Jin Iwasawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Jin Iwasawa has a total of 112 co-authors. Here are the top co-authors by number of shared publications:
Yoshito Iesaka
Tsuchiura Kyodo Hospital
7 shared publications- Shinsuke Miyazaki
Department of Cardiovascular Medicine Institute of Science Tokyo Tokyo Japan
6 shared publications Akio Kuroi
Cardiovascular Center, Tsuchiura Kyodo Hospital
3 shared publicationsHiroaki Nakamura
3 shared publicationsNoboru Ichihara
Cardiovascular Center, Tsuchiura Kyodo Hospital, Japan
3 shared publicationsTakamitsu Takagi
3 shared publications
Latest Publications
- 31 July 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (9) , 1859-1860
A giant step toward tailor‐made ablation for persistent atrial fibrillation
- 31 July 2024
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 35 (9) , 1859-1860
A giant step toward tailor‐made ablation for persistent atrial fibrillation
- 21 December 2022
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 34 (2) , 315-324
Preclinical evaluation of semi‐automated laser ablation for pulmonary vein isolation: A comparative study
Introduction: Visually‐guided laser balloon ablation (VGLA) currently requires careful manual rotation of the laser to create overlapping lesions. A novel semi‐automated VGLA may reduce ablation times and lesion gaps. We aimed to compare semi‐automated (SA) VGLA to that of manual (MN) VGLA.Methods: Acute: Nine swine underwent right superior pulmonary vein isolation (PVI) using either SA (n = 3, 13–18 W), MN (n = 3, 8.5–12 W), or radiofrequency (RF, n = 3, 25–40 W) and were killed acutely. Chronic: 16 swine, underwent PVI using either SA (n = 8, 15 W) or MN (n = 8, 10 W), and were survived for 1 month before being killed. All hearts were then submitted for pathological evaluation.Results: Acute: PVI was successful in all 9/9 swine with lesion counts significantly lower in the SA arm (5.3 ± 5.9, 33.7 ± 10.0, and 28.0 ± 4.4 in SA, MN, and RF arms; p = .007 for SA and MN). At necropsy, circumferentiality and transmurality were 98% and 94% in SA, 98% and 80% in MN, and 100% and 100% in RF arms. A single steam pop was noted on sectioning in the SA arm swine and occurred in the high dose (18 W) strategy. Chronic: PVI was acutely successful in 16/16 swine with no difference in PVI durability rates (62.5% vs. 75.0%), lesion transmurality (95.8 ± 17.4% vs.91.9 ± 25.9%), and circumferentiality (95.8 ± 6.6% vs. 94.8 ± 6.3%) between SA and MN arms. Catheter use time and lesion counts were lower in the SA arm compared to the MN arm (11.5 ± 12.7 vs. 21.8 ± 3.8 min, p = .046 and 4.8 ± 3.83 vs. 35.4 ± 4.4, p < .001).Conclusion: Motor‐assisted semi‐automated laser balloon ablation can improve upon procedural efficiency by reducing ablation time.
- 21 December 2022
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 34 (2) , 315-324
Preclinical evaluation of semi‐automated laser ablation for pulmonary vein isolation: A comparative study
Introduction: Visually‐guided laser balloon ablation (VGLA) currently requires careful manual rotation of the laser to create overlapping lesions. A novel semi‐automated VGLA may reduce ablation times and lesion gaps. We aimed to compare semi‐automated (SA) VGLA to that of manual (MN) VGLA.Methods: Acute: Nine swine underwent right superior pulmonary vein isolation (PVI) using either SA (n = 3, 13–18 W), MN (n = 3, 8.5–12 W), or radiofrequency (RF, n = 3, 25–40 W) and were killed acutely. Chronic: 16 swine, underwent PVI using either SA (n = 8, 15 W) or MN (n = 8, 10 W), and were survived for 1 month before being killed. All hearts were then submitted for pathological evaluation.Results: Acute: PVI was successful in all 9/9 swine with lesion counts significantly lower in the SA arm (5.3 ± 5.9, 33.7 ± 10.0, and 28.0 ± 4.4 in SA, MN, and RF arms; p = .007 for SA and MN). At necropsy, circumferentiality and transmurality were 98% and 94% in SA, 98% and 80% in MN, and 100% and 100% in RF arms. A single steam pop was noted on sectioning in the SA arm swine and occurred in the high dose (18 W) strategy. Chronic: PVI was acutely successful in 16/16 swine with no difference in PVI durability rates (62.5% vs. 75.0%), lesion transmurality (95.8 ± 17.4% vs.91.9 ± 25.9%), and circumferentiality (95.8 ± 6.6% vs. 94.8 ± 6.3%) between SA and MN arms. Catheter use time and lesion counts were lower in the SA arm compared to the MN arm (11.5 ± 12.7 vs. 21.8 ± 3.8 min, p = .046 and 4.8 ± 3.83 vs. 35.4 ± 4.4, p < .001).Conclusion: Motor‐assisted semi‐automated laser balloon ablation can improve upon procedural efficiency by reducing ablation time.
- Open Access
- 10 November 2022
- Published by Japanese Circulation Society in Circulation Reports
- Vol. 4 (11) , Content11
Content
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 10 November 2022
- Published by Japanese Circulation Society in Circulation Reports
- Vol. 4 (11) , Content11
Open AccessContent
Access full-text academic articles: J-STAGE is an online platform for Japanese academic journals.
- 24 August 2022
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 33 (10) , 2172-2173
The mini electrode‐equipped catheter: Utility for paroxysmal supraventricular tachycardia ablation
- 24 August 2022
- Published by Wiley in Journal of Cardiovascular Electrophysiology
- Vol. 33 (10) , 2172-2173
The mini electrode‐equipped catheter: Utility for paroxysmal supraventricular tachycardia ablation
- Open Access
- 8 July 2022
- Published by Wiley
The Mini Electrode-equipped Catheter: Utility for Paroxysmal Supraventricular Tachycardia Ablation
The Mini Electrode-equipped Catheter: Utility for Paroxysmal Supraventricular Tachycardia Ablation
- 8 July 2022
- Published by Wiley
Open AccessThe Mini Electrode-equipped Catheter: Utility for Paroxysmal Supraventricular Tachycardia Ablation
The Mini Electrode-equipped Catheter: Utility for Paroxysmal Supraventricular Tachycardia Ablation
- 19 August 2016
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 48 (2) , 209-214
Optimal slow pathway ablation site for slow-fast atrioventricular nodal reentrant tachycardia with 2:1 atrioventricular conduction
The exact circuit responsible for the atrioventricular (AV) nodal reentrant tachycardia (AVNRT) is still unknown. We evaluated the optimal slow pathway ablation area in patients with and without 2:1 AV conduction during the slow-fast AVNRT. Among 207 consecutive patients with slow-fast AVNRT who underwent slow pathway ablation, 12 (5.8 %) patients who had 2:1 AV conduction during tachycardia (group A) were included. Fifty-nine patients without 2:1 AV conduction during tachycardia or a lower common pathway (group B) were included as a control group. We measured the fluoroscopic vertical distance on the 45° left anterior oblique view between the optimal slow pathway ablation area and His bundle electrogram (HBE) recording site (height AH) and between the coronary sinus ostium and HBE site (height CH). The horizontal distances (width AH, width CH) on the 30° right anterior view were also measured. The tachycardia cycle length (300 ± 39 vs. 371 ± 71 ms, p = 0.001) and AH interval during tachycardia (259 ± 33 vs. 324 ± 69 ms, p = 0.001) were significantly shorter in group A than in group B. The height AH/height CH was significantly smaller in group A than in group B (0.62 ± 0.15 vs. 0.76 ± 0.27, p = 0.034) whereas height CH was similar between the two groups (22.8 ± 6.4 vs. 23.4 ± 7.5 mm, p = 0.84). The width CA and width CH were similar between the two groups. Slow pathway ablation was successfully achieved in all 71 patients without any complications. The number of applications tended to be greater in group A than in group b; however, the difference did not reach statistical significance (8.8 ± 8.0 vs. 5.2 ± 5.2, p = 0.147). The optimal slow pathway ablation area was located at a more superior position in group A than in group b.
- 19 August 2016
- Published by Springer Nature in Journal of Interventional Cardiac Electrophysiology
- Vol. 48 (2) , 209-214
Optimal slow pathway ablation site for slow-fast atrioventricular nodal reentrant tachycardia with 2:1 atrioventricular conduction
The exact circuit responsible for the atrioventricular (AV) nodal reentrant tachycardia (AVNRT) is still unknown. We evaluated the optimal slow pathway ablation area in patients with and without 2:1 AV conduction during the slow-fast AVNRT. Among 207 consecutive patients with slow-fast AVNRT who underwent slow pathway ablation, 12 (5.8 %) patients who had 2:1 AV conduction during tachycardia (group A) were included. Fifty-nine patients without 2:1 AV conduction during tachycardia or a lower common pathway (group B) were included as a control group. We measured the fluoroscopic vertical distance on the 45° left anterior oblique view between the optimal slow pathway ablation area and His bundle electrogram (HBE) recording site (height AH) and between the coronary sinus ostium and HBE site (height CH). The horizontal distances (width AH, width CH) on the 30° right anterior view were also measured. The tachycardia cycle length (300 ± 39 vs. 371 ± 71 ms, p = 0.001) and AH interval during tachycardia (259 ± 33 vs. 324 ± 69 ms, p = 0.001) were significantly shorter in group A than in group B. The height AH/height CH was significantly smaller in group A than in group B (0.62 ± 0.15 vs. 0.76 ± 0.27, p = 0.034) whereas height CH was similar between the two groups (22.8 ± 6.4 vs. 23.4 ± 7.5 mm, p = 0.84). The width CA and width CH were similar between the two groups. Slow pathway ablation was successfully achieved in all 71 patients without any complications. The number of applications tended to be greater in group A than in group b; however, the difference did not reach statistical significance (8.8 ± 8.0 vs. 5.2 ± 5.2, p = 0.147). The optimal slow pathway ablation area was located at a more superior position in group A than in group b.
- 8 February 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (6) , 950-1
Temperature-limited applications of mini-electrode catheter: authors' reply.
- 8 February 2016
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (6) , 950-1
Temperature-limited applications of mini-electrode catheter: authors' reply.
- Open Access
- 10 November 2015
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (6) , 868-872
Cavotricuspid isthmus ablation using a catheter equipped with mini electrodes on the 8 mm tip: a prospective comparison with an 8 mm dumbbell-shaped tip catheter and 8 mm tip cryothermal catheter
The mini electrodes (ME) placed on the tip of the ablation electrode provide more precise local signal. We evaluated whether ME catheter was effective for the ablation of cavotricuspid isthmus (CTI)-dependent atrial flutter. Eighty-five consecutive patients (68 men; 62 ± 10 years) underwent CTI ablation either using a catheter equipped with ME on the 8 mm tip (ME catheter) in 25 patients (Group A), 8 mm dumbbell-shaped (DS) tip catheter (DS catheter) in 30 patients (Group B), or 8 mm tip cryothermal catheter (Cryo catheter) in 30 patients (Group C). In cases of failed isthmus block, the catheter was changed to the other catheter, but patients remained in the original group following intention-to-treat analysis. The endpoint was achieved in all patients after 13 ± 7 applications in Group A, 9 ± 4 applications in Group B, and 5 ± 2 applications in Group C (P < 0.001). The fluoroscopic and procedure times were significantly longer in Group A (9 ± 7 and 28 ± 17 min, P = 0.001, and P = 0.002, respectively) when compared with Groups B (6 ± 4 and 13 ± 6 min) and C (4 ± 3 and 14 ± 7 min). A crossover was performed in 14 (56%) Group A patients, and 3 (10%) Group C patients. The mean power delivered in Group A was significantly lower than in Group B (31.3 ± 9.1 vs. 38.6 ± 7.6 W, P = 0.015). The ME catheter was found to be less effective than the Cryo catheter and a DS catheter for the CTI ablation.
- 10 November 2015
- Published by Oxford University Press (OUP) in EP Europace
- Vol. 18 (6) , 868-872
Open AccessCavotricuspid isthmus ablation using a catheter equipped with mini electrodes on the 8 mm tip: a prospective comparison with an 8 mm dumbbell-shaped tip catheter and 8 mm tip cryothermal catheter
The mini electrodes (ME) placed on the tip of the ablation electrode provide more precise local signal. We evaluated whether ME catheter was effective for the ablation of cavotricuspid isthmus (CTI)-dependent atrial flutter. Eighty-five consecutive patients (68 men; 62 ± 10 years) underwent CTI ablation either using a catheter equipped with ME on the 8 mm tip (ME catheter) in 25 patients (Group A), 8 mm dumbbell-shaped (DS) tip catheter (DS catheter) in 30 patients (Group B), or 8 mm tip cryothermal catheter (Cryo catheter) in 30 patients (Group C). In cases of failed isthmus block, the catheter was changed to the other catheter, but patients remained in the original group following intention-to-treat analysis. The endpoint was achieved in all patients after 13 ± 7 applications in Group A, 9 ± 4 applications in Group B, and 5 ± 2 applications in Group C (P < 0.001). The fluoroscopic and procedure times were significantly longer in Group A (9 ± 7 and 28 ± 17 min, P = 0.001, and P = 0.002, respectively) when compared with Groups B (6 ± 4 and 13 ± 6 min) and C (4 ± 3 and 14 ± 7 min). A crossover was performed in 14 (56%) Group A patients, and 3 (10%) Group C patients. The mean power delivered in Group A was significantly lower than in Group B (31.3 ± 9.1 vs. 38.6 ± 7.6 W, P = 0.015). The ME catheter was found to be less effective than the Cryo catheter and a DS catheter for the CTI ablation.
- Open Access
- 1 January 2015
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 79 (11) , 2335-2344
Electrocardiographic Characteristics Differentiating Epicardial Outflow Tract-Ventricular Arrhythmias Originating From the Anterior Interventricular Vein and Distal Great Cardiac Vein
The aim of this study was to identify the ECG features that might differentiate between anterior interventricular vein (AIV) and distal great cardiac vein (d-GCV) outflow tract-ventricular arrhythmias (OT-VAs). Radiofrequency catheter ablation was performed in 13 of 375 patients (3.5%) for AIV or d-GCV OT-VAs. We grouped the 13 patients by the origin, d-GCV (n=9) or AIV (n=4), and compared their ECGs and electrophysiological data. The OT-VA ECGs had S waves in lead I in all 13 patients. The voltage in the inferior lead III and peak deflection index showed no significant between-group differences (2.3±0.7 vs. 2.5±0.3 mV and 0.65±0.04 vs. 0.68±0.04 mV, respectively) for the d-GCV and AIV groups. There were also no significant between-group differences in the QaVL/QaVR, where Q denotes the amplitude of the Q wave in the suffix lead. However, the R/S ratio in V1 (1.7±1.0 [n=5] vs. 0.2±0.05, P=0.04), and QRS duration (149±16.6 vs. 123±3.8 ms, P=0.012) were greater in the d-GCG group than in the AIV group. There were no significant between-group differences in the activation time or pace mapping score at the optimal ablation sites. A low R/S ratio in V1 and shorter QRS duration may help identify AIV sites of epicardial OT-VA origin.
- 1 January 2015
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 79 (11) , 2335-2344
Open AccessElectrocardiographic Characteristics Differentiating Epicardial Outflow Tract-Ventricular Arrhythmias Originating From the Anterior Interventricular Vein and Distal Great Cardiac Vein
The aim of this study was to identify the ECG features that might differentiate between anterior interventricular vein (AIV) and distal great cardiac vein (d-GCV) outflow tract-ventricular arrhythmias (OT-VAs). Radiofrequency catheter ablation was performed in 13 of 375 patients (3.5%) for AIV or d-GCV OT-VAs. We grouped the 13 patients by the origin, d-GCV (n=9) or AIV (n=4), and compared their ECGs and electrophysiological data. The OT-VA ECGs had S waves in lead I in all 13 patients. The voltage in the inferior lead III and peak deflection index showed no significant between-group differences (2.3±0.7 vs. 2.5±0.3 mV and 0.65±0.04 vs. 0.68±0.04 mV, respectively) for the d-GCV and AIV groups. There were also no significant between-group differences in the QaVL/QaVR, where Q denotes the amplitude of the Q wave in the suffix lead. However, the R/S ratio in V1 (1.7±1.0 [n=5] vs. 0.2±0.05, P=0.04), and QRS duration (149±16.6 vs. 123±3.8 ms, P=0.012) were greater in the d-GCG group than in the AIV group. There were no significant between-group differences in the activation time or pace mapping score at the optimal ablation sites. A low R/S ratio in V1 and shorter QRS duration may help identify AIV sites of epicardial OT-VA origin.
- Open Access
- 1 January 2015
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 79 (2) , 346-350
Simple Minimal Sedation for Catheter Ablation of Atrial Fibrillation
Deep sedation or general anesthesia is generally used during atrial fibrillation (AF) ablation. The aim of this study was to report the safety and feasibility of minimal sedation during AF ablation. One thousand and fifty-two AF ablation procedures in 819 patients (62 ± 11 years, 621 men, 506 paroxysmal) were included. Boluses of intravenous hydroxyzine pamoate and pentazocine were administered, with a maximal dose of 100 mg of hydroxyzine and 60 mg of pentazocine in response to pain. If the pain was intolerable or patients requested deeper sedation, moderate sedation using dexmedetomidine or propofol was introduced. Among 819 consecutive first procedures, the procedure was completed under minimal sedation in 795 (97.1%) patients without inotropic drugs or respiratory support, whereas in 20 (2.4%) patients, anesthesia was switched to moderate sedation due to pain. Patients requiring a switch to moderate sedation were significantly younger than those without (53.6 ± 2.3 vs. 62.6 ± 10.4, P<0.01). No procedures were abandoned due to adverse effects of sedation. Significant intra-procedural blood pressure decreases requiring inotropic drugs were not observed in any patients. Among 233 patients who underwent repeat procedures, 6 (2.6%) requested moderate sedation before the procedure. The mean procedure time was 151 ± 54 min. Cardiac tamponade, unrelated to sedation, was observed in 7 (0.66%) procedures. Minimal sedation might be acceptable anesthesia in the vast majority of AF ablation procedures performed in electrophysiological laboratories.
- 1 January 2015
- Published by Japanese Circulation Society in Circulation Journal
- Vol. 79 (2) , 346-350
Open AccessSimple Minimal Sedation for Catheter Ablation of Atrial Fibrillation
Deep sedation or general anesthesia is generally used during atrial fibrillation (AF) ablation. The aim of this study was to report the safety and feasibility of minimal sedation during AF ablation. One thousand and fifty-two AF ablation procedures in 819 patients (62 ± 11 years, 621 men, 506 paroxysmal) were included. Boluses of intravenous hydroxyzine pamoate and pentazocine were administered, with a maximal dose of 100 mg of hydroxyzine and 60 mg of pentazocine in response to pain. If the pain was intolerable or patients requested deeper sedation, moderate sedation using dexmedetomidine or propofol was introduced. Among 819 consecutive first procedures, the procedure was completed under minimal sedation in 795 (97.1%) patients without inotropic drugs or respiratory support, whereas in 20 (2.4%) patients, anesthesia was switched to moderate sedation due to pain. Patients requiring a switch to moderate sedation were significantly younger than those without (53.6 ± 2.3 vs. 62.6 ± 10.4, P<0.01). No procedures were abandoned due to adverse effects of sedation. Significant intra-procedural blood pressure decreases requiring inotropic drugs were not observed in any patients. Among 233 patients who underwent repeat procedures, 6 (2.6%) requested moderate sedation before the procedure. The mean procedure time was 151 ± 54 min. Cardiac tamponade, unrelated to sedation, was observed in 7 (0.66%) procedures. Minimal sedation might be acceptable anesthesia in the vast majority of AF ablation procedures performed in electrophysiological laboratories.