Artur Latorre-Musoll
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Artur Latorre-Musoll has a total of 23 co-authors. Here are the top co-authors by number of shared publications:
- Josep Sempau
Universitat Politècnica de Catalunya, Barcelona, Spain; Centro de Investigación Biomédica en Red en Bioingeniería, Biomateriales y Nanomedicina (CIBER-BBN), Madrid, Spain
4 shared publications - Gabriela Antelo
Radiation Oncology Department, Hospital Clinic of Barcelona, 08036 Barcelona, Spain
2 shared publications - Meritxell Mollà
Faculty of Medicine, University of Barcelona, 08007 Barcelona, Spain
2 shared publications Núria Jornet
Servei de Radiofisica i Radioproteccio, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
2 shared publications- Núria Jornet
Servei de Radiofisica i Radioproteccio, Hospital de la Santa Creu i Sant Pau, Barcelona, Spain
2 shared publications Sergi Serrano-Rueda
Department of Radiation Oncology, Hospital Clínic, Barcelona, Spain
2 shared publications
Latest Publications
- 27 April 2026
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 126 (2) , 308-317
One Year After a Cyberattack: Lessons Learned and Dosimetric Analysis of Contingency Radiotherapy Plans
- 27 April 2026
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 126 (2) , 308-317
One Year After a Cyberattack: Lessons Learned and Dosimetric Analysis of Contingency Radiotherapy Plans
- 23 October 2025
- Published by Elsevier in Physica Medica
- Vol. 139, 105206
On the robustness of the Transit-Guided Radiation Therapy technique against variations in linac operating conditions
- 23 October 2025
- Published by Elsevier in Physica Medica
- Vol. 139, 105206
On the robustness of the Transit-Guided Radiation Therapy technique against variations in linac operating conditions
- 11 October 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 201, 110580
Transit-guided radiation therapy: a novel patient monitoring approach
- 11 October 2024
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 201, 110580
Transit-guided radiation therapy: a novel patient monitoring approach
- 8 August 2023
- Published by Elsevier in Physica Medica
- Vol. 112, 102660
On the beam hardening correction of the Transit-Guided Radiation Therapy attenuation model
- 8 August 2023
- Published by Elsevier in Physica Medica
- Vol. 112, 102660
On the beam hardening correction of the Transit-Guided Radiation Therapy attenuation model
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S2033-S2034
PO-2261 On the implementation of a clinical workflow for the Transit-Guided Radiation Therapy technique
- 24 July 2023
- Published by Elsevier in Radiotherapy and Oncology
- Vol. 182, S2033-S2034
PO-2261 On the implementation of a clinical workflow for the Transit-Guided Radiation Therapy technique
- 29 July 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (15) , 155022
Transit-guided radiation therapy: proof of concept of an on-line technique for correcting position errors using transit portal images
Objective. Transit in vivo dosimetry methods monitor that the dose distribution is delivered as planned. However, they have a limited ability to identify and to quantify the cause of a given disagreement, especially those caused by position errors. This paper describes a proof of concept of a simple in vivo technique to infer a position error from a transit portal image (TPI). Approach. For a given treatment field, the impact of a position error is modeled as a perturbation of the corresponding reference (unperturbed) TPI. The perturbation model determines the patient translation, described by a shift vector, by comparing a given in vivo TPI to the corresponding reference TPI. Patient rotations can also be determined by applying this formalism to independent regions of interest over the patient. Eight treatment plans have been delivered to an anthropomorphic phantom under a large set of couch shifts (Main results. The root mean squared error (RMSE) between the determined and the true shift magnitudes was 1.0/2.4/4.9 mm for true shifts ranging between 0–5/5–10/10–15 mm, respectively. The angular accuracy of the determined shift directions was 12° ± 14°. The RMSE between the determined and the true rotations was 0.5°. The TGRT technique decoupled translations and rotations satisfactorily. In 96% of the cases, the TGRT technique decreased the existing position error. The detection threshold of the TGRT technique was around 1 mm and it was nearly independent of the tumor site, delivery technique, beam energy or patient thickness. Significance. TGRT is a promising technique that not only provides reliable determinations of the position errors without increasing the required equipment, acquisition time or patient dose, but it also adds on-line correction capabilities to existing methods currently using TPIs.
- 29 July 2022
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 67 (15) , 155022
Transit-guided radiation therapy: proof of concept of an on-line technique for correcting position errors using transit portal images
Objective. Transit in vivo dosimetry methods monitor that the dose distribution is delivered as planned. However, they have a limited ability to identify and to quantify the cause of a given disagreement, especially those caused by position errors. This paper describes a proof of concept of a simple in vivo technique to infer a position error from a transit portal image (TPI). Approach. For a given treatment field, the impact of a position error is modeled as a perturbation of the corresponding reference (unperturbed) TPI. The perturbation model determines the patient translation, described by a shift vector, by comparing a given in vivo TPI to the corresponding reference TPI. Patient rotations can also be determined by applying this formalism to independent regions of interest over the patient. Eight treatment plans have been delivered to an anthropomorphic phantom under a large set of couch shifts (Main results. The root mean squared error (RMSE) between the determined and the true shift magnitudes was 1.0/2.4/4.9 mm for true shifts ranging between 0–5/5–10/10–15 mm, respectively. The angular accuracy of the determined shift directions was 12° ± 14°. The RMSE between the determined and the true rotations was 0.5°. The TGRT technique decoupled translations and rotations satisfactorily. In 96% of the cases, the TGRT technique decreased the existing position error. The detection threshold of the TGRT technique was around 1 mm and it was nearly independent of the tumor site, delivery technique, beam energy or patient thickness. Significance. TGRT is a promising technique that not only provides reliable determinations of the position errors without increasing the required equipment, acquisition time or patient dose, but it also adds on-line correction capabilities to existing methods currently using TPIs.