Aditi Shivachandra Vibhute
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Aditi Shivachandra Vibhute has a total of 12 co-authors. Here are the top co-authors by number of shared publications:
- Mahendra Kumar Shrimali
National Center for Disaster Mitigation and Management, Malaviya National Institute of Technology, Jaipur, India
3 shared publications - Shiv Dayal Bharati
National Center for Disaster Mitigation and Management, Malaviya National Institute of Technology, Jaipur, India
3 shared publications Mahendra Kumar Shrimali
MNIT Jaipur: Malaviya National Institute of Technology, Jaipur, India
2 shared publicationsTushar Kanti Datta
MNIT Jaipur: Malaviya National Institute of Technology, Jaipur, India
2 shared publications- K. P. Shiyam Sundar
MNIT Jaipur
1 shared publication M.K. Shrimali
Professor, National Centre for Disaster Mitigation & Management, MNIT Jaipur, India
1 shared publication
Latest Publications
- 11 November 2025
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 13 (8) , 1-15
Seismic Performance of Base Isolated Frame Under Main and Aftershocks
- 11 November 2025
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 13 (8) , 1-15
Seismic Performance of Base Isolated Frame Under Main and Aftershocks
- 24 November 2024
- Published by Springer Nature
- p. 101-109
Seismic Performance Evaluation of Base Isolated Building Frame with LRB Under the Action of Mainshock and Aftershock
- 24 November 2024
- Published by Springer Nature
- p. 101-109
Seismic Performance Evaluation of Base Isolated Building Frame with LRB Under the Action of Mainshock and Aftershock
- 20 July 2023
- Published by Springer Nature
- p. 207-217
Seismic Response Analysis of Concrete Gravity Dam Using Response Spectrum Analysis and Response History Analysis
- 20 July 2023
- Published by Springer Nature
- p. 207-217
Seismic Response Analysis of Concrete Gravity Dam Using Response Spectrum Analysis and Response History Analysis
- 4 July 2023
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 12 (3) , 3399-3415
Seismic Behaviour of FPS-Isolated Frames Under the Action of Mainshock and Aftershocks
- 4 July 2023
- Published by Springer Nature in Journal of Vibration Engineering & Technologies
- Vol. 12 (3) , 3399-3415
Seismic Behaviour of FPS-Isolated Frames Under the Action of Mainshock and Aftershocks
- Open Access
- 19 December 2022
- Published by Alwaha Scientific Publishing Services SARL in Asps Conference Proceedings
- Vol. 1 (1) , 815-819
Seismic Performance of Elastomeric and Sliding Friction Isolation System
The base isolation technique is widely used in the isolation of structures for providing efficient protection to structures concerning different loadings. This study aims to evaluate comparative performance and inelastic responses of the base-isolated structure for two types of isolation systems under the Far-field and Near-field earthquake. For this purpose, seismic response quantities like base shear, peak ?oor displacement, absolute acceleration, and isolator displacement for ten-story reinforced concrete building frame base isolated by lead rubber bearings (LRBs) are evaluated and compared with the seismic response of the same structure base isolated by Friction Pendulum Bearing Isolator. Nonlinear time history analysis is carried out to investigate the inelastic behavior of the base-isolated structure. The building frame was designed according to IS1893:2016 seismic code and IS 456:2000. To represent a wide range of assessments, a 10 storey building frame taking identical isolation parameters for elastomeric and sliding isolation system was analyzed in SAP 2000. It was observed that the responses of both the isolation system are nearly the same for all the three earthquakes.
- 19 December 2022
- Published by Alwaha Scientific Publishing Services SARL in Asps Conference Proceedings
- Vol. 1 (1) , 815-819
Open AccessSeismic Performance of Elastomeric and Sliding Friction Isolation System
The base isolation technique is widely used in the isolation of structures for providing efficient protection to structures concerning different loadings. This study aims to evaluate comparative performance and inelastic responses of the base-isolated structure for two types of isolation systems under the Far-field and Near-field earthquake. For this purpose, seismic response quantities like base shear, peak ?oor displacement, absolute acceleration, and isolator displacement for ten-story reinforced concrete building frame base isolated by lead rubber bearings (LRBs) are evaluated and compared with the seismic response of the same structure base isolated by Friction Pendulum Bearing Isolator. Nonlinear time history analysis is carried out to investigate the inelastic behavior of the base-isolated structure. The building frame was designed according to IS1893:2016 seismic code and IS 456:2000. To represent a wide range of assessments, a 10 storey building frame taking identical isolation parameters for elastomeric and sliding isolation system was analyzed in SAP 2000. It was observed that the responses of both the isolation system are nearly the same for all the three earthquakes.
- 1 November 2022
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 27 (4) , 04022042
Optimum Coefficient of Friction in FPS for Base Isolation of Building Frames
Base isolation of structures with a friction pendulum system (FPS) has been a topic of great interest for research in the past. The efficiency of the FPS system in isolating a structure depends upon a number of crucial parameters, of which the coefficient of friction plays the most important role. Herein, two methods are presented for determining the optimum value of the dynamic coefficient of friction ( ), which provides the maximum possible reduction of significant engineering demand parameters (EDP) simultaneously. The optimum value of and the percentage of reduction of EDPs are obtained with respect to the safety gap. The procedures for determining the optimum value of are illustrated with an example of a 10-story building frame base isolated with FPS under both far-field and near-field earthquakes. The results of the study show that the reduction in the number of plastic hinges formed was highly sensitive to the variation of the coefficient of friction: reductions in other EDPs showed mild to moderate sensitivity.- 1 November 2022
- Published by American Society of Civil Engineers (ASCE) in Practice Periodical on Structural Design and Construction
- Vol. 27 (4) , 04022042
Optimum Coefficient of Friction in FPS for Base Isolation of Building Frames
Base isolation of structures with a friction pendulum system (FPS) has been a topic of great interest for research in the past. The efficiency of the FPS system in isolating a structure depends upon a number of crucial parameters, of which the coefficient of friction plays the most important role. Herein, two methods are presented for determining the optimum value of the dynamic coefficient of friction ( ), which provides the maximum possible reduction of significant engineering demand parameters (EDP) simultaneously. The optimum value of and the percentage of reduction of EDPs are obtained with respect to the safety gap. The procedures for determining the optimum value of are illustrated with an example of a 10-story building frame base isolated with FPS under both far-field and near-field earthquakes. The results of the study show that the reduction in the number of plastic hinges formed was highly sensitive to the variation of the coefficient of friction: reductions in other EDPs showed mild to moderate sensitivity.