Scott Moroch
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Scott Moroch has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
- Timothy Koeth
University of Maryland, College Park, Maryland
3 shared publications - Ariana Michelle Shearin
Department of Materials Science and Engineering, University of Maryland, College Park, MD, United States of America
2 shared publications - Klaus Blaum
Max-Planck-Institut für Kernphysik, Heidelberg, Germany
2 shared publications - Anastasia Borschevsky
University of Groningen
1 shared publication Brian L. Beaudoin
Department of Materials Science and Engineering, University of Maryland
1 shared publication- Brian L. Beaudoin
Institute for Research in Electronics and Applied Physics, University of Maryland 2 , College Park, Maryland 20742
1 shared publication
Latest Publications
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
Optimization of a compact electron beam ion trap/source for the generation of low-Z highly charged ions.
The optimization of an electron beam ion trap/source (EBIT/S) for the generation of low-Z highly charged ions through several iterations of simulations is presented. Software packages Maxwell RZ and MICHELLE were used to compare the effects of electrode assembly materials and geometries on the relevant electric and magnetic fields for shaping the ionizing electron beam. COMSOL was used to examine trapped ion trajectories and inform production rates. The optimization of the electromagnetic fields and ionizing electron beam is achieved through computational simulation. The final design was constructed and characterized. This method of analysis before assembly allows ion source designs to be adapted for targeted purposes or to fit practical constraints. To compensate for the effects of new adaptations, dimensions and materials may be varied in these simulations until the desired fields and electron beam profile are recovered. The final assembled EBIT/S designed for the Cryogenic Ultrahigh vacuum Radioactive Ion Experiment (CURIE) at the University of Maryland, College Park, is compact, cryogen-free and generates multiply charged ions of low-Z neutrals. The CURIE EBIT/S and beamline has been used to generate, filter, and observe argon ions up to charge state q = 8.
- 1 July 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (7)
Optimization of a compact electron beam ion trap/source for the generation of low-Z highly charged ions.
The optimization of an electron beam ion trap/source (EBIT/S) for the generation of low-Z highly charged ions through several iterations of simulations is presented. Software packages Maxwell RZ and MICHELLE were used to compare the effects of electrode assembly materials and geometries on the relevant electric and magnetic fields for shaping the ionizing electron beam. COMSOL was used to examine trapped ion trajectories and inform production rates. The optimization of the electromagnetic fields and ionizing electron beam is achieved through computational simulation. The final design was constructed and characterized. This method of analysis before assembly allows ion source designs to be adapted for targeted purposes or to fit practical constraints. To compensate for the effects of new adaptations, dimensions and materials may be varied in these simulations until the desired fields and electron beam profile are recovered. The final assembled EBIT/S designed for the Cryogenic Ultrahigh vacuum Radioactive Ion Experiment (CURIE) at the University of Maryland, College Park, is compact, cryogen-free and generates multiply charged ions of low-Z neutrals. The CURIE EBIT/S and beamline has been used to generate, filter, and observe argon ions up to charge state q = 8.
- Open Access
- 21 July 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (3)
Half-life measurements of highly charged radioisotopes by nuclear recoil in a Penning trap
We present a unique method for measuring the half-life of highly charged radioisotopes by nondestructive nuclear recoil detection in a Penning ion trap. A specific emphasis is placed on Be 3 + 7 , which plays a crucial role in stellar evolution and the production of solar neutrinos. The determination of the half-life is necessary to constrain the free electron capture rate in the solar environment, but is difficult to measure by existing techniques. Simulations of the sympathetic cooling of the recoiled daughter nuclei ( Li 3 + 7 ) with the trapped cloud of Be 3 + 7 demonstrate a decay detection efficiency of 99.5 % . A statistical analysis of half-life measurements on ensembles containing hundreds of ions shows that a final statistical uncertainty of less than 5 % is achieved with only 500 measured decays. By coherent control of hyperfine populations in trapped ions, the fidelity of the technique we describe enables the direct measurement and manipulation of state-dependent decay branching ratios for the first time.
- 21 July 2025
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 7 (3)
Open AccessHalf-life measurements of highly charged radioisotopes by nuclear recoil in a Penning trap
We present a unique method for measuring the half-life of highly charged radioisotopes by nondestructive nuclear recoil detection in a Penning ion trap. A specific emphasis is placed on Be 3 + 7 , which plays a crucial role in stellar evolution and the production of solar neutrinos. The determination of the half-life is necessary to constrain the free electron capture rate in the solar environment, but is difficult to measure by existing techniques. Simulations of the sympathetic cooling of the recoiled daughter nuclei ( Li 3 + 7 ) with the trapped cloud of Be 3 + 7 demonstrate a decay detection efficiency of 99.5 % . A statistical analysis of half-life measurements on ensembles containing hundreds of ions shows that a final statistical uncertainty of less than 5 % is achieved with only 500 measured decays. By coherent control of hyperfine populations in trapped ions, the fidelity of the technique we describe enables the direct measurement and manipulation of state-dependent decay branching ratios for the first time.
- 19 July 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (3) , 033003
Electroweak Nuclear Properties from Single Molecular Ions in a Penning Trap
We present a novel technique to probe electroweak nuclear properties by measuring parity violation (PV) in single molecular ions in a Penning trap. The trap's strong magnetic field Zeeman shifts opposite-parity rotational and hyperfine molecular states into near degeneracy. The weak interaction-induced mixing between these degenerate states can be larger than in atoms by more than 12 orders of magnitude, thereby vastly amplifying PV effects. The single molecule sensitivity would be suitable for applications to nuclei across the nuclear chart, including rare and unstable nuclei.
- 19 July 2024
- Published by American Physical Society (APS) in Physical Review Letters
- Vol. 133 (3) , 033003
Electroweak Nuclear Properties from Single Molecular Ions in a Penning Trap
We present a novel technique to probe electroweak nuclear properties by measuring parity violation (PV) in single molecular ions in a Penning trap. The trap's strong magnetic field Zeeman shifts opposite-parity rotational and hyperfine molecular states into near degeneracy. The weak interaction-induced mixing between these degenerate states can be larger than in atoms by more than 12 orders of magnitude, thereby vastly amplifying PV effects. The single molecule sensitivity would be suitable for applications to nuclei across the nuclear chart, including rare and unstable nuclei.
- Open Access
- 1 August 2022
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 6 (8) , 085008
Space-charge effects in low-energy flat-beam transforms
Flat-beam transforms (FBTs) provide a technique for controlling the emittance partitioning between the beam’s two transverse dimensions. To date, nearly all FBT studies have been in regimes where the beam’s own space-charge effects can be ignored, such as in applications with high-brightness electron linacs where the transform occurs at high, relativistic, energies. Additionally, FBTs may provide a revolutionary path to high-power generation at high frequencies in vacuum electron devices where the beam emittance is currently becoming a limiting factor, which is the motivation for this paper. Electron beams in vacuum electron devices operate both at a much lower energy and a much higher current than in accelerators and the beam’s space-charge forces can no longer be ignored. Here we analyze the effects of space charge in FBTs and show there are both linear and nonlinear forces and effects. The linear effects can be compensated by retuning the FBT and by adding additional quadrupole elements. The nonlinear effects lead to an ultimate dilution of the lower recovered emittance and may lead to an eventual power limitation for high-frequency traveling-wave tubes and other vacuum electron devices.
- 1 August 2022
- Published by IOP Publishing in Journal of Physics Communications
- Vol. 6 (8) , 085008
Open AccessSpace-charge effects in low-energy flat-beam transforms
Flat-beam transforms (FBTs) provide a technique for controlling the emittance partitioning between the beam’s two transverse dimensions. To date, nearly all FBT studies have been in regimes where the beam’s own space-charge effects can be ignored, such as in applications with high-brightness electron linacs where the transform occurs at high, relativistic, energies. Additionally, FBTs may provide a revolutionary path to high-power generation at high frequencies in vacuum electron devices where the beam emittance is currently becoming a limiting factor, which is the motivation for this paper. Electron beams in vacuum electron devices operate both at a much lower energy and a much higher current than in accelerators and the beam’s space-charge forces can no longer be ignored. Here we analyze the effects of space charge in FBTs and show there are both linear and nonlinear forces and effects. The linear effects can be compensated by retuning the FBT and by adding additional quadrupole elements. The nonlinear effects lead to an ultimate dilution of the lower recovered emittance and may lead to an eventual power limitation for high-frequency traveling-wave tubes and other vacuum electron devices.