Andreas Körner
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Andreas Körner has a total of 124 co-authors. Here are the top co-authors by number of shared publications:
- Andreas Hutzler
Helmholtz Institute Erlangen‐Nürnberg for Renewable Energy (IET‐2) Forschungszentrum Jülich GmbH Erlangen Germany
22 shared publications - Birk Fritsch
Helmholtz Institute Erlangen‐Nürnberg for Renewable Energy (IET‐2) Forschungszentrum Jülich GmbH Erlangen Germany
11 shared publications - Karl Johann Jakob Mayrhofer
Department of Chemical and Biological Engineering, Friedrich-Alexander-Universität Erlangen-Nürnberg, Cauerstraße 1, Erlangen, Germany, 91058
10 shared publications - Serhiy Cherevko
Forschungszentrum Jülich GmbH
8 shared publications - Simon Thiele
Forschungszentrum Jülich GmbH, HI ERN (IEK-11)
8 shared publications - Lena Fiedler
Helmholtz Institute Erlangen‐Nürnberg for Renewable Energy (IET‐2) Forschungszentrum Jülich GmbH Erlangen Germany
7 shared publications
Latest Publications
- Open Access
- 3 September 2026
- Published by Wiley in Small Methods
- Vol. 10 (19) , e71010
Towards High‐Throughput Testing of Bipolar Plate Materials for Proton Exchange Membrane Water Electrolyzers: Correlative Contact Resistance and Stability Analysis
Bipolar plates (BPP) are a major cost driver in proton exchange membrane water electrolyzers for green hydrogen production that require replacement with more cost‐effective materials. However, novel materials must combine high corrosion resistance and low dissolution rates with low interfacial contact resistance (ICR). Herein, we introduce a correlative workflow for determining electrochemical dissolution using a scanning flow cell coupled on‐line to an inductively coupled plasma spectrometer and ICR, utilizing a novel miniaturized ICR setup with a sample diameter of 2 mm. The applicability of the setup is demonstrated using titanium (Ti), for which the ICR is found to increase depending on the applied oxidation potential. Furthermore, automated ICR mapping across pristine Ti sheets with a platinum (Pt) coating featuring a thickness gradient reveals a pronounced ICR decrease when the Pt layer exceeds ∼3.8 ± 1.4 nm Pt , while thicker Pt coatings (up to ∼80 nm Pt ) do not provide further improvement. These results demonstrate that ultrathin Pt coatings can already substantially reduce the ICR of titanium‐based BPP materials. Our setup enables high‐throughput screening of material libraries and provides a powerful tool for developing optimized PEMWE components with low ICR and high electrochemical stability.
- 3 September 2026
- Published by Wiley in Small Methods
- Vol. 10 (19) , e71010
Open AccessTowards High‐Throughput Testing of Bipolar Plate Materials for Proton Exchange Membrane Water Electrolyzers: Correlative Contact Resistance and Stability Analysis
Bipolar plates (BPP) are a major cost driver in proton exchange membrane water electrolyzers for green hydrogen production that require replacement with more cost‐effective materials. However, novel materials must combine high corrosion resistance and low dissolution rates with low interfacial contact resistance (ICR). Herein, we introduce a correlative workflow for determining electrochemical dissolution using a scanning flow cell coupled on‐line to an inductively coupled plasma spectrometer and ICR, utilizing a novel miniaturized ICR setup with a sample diameter of 2 mm. The applicability of the setup is demonstrated using titanium (Ti), for which the ICR is found to increase depending on the applied oxidation potential. Furthermore, automated ICR mapping across pristine Ti sheets with a platinum (Pt) coating featuring a thickness gradient reveals a pronounced ICR decrease when the Pt layer exceeds ∼3.8 ± 1.4 nm Pt , while thicker Pt coatings (up to ∼80 nm Pt ) do not provide further improvement. These results demonstrate that ultrathin Pt coatings can already substantially reduce the ICR of titanium‐based BPP materials. Our setup enables high‐throughput screening of material libraries and provides a powerful tool for developing optimized PEMWE components with low ICR and high electrochemical stability.
- Open Access
- 8 June 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Towards High-Throughput Testing of Bipolar Plate Materials for Proton Exchange Membrane Water Electrolyzers: Correlative Contact Resistance and Stability Analysis
Bipolar plates (BPP) are a major cost driver in proton exchange membrane water electrolyzers for green hydrogen production that require replacement with more cost-effective materials. However, novel materials must combine high corrosion resistance and low dissolution rates with low interfacial contact resistance (ICR). Herein, we introduce a correlative workflow for determining electrochemical dissolution using a scanning flow cell coupled on-line to inductively coupled plasma spectrometer and ICR at the identical location utilizing a novel miniaturized ICR setup with a sample diameter of 2 mm. The applicability of the setup is demonstrated using titanium (Ti), for which the ICR is found to increase depending on the applied oxidation potential. Furthermore, automated ICR mapping across pristine Ti sheets with a platinum (Pt) coating featuring a thickness gradient reveal a pronounced ICR decrease when the Pt layer exceeds ~3.8 ± 1.4 nm Pt , while thicker Pt coatings (up to ~80 nm Pt ) do not provide further improvement. These results demonstrate that ultrathin Pt coatings can already substantially reduce the ICR of titanium-based BPP materials. Our setup enables high-throughput screening of material libraries and provides a powerful tool for developing optimized PEMWE components with low ICR and high electrochemical stability.
- 8 June 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessTowards High-Throughput Testing of Bipolar Plate Materials for Proton Exchange Membrane Water Electrolyzers: Correlative Contact Resistance and Stability Analysis
Bipolar plates (BPP) are a major cost driver in proton exchange membrane water electrolyzers for green hydrogen production that require replacement with more cost-effective materials. However, novel materials must combine high corrosion resistance and low dissolution rates with low interfacial contact resistance (ICR). Herein, we introduce a correlative workflow for determining electrochemical dissolution using a scanning flow cell coupled on-line to inductively coupled plasma spectrometer and ICR at the identical location utilizing a novel miniaturized ICR setup with a sample diameter of 2 mm. The applicability of the setup is demonstrated using titanium (Ti), for which the ICR is found to increase depending on the applied oxidation potential. Furthermore, automated ICR mapping across pristine Ti sheets with a platinum (Pt) coating featuring a thickness gradient reveal a pronounced ICR decrease when the Pt layer exceeds ~3.8 ± 1.4 nm Pt , while thicker Pt coatings (up to ~80 nm Pt ) do not provide further improvement. These results demonstrate that ultrathin Pt coatings can already substantially reduce the ICR of titanium-based BPP materials. Our setup enables high-throughput screening of material libraries and provides a powerful tool for developing optimized PEMWE components with low ICR and high electrochemical stability.
- Open Access
- 6 June 2026
- Published by Royal Society of Chemistry (RSC) in Catalysis Science & Technology
- Vol. 16 (12) , 4019-4027
Ambient pressure ammonia decomposition using Ga–Co supported catalytically active liquid metal solutions
Ga–Co supported catalytically active metal solutions (SCALMS) on silicon carbide (SiC) were successfully tested for ambient pressure ammonia decomposition in the temperature range between 480 and 580 °C. Comparison studies of a Ga59Co SCALMS system with their monometallic equivalents Co/SiC and Ga/SiC revealed a massively enhanced ammonia decomposition activity of the supported alloy catalyst. The Ga59Co/SiC outperformed a monometallic benchmark Co/SiC catalyst in terms of the Co specific H2 productivity by up to one order of magnitude. Monometallic Ga/SiC, in contrast, showed no activity for ammonia decomposition up to 580 °C. We report productivities of 487 g H2 gCo −1 h−1 at 5% conversion and 550 °C at a weight hourly space velocity (WHSV) of 29 000 mLN gcat −1 h−1 for our SCALMS system. Apparent activation energies (EA,app) determined from temperature variation experiments give no indication for diffusion limitations under the applied reaction conditions. Therefore, we present a new catalyst material concept for ammonia decomposition with high potential for practical and technical application.
- 6 June 2026
- Published by Royal Society of Chemistry (RSC) in Catalysis Science & Technology
- Vol. 16 (12) , 4019-4027
Open AccessAmbient pressure ammonia decomposition using Ga–Co supported catalytically active liquid metal solutions
Ga–Co supported catalytically active metal solutions (SCALMS) on silicon carbide (SiC) were successfully tested for ambient pressure ammonia decomposition in the temperature range between 480 and 580 °C. Comparison studies of a Ga59Co SCALMS system with their monometallic equivalents Co/SiC and Ga/SiC revealed a massively enhanced ammonia decomposition activity of the supported alloy catalyst. The Ga59Co/SiC outperformed a monometallic benchmark Co/SiC catalyst in terms of the Co specific H2 productivity by up to one order of magnitude. Monometallic Ga/SiC, in contrast, showed no activity for ammonia decomposition up to 580 °C. We report productivities of 487 g H2 gCo −1 h−1 at 5% conversion and 550 °C at a weight hourly space velocity (WHSV) of 29 000 mLN gcat −1 h−1 for our SCALMS system. Apparent activation energies (EA,app) determined from temperature variation experiments give no indication for diffusion limitations under the applied reaction conditions. Therefore, we present a new catalyst material concept for ammonia decomposition with high potential for practical and technical application.
- Open Access
- 25 May 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Tracing Dissolved Iridium in Proton Exchange Membrane Water Electrolysis Using Operando Hard-X-Ray Fluorescence
Dissolution of iridium in proton exchange membrane water electrolyzer anodes is a critical challenge on the path towards low-cost and durable water electrolysis. While end-of-test analysis of electrolyzers showed that most of the dissolved catalyst redeposits in the membrane and the cathode catalyst layer, this approach offers only limited insight into the dynamics of iridium dissolution, transport, and redeposition mechanisms. By means of 2D-mapping with synchrotron-based operando X-ray fluorescence (XRF) spectroscopy, we detected dissolved iridium in the membrane electrode assembly (MEA) during electrolysis operation and traced the dynamics of its transport under varied operation conditions with reasonable temporal (20 min per map) and spatial (10 µm) resolution. During electrolysis, we observed an accumulation of dissolved iridium in the cathode catalyst layer. With the toggling flow of dry gas at the cathode, we can distinguish between mobile and redeposited iridium. Though thermodynamically favored, no significant deposition within the cathode was observed after ~1 h of electrolysis. The results obtained are another puzzle piece in the understanding of iridium dissolution in electrolyzers towards its possible mitigation.
- 25 May 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessTracing Dissolved Iridium in Proton Exchange Membrane Water Electrolysis Using Operando Hard-X-Ray Fluorescence
Dissolution of iridium in proton exchange membrane water electrolyzer anodes is a critical challenge on the path towards low-cost and durable water electrolysis. While end-of-test analysis of electrolyzers showed that most of the dissolved catalyst redeposits in the membrane and the cathode catalyst layer, this approach offers only limited insight into the dynamics of iridium dissolution, transport, and redeposition mechanisms. By means of 2D-mapping with synchrotron-based operando X-ray fluorescence (XRF) spectroscopy, we detected dissolved iridium in the membrane electrode assembly (MEA) during electrolysis operation and traced the dynamics of its transport under varied operation conditions with reasonable temporal (20 min per map) and spatial (10 µm) resolution. During electrolysis, we observed an accumulation of dissolved iridium in the cathode catalyst layer. With the toggling flow of dry gas at the cathode, we can distinguish between mobile and redeposited iridium. Though thermodynamically favored, no significant deposition within the cathode was observed after ~1 h of electrolysis. The results obtained are another puzzle piece in the understanding of iridium dissolution in electrolyzers towards its possible mitigation.
- Open Access
- 30 March 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Revealing Structure-Performance Relations in Core-Shell Catalyst Based PEM Water Electrolyzer Anodes with Low Iridium Loading
Reducing iridium loading in proton exchange membrane water electrolyzer anodes is essential to meet cost targets for large-scale green hydrogen production. Here, we report a photodeposition-based synthesis of TiO 2 @IrO 2 core-shell catalysts with iridium contents as low as 10 wt%. The influence of annealing temperature, iridium content, and iridium loading on structural and electrochemical properties is systematically investigated. An annealing temperature of 450 °C provides the best compromise between activity, conductivity, and stability. Remarkably, even at 10 wt% Ir (≈ 4.5 vol% IrO 2 ), the core-shell architecture maintains high electronic conductivity and mass activity. The low iridium content results in ~18 µm thick catalyst layers at a loading of 0.35 mg Ir cm ‑2 , corresponding to a high thickness factor of 52.0 ± 0.8 µm (mg Ir cm ‑2 ) ‑1 . Two-dimensional, two‑phase performance modeling reveals that these thick catalyst layers improve electronic connectivity at low loadings, leading to higher catalyst utilization than a commercial reference. As a result, the core-shell catalyst outperforms the reference in single-cell measurements, achieving 1.77 V at 2 A cm ‑2 at a low loading of 0.31 mg Ir cm ‑2 . During 200 h durability testing, reversible degradation is observed, while irreversible losses remain on par with the reference and the core–shell structure is preserved.
- 30 March 2026
- Published by American Chemical Society (ACS) in ChemRxiv
Open AccessRevealing Structure-Performance Relations in Core-Shell Catalyst Based PEM Water Electrolyzer Anodes with Low Iridium Loading
Reducing iridium loading in proton exchange membrane water electrolyzer anodes is essential to meet cost targets for large-scale green hydrogen production. Here, we report a photodeposition-based synthesis of TiO 2 @IrO 2 core-shell catalysts with iridium contents as low as 10 wt%. The influence of annealing temperature, iridium content, and iridium loading on structural and electrochemical properties is systematically investigated. An annealing temperature of 450 °C provides the best compromise between activity, conductivity, and stability. Remarkably, even at 10 wt% Ir (≈ 4.5 vol% IrO 2 ), the core-shell architecture maintains high electronic conductivity and mass activity. The low iridium content results in ~18 µm thick catalyst layers at a loading of 0.35 mg Ir cm ‑2 , corresponding to a high thickness factor of 52.0 ± 0.8 µm (mg Ir cm ‑2 ) ‑1 . Two-dimensional, two‑phase performance modeling reveals that these thick catalyst layers improve electronic connectivity at low loadings, leading to higher catalyst utilization than a commercial reference. As a result, the core-shell catalyst outperforms the reference in single-cell measurements, achieving 1.77 V at 2 A cm ‑2 at a low loading of 0.31 mg Ir cm ‑2 . During 200 h durability testing, reversible degradation is observed, while irreversible losses remain on par with the reference and the core–shell structure is preserved.
- Open Access
Live Imaging of Silver Nanostructures Electrochemically Dissolving at Open‐Circuit Potential
The stability of electrode and electrocatalyst materials is of paramount importance for sustainable and persistent technological solutions for energy conversion systems. In fact, dissolution of electrodes at open‐circuit potential occurs both during electrochemical testing operando and using a scanning flow cell‐inductively coupled plasma‐mass spectrometry (SFC‐ICP‐MS) setup. Although these phenomena occur frequently, their mechanisms remain concealed. This is because structural changes occur at the nanoscale, which are difficult to observe directly. Herein, we introduce a workflow comprising automated image analysis, beam effect assessment, and correlative electrochemical testing to obtain quantitative and representative data from electrochemical liquid phase electron microscopy (EC‐LP‐EM). In a demonstrator experiment, we reveal that the dissolution of silver electrodeposited on a platinum electrode substrate is driven by system equilibration involving the oxygen reduction reaction and bimetallic corrosion. This combination of reactions occurs at the electrode‐electrolyte interface under zero net current conditions as an example of structural changes on the nanoscale during operation. Our experimental findings, furthermore, serve as a blueprint for correlating nanoscale live imaging information with macroscopic electrochemical responses to investigate degradation mechanisms of electrocatalysts and materials beyond. These insights aid in designing efficient electrochemical conversion systems, urgently needed in renewable energy technology.
Open AccessLive Imaging of Silver Nanostructures Electrochemically Dissolving at Open‐Circuit Potential
The stability of electrode and electrocatalyst materials is of paramount importance for sustainable and persistent technological solutions for energy conversion systems. In fact, dissolution of electrodes at open‐circuit potential occurs both during electrochemical testing operando and using a scanning flow cell‐inductively coupled plasma‐mass spectrometry (SFC‐ICP‐MS) setup. Although these phenomena occur frequently, their mechanisms remain concealed. This is because structural changes occur at the nanoscale, which are difficult to observe directly. Herein, we introduce a workflow comprising automated image analysis, beam effect assessment, and correlative electrochemical testing to obtain quantitative and representative data from electrochemical liquid phase electron microscopy (EC‐LP‐EM). In a demonstrator experiment, we reveal that the dissolution of silver electrodeposited on a platinum electrode substrate is driven by system equilibration involving the oxygen reduction reaction and bimetallic corrosion. This combination of reactions occurs at the electrode‐electrolyte interface under zero net current conditions as an example of structural changes on the nanoscale during operation. Our experimental findings, furthermore, serve as a blueprint for correlating nanoscale live imaging information with macroscopic electrochemical responses to investigate degradation mechanisms of electrocatalysts and materials beyond. These insights aid in designing efficient electrochemical conversion systems, urgently needed in renewable energy technology.
- Open Access
In Situ Photocorrosion Assessment of Protected Hematite Photoanodes During Accelerated Stress Tests
Nanostructured α‐hematite (Fe 2 O 3 ) is a widely studied material for photoanode applications, particularly for driving the oxygen evolution reaction (OER) under visible light irradiation in photoelectrochemical (PEC) cells. Our recent work has shown that Fe 2 O 3 suffers from photocorrosion in alkaline and neutral electrolytes, with a noticeable decline in performance after 5 h of operation. This highlights the need for strategies that enhance the stability of Fe 2 O 3 ‐based photoanodes. To enhance the stability of Fe 2 O 3 nanorods (NR), we employed atomic layer deposition (ALD) to coat the NR with a well‐defined, controlled TiO 2 overlayer designed to protect the photoanode from photocorrosion during PEC operation. The influence of overlayer thickness is evaluated regarding the PEC activity, stability, and photocurrent retention in alkaline electrolyte using a PEC scanning flow cell coupled to an inductively coupled plasma mass spectrometer (PEC‐ICP‐MS). This setup can quantify metal dissolution during PEC OER, allowing the characterization of the photo‐degradation under realistic illumination conditions. An accelerated stress test (AST) protocol was designed to drive degradation faster and obtain insightful information about the stability of the TiO 2 @Fe 2 O 3 heterostructures using in situ PEC‐ICP‐MS. PEC‐ICP‐MS measurements demonstrate that the TiO 2 coating significantly enhances the photocorrosion resistance of Fe 2 O 3 NR in alkaline electrolytes during operation. A TiO 2 thickness of 2.8 nm (50 ALD cycles) offered the most favorable compromise between activity, photocurrent retention, and decrease of Fe dissolution. The proposed methodology combines in situ stability quantification and ASTs as a powerful tool to advance material development and can be extended to other protected photoanodes.
Open AccessIn Situ Photocorrosion Assessment of Protected Hematite Photoanodes During Accelerated Stress Tests
Nanostructured α‐hematite (Fe 2 O 3 ) is a widely studied material for photoanode applications, particularly for driving the oxygen evolution reaction (OER) under visible light irradiation in photoelectrochemical (PEC) cells. Our recent work has shown that Fe 2 O 3 suffers from photocorrosion in alkaline and neutral electrolytes, with a noticeable decline in performance after 5 h of operation. This highlights the need for strategies that enhance the stability of Fe 2 O 3 ‐based photoanodes. To enhance the stability of Fe 2 O 3 nanorods (NR), we employed atomic layer deposition (ALD) to coat the NR with a well‐defined, controlled TiO 2 overlayer designed to protect the photoanode from photocorrosion during PEC operation. The influence of overlayer thickness is evaluated regarding the PEC activity, stability, and photocurrent retention in alkaline electrolyte using a PEC scanning flow cell coupled to an inductively coupled plasma mass spectrometer (PEC‐ICP‐MS). This setup can quantify metal dissolution during PEC OER, allowing the characterization of the photo‐degradation under realistic illumination conditions. An accelerated stress test (AST) protocol was designed to drive degradation faster and obtain insightful information about the stability of the TiO 2 @Fe 2 O 3 heterostructures using in situ PEC‐ICP‐MS. PEC‐ICP‐MS measurements demonstrate that the TiO 2 coating significantly enhances the photocorrosion resistance of Fe 2 O 3 NR in alkaline electrolytes during operation. A TiO 2 thickness of 2.8 nm (50 ALD cycles) offered the most favorable compromise between activity, photocurrent retention, and decrease of Fe dissolution. The proposed methodology combines in situ stability quantification and ASTs as a powerful tool to advance material development and can be extended to other protected photoanodes.
- Open Access
- 20 October 2025
- Published by Springer Nature in Research Square
Live imaging of silver nanostructures electrochemically dissolving at open circuit potential
The stability of electrode and electrocatalyst materials is of paramount importance for sustainable and persistent technological solutions for energy conversion systems. In fact, dissolution of electrodes at open-circuit potential occurs both during electrochemical testing operando and using a scanning flow cell inductively coupled plasma mass spectrometry (SFC-ICP-MS) setup. Even though these phenomena occur often, their mechanisms remain concealed. This is because structural changes take place at the nanoscale which are difficult to directly observe. Herein, we introduce a workflow comprising automated image analysis, beam effect assessment, and correlative electrochemical testing, to obtain quantitative and representative data from electrochemical liquid phase electron microscopy (EC-LP-EM). In a demonstrator experiment, we reveal the mechanism of bimetallic corrosion for silver electrodeposited on a platinum electrode substrate upon system equilibration. This process is governed by electrochemical reactions occurring at the electrode-electrolyte interface under zero net current conditions as an example of structural changes on the nanoscale during operation. Our experimental findings, furthermore, act as a blueprint for correlating nanoscale live imaging information with macroscopic electrochemical responses for investigating degradation mechanisms of electrocatalysts and materials beyond. These insights aid to design efficient electrochemical conversion systems urgently needed in renewable energy technology.
- 20 October 2025
- Published by Springer Nature in Research Square
Open AccessLive imaging of silver nanostructures electrochemically dissolving at open circuit potential
The stability of electrode and electrocatalyst materials is of paramount importance for sustainable and persistent technological solutions for energy conversion systems. In fact, dissolution of electrodes at open-circuit potential occurs both during electrochemical testing operando and using a scanning flow cell inductively coupled plasma mass spectrometry (SFC-ICP-MS) setup. Even though these phenomena occur often, their mechanisms remain concealed. This is because structural changes take place at the nanoscale which are difficult to directly observe. Herein, we introduce a workflow comprising automated image analysis, beam effect assessment, and correlative electrochemical testing, to obtain quantitative and representative data from electrochemical liquid phase electron microscopy (EC-LP-EM). In a demonstrator experiment, we reveal the mechanism of bimetallic corrosion for silver electrodeposited on a platinum electrode substrate upon system equilibration. This process is governed by electrochemical reactions occurring at the electrode-electrolyte interface under zero net current conditions as an example of structural changes on the nanoscale during operation. Our experimental findings, furthermore, act as a blueprint for correlating nanoscale live imaging information with macroscopic electrochemical responses for investigating degradation mechanisms of electrocatalysts and materials beyond. These insights aid to design efficient electrochemical conversion systems urgently needed in renewable energy technology.
- Open Access
- 19 September 2025
- Published by Springer Nature in MRS Advances
- Vol. 11 (9) , 1-15
A snapshot review on utilizing radiolysis in electrochemical liquid phase electron microscopy for accelerated degradation analyses
Live imaging of electrochemical processes using electrochemical liquid phase electron microscopy (EC-LP-EM) setups is a cutting-edge research field, enabling insights into the dynamic behavior of the electrode–electrolyte interface at the nanoscale. Yet, size constraints in EC-LP-EM chips used for analyses add significant complexity, considering electrode architectures, mass transport properties, and operation. Additionally, radiolysis induced by electron probe–electrolyte interactions interferes with electrochemical signals. This snapshot review summarizes fundamental electrochemical concepts and how experimental observations are affected by the introduced radiolysis. Furthermore, we highlight studies that handled beam effects, obtaining in situ electrochemical data consistent with non-irradiated or ex situ counterparts. Instead of discussing artifacts, we propose ways for harnessing radiolysis to tailor harsher environments for accelerated stress tests (AST) to study degradation mechanisms of energy materials. This might aid particularly in the understanding and development of improved materials for electrochemical energy conversion devices, i.e., batteries, fuel cells, and electrolyzers. Graphic Abstract
- 19 September 2025
- Published by Springer Nature in MRS Advances
- Vol. 11 (9) , 1-15
Open AccessA snapshot review on utilizing radiolysis in electrochemical liquid phase electron microscopy for accelerated degradation analyses
Live imaging of electrochemical processes using electrochemical liquid phase electron microscopy (EC-LP-EM) setups is a cutting-edge research field, enabling insights into the dynamic behavior of the electrode–electrolyte interface at the nanoscale. Yet, size constraints in EC-LP-EM chips used for analyses add significant complexity, considering electrode architectures, mass transport properties, and operation. Additionally, radiolysis induced by electron probe–electrolyte interactions interferes with electrochemical signals. This snapshot review summarizes fundamental electrochemical concepts and how experimental observations are affected by the introduced radiolysis. Furthermore, we highlight studies that handled beam effects, obtaining in situ electrochemical data consistent with non-irradiated or ex situ counterparts. Instead of discussing artifacts, we propose ways for harnessing radiolysis to tailor harsher environments for accelerated stress tests (AST) to study degradation mechanisms of energy materials. This might aid particularly in the understanding and development of improved materials for electrochemical energy conversion devices, i.e., batteries, fuel cells, and electrolyzers. Graphic Abstract
- Open Access
- 18 March 2025
- Published by Wiley in ChemElectroChem
- Vol. 12 (9)
Electrooxidation of 2‐Propanol on Mono‐ and Bi‐Metallic Noble Metal Nanoparticles in Alkaline Studied with Real‐Time Product and Dissolution Characterization
The selective electrochemical oxidation of 2‐propanol to acetone can be used in fuel cells to deliver low‐carbon electricity and efficiently utilize hydrogen that is stored in liquid organic hydrogen carrier molecules. Here we study the electrooxidation of 2‐propanol in alkaline electrolyte, on various commercially available carbon‐supported mono‐ and bi‐metallic noble metal nanoparticles. We use voltammetry to compare the activity of different catalysts, and we combine a flow cell with real‐time analytics to monitor the products of the reaction and the dissolution of metal atoms in the presence and absence of 2‐propanol. While acetone if formed on all catalysts, our results show that the onset potential is the lowest for PtRu/C, Rh/C and PdRh/C, but the oxidation current for the latter reaches a much higher value before the surface is passivated, suggesting that PdRh/C would be preferred in an alkaline fuel cell that is fed with 2‐propanol. Online dissolution monitoring suggests that the anode in a 2‐propanol fuel cell should not be exposed to potentials above ca. +0.8 V during transient operation, i. e., during startup/shutdown conditions, to prevent dissolution of palladium and rhodium from the catalyst surface.
- 18 March 2025
- Published by Wiley in ChemElectroChem
- Vol. 12 (9)
Open AccessElectrooxidation of 2‐Propanol on Mono‐ and Bi‐Metallic Noble Metal Nanoparticles in Alkaline Studied with Real‐Time Product and Dissolution Characterization
The selective electrochemical oxidation of 2‐propanol to acetone can be used in fuel cells to deliver low‐carbon electricity and efficiently utilize hydrogen that is stored in liquid organic hydrogen carrier molecules. Here we study the electrooxidation of 2‐propanol in alkaline electrolyte, on various commercially available carbon‐supported mono‐ and bi‐metallic noble metal nanoparticles. We use voltammetry to compare the activity of different catalysts, and we combine a flow cell with real‐time analytics to monitor the products of the reaction and the dissolution of metal atoms in the presence and absence of 2‐propanol. While acetone if formed on all catalysts, our results show that the onset potential is the lowest for PtRu/C, Rh/C and PdRh/C, but the oxidation current for the latter reaches a much higher value before the surface is passivated, suggesting that PdRh/C would be preferred in an alkaline fuel cell that is fed with 2‐propanol. Online dissolution monitoring suggests that the anode in a 2‐propanol fuel cell should not be exposed to potentials above ca. +0.8 V during transient operation, i. e., during startup/shutdown conditions, to prevent dissolution of palladium and rhodium from the catalyst surface.