Latest Publications
- 29 March 2023
- Published by Springer Nature
- p. 927-934
Multi Objective Optimization Design Method for Neutral Grounding Parameters of Large Hydropower Units
- 29 March 2023
- Published by Springer Nature
- p. 927-934
Multi Objective Optimization Design Method for Neutral Grounding Parameters of Large Hydropower Units
- Open Access
Study on Dynamic Characteristics of Single-Phase Grounding Fault of 1000 MW Hydro Generator under Different Grounding Modes
The continuous operation of 1000 MW large hydro generators in China is of great value to the implementation of “double carbon strategy” and power grid safety. However, with the continuous increase of single unit capacity of the hydro generator, the problems of unit fault grounding current and neutral point voltage drift become more and more prominent, and the traditional analysis methods cannot accurately obtain the fault dynamic data. Therefore, starting from the neutral point grounding mode of the large hydro generator, taking a 1000 MW hydro generator as the research object, this paper establishes the single-phase grounding fault model under the condition of three-phase parameter asymmetry of stator winding and analyzes the dynamic characteristics of fault current, transient overvoltage, and neutral point voltage drift under different grounding modes by using transient analysis method; the influence of frequency offset on neutral voltage drift and the dynamic characteristics of single-phase grounding fault of the large hydro generator under different grounding modes are also obtained. Finally, according to the analysis results, the selection and optimization method of neutral grounding parameters are proposed, which provides a reference for the selection of neutral grounding mode and the research of protection strategy of the large hydro generator.
Open AccessStudy on Dynamic Characteristics of Single-Phase Grounding Fault of 1000 MW Hydro Generator under Different Grounding Modes
The continuous operation of 1000 MW large hydro generators in China is of great value to the implementation of “double carbon strategy” and power grid safety. However, with the continuous increase of single unit capacity of the hydro generator, the problems of unit fault grounding current and neutral point voltage drift become more and more prominent, and the traditional analysis methods cannot accurately obtain the fault dynamic data. Therefore, starting from the neutral point grounding mode of the large hydro generator, taking a 1000 MW hydro generator as the research object, this paper establishes the single-phase grounding fault model under the condition of three-phase parameter asymmetry of stator winding and analyzes the dynamic characteristics of fault current, transient overvoltage, and neutral point voltage drift under different grounding modes by using transient analysis method; the influence of frequency offset on neutral voltage drift and the dynamic characteristics of single-phase grounding fault of the large hydro generator under different grounding modes are also obtained. Finally, according to the analysis results, the selection and optimization method of neutral grounding parameters are proposed, which provides a reference for the selection of neutral grounding mode and the research of protection strategy of the large hydro generator.