Annie C. J. Russell
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Annie C. J. Russell has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Christopher E. Valdivia
University of Ottawa,SUNLAB,Ottawa,ON,Canada
3 shared publications - Karin Hinzer
University of Ottawa
3 shared publications Joan E. Haysom
SUNLAB, Centre for Research in Photonics, School of Electrical Engineering and Computer Science, University of Ottawa, Ottawa, ON, Canada
2 shared publicationsCedric Bohemier
SUNLAB, Centre for Research in Photonics, School of Electrical Engineering and Computer Science, University of Ottawa, Ottawa, ON, Canada
1 shared publication- Erin M. Tonita
Sunlab, University of Ottawa, Ottawa, ON, Canada
1 shared publication
Latest Publications
- 11 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Optimal Row Spacing for Monofacial and Bifacial Fixed-Tilt and Tracked Photovoltaic Systems Up to 75°N
The inter-row spacing of photovoltaic arrays is an influential design parameter that impacts both a system' energy yield and land-use. Optimization of PV arrays within a constrained area is required, and rule-of-thumb approaches to row spacing which focus solely on eliminating shading for conventional monofacial fixed-tilt PV arrays may not be appropriate. Here, we quantify how variations in ground coverage ratio (GCR) between 0-1 for fixed-tilt and horizontal single-axis tracked (HSAT) monofacial and bifacial PV arrays affect the amount of energy yield lost due to inter-row shading between latitudes of 17-75°N. We additionally optimize the tilt of fixed-tilt systems for these latitudes and GCRs. We demonstrate that fixed-tilt and HSAT arrays located >55°N require similar land-use, while for low-to-moderate latitudes marginal changes in GCR result in significant changes to shading loss for HSAT arrays compared to fixed-tilt arrays. For example, a shift in GCR from 0.3 to 0.4 in Tuxtla Gutierrez at 17°N increases the percent of module energy yield lost to inter-row shading effects by 0.5% abs. for a fixed-tilt array compared to 2.4% abs. for a HSAT array. We additionally calculate that bifacial PV arrays require GCRs lower by 0.03 on average than monofacial arrays to achieve the same shading loss, regardless of tracking type.
- 11 June 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1
Optimal Row Spacing for Monofacial and Bifacial Fixed-Tilt and Tracked Photovoltaic Systems Up to 75°N
The inter-row spacing of photovoltaic arrays is an influential design parameter that impacts both a system' energy yield and land-use. Optimization of PV arrays within a constrained area is required, and rule-of-thumb approaches to row spacing which focus solely on eliminating shading for conventional monofacial fixed-tilt PV arrays may not be appropriate. Here, we quantify how variations in ground coverage ratio (GCR) between 0-1 for fixed-tilt and horizontal single-axis tracked (HSAT) monofacial and bifacial PV arrays affect the amount of energy yield lost due to inter-row shading between latitudes of 17-75°N. We additionally optimize the tilt of fixed-tilt systems for these latitudes and GCRs. We demonstrate that fixed-tilt and HSAT arrays located >55°N require similar land-use, while for low-to-moderate latitudes marginal changes in GCR result in significant changes to shading loss for HSAT arrays compared to fixed-tilt arrays. For example, a shift in GCR from 0.3 to 0.4 in Tuxtla Gutierrez at 17°N increases the percent of module energy yield lost to inter-row shading effects by 0.5% abs. for a fixed-tilt array compared to 2.4% abs. for a HSAT array. We additionally calculate that bifacial PV arrays require GCRs lower by 0.03 on average than monofacial arrays to achieve the same shading loss, regardless of tracking type.
- Open Access
- 4 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 12 (6) , 1576-1585
DUET: A Novel Energy Yield Model With 3-D Shading for Bifacial Photovoltaic Systems
Bifacial photovoltaic (PV) performance models strive to accurately quantify rear-incident irradiance. While ray tracing models are optically rigorous, they require significant computational resources; faster view factor (VF) models are widely adopted but require user-defined loss factors to approximate rear shading and irradiance nonuniformity, introducing uncertainty in energy yield predictions. This article describes DUET—a bifacial PV performance model that calculates optical and electrical performance based on a physically representative array geometry. DUET's novel shading algorithm pairs a 3-D VF model with deterministic ray-object intersections to capture 2-D shade-inclusive irradiance profiles while minimizing computational cost. Series and parallel combination of current–voltage curves capture irradiance nonuniformity throughout the module and array. This article provides validation against open-access system measurements from a test site in Roskilde, Denmark, and comparison to other software tested there [1]. DUET's modeled bifacial energy yield agrees with measured data within −1.56% for fixed-tilt and −0.65% for horizontal single-axis tracked (HSAT) systems. Mean absolute error (MAE) in hourly bifacial power is 14.2–15.0 mW/Wp for fixed-tilt and 17.3–18.3 mW/Wp for HSAT, depending on the module temperature model applied. Comparing modeled and measured rear irradiance of two rear-facing pyranometers, DUET's MAE values of 2.8 W/m$^{2}$ for fixed-tilt and 3.7 W/m$^{2}$ for HSAT are among the lowest errors reported for other software tested at this site. DUET provides computationally efficient bifacial performance modeling with geographic, temporal, and structural specificity to determine loss factors for use in other performance models or to be used directly in system design optimization.- 4 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Photovoltaics
- Vol. 12 (6) , 1576-1585
Open AccessDUET: A Novel Energy Yield Model With 3-D Shading for Bifacial Photovoltaic Systems
Bifacial photovoltaic (PV) performance models strive to accurately quantify rear-incident irradiance. While ray tracing models are optically rigorous, they require significant computational resources; faster view factor (VF) models are widely adopted but require user-defined loss factors to approximate rear shading and irradiance nonuniformity, introducing uncertainty in energy yield predictions. This article describes DUET—a bifacial PV performance model that calculates optical and electrical performance based on a physically representative array geometry. DUET's novel shading algorithm pairs a 3-D VF model with deterministic ray-object intersections to capture 2-D shade-inclusive irradiance profiles while minimizing computational cost. Series and parallel combination of current–voltage curves capture irradiance nonuniformity throughout the module and array. This article provides validation against open-access system measurements from a test site in Roskilde, Denmark, and comparison to other software tested there [1]. DUET's modeled bifacial energy yield agrees with measured data within −1.56% for fixed-tilt and −0.65% for horizontal single-axis tracked (HSAT) systems. Mean absolute error (MAE) in hourly bifacial power is 14.2–15.0 mW/Wp for fixed-tilt and 17.3–18.3 mW/Wp for HSAT, depending on the module temperature model applied. Comparing modeled and measured rear irradiance of two rear-facing pyranometers, DUET's MAE values of 2.8 W/m$^{2}$ for fixed-tilt and 3.7 W/m$^{2}$ for HSAT are among the lowest errors reported for other software tested at this site. DUET provides computationally efficient bifacial performance modeling with geographic, temporal, and structural specificity to determine loss factors for use in other performance models or to be used directly in system design optimization. - 5 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 193, 1-4
Impact of Snow Depth on Single-Axis Tracked Bifacial Photovoltaic System Performance
Photovoltaic (PV) capacity is rapidly expanding in mid-to-high latitude jurisdictions due to drastic decreases in PV system cost and global decarbonization efforts. However, uncertainty around performance impacts of latitude-specific conditions, such as ground-accumulated snow, contribute to investment risk. In this work, we employed DUET, our custom bifacial PV modelling tool, to study variable ground clearance resulting from snow accumulation. We model the impact of snow depth on a module in four generic, 2-in-portait single-axis tracked (SAT) systems with baseline ground clearances ranging from 1.6-2.8 m. Over the snowy season in Ottawa, Ontario $(\boldsymbol{45}^{\circ}\mathbf{N})$ and Cambridge Bay, Nunavut $(\boldsymbol{69}^{\circ}\mathbf{N})$ , Canada, rear insolation and energy yield decrease by 3.4-9.6% and 0.36-0.69%, respectively - comparable to annual structure shading and electrical mismatch loss factors. The average daily energy yield loss in both locations is 0.034 % per centimeter of accumulated snow. When hourly energy yield loss throughout the snowy season is binned by hour of day, hourly averages peak at 1.2-1.4% loss, suggesting implications for real-time and short-term forecasting.- 5 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 193, 1-4
Impact of Snow Depth on Single-Axis Tracked Bifacial Photovoltaic System Performance
Photovoltaic (PV) capacity is rapidly expanding in mid-to-high latitude jurisdictions due to drastic decreases in PV system cost and global decarbonization efforts. However, uncertainty around performance impacts of latitude-specific conditions, such as ground-accumulated snow, contribute to investment risk. In this work, we employed DUET, our custom bifacial PV modelling tool, to study variable ground clearance resulting from snow accumulation. We model the impact of snow depth on a module in four generic, 2-in-portait single-axis tracked (SAT) systems with baseline ground clearances ranging from 1.6-2.8 m. Over the snowy season in Ottawa, Ontario $(\boldsymbol{45}^{\circ}\mathbf{N})$ and Cambridge Bay, Nunavut $(\boldsymbol{69}^{\circ}\mathbf{N})$ , Canada, rear insolation and energy yield decrease by 3.4-9.6% and 0.36-0.69%, respectively - comparable to annual structure shading and electrical mismatch loss factors. The average daily energy yield loss in both locations is 0.034 % per centimeter of accumulated snow. When hourly energy yield loss throughout the snowy season is binned by hour of day, hourly averages peak at 1.2-1.4% loss, suggesting implications for real-time and short-term forecasting.