Leopold Pleva
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Leopold Pleva has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Jana Pometlová
Department of Trauma Surgery, University Hospital Ostrava, Ostrava, Czech Republic
2 shared publications - Jiří Voves
Department of Trauma Surgery, University Hospital Ostrava, Ostrava, Czech Republic
2 shared publications - Lubor Bialy
Department of Trauma Surgery, University Hospital Ostrava, Ostrava, Czech Republic
2 shared publications - Adéla Vrtková
Department of Applied Mathematics, Faculty of Electrical Engineering and Computer Science, VSB—Technical University of Ostrava, 708 00 Ostrava, Czech Republic
1 shared publication Dušan Žiak
Institute of Emergency, Medicine Faculty of Medicine, University of Ostrava, Ostrava, Czech Republic
1 shared publicationG. Theisz
VŠB–Technical University of Ostrava
1 shared publication
Latest Publications
- 1 October 2023
- Vol. 38 (10) , 1119-1127
Immunohistochemical evaluation of tissues following bone implant extraction from upper and lower limb
Fractured bones can regenerate and restore their biological and mechanical properties to the state prior to the damage. In some cases, however, the treatment of fractures requires the use of supportive implants. For bone healing, three processes are essential: the inflammatory phase, the repair phase and the remodelling phase. A proper course of the first - inflammatory - stage is important to ensure a successful fracture healing process. In our study, we evaluated tissue samples immunohistochemically from the area surrounding the fractures of upper and lower limbs (bone tissue, soft tissue, and the implant-adhering tissue) for markers: CD11b, CD15, CD34, CD44, CD68, Cathepsin K, and TRAcP that are linked to the aforementioned phases. In soft tissue, higher expressions of CD68, CD34, CD15 and CD11b markers were observed than in other locations. TRAcP and Cathepsin K markers were more expressed in the bone tissue, while pigmentation, necrosis and calcification were more observed in the implant-adhering tissue. Since even the implant materials commonly perceived as inert elicit the observed inflammatory responses, new surface treatments and materials need to be developed.
- 1 October 2023
- Vol. 38 (10) , 1119-1127
Immunohistochemical evaluation of tissues following bone implant extraction from upper and lower limb
Fractured bones can regenerate and restore their biological and mechanical properties to the state prior to the damage. In some cases, however, the treatment of fractures requires the use of supportive implants. For bone healing, three processes are essential: the inflammatory phase, the repair phase and the remodelling phase. A proper course of the first - inflammatory - stage is important to ensure a successful fracture healing process. In our study, we evaluated tissue samples immunohistochemically from the area surrounding the fractures of upper and lower limbs (bone tissue, soft tissue, and the implant-adhering tissue) for markers: CD11b, CD15, CD34, CD44, CD68, Cathepsin K, and TRAcP that are linked to the aforementioned phases. In soft tissue, higher expressions of CD68, CD34, CD15 and CD11b markers were observed than in other locations. TRAcP and Cathepsin K markers were more expressed in the bone tissue, while pigmentation, necrosis and calcification were more observed in the implant-adhering tissue. Since even the implant materials commonly perceived as inert elicit the observed inflammatory responses, new surface treatments and materials need to be developed.
- 7 July 2022
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 48 (6) , 4897-4902
Comparison of fluoroscopy and fluoroscopy-based 2D computer navigation for iliosacral screw placement: a retrospective study
Purpose Treatment of pelvic fractures is often complicated. Here, we intended to evaluate the intraoperative benefits of using 2D computer navigation when compared with traditional fluoroscopy on X-ray burden, surgical time and screw placement accuracy. Methods In this study, we retrospectively evaluated the records of 25 patients who underwent osteosynthesis of a posterior pelvic fracture using fluoroscopy at the University Hospital Ostrava, Czech Republic between 2011 and 2019, and 32 patients from the same department and period in whom 2D computer navigation was used. Results Intraoperative X-ray burden was significantly lower in the group with 2D computer navigation (median 650 vs 1024 cGy/cm2), as was the duration of the surgery (41 vs 45 min). This was most obvious where two screws were inserted (X-ray dose of 994 vs 1847 cGy/cm2 and 48 vs 70 min, respectively). Correction of the path for wire placement after the original drilling was necessary in 2 patients (6%) from the 2D computer navigation group and 15 patients from the fluoroscopy group (60%). Still, no malposition of the screws nor dislocation of the posterior pelvic segment after 12 months was observed in any patient of either group; of complications, only three superficial infections in the 2D navigation group and 2 in the fluoroscopy group were observed. Conclusion 2D computer navigation is a safe and accurate method for placement of screws during posterior pelvic fracture osteosynthesis, associated with lower intraoperative radiation burden and shorter surgical times compared to standard fluoroscopy, especially if two screws are inserted.
- 7 July 2022
- Published by Springer Nature in European Journal of Trauma and Emergency Surgery
- Vol. 48 (6) , 4897-4902
Comparison of fluoroscopy and fluoroscopy-based 2D computer navigation for iliosacral screw placement: a retrospective study
Purpose Treatment of pelvic fractures is often complicated. Here, we intended to evaluate the intraoperative benefits of using 2D computer navigation when compared with traditional fluoroscopy on X-ray burden, surgical time and screw placement accuracy. Methods In this study, we retrospectively evaluated the records of 25 patients who underwent osteosynthesis of a posterior pelvic fracture using fluoroscopy at the University Hospital Ostrava, Czech Republic between 2011 and 2019, and 32 patients from the same department and period in whom 2D computer navigation was used. Results Intraoperative X-ray burden was significantly lower in the group with 2D computer navigation (median 650 vs 1024 cGy/cm2), as was the duration of the surgery (41 vs 45 min). This was most obvious where two screws were inserted (X-ray dose of 994 vs 1847 cGy/cm2 and 48 vs 70 min, respectively). Correction of the path for wire placement after the original drilling was necessary in 2 patients (6%) from the 2D computer navigation group and 15 patients from the fluoroscopy group (60%). Still, no malposition of the screws nor dislocation of the posterior pelvic segment after 12 months was observed in any patient of either group; of complications, only three superficial infections in the 2D navigation group and 2 in the fluoroscopy group were observed. Conclusion 2D computer navigation is a safe and accurate method for placement of screws during posterior pelvic fracture osteosynthesis, associated with lower intraoperative radiation burden and shorter surgical times compared to standard fluoroscopy, especially if two screws are inserted.
- 14 February 2016
- Published by Springer Nature
- p. 1-10
Finite Element Modelling of T-Plate for Treatment of Distal Radius
- 14 February 2016
- Published by Springer Nature
- p. 1-10
Finite Element Modelling of T-Plate for Treatment of Distal Radius