BSBrian Stasak

Brian Stasak

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Brian Stasak has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Investigating Automatic Vocal Rise Time Measurement Parameters and Multi-Corpus Vowel Onset Behavior with the Voice Onset Analysis Tool (VOAT)

    by Brian Stasak, John Holik, Duy Duong Nguyen, Tomás Arias-Vergara, Michael Döllinger, Cate Madill

    Vocal rise time (VRT) acoustically measures from when vocal cord vibration begins to when phonation achieves a peak steady state. This acoustic-based study examines manual and automatic VRT measurements based on different vowel onset recordings (e.g., hard, modal, soft) from four datasets containing 146 adult Australian English-speaking females. Experiments test how the automatic Voice Onset Analysis Tool (VOAT) settings impact VRT measurement estimations. When compared to VOAT VRT baseline setting results, parameter adjustments using a Hilbert envelope 400 ms analysis segment with a low smoothing factor decreased VRT mean absolute error as low as 15.5 ms and 21.3 ms for modal and soft onsets, respectively. While the automated VOAT demonstrates objective repeatability with accelerated VRT extraction time advantages, still experiments herein show that the proposed adjusted settings are least accurate for hard onsets, whereby a mean absolute error as high as 71.0 ms is reported. Given three to five voice therapy sessions, females with voice disorders exhibited an 11% increase in VOAT VRT durations with reduced variation (6%), providing preliminary clinical evidence that this measure can assist in monitoring patients’ progress. This study reveals cross-corpora VRT norms per voice onset type, discusses VOAT parameter effects, and supports future automated VRT algorithm considerations.

  • Breaking Age Barriers With Automatic Voice-Based Depression Detection

    by Brian Stasak, Dale Joachim, Julien Epps

    Adults over the age of 60 years are a rising population at-risk for depression, and there is a need to create automatic screening for this illness. Most existing voice-based depression datasets comprise speakers younger than 60 and variations in speech due to age and depression are not well understood. In this study, which uses Patient Health Questionnaires for depression severity ground-truth, automatic depression detection is explored using acoustic-based prosodic, spectral, landmark, and voice quality features derived from smartphone recordings from 152 speakers in four different age ranges (e.g., 18–34, 35–48, 49–62, and 63–79). An age-dependent modeling paradigm for voice-based depression detection is proposed and evaluated. Results show that age-dependent models improve voice-based automatic depression classification accuracy with up to 10% absolute gains when compared with an age-agnostic model. Further, when compared with age-agnostic and gender-dependent models, age-dependent models often produced greater depressed class identification f-score sensitivity (up to 0.39 absolute gains). While automatically extracted acoustic voice features lead to statistically significant depression detection accuracy gains over the age-agnostic modeling baseline (4%–9% absolute), manually extracted voice quality features also are useful (4%–7% absolute gains over baseline). This investigation demonstrates the benefits of implementing age modeling to improve voice-based depression screening via smart devices.


  • Open Access

    Depression Classification Using n-Gram Speech Errors from Manual and Automatic Stroop Color Test Transcripts

    by Brian Stasak, Zhaocheng Huang, Julien Epps, Dale Joachim

    While the psychological Stroop color test has frequently been used to analyze response delays in temporal cognitive processing, minimal research has examined incorrect/correct verbal test response pattern differences exhibited in healthy control and clinically depressed populations. Further, the development of speech error features with an emphasis on sequential Stroop test responses has been unexplored for automatic depression classification. In this study which uses speech recorded via a smart device, an analysis of и-gram error sequence distributions shows that participants with clinical depression produce more Stroop color test errors, especially sequential errors, than the healthy controls. By utilizing и-gram error features derived from multisession manual transcripts, experimentation shows that trigram error features generate up to 95% depression classification accuracy, whereas an acoustic feature baseline achieve only upwards of 75%. Moreover, и-gram error features using ASR transcripts produced up to 90% depression classification accuracy.


  • Read speech voice quality and disfluency in individuals with recent suicidal ideation or suicide attempt

    by Brian Stasak, Julien Epps, Heather T. Schatten, Ivan W. Miller, Emily Mower Provost, Michael F. Armey


  • Automatic Detection of COVID-19 Based on Short-Duration Acoustic Smartphone Speech Analysis

    by Brian Stasak, Zhaocheng Huang, Sabah Razavi, Dale Joachim, Julien Epps

    Currently, there is an increasing global need for COVID-19 screening to help reduce the rate of infection and at-risk patient workload at hospitals. Smartphone-based screening for COVID-19 along with other respiratory illnesses offers excellent potential due to its rapid-rollout remote platform, user convenience, symptom tracking, comparatively low cost, and prompt result processing timeframe. In particular, speech-based analysis embedded in smartphone app technology can measure physiological effects relevant to COVID-19 screening that are not yet digitally available at scale in the healthcare field. Using a selection of the Sonde Health COVID-19 2020 dataset, this study examines the speech of COVID-19-negative participants exhibiting mild and moderate COVID-19-like symptoms as well as that of COVID-19-positive participants with mild to moderate symptoms. Our study investigates the classification potential of acoustic features (e.g., glottal, prosodic, spectral) from short-duration speech segments (e.g., held vowel, pataka phrase, nasal phrase) for automatic COVID-19 classification using machine learning. Experimental results indicate that certain feature-task combinations can produce COVID-19 classification accuracy of up to 80% as compared with using the all-acoustic feature baseline (68%). Further, with brute-forced n-best feature selection and speech task fusion, automatic COVID-19 classification accuracy of upwards of 82–86% was achieved, depending on whether the COVID-19-negative participant had mild or moderate COVID-19-like symptom severity.