Philipp Schlumpberger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Philipp Schlumpberger has a total of 2 co-authors. Here are the top co-authors by number of shared publications:
- Christine A. Stübner
Leibniz Institute for Food Systems Biology at the Technical University of Munich (Leibniz-LSB@TUM), Freising, Germany
1 shared publication - Martin Steinhaus
Leibniz Institute for Food Systems Biology at the Technical University of Munich (Leibniz-LSB@TUM), Lise-Meitner-Straße 34, 85354 Freising, Germany
1 shared publication
Latest Publications
- Open Access
- 4 July 2022
- Published by Springer Nature in European Food Research and Technology
- Vol. 248 (10) , 2591-2602
Development and evaluation of an automated solvent-assisted flavour evaporation (aSAFE)
Artefact-avoiding isolation of the volatiles from foods is a crucial step before analysis of odour-active compounds by gas chromatography (GC). In the past 20 years, solvent extraction followed by solvent-assisted flavour evaporation (SAFE) has become the standard approach, particularly prior to GC–olfactometry. The manual valve of the SAFE equipment, however, leads to suboptimal yields and the risk of a contamination of the volatile isolate with non-volatiles. We thus developed an automated SAFE (aSAFE) approach by replacing the manual valve with an electronically controlled pneumatic valve. The aSAFE provides clearly higher yields than the manual SAFE (mSAFE), notably from extracts high in lipids and for odorants with comparably high boiling points. Additionally, aSAFE substantially reduces the risk of non-volatiles being transferred to the volatile isolate. Full automatisation is possible by combining the aSAFE approach with an automated liquid nitrogen refill system as well as an endpoint recognition and shut-off system.
- 4 July 2022
- Published by Springer Nature in European Food Research and Technology
- Vol. 248 (10) , 2591-2602
Open AccessDevelopment and evaluation of an automated solvent-assisted flavour evaporation (aSAFE)
Artefact-avoiding isolation of the volatiles from foods is a crucial step before analysis of odour-active compounds by gas chromatography (GC). In the past 20 years, solvent extraction followed by solvent-assisted flavour evaporation (SAFE) has become the standard approach, particularly prior to GC–olfactometry. The manual valve of the SAFE equipment, however, leads to suboptimal yields and the risk of a contamination of the volatile isolate with non-volatiles. We thus developed an automated SAFE (aSAFE) approach by replacing the manual valve with an electronically controlled pneumatic valve. The aSAFE provides clearly higher yields than the manual SAFE (mSAFE), notably from extracts high in lipids and for odorants with comparably high boiling points. Additionally, aSAFE substantially reduces the risk of non-volatiles being transferred to the volatile isolate. Full automatisation is possible by combining the aSAFE approach with an automated liquid nitrogen refill system as well as an endpoint recognition and shut-off system.