T. Zh. Shugaeva
Research Subjects
T. Zh. Shugaeva has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- I. F. Spivak-Lavrov
K. Zhubanov Aktobe regional university
6 shared publications - S. U. Sharipov
Қ. Жұбанов атындағы Ақтөбе өңірлік университеті, Ақтөбе, Қазақстан
3 shared publications - Zh. T. Kambarova
Buketov Karaganda National Research University
3 shared publications - Andrey A. Trubitsyn
Ryazan State Radio Engineering University
2 shared publications - A O Baisanov
T. Y. Begeldinov Military Institute of Air Defense
1 shared publication - A.B. Seiten
Актюбинский региональный университет имени К. Жубанова, Казахстан, г.Актобе
1 shared publication
Latest Publications
- Open Access
- 9 November 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (45) , 455301
Numerical modeling of an ion source and the ion-optical system of a time-of-flight mass spectrometer with axially-symmetric electrostatic mirrors
This paper presents numerical modeling of a pulsed ring ion source and the ion-optical system of a time-of-flight mass spectrometer (TOF-MS) with an axially—symmetric electrostatic mirror. The relevance of this study is determined by the fact that, in the considered electrostatic mirror configuration, ions must be introduced as a ring-shaped packet, whereas conventional ion sources generally form a beam in the shape of a small spot near the symmetry axis of the system. In this regard, a pulsed ring ion source configuration is proposed and numerically investigated, enabling the formation, extraction, and preliminary acceleration of a ring-shaped ion packet. It is shown that modifying the source geometry, reducing the accelerating gap, and introducing a correcting cylindrical electrode make it possible to reduce the effect of potential sagging, and ensure ion transmission to the entrance of the mass analyzer under conditions of strong preliminary acceleration The high efficiency of axially-symmetric electrostatic mirrors is due to their ability to provide simultaneous spatial and time-of-flight focusing of ion packets. The electrode system of such a mirror is formed by cylindrical electrodes sharing a common axis, which is consistent with the ring geometry of ion injection and enables the implementation of the two spatial and time-of-flight focusing modes, namely ‘ring-to-axis’ and ‘axis-to-ring’. The potential distribution in such a system is represented in a relatively simple analytical form. To determine the trajectories and flight times of charged particles in the electrostatic field of the deflector, dimensionless Newtonian equations are used; these equations are integrated by the Adams method with automatic selection of the integration step. The starting values required for the integration were determined using Krylov’s method of successive approximations, and the relative integration accuracy was set to 10 −9 . The calculation of spatial focusing and the arrival time of particles at the detector plane was performed using the Monte Carlo method, with normally distributed events within a specified range of initial parameters. The simulations demonstrated that the resolving power of the TOF-MS can be increased up to 5000 at 50% of the peak height, which makes the proposed system promising for compact high-sensitivity spaceborne mass spectrometers. The proposed TOF-MS configuration is intended for the analysis of low-energy ions in gas-phase applications, with particular emphasis on compact spaceborne instruments for planetary atmospheric and cometary composition measurements.
- 9 November 2026
- Published by IOP Publishing in Physica Scripta
- Vol. 101 (45) , 455301
Open AccessNumerical modeling of an ion source and the ion-optical system of a time-of-flight mass spectrometer with axially-symmetric electrostatic mirrors
This paper presents numerical modeling of a pulsed ring ion source and the ion-optical system of a time-of-flight mass spectrometer (TOF-MS) with an axially—symmetric electrostatic mirror. The relevance of this study is determined by the fact that, in the considered electrostatic mirror configuration, ions must be introduced as a ring-shaped packet, whereas conventional ion sources generally form a beam in the shape of a small spot near the symmetry axis of the system. In this regard, a pulsed ring ion source configuration is proposed and numerically investigated, enabling the formation, extraction, and preliminary acceleration of a ring-shaped ion packet. It is shown that modifying the source geometry, reducing the accelerating gap, and introducing a correcting cylindrical electrode make it possible to reduce the effect of potential sagging, and ensure ion transmission to the entrance of the mass analyzer under conditions of strong preliminary acceleration The high efficiency of axially-symmetric electrostatic mirrors is due to their ability to provide simultaneous spatial and time-of-flight focusing of ion packets. The electrode system of such a mirror is formed by cylindrical electrodes sharing a common axis, which is consistent with the ring geometry of ion injection and enables the implementation of the two spatial and time-of-flight focusing modes, namely ‘ring-to-axis’ and ‘axis-to-ring’. The potential distribution in such a system is represented in a relatively simple analytical form. To determine the trajectories and flight times of charged particles in the electrostatic field of the deflector, dimensionless Newtonian equations are used; these equations are integrated by the Adams method with automatic selection of the integration step. The starting values required for the integration were determined using Krylov’s method of successive approximations, and the relative integration accuracy was set to 10 −9 . The calculation of spatial focusing and the arrival time of particles at the detector plane was performed using the Monte Carlo method, with normally distributed events within a specified range of initial parameters. The simulations demonstrated that the resolving power of the TOF-MS can be increased up to 5000 at 50% of the peak height, which makes the proposed system promising for compact high-sensitivity spaceborne mass spectrometers. The proposed TOF-MS configuration is intended for the analysis of low-energy ions in gas-phase applications, with particular emphasis on compact spaceborne instruments for planetary atmospheric and cometary composition measurements.
- Open Access
- 3 November 2026
- Published by MDPI AG in Education Sciences
- Vol. 16 (11) , 1857
STEM Project-Based Learning in Optics Education: Achievement and Student Perceptions in a Quasi-Experimental Pilot Study
STEM Project-Based Learning has emerged as a promising pedagogical approach for fostering students’ conceptual understanding and engagement through authentic interdisciplinary learning experiences. However, evidence regarding its implementation within curriculum-integrated secondary school physics remains limited. This exploratory quasi-experimental study investigated the preliminary outcomes of a STEM PjBL intervention for Grade 11 students during a geometrical optics unit through an authentic engineering project centered on liquid lens technology for small spacecraft. A quasi-experimental design was employed with two intact Grade 11 classes (n = 16 per group): one receiving STEM PjBL instruction and one receiving conventional instruction. Students in the experimental group demonstrated significantly higher post-test achievement than those in the control group (mean difference = 22.56 points, 95% CI [12.61, 32.52], p < 0.001), with a large effect size (Cohen’s d = 1.66, 95% CI [0.85, 2.46]). These findings provide initial evidence that a curriculum-aligned STEM PjBL intervention may be associated with higher achievement in secondary physics; exploratory perception data were descriptively more favorable in the experimental group, although some items reflected activities specific to that condition. Because each instructional condition was implemented in only one intact class, the contribution of the intervention cannot be separated from class-specific factors. The findings should therefore be interpreted as exploratory associations rather than as evidence establishing a causal effect of the STEM PjBL intervention. The study shows that, in one specialized secondary school, an authentic, technologically advanced engineering project was successfully implemented within the regular curriculum time allocated to the optics unit, warranting further investigation in other settings.
- 3 November 2026
- Published by MDPI AG in Education Sciences
- Vol. 16 (11) , 1857
Open AccessSTEM Project-Based Learning in Optics Education: Achievement and Student Perceptions in a Quasi-Experimental Pilot Study
STEM Project-Based Learning has emerged as a promising pedagogical approach for fostering students’ conceptual understanding and engagement through authentic interdisciplinary learning experiences. However, evidence regarding its implementation within curriculum-integrated secondary school physics remains limited. This exploratory quasi-experimental study investigated the preliminary outcomes of a STEM PjBL intervention for Grade 11 students during a geometrical optics unit through an authentic engineering project centered on liquid lens technology for small spacecraft. A quasi-experimental design was employed with two intact Grade 11 classes (n = 16 per group): one receiving STEM PjBL instruction and one receiving conventional instruction. Students in the experimental group demonstrated significantly higher post-test achievement than those in the control group (mean difference = 22.56 points, 95% CI [12.61, 32.52], p < 0.001), with a large effect size (Cohen’s d = 1.66, 95% CI [0.85, 2.46]). These findings provide initial evidence that a curriculum-aligned STEM PjBL intervention may be associated with higher achievement in secondary physics; exploratory perception data were descriptively more favorable in the experimental group, although some items reflected activities specific to that condition. Because each instructional condition was implemented in only one intact class, the contribution of the intervention cannot be separated from class-specific factors. The findings should therefore be interpreted as exploratory associations rather than as evidence establishing a causal effect of the STEM PjBL intervention. The study shows that, in one specialized secondary school, an authentic, technologically advanced engineering project was successfully implemented within the regular curriculum time allocated to the optics unit, warranting further investigation in other settings.
- 25 June 2026
- Published by Karagandy University of the name of academician E.A. Buketov in Bulletin of the Karaganda University "Physics Series"
- Vol. 12231 (2)
Design and Performance Analysis of an Electrostatic Energy Analyzer Based on Multipole-Spherical Fields
A design of an electrostatic mirror energy analyzer for the analysis of charged particle beams based on a new ly synthesized field is proposed. The electrostatic field of the analyzer is formed as a superposition of an axi ally symmetric multipole field and a spherical field. The structure of the electrostatic field formed by the su perposition of axially symmetric octupole and spherical fields has been investigated. It is shown that varying the parameters determining the contribution of multipole components allows controlling the aberration prop erties of the electron-optical system. Conditions for compensating for second- and third-order aberrations have been obtained by selecting appropriate values for the weight coefficients of the hexapole and octupole components, which allows for a significant improvement in the focusing properties of the field. Numerical modeling of the electron-optical system and calculation of charged particle trajectories were carried out using the “FOCUS” simulation program. Two regimes of angular focusing were found. The first mode corresponds to second-order angular focusing at a particle input angle of 68°, while the second regime implements third order focusing at an input angle of 90°. The instrumental functions of the device were constructed, and the relative energy resolutions and luminosities of the analyzer were evaluated. The proposed electron-optical schemes can be used in the development of high-resolution spectrometers for analyzing charged particle beams in space research, as well as spectrographs for the energy-angle analysis of solid surfaces.
- 25 June 2026
- Published by Karagandy University of the name of academician E.A. Buketov in Bulletin of the Karaganda University "Physics Series"
- Vol. 12231 (2)
Design and Performance Analysis of an Electrostatic Energy Analyzer Based on Multipole-Spherical Fields
A design of an electrostatic mirror energy analyzer for the analysis of charged particle beams based on a new ly synthesized field is proposed. The electrostatic field of the analyzer is formed as a superposition of an axi ally symmetric multipole field and a spherical field. The structure of the electrostatic field formed by the su perposition of axially symmetric octupole and spherical fields has been investigated. It is shown that varying the parameters determining the contribution of multipole components allows controlling the aberration prop erties of the electron-optical system. Conditions for compensating for second- and third-order aberrations have been obtained by selecting appropriate values for the weight coefficients of the hexapole and octupole components, which allows for a significant improvement in the focusing properties of the field. Numerical modeling of the electron-optical system and calculation of charged particle trajectories were carried out using the “FOCUS” simulation program. Two regimes of angular focusing were found. The first mode corresponds to second-order angular focusing at a particle input angle of 68°, while the second regime implements third order focusing at an input angle of 90°. The instrumental functions of the device were constructed, and the relative energy resolutions and luminosities of the analyzer were evaluated. The proposed electron-optical schemes can be used in the development of high-resolution spectrometers for analyzing charged particle beams in space research, as well as spectrographs for the energy-angle analysis of solid surfaces.
- Open Access
- 1 January 2024
- Published by al-Farabi Kazakh National University in Recent Contributions to Physics
- Vol. 90 (3) , 77-83
Approximate calculation of static mass analyzers based on two-dimensional fields
The concurrent utilization of electric and magnetic fields in static mass analyzers proves highly effective in sparticle separation solely based on their masses, thereby ensuring remarkable analytical capabilities. High-resolution mass analyzers employ an achromatizing electrostatic system to precisely focus ion radiation by energy. Devices featuring zero energy dispersion are created through the collaborative action of electric achromatizing systems and the magnetic field within the analyzer, resulting in ion separation based solely on mass. Expanding the ion beam prior to its magnetic field exposure enhances the overall quality of static mass analyzers. This article delves into a static mass analyzer with dual ion beam focusing, elucidating the ion acceleration and deceleration processes at electrode boundaries, their focalization via a transaxial lens, and the impact of the electrostatic prism's refractive surface on the mass analyzer's "quality" parameter. Additionally, the transition from a sector homogeneous magnetic field to the fields generated by a two-dimensional magnetic prism and a three-electrode transaxial focusing lens is explored to augment the mass analyzer's linear dispersion. To refine ion beam focus pre-magnetic field entry, the proposed adoption of a two-dimensional electrostatic prism promises heightened linear dispersion in the mass analyzer while expanding the beam pre-magnetic field entry. This study also examines the impact of a two-dimensional electric prism on the charged particle beam, presenting an approximate expression for its angular energy dispersion. It is demonstrated that a prism-based mass analyzer integrating two-dimensional electric and magnetic prisms enables energy-focused operations alongside enhanced linear dispersion and reduced linear dimensions.
- 1 January 2024
- Published by al-Farabi Kazakh National University in Recent Contributions to Physics
- Vol. 90 (3) , 77-83
Open AccessApproximate calculation of static mass analyzers based on two-dimensional fields
The concurrent utilization of electric and magnetic fields in static mass analyzers proves highly effective in sparticle separation solely based on their masses, thereby ensuring remarkable analytical capabilities. High-resolution mass analyzers employ an achromatizing electrostatic system to precisely focus ion radiation by energy. Devices featuring zero energy dispersion are created through the collaborative action of electric achromatizing systems and the magnetic field within the analyzer, resulting in ion separation based solely on mass. Expanding the ion beam prior to its magnetic field exposure enhances the overall quality of static mass analyzers. This article delves into a static mass analyzer with dual ion beam focusing, elucidating the ion acceleration and deceleration processes at electrode boundaries, their focalization via a transaxial lens, and the impact of the electrostatic prism's refractive surface on the mass analyzer's "quality" parameter. Additionally, the transition from a sector homogeneous magnetic field to the fields generated by a two-dimensional magnetic prism and a three-electrode transaxial focusing lens is explored to augment the mass analyzer's linear dispersion. To refine ion beam focus pre-magnetic field entry, the proposed adoption of a two-dimensional electrostatic prism promises heightened linear dispersion in the mass analyzer while expanding the beam pre-magnetic field entry. This study also examines the impact of a two-dimensional electric prism on the charged particle beam, presenting an approximate expression for its angular energy dispersion. It is demonstrated that a prism-based mass analyzer integrating two-dimensional electric and magnetic prisms enables energy-focused operations alongside enhanced linear dispersion and reduced linear dimensions.
- Open Access
- 1 December 2023
- Published by al-Farabi Kazakh National University in Recent Contributions to Physics
- Vol. 87 (4) , 23-29
Antiresonance quadrupole system based on a circular conductive cylinder
The development of methods for calculating the physical and instrument characteristics of mass spectrometers based on correct physical and mathematical theories that allow us to design and calculate devices with improved analytical capabilities is an urgent task of corpuscular optics and scientific instrumentation. Currently, quadrupole electrostatic systems are widely used. These are primarily quadrupole lenses, quadrupole aberration correctors, quadrupole traps and quadrupole mass spectrometers. The quadrupole mass analyzer refers to the so-called antiresonance mass spectrometers, in which a part of the ions, when a beam of ions moves through an electric field having both a constant and a time-varying component, passes a field with a limited amplitude of vibrations, while the amplitude of vibrations of the other part of the ions increases indefinitely with time, and drop out of the bundle. Since the nature of the motion of charged particles depends on the mass-to-charge ratio, such an electric field can work as a mass filter, that is, pass through itself only ions having a certain value of the mass-to-charge ratio. Quadrupole systems with complex electrode geometries are usually used to create quadrupole fields, which makes their practical implementation difficult. Therefore, the development and research of quadrupole systems with a fairly simple geometry of electrodes, the fields of which can be described analytically, is quite relevant. Using a simple analytical formula for the potential and its derivatives, which accurately describes the electrostatic potential of a quadrupole field, it is possible to accurately calculate the stability regions of quadrupole ion traps when additional radio frequency fields are applied. Разработка методов расчета физических и приборных характеристик масс-спектрометров, основанных на корректных физических и математических теориях, которые позволяют проектировать и рассчитывать приборы с улучшенными аналитическими возможностями, является актуальной задачей корпускулярной оптики и научного приборостроения. В настоящее время квадрупольные электростатические системы получили широкое распространение. Это прежде всего, квадрупольные линзы, квадрупольные корректоры аберраций, квадрупольные ловушки и квадрупольные масс-спектрометры. Квадрупольный масс-анализатор относится к так называемым антирезонансным масс-спектрометрам, в которых часть ионов при движении пучка ионов через электрическое поле, имеющее, как постоянную, так и изменяющуюся во времени составляющую, проходит поле с ограниченной амплитудой колебаний, в то время как амплитуда колебаний другой части ионов неограниченно возрастает со временем, и они выбывают из пучка. Так как характер движения заряженных частиц зависит от отношения массы к заряду, то такое электрическое поле может работать как масс-фильтр, то есть пропускать через себя только ионы, имеющие определенное значение отношения массы к заряду. Для создания квадрупольных полей обычно используются квадрупольные системы со сложной геометрией электродов, что затрудняет их практическую реализацию. Поэтому достаточно актуальна разработка и исследование квадрупольных систем с достаточно простой геометрией электродов, поля которых могут быть описаны аналитически. Используя для потенциала и его производных простую аналитическую формулу, которая точно описывает электростатический потенциал квадрупольного поля, можно точно рассчитать области стабильности квадрупольных ионных ловушек при наложении дополнительных радиочастотных полей. Жақсартылған аналитикалық мүмкіндіктері бар құрылғыларды жобалауға және есептеуге мүмкіндік беретін дұрыс физикалық және математикалық теорияларға негізделген масс-спектрометрлердің физикалық және аспаптық сипаттамаларын есептеу әдістерін әзірлеу корпускулалық оптика мен ғылыми аспап жасаудың өзекті міндеті болып табылады. Қазіргі уақытта квадрупольді электростатикалық жүйелер кең таралған. Бұл, ең алдымен, квадрупольді линзалар, квадрупольді аберрация түзеткіштері, квадрупольді...
- 1 December 2023
- Published by al-Farabi Kazakh National University in Recent Contributions to Physics
- Vol. 87 (4) , 23-29
Open AccessAntiresonance quadrupole system based on a circular conductive cylinder
The development of methods for calculating the physical and instrument characteristics of mass spectrometers based on correct physical and mathematical theories that allow us to design and calculate devices with improved analytical capabilities is an urgent task of corpuscular optics and scientific instrumentation. Currently, quadrupole electrostatic systems are widely used. These are primarily quadrupole lenses, quadrupole aberration correctors, quadrupole traps and quadrupole mass spectrometers. The quadrupole mass analyzer refers to the so-called antiresonance mass spectrometers, in which a part of the ions, when a beam of ions moves through an electric field having both a constant and a time-varying component, passes a field with a limited amplitude of vibrations, while the amplitude of vibrations of the other part of the ions increases indefinitely with time, and drop out of the bundle. Since the nature of the motion of charged particles depends on the mass-to-charge ratio, such an electric field can work as a mass filter, that is, pass through itself only ions having a certain value of the mass-to-charge ratio. Quadrupole systems with complex electrode geometries are usually used to create quadrupole fields, which makes their practical implementation difficult. Therefore, the development and research of quadrupole systems with a fairly simple geometry of electrodes, the fields of which can be described analytically, is quite relevant. Using a simple analytical formula for the potential and its derivatives, which accurately describes the electrostatic potential of a quadrupole field, it is possible to accurately calculate the stability regions of quadrupole ion traps when additional radio frequency fields are applied. Разработка методов расчета физических и приборных характеристик масс-спектрометров, основанных на корректных физических и математических теориях, которые позволяют проектировать и рассчитывать приборы с улучшенными аналитическими возможностями, является актуальной задачей корпускулярной оптики и научного приборостроения. В настоящее время квадрупольные электростатические системы получили широкое распространение. Это прежде всего, квадрупольные линзы, квадрупольные корректоры аберраций, квадрупольные ловушки и квадрупольные масс-спектрометры. Квадрупольный масс-анализатор относится к так называемым антирезонансным масс-спектрометрам, в которых часть ионов при движении пучка ионов через электрическое поле, имеющее, как постоянную, так и изменяющуюся во времени составляющую, проходит поле с ограниченной амплитудой колебаний, в то время как амплитуда колебаний другой части ионов неограниченно возрастает со временем, и они выбывают из пучка. Так как характер движения заряженных частиц зависит от отношения массы к заряду, то такое электрическое поле может работать как масс-фильтр, то есть пропускать через себя только ионы, имеющие определенное значение отношения массы к заряду. Для создания квадрупольных полей обычно используются квадрупольные системы со сложной геометрией электродов, что затрудняет их практическую реализацию. Поэтому достаточно актуальна разработка и исследование квадрупольных систем с достаточно простой геометрией электродов, поля которых могут быть описаны аналитически. Используя для потенциала и его производных простую аналитическую формулу, которая точно описывает электростатический потенциал квадрупольного поля, можно точно рассчитать области стабильности квадрупольных ионных ловушек при наложении дополнительных радиочастотных полей. Жақсартылған аналитикалық мүмкіндіктері бар құрылғыларды жобалауға және есептеуге мүмкіндік беретін дұрыс физикалық және математикалық теорияларға негізделген масс-спектрометрлердің физикалық және аспаптық сипаттамаларын есептеу әдістерін әзірлеу корпускулалық оптика мен ғылыми аспап жасаудың өзекті міндеті болып табылады. Қазіргі уақытта квадрупольді электростатикалық жүйелер кең таралған. Бұл, ең алдымен, квадрупольді линзалар, квадрупольді аберрация түзеткіштері, квадрупольді...
- 8 July 2022
- Published by Springer Nature
- p. 164-175
Simulation of the Gaussian Distribution of a Random Variable Using a Standard Programm Rnd()
- 8 July 2022
- Published by Springer Nature
- p. 164-175
Simulation of the Gaussian Distribution of a Random Variable Using a Standard Programm Rnd()
- Open Access
- 28 February 2022
- Published by Institute for Analytical Instrumentation of the Russian Academy of Sciences in NAUCHNOE PRIBOROSTROENIE
- Vol. 32 (1) , 68-76
DYNAMICS OF CHARGED PARTICLES BEAM IN A TRANSAXIAL MIRROR
- 28 February 2022
- Published by Institute for Analytical Instrumentation of the Russian Academy of Sciences in NAUCHNOE PRIBOROSTROENIE
- Vol. 32 (1) , 68-76
Open AccessDYNAMICS OF CHARGED PARTICLES BEAM IN A TRANSAXIAL MIRROR
- 1 January 2020
- Published by Elsevier
- p. 181-193
Solutions of the Laplace equation in cylindrical coordinates, driven to 2D harmonic potentials
- 1 January 2020
- Published by Elsevier
- p. 181-193
Solutions of the Laplace equation in cylindrical coordinates, driven to 2D harmonic potentials