Ralf Diener
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ralf Diener has a total of 30 co-authors. Here are the top co-authors by number of shared publications:
A. Herkert
DESY, Notkestr 85, D-22607 Hamburg, Germany
1 shared publicationA. Schöning
1 shared publication- Adriana Simancas
Deutsches Elektronen-Synchrotron DESY, Notkestr. 85, 22607 Hamburg, Germany
1 shared publication B. Weinläder
1 shared publicationCarles Puigdengoles
Institut de Física d'Altes Energies (IFAE), Edifici Cn, Universitat Autònoma de Barcelona (UAB), E-08193 Bellaterra, Spain
1 shared publicationD. Immig
Heidelberg Univ, Phys Inst, INF 226, D-69120 Heidelberg, Germany
1 shared publication
Latest Publications
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 4598-4603
Characterization of CdTe detector for use in PET
CdTe diode detectors with Schottky contact have been characterized in terms of energy resolution and time of response. A resolution of 0.98% at 511keV has been achieved with a 4 mm × 4 mm × 2 mm detector at 900 V/mm and -7 °C. At the same bias and temperature conditions, two identical CdTe detectors show a coincidence time FWHM of 25 ns. Additionally, the effect of a strong magnetic field on the charge sharing has been studied for a 9-pixel array detector of 55 μm × 55 μm × 800 μm pixel size connected to MediPix2 front end electronics. No effect on the charge sharing distribution has been observed up to 4 T. These results show that CdTe Schottky diodes are excellent candidates for the development of next generation nuclear medical imaging devices such as PET, Compton gamma camera, and especially PET-MRI when used in a magnetic field immune configuration.
- 1 October 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 10823654,p. 4598-4603
Characterization of CdTe detector for use in PET
CdTe diode detectors with Schottky contact have been characterized in terms of energy resolution and time of response. A resolution of 0.98% at 511keV has been achieved with a 4 mm × 4 mm × 2 mm detector at 900 V/mm and -7 °C. At the same bias and temperature conditions, two identical CdTe detectors show a coincidence time FWHM of 25 ns. Additionally, the effect of a strong magnetic field on the charge sharing has been studied for a 9-pixel array detector of 55 μm × 55 μm × 800 μm pixel size connected to MediPix2 front end electronics. No effect on the charge sharing distribution has been observed up to 4 T. These results show that CdTe Schottky diodes are excellent candidates for the development of next generation nuclear medical imaging devices such as PET, Compton gamma camera, and especially PET-MRI when used in a magnetic field immune configuration.