Shikun Liu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Shikun Liu has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Jingjing Liu
College of Automation Engineering, Northeast Electric Power University, Jilin City 132012, China
3 shared publications - Sze Shin Low
Nottingham Ningbo China Beacons of Excellence Research and Innovation Institute, The University of Nottingham Ningbo China, Ningbo 315100, China; School of Biological and Environmental Sciences, Faculty of Science and Engineering, The University of Nottingham Malaysia, Semenyih 43500, Malaysia
3 shared publications - Yifei Xu
College of Automation Engineering, Northeast Electric Power University, Jilin 132012, China
3 shared publications - Haohao Ning
School of Automation Engineering, Northeast Electric Power University, Jilin 132012, China
2 shared publications - Shixin Yu
College of Automation Engineering, Northeast Electric Power University, Jilin 132012, China
2 shared publications - Chunyan Niu
Center for Advanced Measurement Science, National Institute of Metrology, Beijing 100013, China
1 shared publication
Latest Publications
- Open Access
- 5 January 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (1) , 142
Portable Multi-Channel Electrochemical Device with Good Interaction and Wireless Connection for On-Site Testing
It is very important to rapidly test the key indicators of water in the field to fully evaluate the quality of the regional water environment. However, a high-resolution measuring device that can generate small currents for low-concentration analytes in water samples is often bulky, complex to operate, and difficult for data sharing. This work introduces a portable multi-channel electrochemical device with a small volume, good interaction, and data-sharing capabilities called PMCED. The PMCED provides an easy-to-operate graphical interactive interface to conveniently set the parameters for cyclic voltammetry or a differential pulse method performed by the four electrode channels. At the same time, the device, with a current sensitivity of 100 nA V−1, was applied to the detection of water samples with high background current and achieved a high-resolution measurement at low current levels. The PMCED uses the Narrow Band Internet of Things (NB-IoT) to meet the needs for uploading data to the cloud in remote areas. The electrochemical signal preprocessing and chemometrics models run in the cloud, and the final results are visualized on a web page, providing a remote access channel for on-site testing results.
- 5 January 2023
- Published by MDPI AG in Micromachines
- Vol. 14 (1) , 142
Open AccessPortable Multi-Channel Electrochemical Device with Good Interaction and Wireless Connection for On-Site Testing
It is very important to rapidly test the key indicators of water in the field to fully evaluate the quality of the regional water environment. However, a high-resolution measuring device that can generate small currents for low-concentration analytes in water samples is often bulky, complex to operate, and difficult for data sharing. This work introduces a portable multi-channel electrochemical device with a small volume, good interaction, and data-sharing capabilities called PMCED. The PMCED provides an easy-to-operate graphical interactive interface to conveniently set the parameters for cyclic voltammetry or a differential pulse method performed by the four electrode channels. At the same time, the device, with a current sensitivity of 100 nA V−1, was applied to the detection of water samples with high background current and achieved a high-resolution measurement at low current levels. The PMCED uses the Narrow Band Internet of Things (NB-IoT) to meet the needs for uploading data to the cloud in remote areas. The electrochemical signal preprocessing and chemometrics models run in the cloud, and the final results are visualized on a web page, providing a remote access channel for on-site testing results.
- 9 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (3) , 2847-2855
Multiplex Analysis of Fundamental Surface Water Quality Indicators by Multichannel Electrochemical Device Combined With MFCSC Model
Rapid and accurate detection of water quality is essential for environmental monitoring and management. Among them, permanganate index (COD Mn ), nitrate-nitrogen (NO 3 – -N), dissolvable inorganic phosphorus (DIP) and ammonia nitrogen (AN) are four important water quality indicators. A portable multi-channel electrochemical device (MCED) combined with sensor array composed of gold nanoparticles (AuNPs), silver nanodendritic structures (AgNDs), and reduced graphene oxide (rGO)-modified screen-printed electrodes (SPEs) was applied for facile, rapid on-site inspection. The sensor array exhibits good complementarity in voltammetric measurements of water quality indicators, and has cross-sensitivity in multiplex measurement. A Multiple Fully Connected Shared Convolution (MFCSC) model was constructed to process the voltammetric data, extracting unique features to resolve the overlap in voltammetric data of complex solutions for quantitative determination of target analytes. Accurate predictions were successfully achieved for the four parameters, COD Mn , NO 3 – -N, DIP and AN in the mixture. where COD Mn , NO 3 – -N and AN have high coefficients of determination (R 2 ) and low mean absolute percentage errors (MAPE%). Using the migration ability of MFCSC, combined with MCED, it is further applied for real water sample testing, which proves the good prediction of the water quality indicators of real water samples in complex matrices. The results show that the sensing system developed in this work has wide application potential and can be used to rapidly analyze surface water quality and obtain water quality information in a wide range of water bodies for monitoring.
- 9 December 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Sensors Journal
- Vol. 23 (3) , 2847-2855
Multiplex Analysis of Fundamental Surface Water Quality Indicators by Multichannel Electrochemical Device Combined With MFCSC Model
Rapid and accurate detection of water quality is essential for environmental monitoring and management. Among them, permanganate index (COD Mn ), nitrate-nitrogen (NO 3 – -N), dissolvable inorganic phosphorus (DIP) and ammonia nitrogen (AN) are four important water quality indicators. A portable multi-channel electrochemical device (MCED) combined with sensor array composed of gold nanoparticles (AuNPs), silver nanodendritic structures (AgNDs), and reduced graphene oxide (rGO)-modified screen-printed electrodes (SPEs) was applied for facile, rapid on-site inspection. The sensor array exhibits good complementarity in voltammetric measurements of water quality indicators, and has cross-sensitivity in multiplex measurement. A Multiple Fully Connected Shared Convolution (MFCSC) model was constructed to process the voltammetric data, extracting unique features to resolve the overlap in voltammetric data of complex solutions for quantitative determination of target analytes. Accurate predictions were successfully achieved for the four parameters, COD Mn , NO 3 – -N, DIP and AN in the mixture. where COD Mn , NO 3 – -N and AN have high coefficients of determination (R 2 ) and low mean absolute percentage errors (MAPE%). Using the migration ability of MFCSC, combined with MCED, it is further applied for real water sample testing, which proves the good prediction of the water quality indicators of real water samples in complex matrices. The results show that the sensing system developed in this work has wide application potential and can be used to rapidly analyze surface water quality and obtain water quality information in a wide range of water bodies for monitoring.
- Open Access
- 7 July 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (7) , 494
Application and Progress of Chemometrics in Voltammetric Biosensing
The voltammetric electrochemical sensing method combined with biosensors and multi-sensor systems can quickly, accurately, and reliably analyze the concentration of the main analyte and the overall characteristics of complex samples. Simultaneously, the high-dimensional voltammogram contains the rich electrochemical features of the detected substances. Chemometric methods are important tools for mining valuable information from voltammetric data. Chemometrics can aid voltammetric biosensor calibration and multi-element detection in complex matrix conditions. This review introduces the voltammetric analysis techniques commonly used in the research of voltammetric biosensor and electronic tongues. Then, the research on optimizing voltammetric biosensor results using classical chemometrics is summarized. At the same time, the incorporation of machine learning and deep learning has brought new opportunities to further improve the detection performance of biosensors in complex samples. Finally, smartphones connected with miniaturized voltammetric biosensors and chemometric methods provide a high-quality portable analysis platform that shows great potential in point-of-care testing.
- 7 July 2022
- Published by MDPI AG in Biosensors
- Vol. 12 (7) , 494
Open AccessApplication and Progress of Chemometrics in Voltammetric Biosensing
The voltammetric electrochemical sensing method combined with biosensors and multi-sensor systems can quickly, accurately, and reliably analyze the concentration of the main analyte and the overall characteristics of complex samples. Simultaneously, the high-dimensional voltammogram contains the rich electrochemical features of the detected substances. Chemometric methods are important tools for mining valuable information from voltammetric data. Chemometrics can aid voltammetric biosensor calibration and multi-element detection in complex matrix conditions. This review introduces the voltammetric analysis techniques commonly used in the research of voltammetric biosensor and electronic tongues. Then, the research on optimizing voltammetric biosensor results using classical chemometrics is summarized. At the same time, the incorporation of machine learning and deep learning has brought new opportunities to further improve the detection performance of biosensors in complex samples. Finally, smartphones connected with miniaturized voltammetric biosensors and chemometric methods provide a high-quality portable analysis platform that shows great potential in point-of-care testing.