Xiaoyan Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiaoyan Huang has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Nanfang Yu
Department of Applied Physics and Applied Mathematics, Columbia University, New York, NY 10027, USA
2 shared publications - Bensheng Qiu
Medical Imaging Center Department of Electronic Engineering and Information Science University of Science and Technology of China Hefei Anhui China
1 shared publication Changliang Wang
Hefei National Lab for Physical Science at the Microscale and the Centers for Biomedical Engineering University of Science and Technology of China Hefei, AnHui Province China
1 shared publicationChunqiong Luo
Department of Anesthesia, Sichuan Provincial Orthopedic Hospital (Chengdu Sports Hospital and Chengdu Research Institute for Sports Injury), Chengdu, 610041, China
1 shared publicationDing Chun-Feng
1 shared publicationFulang Qi
Hefei National Lab for Physical Science at the Microscale and the Centers for Biomedical Engineering University of Science and Technology of China Hefei, AnHui Province China
1 shared publication
Latest Publications
- 1 July 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (4) , 1886-1900
Development of a novel MR‐conditional microwave needle for MR‐guided interventional microwave ablation at 1.5T
Purpose To develop an MR-conditional microwave needle that generates a spherical ablation zone and clear MRI visibility for MR-guided microwave ablation. Methods An MR-conditional microwave needle consisting of zirconia tip and TA18 titanium alloy tube was investigated. The numerical model was created to optimize the needle's geometry and analyze its performance. A geometrically optimized needle was produced using non-magnetic materials based on the electromagnetics simulation results. The needle's mechanical properties were tested per the Chinese pharmaceutical industry standard YY0899-2013. The MRI visibility performance and ablation characteristics of the needle was tested both in vitro (phantom) and in vivo (rabbit) at 1.5T. The RF-induced heating was evaluated in ex vivo porcine liver. Results The needle's mechanical properties met the specified requirements. The needle susceptibility artifact was clearly visible both in vitro and in vivo. The needle artifact diameter (A) was small in in vivo (A(shaft:) 4.96 +/- 0.18 mm for T1W-FLASH, 3.13 +/- 0.05 mm for T2-weighted fast spin-echo (T2W-FSE); A(tip:) 2.31 +/- 0.09 mm for T1W-FLASH, 2.29 +/- 0.08 mm for T2W-FSE; tip location error [TLE](:) -0.94 +/- 0.07 mm for T1W-FLASH, -1.10 +/- 0.09 mm for T2W-FSE). Ablation zones generated by the needle were nearly spherical with an elliptical aspect ratio ranging from 0.79 to 0.90 at 30 W, 50 W for 3, 5, 10 min duration ex vivo ablations and 0.86 at 30 W for 10 min duration in vivo ablations. Conclusion The designed MR-conditional microwave needle offers excellent mechanical properties, reliable MRI visibility, insignificant RF-induced heating, and a sufficiently spherical ablation zone. Further clinical development of MR-guided microwave ablation appears warranted.
- 1 July 2022
- Published by Wiley in Magnetic Resonance in Medicine
- Vol. 88 (4) , 1886-1900
Development of a novel MR‐conditional microwave needle for MR‐guided interventional microwave ablation at 1.5T
Purpose To develop an MR-conditional microwave needle that generates a spherical ablation zone and clear MRI visibility for MR-guided microwave ablation. Methods An MR-conditional microwave needle consisting of zirconia tip and TA18 titanium alloy tube was investigated. The numerical model was created to optimize the needle's geometry and analyze its performance. A geometrically optimized needle was produced using non-magnetic materials based on the electromagnetics simulation results. The needle's mechanical properties were tested per the Chinese pharmaceutical industry standard YY0899-2013. The MRI visibility performance and ablation characteristics of the needle was tested both in vitro (phantom) and in vivo (rabbit) at 1.5T. The RF-induced heating was evaluated in ex vivo porcine liver. Results The needle's mechanical properties met the specified requirements. The needle susceptibility artifact was clearly visible both in vitro and in vivo. The needle artifact diameter (A) was small in in vivo (A(shaft:) 4.96 +/- 0.18 mm for T1W-FLASH, 3.13 +/- 0.05 mm for T2-weighted fast spin-echo (T2W-FSE); A(tip:) 2.31 +/- 0.09 mm for T1W-FLASH, 2.29 +/- 0.08 mm for T2W-FSE; tip location error [TLE](:) -0.94 +/- 0.07 mm for T1W-FLASH, -1.10 +/- 0.09 mm for T2W-FSE). Ablation zones generated by the needle were nearly spherical with an elliptical aspect ratio ranging from 0.79 to 0.90 at 30 W, 50 W for 3, 5, 10 min duration ex vivo ablations and 0.86 at 30 W for 10 min duration in vivo ablations. Conclusion The designed MR-conditional microwave needle offers excellent mechanical properties, reliable MRI visibility, insignificant RF-induced heating, and a sufficiently spherical ablation zone. Further clinical development of MR-guided microwave ablation appears warranted.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 4, FM4D.4
Meta-Holograms for Optical Trapping of Cold Atoms
We propose metasurface holograms as a platform to efficiently and faithfully generate designer optical traps for cold atoms.
- 1 January 2022
- Published by Optica Publishing Group
- Vol. 4, FM4D.4
Meta-Holograms for Optical Trapping of Cold Atoms
We propose metasurface holograms as a platform to efficiently and faithfully generate designer optical traps for cold atoms.
- 1 January 2021
- Published by Optica Publishing Group
- p. FM4J.5
Monolithic Bilayer Metasurface for Multicolor Phase-Amplitude Holography
We propose a monolithic bilayer metasurface platform for phase-amplitude holograms operating at up to three colors, in both visible and infrared regimes.
- 1 January 2021
- Published by Optica Publishing Group
- p. FM4J.5
Monolithic Bilayer Metasurface for Multicolor Phase-Amplitude Holography
We propose a monolithic bilayer metasurface platform for phase-amplitude holograms operating at up to three colors, in both visible and infrared regimes.
- Open Access
- 1 December 2020
- Published by Elsevier in Asian Journal of Surgery
- Vol. 43 (12) , 1142-1148
Ultrasound to guide the individual medical decision by evaluating the gastric contents and risk of aspiration: A literature review
- 1 December 2020
- Published by Elsevier in Asian Journal of Surgery
- Vol. 43 (12) , 1142-1148
Open AccessUltrasound to guide the individual medical decision by evaluating the gastric contents and risk of aspiration: A literature review
- Open Access
- 1 January 2016
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 65 (1) , 018101
Tunable terahertz absorber based on complementary graphene meta-surface
通过在石墨烯超表面设计周期性切条, 实现了基于石墨烯互补超表面的可调谐太赫兹吸波体. 通过改变外加电压来改变石墨烯的费米能级, 吸波体实现频率可调谐特性. 研究了石墨烯费米能级、结构尺寸对超材料吸波体吸收特性的影响, 并利用多重反射理论研究了其物理机理并且证明了模拟方法的可行性. 研究结果表明: 当石墨烯费米能级取0.6 eV, 基底厚度13 m, 石墨烯上切条长宽分别为2.9 m, 0.1 m 时, 吸波体在1.865 THz可以实现99.9%的完美吸收; 石墨烯费米能级从0.4 eV增大到0.9 eV, 吸波体共振频率从1.596 THz 蓝移到2.168 THz, 且伴随共振吸收率的改变, 吸收率在0.6 eV时达到最大; 通过改变费米能级实现的最大吸收率调制度达84.55%.
- 1 January 2016
- Published by Acta Physica Sinica, Chinese Physical Society and Institute of Physics, Chinese Academy of Sciences in Acta Physica Sinica
- Vol. 65 (1) , 018101
Open AccessTunable terahertz absorber based on complementary graphene meta-surface
通过在石墨烯超表面设计周期性切条, 实现了基于石墨烯互补超表面的可调谐太赫兹吸波体. 通过改变外加电压来改变石墨烯的费米能级, 吸波体实现频率可调谐特性. 研究了石墨烯费米能级、结构尺寸对超材料吸波体吸收特性的影响, 并利用多重反射理论研究了其物理机理并且证明了模拟方法的可行性. 研究结果表明: 当石墨烯费米能级取0.6 eV, 基底厚度13 m, 石墨烯上切条长宽分别为2.9 m, 0.1 m 时, 吸波体在1.865 THz可以实现99.9%的完美吸收; 石墨烯费米能级从0.4 eV增大到0.9 eV, 吸波体共振频率从1.596 THz 蓝移到2.168 THz, 且伴随共振吸收率的改变, 吸收率在0.6 eV时达到最大; 通过改变费米能级实现的最大吸收率调制度达84.55%.