Guangming Jia
Guangming Jia has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Chuang Shen
School of Testing and Optoelectronic Engineering, Nanchang Hangkong University, Nanchang 330063, China
1 shared publication - Hao Lan
Pipechina Research Institute, Langfang 065000, China
1 shared publication - Jinyao Duan
School of Testing and Optoelectronic Engineering, Nanchang Hangkong University, Nanchang 330063, China
1 shared publication - Kai Song
Key Laboratory of Nondestructive Testing, Ministry of Education, Nanchang Hangkong University, Nanchang, China
1 shared publication - Kuan Fu
Pipechina Research Institute, Langfang 065000, China
1 shared publication - Pengchao Chen
PipeChina Institute of Science and Technology, Langfang 065000, China
1 shared publication
Latest Publications
- Open Access
A Decade Review of the Art of Inspection and Monitoring Technologies for Long-Distance Oil and Gas Pipelines in Permafrost Areas
Long-distance oil and gas pipelines buried in permafrost areas will inevitably encounter typical geological disasters, such as frost heave and thaw settlement and sliding, which easily cause pipeline displacement, bending, or deformation. When there are certain defects in the pipeline, additional complex, external stress will further lead to the failure of the pipeline or weld and can even lead to serious accidents such as pipeline leakage, pipe burst, or fracture. This paper introduces in detail the typical defects and risks of buried pipelines in permafrost areas and summarizes the in-line inspection technologies, off-line inspection technologies, and integrated monitoring systems for pipelines in the pipeline industry. Regarding pipelines in permafrost areas, in-line inspection methods may be employed. These include magnetic flux leakage, electromagnetic eddy current, ultrasonic, IMU, and electromagnetic acoustic transducer inspections. Off-line inspection is also one of the important means of inspecting a pipeline in a permafrost area. Indirect inspection is combined with verification by direct inspection to check and evaluate the integrity of the anticorrosive coating and the effectiveness of the cathodic protection for the pipeline. Meanwhile, considering the external environment of a pipeline in a permafrost area, a monitoring system should be developed and established. This paper discusses and projects the future development of related technologies, which provides reference for the construction and operation of pipelines in permafrost areas.
Open AccessA Decade Review of the Art of Inspection and Monitoring Technologies for Long-Distance Oil and Gas Pipelines in Permafrost Areas
Long-distance oil and gas pipelines buried in permafrost areas will inevitably encounter typical geological disasters, such as frost heave and thaw settlement and sliding, which easily cause pipeline displacement, bending, or deformation. When there are certain defects in the pipeline, additional complex, external stress will further lead to the failure of the pipeline or weld and can even lead to serious accidents such as pipeline leakage, pipe burst, or fracture. This paper introduces in detail the typical defects and risks of buried pipelines in permafrost areas and summarizes the in-line inspection technologies, off-line inspection technologies, and integrated monitoring systems for pipelines in the pipeline industry. Regarding pipelines in permafrost areas, in-line inspection methods may be employed. These include magnetic flux leakage, electromagnetic eddy current, ultrasonic, IMU, and electromagnetic acoustic transducer inspections. Off-line inspection is also one of the important means of inspecting a pipeline in a permafrost area. Indirect inspection is combined with verification by direct inspection to check and evaluate the integrity of the anticorrosive coating and the effectiveness of the cathodic protection for the pipeline. Meanwhile, considering the external environment of a pipeline in a permafrost area, a monitoring system should be developed and established. This paper discusses and projects the future development of related technologies, which provides reference for the construction and operation of pipelines in permafrost areas.
- Open Access
Application of Alternating Current Stress Measurement Method in the Stress Detection of Long-Distance Oil Pipelines
With the development of pipeline networks, many safety accidents were caused by pipeline stress concentration; it is of great significance to accurately monitor the pipeline stress state for maintaining pipeline safety. In this paper, based on alternating current stress measurement (ACSM) methods, a 3D simulation model of a pipeline electromagnetic field was established by ANSYS software. The distribution law of the pipeline magnetic field and eddy current field were analyzed, and the influence of size and structure parameters of the coil inside the probe were studied. The internal stress detection system of the pipeline was designed, and the static tensile stress measurement experiment was carried out. Simulation and test results showed that the excitation coil with a larger diameter-to-height ratio had a higher measurement sensitivity. The sensitivity of the probe decreased monotonically with the increase of the difference between inner diameter and outer diameter of the detection coil. It increased monotonically with the increase of the equivalent radius of the detection coil. The best measurement results were obtained when the detection coil was located at the center of the two legs of the U-magnetic core. The results showed that the system could identify the pipeline stress concentration area effectively after detection engineering.
Open AccessApplication of Alternating Current Stress Measurement Method in the Stress Detection of Long-Distance Oil Pipelines
With the development of pipeline networks, many safety accidents were caused by pipeline stress concentration; it is of great significance to accurately monitor the pipeline stress state for maintaining pipeline safety. In this paper, based on alternating current stress measurement (ACSM) methods, a 3D simulation model of a pipeline electromagnetic field was established by ANSYS software. The distribution law of the pipeline magnetic field and eddy current field were analyzed, and the influence of size and structure parameters of the coil inside the probe were studied. The internal stress detection system of the pipeline was designed, and the static tensile stress measurement experiment was carried out. Simulation and test results showed that the excitation coil with a larger diameter-to-height ratio had a higher measurement sensitivity. The sensitivity of the probe decreased monotonically with the increase of the difference between inner diameter and outer diameter of the detection coil. It increased monotonically with the increase of the equivalent radius of the detection coil. The best measurement results were obtained when the detection coil was located at the center of the two legs of the U-magnetic core. The results showed that the system could identify the pipeline stress concentration area effectively after detection engineering.