ALAnat Levin

Anat Levin

*This is an algorithmically generated author record based on publicly available information.

Anat Levin has a total of 10 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Top Cited Papers
    Open Access

    Rapid wavefront shaping using an optical gradient acquisition

    by Sagi Monin, Marina Alterman, Anat Levin

    Wavefront shaping systems enable deep tissue imaging by correcting scattering aberrations, but estimating optimal modulation correction is challenging, since it depends on the unknown tissue structures. Most current methods use slow coordinate descent algorithms, which sequentially scan all modulation parameters and query them independently, thus their complexity scales prohibitively with the number of parameters. We introduce a rapid wavefront shaping system, replacing coordinate descent with gradient descent optimization. To this end, our system acquires a gradient vector, which allows simultaneous update of all modulation parameters. We start with a non-invasive, guide-star-free score function to assess modulation quality and analytically derive its gradient with respect to all modulation parameters. Although the gradient depends on unknown tissue structure, we show it can be inferred from optical measurements. This enables fast, high-resolution wavefront correction with complexity independent of parameter count. We demonstrate the system’s effectiveness in correcting aberrations in a coherent confocal microscope.


  • Efficient Monte Carlo simulation of spatiotemporal speckles and their correlations

    by Chen Bar, Ioannis Gkioulekas, Anat Levin

    When viewed under coherent illumination, scattering materials such as tissue exhibit highly varying speckle patterns. Despite their noise-like appearance, the temporal and spatial variations of these speckles, resulting from internal tissue dynamics and/or external perturbation of the illumination, carry strong statistical information that is highly valuable for tissue analysis. The full practical applicability of these statistics is still hindered by the difficulty of simulating the speckles and their statistics. This paper proposes an efficient Monte Carlo framework that can efficiently sample physically correct speckles and estimate their covariances. While Monte Carlo algorithms were originally derived for incoherent illumination, our approach simulates complex-valued speckle fields. We compare the statistics of our speckle fields against those produced by an exact numerical wave solver and show a precise agreement, while our simulator is a few orders of magnitude faster and scales to much larger scenes. We also show that the simulator predictions accurately align with existing analytical models and simulation strategies, which currently address various partial settings of the general problem.


  • Enhancing speckle statistics for imaging inside scattering media

    by Wei-Yu Chen, Matthew O’tOole, Aswin C. Sankaranarayanan, Anat Levin

    We exploit memory effect correlations in speckles for the imaging of incoherent fluorescent sources behind scattering tissue. These correlations are often weak when imaging thick scattering tissues and complex illumination patterns, both of which greatly limit the practicality of associated techniques. In this work, we introduce a spatial light modulator between the tissue sample and the imaging sensor and capture multiple modulations of the speckle pattern. We show that by correctly designing the modulation patterns and the associated reconstruction algorithm, statistical correlations in the measurements can be greatly enhanced. We exploit this to demonstrate the reconstruction of mega-pixel sized fluorescent patterns behind the scattering tissue.


  • Fluorescent wavefront shaping using incoherent iterative phase conjugation

    by Dror Aizik, Ioannis Gkioulekas, Anat Levin, Ioannis Ioannis

    Wavefront shaping correction makes it possible to image fluorescent particles deep inside scattering tissue. This requires determining a correction mask to be placed in both the excitation and emission paths. Standard approaches select correction masks by optimizing various image metrics, a process that requires capturing a prohibitively large number of images. To reduce the acquisition cost, iterative phase conjugation techniques use the observation that the desired correction mask is an eigenvector of the tissue transmission operator. They then determine this eigenvector via optical implementations of the power iteration method, which require capturing orders of magnitude fewer images. Existing iterative phase conjugation techniques assume a linear model for the transmission of light through tissue, and thus only apply to fully coherent imaging systems. We extend such techniques to the incoherent case. The fact that light emitted from different sources sums incoherently violates the linear model and makes linear transmission operators inapplicable. We show that, surprisingly, the nonlinearity due to incoherent summation results in an order-of-magnitude acceleration in the convergence of the phase conjugation iteration.


  • Cyclopropenyllithiums as a new source of 1,1-bismetalated cyclopropyl derivatives

    by Anat Levin, Ilan Marek

    The allylmetalation of functionalised cyclopropenyllithium derivatives leads to the unique formation of 1,1-bismetalated cyclopropyl species that react selectively with different electrophiles.