Daniela Andone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Daniela Andone has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Ioana Fagarasan
Department of Automatic Control and Industrial Informatics, National University of Science and Technology POLITEHNICA Bucharest, 060042 Bucharest, Romania
3 shared publications Andrei Hossu
University “POLITEHNICA” of Bucharest, Faculty of Control and Computers, Splaiul Independentei nr.313, Bucuresti – 77206, Romania. Tel.:
1 shared publication- Daniel Marian Merezeanu1 shared publication
Matei Dobrescu
University “POLITEHNICA” of Bucharest, Faculty of Control and Computers, Splaiul Independentei nr.313, Bucuresti – 77206, Romania. Tel.:
1 shared publication- Matei R. Dobrescu
Member, IEEE, POLITEHNICA University of Bucharest, Faculty of Control and Computers, Splaiul Independentei 313, Bucharest 7100, Romania. telephone: +40214029105
1 shared publication Radu Dobrescu
University “POLITEHNICA” of Bucharest, Faculty of Control and Computers, Splaiul Independentei nr.313, Bucuresti – 77206, Romania. Tel.:
1 shared publication
Latest Publications
- Open Access
Tandem Queueing Systems Maximum Throughput Problem
In this paper we consider the problem of maximum throughput for tandem queueing system. We modeled this system as a Quasi-Birth-Death process. In order to do this we named level the number of customers waiting in the first buffer (including the customer in service) and we called phase the state of the remining servers. Using this model we studied the problem of maximum throughput of the system: the maximum arrival rate that a given system could support before becoming saturated, or unstable. We considered different particular cases of such systems, which were obtained by modifying the capacity of the intermediary buffers, the arrival rate and the service rates. The results of the simulations are presented in our paper and can be summed up in the following conclusions: 1. The analytic formula for the maximum throughput of the system tends to become rather complicated when the number of servers increase 2. The maximum throughput of the system converges as the number of servers increases 3. The homogeneous case reveals an interesting characteristic: if we reverse the order of the servers, maximum thruoughput of the system remains unchanged The QBD process used for the case of Poisson arrivals can be extended to model more general arrival processes.
Open AccessTandem Queueing Systems Maximum Throughput Problem
In this paper we consider the problem of maximum throughput for tandem queueing system. We modeled this system as a Quasi-Birth-Death process. In order to do this we named level the number of customers waiting in the first buffer (including the customer in service) and we called phase the state of the remining servers. Using this model we studied the problem of maximum throughput of the system: the maximum arrival rate that a given system could support before becoming saturated, or unstable. We considered different particular cases of such systems, which were obtained by modifying the capacity of the intermediary buffers, the arrival rate and the service rates. The results of the simulations are presented in our paper and can be summed up in the following conclusions: 1. The analytic formula for the maximum throughput of the system tends to become rather complicated when the number of servers increase 2. The maximum throughput of the system converges as the number of servers increases 3. The homogeneous case reveals an interesting characteristic: if we reverse the order of the servers, maximum thruoughput of the system remains unchanged The QBD process used for the case of Poisson arrivals can be extended to model more general arrival processes.
- 26 September 2006
- Published by SAGE Publications in Integrated Computer-Aided Engineering
- Vol. 13 (4) , 347-359
Application of fuzzy model predictive control to a drum-boiler
Economic feasibility of a power plant requires smooth and uninterrupted plant operation in the face of varying electrical power demand. The feed-water system in a power plant is a major contributor to plant unavailability. In this paper, a fuzzy mode
- 26 September 2006
- Published by SAGE Publications in Integrated Computer-Aided Engineering
- Vol. 13 (4) , 347-359
Application of fuzzy model predictive control to a drum-boiler
Economic feasibility of a power plant requires smooth and uninterrupted plant operation in the face of varying electrical power demand. The feed-water system in a power plant is a major contributor to plant unavailability. In this paper, a fuzzy mode
- 1 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 338-343
Advanced Control of a Steam Generator
Economic feasibility of a nuclear power plant requires smooth and uninterrupted plant operation in the face of varying electrical power demand. The feed-water system in a nuclear power plant is a major contributor to plant unavailability. The investigations about operation experiences of a power plant show that one of frequent causes of shutdowns is by violation of safety limits on the water level and is common at low operating power where the plant exhibits strong non-minimum phase characteristics. This paper presents a framework for addressing this problem based on a method of advanced control based on fuzzy model predictive control. Furthermore, fuzzy model based fault detection methods are elaborated envisaging fault tolerant control. Results from validation of the advanced control system are presented. A new concept of modular advanced control system designed for a seamless and gradual integration into the existing distributed control system is proposed
- 1 September 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 338-343
Advanced Control of a Steam Generator
Economic feasibility of a nuclear power plant requires smooth and uninterrupted plant operation in the face of varying electrical power demand. The feed-water system in a nuclear power plant is a major contributor to plant unavailability. The investigations about operation experiences of a power plant show that one of frequent causes of shutdowns is by violation of safety limits on the water level and is common at low operating power where the plant exhibits strong non-minimum phase characteristics. This paper presents a framework for addressing this problem based on a method of advanced control based on fuzzy model predictive control. Furthermore, fuzzy model based fault detection methods are elaborated envisaging fault tolerant control. Results from validation of the advanced control system are presented. A new concept of modular advanced control system designed for a seamless and gradual integration into the existing distributed control system is proposed
- 1 January 2006
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 39 (19) , 63-68
ADVANCED CONTROL BASED ON FUZZY MODEL
- 1 January 2006
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 39 (19) , 63-68
ADVANCED CONTROL BASED ON FUZZY MODEL
- 1 January 2006
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 39 (19) , 99-104
MODEL-BASED FAULT DETECTION AND ISOLATION OF THERMAL PROCESSES
- 1 January 2006
- Published by Elsevier in IFAC Proceedings Volumes
- Vol. 39 (19) , 99-104