Jiaming Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Jiaming Wu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Feng Wang
State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou 310027, China
6 shared publications Bing Xu
State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou, Zhejiang, China
5 shared publicationsHaoxiang Zhang
2 shared publications- Shunyuan Xu
Department of Naval Architecture and Ocean Engineering, South China University of Technology, Guangzhou, China
2 shared publications - Xianyuan Yang
Department of Naval Architecture and Ocean Engineering, South China University of Technology, Guangzhou 510640, China
2 shared publications Yihan Qiao
State Key Laboratory of Fluid Power and Mechatronic Systems, School of Mechanical Engineering, Zhejiang University, Hangzhou, Zhejiang, China
2 shared publications
Latest Publications
- 13 July 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering
Improving energy efficiency of electric wheel loader working function: An electro-hydraulic hybrid solution with energy optimization
The load-sensing (LS) system is one of the effective ways to improve energy efficiency of electric wheel loader working function. However, the LS system still has the limitations including throttling loss of control valve, low-efficiency operating points of the electric motor-pump and large installed motor power. Therefore, an electro-hydraulic hybrid variable speed pump drive system (EH-VSPD) is proposed to improve energy efficiency and downsize electric drive system. The system employs a variable-speed pump (VSP) unit to control actuator velocity, avoiding the throttling losses. A high-pressure accumulator in parallel configuration assists the VSP unit under high load condition, to reduce system installed power. The electric VSP unit supplies the average power demand, while the accumulator responds to peak load requirements. An energy management strategy based on the dynamic programming is developed to manage the power distribution of two energy sources. Simulation results show that EH-VSPD system’s energy efficiency is improved from 45.6% to 61.1% and the installed motor power reduces by 44.9% compared to LS system (from 147 to 81 kW). The proposed system achieves a significant improvement in energy efficiency meanwhile downsizing the working function. The performance with different accumulator parameters and installed motor power is also compared to provide a reference for different requirement of system design and loading cycle.
- 13 July 2026
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering
Improving energy efficiency of electric wheel loader working function: An electro-hydraulic hybrid solution with energy optimization
The load-sensing (LS) system is one of the effective ways to improve energy efficiency of electric wheel loader working function. However, the LS system still has the limitations including throttling loss of control valve, low-efficiency operating points of the electric motor-pump and large installed motor power. Therefore, an electro-hydraulic hybrid variable speed pump drive system (EH-VSPD) is proposed to improve energy efficiency and downsize electric drive system. The system employs a variable-speed pump (VSP) unit to control actuator velocity, avoiding the throttling losses. A high-pressure accumulator in parallel configuration assists the VSP unit under high load condition, to reduce system installed power. The electric VSP unit supplies the average power demand, while the accumulator responds to peak load requirements. An energy management strategy based on the dynamic programming is developed to manage the power distribution of two energy sources. Simulation results show that EH-VSPD system’s energy efficiency is improved from 45.6% to 61.1% and the installed motor power reduces by 44.9% compared to LS system (from 147 to 81 kW). The proposed system achieves a significant improvement in energy efficiency meanwhile downsizing the working function. The performance with different accumulator parameters and installed motor power is also compared to provide a reference for different requirement of system design and loading cycle.
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 73 (12) , 18250-18265
An Independent Electro-Hydraulic Variable Speed Drive to Improve Energy Efficiency of Electric Wheel Loader Working System
Powertrain electrification is an effective solution to reducing emissions of construction machinery. However, working hydraulic system of existing electric wheel loaders are centralized load-sensing (LS) system. The LS system suffers from low energy efficiency because of valve throttling losses. Therefore, an independent electro-hydraulic variable speed drive (VSD) with separate layout, normal pump speed and closed circuit is proposed to increase the efficiency of working hydraulic system and electric wheel loader. The VSD is powered by a variable-speed electric motor and a fixed pump without throttle control valve, eliminating throttling losses. Besides, the separate VSD utilizes commercially available electric motor and pump, interconnecting actuator via hydraulic pipelines. The system components are modeled in detail and the influence of pipeline is considered in simulation analysis. A mode-based control strategy for the proposed powertrain is developed. The simulation study is carried out to verify the feasibility of the proposed separate design and control strategy. The powertrain operation and energy comparison between proposed powertrain and baseline powertrain are conducted. Results demonstrate the efficiency of independent electrohydraulic variable speed drive improves from 36.9% to 70.6% compared to centralized LS system. Furthermore, the proposed powertrain reduces energy consumption by 32.3% compared with baseline powertrain
- 21 August 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Vehicular Technology
- Vol. 73 (12) , 18250-18265
An Independent Electro-Hydraulic Variable Speed Drive to Improve Energy Efficiency of Electric Wheel Loader Working System
Powertrain electrification is an effective solution to reducing emissions of construction machinery. However, working hydraulic system of existing electric wheel loaders are centralized load-sensing (LS) system. The LS system suffers from low energy efficiency because of valve throttling losses. Therefore, an independent electro-hydraulic variable speed drive (VSD) with separate layout, normal pump speed and closed circuit is proposed to increase the efficiency of working hydraulic system and electric wheel loader. The VSD is powered by a variable-speed electric motor and a fixed pump without throttle control valve, eliminating throttling losses. Besides, the separate VSD utilizes commercially available electric motor and pump, interconnecting actuator via hydraulic pipelines. The system components are modeled in detail and the influence of pipeline is considered in simulation analysis. A mode-based control strategy for the proposed powertrain is developed. The simulation study is carried out to verify the feasibility of the proposed separate design and control strategy. The powertrain operation and energy comparison between proposed powertrain and baseline powertrain are conducted. Results demonstrate the efficiency of independent electrohydraulic variable speed drive improves from 36.9% to 70.6% compared to centralized LS system. Furthermore, the proposed powertrain reduces energy consumption by 32.3% compared with baseline powertrain
- 15 February 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering
- Vol. 237 (7) , 1147-1160
A novel hydraulic load-sensing control solution to working functions of mobile machine
The hydraulic load-sensing system is a more efficient system solution than constant pressure system in mobile machine. However, the overall system efficiency for multiple actuators is still low since this centralized hydraulic control system only adapts to the highest load pressure. Therefore, in this article, a distributed hydraulic control system where each function is powered by a hydraulic free piston engine is proposed. Compared with centralized solution, it is more efficient since the power of hydraulic free piston engine is tailored to each function. By integrating small inertia linear engine and pump piston in one unit, the hydraulic free piston engine is an efficient and fast response hydraulic power source. Since the hydraulic free piston engine is essentially a digital hydraulic power source, a digital load-sensing control is proposed in this study. The system architecture, modeling, controller design and performance of the digital hydraulic load-sensing control system are presented. A test bench is developed to verify the system feasibility and performance.
- 15 February 2023
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part I: Journal of Systems and Control Engineering
- Vol. 237 (7) , 1147-1160
A novel hydraulic load-sensing control solution to working functions of mobile machine
The hydraulic load-sensing system is a more efficient system solution than constant pressure system in mobile machine. However, the overall system efficiency for multiple actuators is still low since this centralized hydraulic control system only adapts to the highest load pressure. Therefore, in this article, a distributed hydraulic control system where each function is powered by a hydraulic free piston engine is proposed. Compared with centralized solution, it is more efficient since the power of hydraulic free piston engine is tailored to each function. By integrating small inertia linear engine and pump piston in one unit, the hydraulic free piston engine is an efficient and fast response hydraulic power source. Since the hydraulic free piston engine is essentially a digital hydraulic power source, a digital load-sensing control is proposed in this study. The system architecture, modeling, controller design and performance of the digital hydraulic load-sensing control system are presented. A test bench is developed to verify the system feasibility and performance.
- 28 September 2022
- Published by Elsevier in Ocean Engineering
- Vol. 265, 112599
Study on dynamic response of underwater towed system in ship propeller wakes using a new hydrodynamic model
- 28 September 2022
- Published by Elsevier in Ocean Engineering
- Vol. 265, 112599
Study on dynamic response of underwater towed system in ship propeller wakes using a new hydrodynamic model
- 29 June 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering
- Vol. 237 (9) , 2344-2354
Characteristics study of electro-hydraulic load-sensing control system for mobile machines
The hydro-mechanical load-sensing control is an efficient system solution to working function of mobile machines since the system pressure always adapts to the highest load pressure. The main issue of this system is its instability problem caused by hydro-mechanical feedback control. Moreover the pressure margin between system and load pressure set by the load-sensing compensator is usually fixed and has less control flexibility. Therefore, an electro-hydraulic load-sensing control system occurs, where the load pressure is sensed by pressure transducer and load-sensing control is achieved electronically. It eliminates the hydro-mechanical feedback control loop and has more control flexibility. The previous studies mainly focus on the system function, controller design and system efficiency. However the quantitative analysis of system characteristics has not yet been studied. Therefore, in this paper a method is provided to investigate the influences of pump displacement dynamics and preset pressure margin on system control performance. A hydraulic load-sensing control test rig is developed. Results show a good agreement between simulation and test results. The pressure margin fluctuation is reduced by using a pump with faster displacement dynamics and a larger cut-off frequency of load velocity control is obtained with a larger preset pressure margin however this results in lower system efficiency.
- 29 June 2022
- Published by SAGE Publications in Proceedings of the Institution of Mechanical Engineers, Part D: Journal of Automobile Engineering
- Vol. 237 (9) , 2344-2354
Characteristics study of electro-hydraulic load-sensing control system for mobile machines
The hydro-mechanical load-sensing control is an efficient system solution to working function of mobile machines since the system pressure always adapts to the highest load pressure. The main issue of this system is its instability problem caused by hydro-mechanical feedback control. Moreover the pressure margin between system and load pressure set by the load-sensing compensator is usually fixed and has less control flexibility. Therefore, an electro-hydraulic load-sensing control system occurs, where the load pressure is sensed by pressure transducer and load-sensing control is achieved electronically. It eliminates the hydro-mechanical feedback control loop and has more control flexibility. The previous studies mainly focus on the system function, controller design and system efficiency. However the quantitative analysis of system characteristics has not yet been studied. Therefore, in this paper a method is provided to investigate the influences of pump displacement dynamics and preset pressure margin on system control performance. A hydraulic load-sensing control test rig is developed. Results show a good agreement between simulation and test results. The pressure margin fluctuation is reduced by using a pump with faster displacement dynamics and a larger cut-off frequency of load velocity control is obtained with a larger preset pressure margin however this results in lower system efficiency.
- 1 December 2021
- Published by Elsevier in Ocean Engineering
- Vol. 241, 110051
Trajectory tracking and hydrodynamics of a tethered underwater vehicle based on hybrid grid
- 1 December 2021
- Published by Elsevier in Ocean Engineering
- Vol. 241, 110051
Trajectory tracking and hydrodynamics of a tethered underwater vehicle based on hybrid grid