthesis. By incorporating underactuation, our design uses a single power actuator placed near the knee joint and connected to a differential mechanism to drive both the knee and ankle joints. We conducted comprehensive benchtop tests and evaluated the prosthesis with three individuals who have above-knee amputations, assessing its performance in walking, stair climbing, and transitions between sitting and standing. Our evaluation focused on gathering position and torque data recorded from sensors integrated into the prosthesis and comparing these measurements to biomechanical data of able-bodied locomotion. Our findings highlight the promise of underactuation in advancing lower-limb prosthetics and demonstrate the feasibility of our kneeankle underactuated design in various tasks, showcasing its ability to replicate natural movement


  • Open Access

    Soft Transfemoral Prosthetic Socket With Sensing and Augmenting Feedback: A Case Study

    by Linda Paternò, Mariangela Filosa, Eugenio Anselmino, Alessio Cecere, Filippo Dell’aGnello, Emanuele Gruppioni, Alberto Mazzoni, Silvestro Micera, Calogero Oddo, Arianna Menciassi

    In lower limb prostheses, the physical interface constituted by the socket is a crucial component for the device success. This work proposes a new design based on a rigid frame integrated into a silicone structure which allows for a more comfortable biomechanical coupling with the residual limb and facilitates the integration of smart technologies. This paves the way for new possibilities for prosthetic bidirectional interfaces or user health monitoring. Thus, four surface EMG sensors, three vibrotactile units, and nine temperature and humidity sensors have been integrated into the socket. These components enable the users motor intention decoding, provide augmenting feedback, and measure the residual limb thermal condition when wearing the prosthesis. The new socket was tested on a partecipant with a transfemoral amputation. The sEMG signals were registered during five different tasks in a circuit training and the classification median accuracy of an intention decoding algorithm was found to always be higher than 73%. The user’s perception of vibrotactile feedback was assessed through a psychophysical experiment and revealed vibrations from singularly activated units were the best perceived. Questionnaire results confirmed a high satisfaction level. However, tests on temperature and humidity suggest more efforts are still required in terms of skin perspiration.


  • Open Access

    A Self-Aligning Upper-Limb Exoskeleton Preserving Natural Shoulder Movements: Kinematic Compatibility Analysis

    by Jun Pan, Davide Astarita, Andrea Baldoni, Filippo Dell’aGnello, Simona Crea, Nicola Vitiello, Emilio Trigili

    NESM-γ is an upper-limb exoskeleton to train motor functions of post-stroke patients. Based on the kinesiology of the upper limb, the NESM-γ includes a four degrees-of-freedom (DOF) active kinematic chain for the shoulder and elbow, along with a passive chain for self-aligning robotic joint axes with the glenohumeral (GH) joint’s center of rotation. The passive chain accounts for scapulohumeral rhythm and trunk rotations. To assess self-aligning performance, we analyzed the kinematic and electromyographic data of the shoulder in eight healthy subjects performing reaching tasks under three experimental conditions: moving without the exoskeleton ( baseline ), moving while wearing the exoskeleton with the passive DOFs properly functioning, i.e., unlocked ( human-in-the-loop(HIL)-unlocked ), and with the passive DOFs locked ( HIL-locked ). Comparison of baseline and HIL-unlocked conditions showed nearly unchanged anatomical movement patterns, with a root-mean-square error of shoulder angle lower than 5 deg and median deviations of the GH center of rotation below 20 mm. Peak muscle activations showed no significant differences. In contrast, the HIL-locked condition deviated significantly from the baseline , as observed by the trunk and GH trajectory deviations up to 50 mm, accompanied by increased peak muscle activations in the Deltoid and Upper Trapezius muscles. These findings highlight the need for kinematic solutions in shoulder exoskeletons that can accommodate the movements of the entire shoulder complex and trunk to achieve kinematic compatibility.


  • Open Access

    Uneven Terrain Recognition Using Neuromorphic Haptic Feedback

    by Sahana Prasanna, Jessica D’abbraccio, Mariangela Filosa, Davide Ferraro, Ilaria Cesini, Giacomo Spigler, Andrea Aliperta, Filippo Dell’agnello, Angelo Davalli, Emanuele Gruppioni, et al.

    Recent years have witnessed relevant advancements in the quality of life of persons with lower limb amputations thanks to the technological developments in prosthetics. However, prostheses that provide information about the foot–ground interaction, and in particular about terrain irregularities, are still missing on the market. The lack of tactile feedback from the foot sole might lead subjects to step on uneven terrains, causing an increase in the risk of falling. To address this issue, a biomimetic vibrotactile feedback system that conveys information about gait and terrain features sensed by a dedicated insole has been assessed with intact subjects. After having shortly experienced both even and uneven terrains, the recruited subjects discriminated them with an accuracy of 87.5%, solely relying on the replay of the vibrotactile feedback. With the objective of exploring the human decoding mechanism of the feedback startegy, a KNN classifier was trained to recognize the uneven terrains. The outcome suggested that the subjects achieved such performance with a temporal dynamics of 45 ms. This work is a leap forward to assist lower-limb amputees to appreciate the floor conditions while walking, adapt their gait and promote a more confident use of their artificial limb.


  • Open Access

    Self-Aligning Finger Exoskeleton for the Mobilization of the Metacarpophalangeal Joint

    by Emanuele Peperoni, Stefano Laszlo Capitani, Tommaso Fiumalbi, Eugenio Capotorti, Andrea Baldoni, Filippo Dell'AGnello, Ilaria Creatini, Elisa Taglione, Nicola Vitiello, Emilio Trigili, et al.

    In the context of hand and finger rehabilitation, kinematic compatibility is key for the acceptability and clinical exploitation of robotic devices. Different kinematic chain solutions have been proposed in the state of the art, with different trade-offs between characteristics of kinematic compatibility, adaptability to different anthropometries, and the ability to compute relevant clinical information. This study presents the design of a novel kinematic chain for the mobilization of the metacarpophalangeal (MCP) joint of the long fingers and a mathematical model for the real-time computation of the joint angle and transferred torque. The proposed mechanism can self-align with the human joint without hindering force transfer or inducing parasitic torque. The chain has been designed for integration into an exoskeletal device aimed at rehabilitating traumatic-hand patients. The exoskeleton actuation unit has a series-elastic architecture for compliant human-robot interaction and has been assembled and preliminarily tested in experiments with eight human subjects. Performance has been investigated in terms of (i) accuracy of the MCP joint angle estimation through comparison with a video-based motion tracking system, (ii) residual MCP torque when the exoskeleton is controlled to provide null output impedance and (iii) torque-tracking performance. Results showed a root-mean-square error (RMSE) below 5 degrees in the estimated MCP angle. The estimated residual MCP torque resulted below 7 mNm. Torque tracking performance shows an RMSE lower than 8 mNm in following sinusoidal reference profiles. The results encourage further investigations of the device in a clinical scenario.


  • NESM-γ: An Upper-Limb Exoskeleton With Compliant Actuators for Clinical Deployment

    by Jun Pan, Davide Astarita, Andrea Baldoni, Filippo Dell'Agnello, Simona Crea, Nicola Vitiello, Emilio Trigili

    This letter describes the design and characterization of an upper-limb exoskeleton for post-stroke rehabilitation. The platform interacts with the shoulder and elbow of the user through four active joints, driven by series elastic actuators (SEAs) with custom springs to achieve compactness and ease of maintenance. The exoskeleton adopts a passive kinematic chain for aligning the user's and robot joints’ rotation axes, and a quick flipping mechanism to enable dual-side use. The pole-placement method based on the dynamic model of the SEA was used to design the low-level controller, to guarantee torque control precision and stability. The joint load due to the robot's gravity is counteracted by using a feed-forward gravity compensation algorithm. Experimental characterization demonstrates the torque control bandwidth up to 10 Hz and highly transparent behavior of the joints (namely, close to null parasitic impedance) at least up to 2 Hz, showing suitability for rehabilitation purposes.


  • Open Access

    A Multimodal Sensory Apparatus for Robotic Prosthetic Feet Combining Optoelectronic Pressure Transducers and IMU

    by Tommaso Fiumalbi, Elena Martini, Vito Papapicco, Filippo Dell’agnello, Alessandro Mazzarini, Andrea Baldoni, Emanuele Gruppioni, Simona Crea, Nicola Vitiello

    Timely and reliable identification of control phases is functional to the control of a powered robotic lower-limb prosthesis. This study presents a commercial energy-store-and-release foot prosthesis instrumented with a multimodal sensory system comprising optoelectronic pressure sensors (PS) and IMU. The performance was verified with eight healthy participants, comparing signals processed by two different algorithms, based on PS and IMU, respectively, for real-time detection of heel strike (HS) and toe-off (TO) events and an estimate of relevant biomechanical variables such as vertical ground reaction force (vGRF) and center of pressure along the sagittal axis (CoPy). The performance of both algorithms was benchmarked against a force platform and a marker-based stereophotogrammetric motion capture system. HS and TO were estimated with a time error lower than 0.100 s for both the algorithms, sufficient for the control of a lower-limb robotic prosthesis. Finally, the CoPy computed from the PS showed a Pearson correlation coefficient of 0.97 (0.02) with the same variable computed through the force platform.