OUO. Unverdi

O. Unverdi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


O. Unverdi has a total of 9 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    A computational framework for post-acquisition stability assessment in scanning tunneling microscopy

    by D Gemici Deveci, Ö Ünverdi, F N Yıldırım, H Ö Özer

    In high-precision scanning-based measurement systems, the reliability of data obtained at the atomic scale may be limited by hardware-induced geometric instabilities and operator-dependent interpretation processes. In particular, in artificial intelligence-based surface characterization, the lack of quantitative verification of measurement stability increases the risk of error propagation in subsequent analysis and modeling stages. In this study, a modular, traceable, and hybrid computational framework is presented for quantitative and comparative post-acquisition stability assessment in atomic-resolution STM measurements. The proposed approach combines deterministic computer vision-based analyses with modern deep learning components in a hybrid workflow, producing pixel-level drift metrics together with local and surface-level image-similarity indicators based on the structural similarity index measure and normalized cross-correlation. Going beyond conventional drift-correction-oriented approaches, the study puts forward the concept of ‘drift-aware data reliability’ as a systematic framework for post-acquisition measurement stability assessment. The resulting quantitative outputs make the stability profile of the measurement system visible and provide a quantitative and traceable basis for assessing the usability of the data in subsequent analysis, interpretation, and modeling processes.

  • A drift‐aware framework for reliability assessment and image‐based interpretation of atomic force microscopy measurements

    by D. Gemici Deveci, Ö. Ünverdi, B. Yenen, S. N. Sönmez, H. Ö. Özer

    Drift is one of the primary sources of uncertainty limiting the accuracy, repeatability, and reliability of scanning probe microscopy (SPM) measurements, with a particularly significant effect on the comparison of consecutive surface topography images. In this study, a two‐module hybrid physical–computational framework is presented for the drift‐aware interpretation and reliability assessment of consecutive AFM topography measurements. The first module integrates deep learning (DL)‐based inter‐frame correspondence extraction, geometric validation, physical coordinate reconstruction, scan‐order‐based acquisition‐time assignment, inter‐scan delay correction, and temperature synchronisation to generate a time‐labelled drift representation. The second module uses this structured representation for comparative data‐driven modelling and evaluates drift velocity (), model performance, and stability through temperature‐included and temperature‐excluded configurations. This structure enables the joint analysis of validated correspondences in terms of lateral displacement, relative height variation, acquisition time, , drift direction, and synchronously recorded ambient temperature, together with their physical coordinate labels. The results indicate that the proposed framework should be positioned not as a universal drift‐correction method, but as a complementary and modular analysis approach that supports the drift‐aware interpretation, comparison, and reliability assessment of consecutive AFM topography measurements.

  • Graphene/SOI-based self-powered Schottky barrier photodiode array

    by A. Yanilmaz, M. Fidan, O. Unverdi, C. Çelebi

    We have fabricated a four-element graphene/silicon on insulator (SOI) based Schottky barrier photodiode array (PDA) and investigated its optoelectronic device performance. In our device design, monolayer graphene is utilized as a common electrode on a lithographically defined linear array of n-type Si channels on a SOI substrate. As revealed by wavelength resolved photocurrent spectroscopy measurements, each element in the PDA structure exhibited a maximum spectral responsivity of around 0.1 A/W under a self-powered operational mode. Time-dependent photocurrent spectroscopy measurements showed excellent photocurrent reversibility of the device with ∼1.36 and ∼1.27 μs rise time and fall time, respectively. Each element in the array displayed an average specific detectivity of around 1.3 × 1012 Jones and a substantially small noise equivalent power of ∼0.14 pW/Hz−1/2. The study presented here is expected to offer exciting opportunities in terms of high value-added graphene/Si based PDA device applications such as multi-wavelength light measurement, level metering, high-speed photometry, and position/motion detection.