Antonella Maria De Corato
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Antonella Maria De Corato has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Pierluigi Mancarella
The University of Melbourne, Parkville, VIC, Australia
4 shared publications - Mehdi Ghazavi Dozein
Monash University
2 shared publications - Shariq Riaz
School of Electrical and Information Engineering, The University of Sydney, Sydney, New South Wales, Australia
2 shared publications - Eduardo Alejandro Martinez Cesena
University of Manchester
1 shared publication - Isam Saedi
Univ Melbourne, Dept Elect & Elect Engn, Melbourne, Australia
1 shared publication - Kai Wu
Center of Nanomaterials for Renewable Energy State Key Laboratory of Electrical Insulation and Power Equipment Xi'an Jiaotong University Xi'an P. R. China
1 shared publication
Latest Publications
- 5 November 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 93, 650-667
Day-ahead multi-energy optimisation considering hydrogen blending and integrated electricity-heat-gas networks
- 5 November 2024
- Published by Elsevier in International Journal of Hydrogen Energy
- Vol. 93, 650-667
Day-ahead multi-energy optimisation considering hydrogen blending and integrated electricity-heat-gas networks
- 15 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4312-4323
Hydrogen Electrolyzer Load Modelling for Steady-State Power System Studies
This work introduces a comprehensive hydrogen electrolyzer (HE) load modelling framework suitable for general steady-state power system studies such as power flow and optimal power flow. The proposed model captures all relevant nonlinear physical features and operational constraints of the electrolysis stack and downstream hydrogen (H 2 ) system. More specifically, the modelling includes HE active power consumption as a function of hydrogen production and variable stack efficiency, physical and operation impact and limits of its power electronic converter (PEC), HE reactive power capability, PEC power transfer limits, minimum stable power consumption, ramping capabilities, H 2 demand, and a technology-agnostic model of H 2 storage considering multiple storage types. The features of the proposed modelling framework and their importance are showcased, both at device-level as well as in the context of power system studies, via two applications to the power flow and optimal power flow problems.
- 15 September 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Delivery
- Vol. 38 (6) , 4312-4323
Hydrogen Electrolyzer Load Modelling for Steady-State Power System Studies
This work introduces a comprehensive hydrogen electrolyzer (HE) load modelling framework suitable for general steady-state power system studies such as power flow and optimal power flow. The proposed model captures all relevant nonlinear physical features and operational constraints of the electrolysis stack and downstream hydrogen (H 2 ) system. More specifically, the modelling includes HE active power consumption as a function of hydrogen production and variable stack efficiency, physical and operation impact and limits of its power electronic converter (PEC), HE reactive power capability, PEC power transfer limits, minimum stable power consumption, ramping capabilities, H 2 demand, and a technology-agnostic model of H 2 storage considering multiple storage types. The features of the proposed modelling framework and their importance are showcased, both at device-level as well as in the context of power system studies, via two applications to the power flow and optimal power flow problems.
- Top Cited Papers
- 10 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (3) , 2447-2459
Virtual Inertia Response and Frequency Control Ancillary Services From Hydrogen Electrolyzers
This paper presents the modeling foundations to study the capabilities of hydrogen electrolyzers (HEs) to provide frequency control ancillary services (FCAS), including virtual inertia and primary and secondary frequency response. To do so, we propose a general, unified HE dynamic model for the electrolyzer stack circuit, power-electronics interface (PEI), and relevant converter-level control loops. The equivalent circuit of the stack is derived from its current transfer function, with poles and zero obtained from its step response characteristics (e.g., rise/settling time). The stack model also considers relevant physical nonlinearities and downstream hydrogen buffer/process operational constraints. The PEI control loops account for stack model parameters, hydrogen production operational constraints, stack temperature dynamics, and active power reference generation strategy for contingency and regulation frequency support services. Further, we propose a virtual synchronous machine (VSM) control approach to study the VSM HE capabilities to also provide virtual inertia response. We apply the modeling to both alkaline and proton exchange membrane (PEM) technologies, including design of appropriate control schemes. Finally, we assess the FCAS performance of alkaline and PEM HEs via dynamic simulation of the Australian south-east interconnection in a 50%-renewable scenario, also discussing comparison and cooperation with battery energy storage systems.
- 10 June 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Systems
- Vol. 38 (3) , 2447-2459
Top Cited PapersVirtual Inertia Response and Frequency Control Ancillary Services From Hydrogen Electrolyzers
This paper presents the modeling foundations to study the capabilities of hydrogen electrolyzers (HEs) to provide frequency control ancillary services (FCAS), including virtual inertia and primary and secondary frequency response. To do so, we propose a general, unified HE dynamic model for the electrolyzer stack circuit, power-electronics interface (PEI), and relevant converter-level control loops. The equivalent circuit of the stack is derived from its current transfer function, with poles and zero obtained from its step response characteristics (e.g., rise/settling time). The stack model also considers relevant physical nonlinearities and downstream hydrogen buffer/process operational constraints. The PEI control loops account for stack model parameters, hydrogen production operational constraints, stack temperature dynamics, and active power reference generation strategy for contingency and regulation frequency support services. Further, we propose a virtual synchronous machine (VSM) control approach to study the VSM HE capabilities to also provide virtual inertia response. We apply the modeling to both alkaline and proton exchange membrane (PEM) technologies, including design of appropriate control schemes. Finally, we assess the FCAS performance of alkaline and PEM HEs via dynamic simulation of the Australian south-east interconnection in a 50%-renewable scenario, also discussing comparison and cooperation with battery energy storage systems.
- 5 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Assessing the Flexibility of Electricity-Gas-Hydrogen Distribution Systems with P2G Units
The future low-carbon power system requires additional flexibility to accommodate the increasing share of intermittent renewable energy sources (RES). Electrolyzers with fast dynamic characteristics are in the spotlight as emerging candidate to provide the much-needed operational flexibility. In particular, hydrogen electrolyzers can convert excess renewable energy into “green hydrogen”, which can then be injected in the gas network. Given this, the presented work first quantifies the impact of gas network constraints on the operation of an electrolyzer. Second, we systematically analyse the flexibility of an electricity-gas-hydrogen system, operated under a VPP-based aggregation setup. The proposed methodology is tested considering real electricity and gas distribution networks. The results highlight the impact of gas network limits on the flexibility potential of an electrolyzer that can be made available to the electrical network.
- 5 December 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1-5
Assessing the Flexibility of Electricity-Gas-Hydrogen Distribution Systems with P2G Units
The future low-carbon power system requires additional flexibility to accommodate the increasing share of intermittent renewable energy sources (RES). Electrolyzers with fast dynamic characteristics are in the spotlight as emerging candidate to provide the much-needed operational flexibility. In particular, hydrogen electrolyzers can convert excess renewable energy into “green hydrogen”, which can then be injected in the gas network. Given this, the presented work first quantifies the impact of gas network constraints on the operation of an electrolyzer. Second, we systematically analyse the flexibility of an electricity-gas-hydrogen system, operated under a VPP-based aggregation setup. The proposed methodology is tested considering real electricity and gas distribution networks. The results highlight the impact of gas network limits on the flexibility potential of an electrolyzer that can be made available to the electrical network.