Nidhi Singh
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Nidhi Singh has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Carlos-Felipe Roa
Department of Medical Biophysics, University of Toronto, Toronto, ON M5S 1A1, Canada
3 shared publications - Christine E. M. Demore
Sunnybrook Research Institute, Sunnybrook Health Sciences Centre, University of Toronto, Toronto, ON, Canada
3 shared publications - Emmanuel Cherin
Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada
3 shared publications - Lothar Lilge
Department of Medical Biophysics, University of Toronto, Toronto, Canada
2 shared publications Aaron Boyes
Sunnybrook Research Institute, Toronto, ON, Canada
1 shared publication- Aaron Boyes
Sunnybrook Research Institute, Toronto, ON M4N 3M5, Canada
1 shared publication
Latest Publications
- Open Access
- 26 March 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (7) , 3639
Side-Illuminating Optical Fiber for High-Power-Density-Mediated Intraluminal Photoacoustic Imaging
Intraluminal photoacoustic (PA) imaging has the potential for providing physiological and functional information in wide-ranging clinical applications. Along with endoluminal ultrasound transducers, these applications require compact light delivery devices which can deliver high-energy ns-pulsed laser to the target region. In this work, we describe the design, method of fabrication and characterization of a new compact, side-fire optical fiber that can deliver high-energy laser pulses for PA imaging. Side-fire illuminators were fabricated using UV laser ablation to create windows on the side of a 1.5 mm diameter single core, multi-mode optical fiber with a reflective silver coating and a beveled end. Devices with 10 mm, 20 mm, and 30 mm window lengths were fabricated and their beam profiles characterized. Elongated side-fire fibers with −6 dB beam size up to 30.79 mm × 5.5 mm were developed. A side-fire to total output ratio of up to 0.69 and a side fire efficiency of up to 40%, relative to a standard front-fire fiber, were achieved. We evaluated the effects of high-energy ns-pulsed light propagation on the fiber by coupling the fiber to 18 mJ or 100 MW/cm2 (at 750 nm) beam from a Q-switched laser. The PA imaging with the fiber was demonstrated by detecting India ink targets embedded in chicken breast tissue over the full length of a 20 mm illumination window and over a 100° angle and by visualizing in vivo the rat ear vasculature.
- 26 March 2025
- Published by MDPI AG in Applied Sciences
- Vol. 15 (7) , 3639
Open AccessSide-Illuminating Optical Fiber for High-Power-Density-Mediated Intraluminal Photoacoustic Imaging
Intraluminal photoacoustic (PA) imaging has the potential for providing physiological and functional information in wide-ranging clinical applications. Along with endoluminal ultrasound transducers, these applications require compact light delivery devices which can deliver high-energy ns-pulsed laser to the target region. In this work, we describe the design, method of fabrication and characterization of a new compact, side-fire optical fiber that can deliver high-energy laser pulses for PA imaging. Side-fire illuminators were fabricated using UV laser ablation to create windows on the side of a 1.5 mm diameter single core, multi-mode optical fiber with a reflective silver coating and a beveled end. Devices with 10 mm, 20 mm, and 30 mm window lengths were fabricated and their beam profiles characterized. Elongated side-fire fibers with −6 dB beam size up to 30.79 mm × 5.5 mm were developed. A side-fire to total output ratio of up to 0.69 and a side fire efficiency of up to 40%, relative to a standard front-fire fiber, were achieved. We evaluated the effects of high-energy ns-pulsed light propagation on the fiber by coupling the fiber to 18 mJ or 100 MW/cm2 (at 750 nm) beam from a Q-switched laser. The PA imaging with the fiber was demonstrated by detecting India ink targets embedded in chicken breast tissue over the full length of a 20 mm illumination window and over a 100° angle and by visualizing in vivo the rat ear vasculature.
- Open Access
- 7 February 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (03) , 030901-29
Light-based therapy of infected wounds: a review of dose considerations for photodynamic microbial inactivation and photobiomodulation
Wounds caused by chronic health conditions, accidental or intentional by surgical interventions, present a tremendous direct and indirect cost burden to the healthcare systems and the patients, respectively. In 2021, the global wound care market was valued at 20.59 billion USD, and it is projected to expand at a compounded annual growth rate of over 4% until 2030. The rise in surgical procedures and chronic disease prevalence drives wound care products’ growth. The North American fraction of the direct healthcare costs exceeded 9 billion in 2021.1 The impact of direct and indirect costs for wound management also differs between high versus middle- and low-income environments. Healthcare costs and projections in some societies are increasing at much faster rates, for example, in the case of Singapore.2 Historically, critical colonization implied a microbial burden of of wound tissue being associated with delayed healing,3 but the synergy of wound microorganisms, their virulence, and quantity play significant factors in delaying wound healing.4 This leads to critical colonization being associated with biofilm infection. Hence, targeting both the microorganisms and the biofilm is required.- 7 February 2025
- Published by SPIE-Intl Soc Optical Eng in Journal of Biomedical Optics
- Vol. 30 (03) , 030901-29
Open AccessLight-based therapy of infected wounds: a review of dose considerations for photodynamic microbial inactivation and photobiomodulation
Wounds caused by chronic health conditions, accidental or intentional by surgical interventions, present a tremendous direct and indirect cost burden to the healthcare systems and the patients, respectively. In 2021, the global wound care market was valued at 20.59 billion USD, and it is projected to expand at a compounded annual growth rate of over 4% until 2030. The rise in surgical procedures and chronic disease prevalence drives wound care products’ growth. The North American fraction of the direct healthcare costs exceeded 9 billion in 2021.1 The impact of direct and indirect costs for wound management also differs between high versus middle- and low-income environments. Healthcare costs and projections in some societies are increasing at much faster rates, for example, in the case of Singapore.2 Historically, critical colonization implied a microbial burden of of wound tissue being associated with delayed healing,3 but the synergy of wound microorganisms, their virulence, and quantity play significant factors in delaying wound healing.4 This leads to critical colonization being associated with biofilm infection. Hence, targeting both the microorganisms and the biofilm is required. - Open Access
Development of a Small-Footprint 50 MHz Linear Array: Fabrication and Micro-Ultrasound Imaging Demonstration
Compact high-frequency arrays are of interest for clinical and preclinical applications in which a small-footprint or endoscopic device is needed to reach the target anatomy. However, the fabrication of compact arrays entails the connection of several dozens of small elements to the imaging system through a combination of flexible printed circuit boards at the array end and micro-coaxial cabling to the imaging system. The methods currently used, such as wire bonding, conductive adhesives, or a dry connection to a flexible circuit, considerably increase the array footprint. Here, we propose an interconnection method that uses vacuum-deposited metals, laser patterning, and electroplating to achieve a right-angle, compact, reliable connection between array elements and flexible-circuit traces. The array elements are thickened at the edges using patterned copper traces, which increases their cross-sectional area and facilitates the connection. We fabricated a 2.3 mm by 1.7 mm, 64-element linear array with elements at a 36 μm pitch connected to a 4 cm long flexible circuit, where the interconnect adds only 100 μm to each side of the array. Pulse-echo measurements yielded an average center frequency of 55 MHz and a −6 dB bandwidth of 41%. We measured an imaging resolution of 35 μm in the axial direction and 114 μm in the lateral direction and demonstrated the ex vivo imaging of porcine esophageal tissue and the in vivo imaging of avian embryonic vasculature.
Open AccessDevelopment of a Small-Footprint 50 MHz Linear Array: Fabrication and Micro-Ultrasound Imaging Demonstration
Compact high-frequency arrays are of interest for clinical and preclinical applications in which a small-footprint or endoscopic device is needed to reach the target anatomy. However, the fabrication of compact arrays entails the connection of several dozens of small elements to the imaging system through a combination of flexible printed circuit boards at the array end and micro-coaxial cabling to the imaging system. The methods currently used, such as wire bonding, conductive adhesives, or a dry connection to a flexible circuit, considerably increase the array footprint. Here, we propose an interconnection method that uses vacuum-deposited metals, laser patterning, and electroplating to achieve a right-angle, compact, reliable connection between array elements and flexible-circuit traces. The array elements are thickened at the edges using patterned copper traces, which increases their cross-sectional area and facilitates the connection. We fabricated a 2.3 mm by 1.7 mm, 64-element linear array with elements at a 36 μm pitch connected to a 4 cm long flexible circuit, where the interconnect adds only 100 μm to each side of the array. Pulse-echo measurements yielded an average center frequency of 55 MHz and a −6 dB bandwidth of 41%. We measured an imaging resolution of 35 μm in the axial direction and 114 μm in the lateral direction and demonstrated the ex vivo imaging of porcine esophageal tissue and the in vivo imaging of avian embryonic vasculature.
- Open Access
- 21 January 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (4) , 457-466
Adaptation of a Clinical High-Frequency Transrectal Ultrasound System for Prostate Photoacoustic Imaging: Implementation and Pre-clinical Demonstration
- 21 January 2024
- Published by Elsevier in Ultrasound in Medicine & Biology
- Vol. 50 (4) , 457-466
Open AccessAdaptation of a Clinical High-Frequency Transrectal Ultrasound System for Prostate Photoacoustic Imaging: Implementation and Pre-clinical Demonstration
- 7 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (10) , 2785-2797
Fine Pitch Flexible Printed Circuit Board Patterning for Miniaturized Endoscopic MicroUltrasound Arrays
Microultrasound (micro-US) has become an invaluable tool for preclinical research and in emerging applications in clinical diagnosis and treatment guidance. Several such applications can benefit from arrays with a small footprint and endoscopic form factor. However, critical challenges arise in making electrical connections to array elements in such spatial constraints. In this work, we describe a method to pattern a high-density flexible circuit cabling on a copper-on polyimide film, using laser ablation of a polymer resist and wet etching, and then demonstrate a connection to a micro-US array. We investigate laser ablation process parameters and evaluate the ability to consistently pattern continuous copper traces. A minimum 30- $\mu \text{m}$ pitch was achieved with 5- $\mu \text{m}$ -wide electrode lines, and continuity of a 5-m-long trace is demonstrated. A flexible circuit with 30-mm-long traces with 30- $\mu \text{m}$ line and 30- $\mu \text{m}$ space before fan-out was fabricated to connect in an interleaved manner to a 32-element array with 30- $\mu \text{m}$ element pitch. Metal deposition and laser ablation were used to connect and pattern the element electrodes to the copper traces of the flexible circuit. Electrical and acoustic measurements show good yield and consistent impedance across channels. Element pulse-echo tests demonstrated device functionality; the two-way pulse had 43-MHz center frequency and 40% fractional bandwidth (−6 dB). The proposed manufacturing methods facilitate the prototyping and fabrication of flexible endoscopic or small-footprint micro-US devices.
- 7 July 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
- Vol. 69 (10) , 2785-2797
Fine Pitch Flexible Printed Circuit Board Patterning for Miniaturized Endoscopic MicroUltrasound Arrays
Microultrasound (micro-US) has become an invaluable tool for preclinical research and in emerging applications in clinical diagnosis and treatment guidance. Several such applications can benefit from arrays with a small footprint and endoscopic form factor. However, critical challenges arise in making electrical connections to array elements in such spatial constraints. In this work, we describe a method to pattern a high-density flexible circuit cabling on a copper-on polyimide film, using laser ablation of a polymer resist and wet etching, and then demonstrate a connection to a micro-US array. We investigate laser ablation process parameters and evaluate the ability to consistently pattern continuous copper traces. A minimum 30- $\mu \text{m}$ pitch was achieved with 5- $\mu \text{m}$ -wide electrode lines, and continuity of a 5-m-long trace is demonstrated. A flexible circuit with 30-mm-long traces with 30- $\mu \text{m}$ line and 30- $\mu \text{m}$ space before fan-out was fabricated to connect in an interleaved manner to a 32-element array with 30- $\mu \text{m}$ element pitch. Metal deposition and laser ablation were used to connect and pattern the element electrodes to the copper traces of the flexible circuit. Electrical and acoustic measurements show good yield and consistent impedance across channels. Element pulse-echo tests demonstrated device functionality; the two-way pulse had 43-MHz center frequency and 40% fractional bandwidth (−6 dB). The proposed manufacturing methods facilitate the prototyping and fabrication of flexible endoscopic or small-footprint micro-US devices.