Jaycee Kaufman
Research Subjects
Research Interests
Jaycee Kaufman has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Yan Fossat
Klick Applied Sciences, Klick Health, Toronto, ON, Canada
12 shared publications - Jessica Oreskovic
Klick Labs Toronto, ON Canada
8 shared publications - Anirudh Thommandram
Klick Applied Sciences, Klick Health, Toronto, ON, Canada
4 shared publications - Nikhil Valsan Kulangareth
Klick Labs Toronto, ON Canada
2 shared publications Yan Fossat
Klick Labs, Klick Inc., Toronto, Canada
2 shared publications- Andrew D. S. Cameron
Department of Biology, University of Regina
1 shared publication
Latest Publications
- Open Access
- 26 June 2025
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 10 (1) , e64357
Optimizing Voice Sample Quantity and Recording Settings for the Prediction of Type 2 Diabetes Mellitus: Retrospective Study
Background: The use of acoustic biomarkers derived from speech signals is a promising non-invasive technique for diagnosing type 2 diabetes mellitus (T2DM). Despite its potential, there remains a critical gap in knowledge regarding the optimal number of voice recordings and recording schedule necessary to achieve effective diagnostic accuracy. Objective: This study aimed to determine the optimal number of voice samples and the ideal recording schedule (frequency and timing), required to maintain the T2DM diagnostic efficacy while reducing patient burden. Methods: We analyzed voice recordings from 78 adults (22 women), including 39 individuals diagnosed with T2DM. Participants had a mean (SD) age of 45.26 (10.63) years and mean (SD) BMI of 28.07 (4.59) kg/m². In total, 5035 voice recordings were collected, with a mean (SD) of 4.91 (1.45) recordings per day; higher adherence was observed among women (5.13 [1.38] vs 4.82 [1.46] in men). We evaluated the diagnostic accuracy of a previously developed voice-based model under different recording conditions. Segmented linear regression analysis was used to assess model accuracy across varying numbers of voice recordings, and the Kendall tau correlation was used to measure the relationship between recording settings and accuracy. A significance threshold of P<.05 was applied. Results: Our results showed that including up to 6 voice recordings notably improved the model accuracy for T2DM compared to using only one recording, with accuracy increasing from 59.61 to 65.02 for men and from 65.55 to 69.43 for women. Additionally, the day on which voice recordings were collected did not significantly affect model accuracy (P>.05). However, adhering to recording within a single day demonstrated higher accuracy, with accuracy of 73.95% for women and 85.48% for men when all recordings were from the first and second days. Conclusions: This study underscores the optimal voice recording settings to reduce patient burden while maintaining diagnostic efficacy.
- 26 June 2025
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 10 (1) , e64357
Open AccessOptimizing Voice Sample Quantity and Recording Settings for the Prediction of Type 2 Diabetes Mellitus: Retrospective Study
Background: The use of acoustic biomarkers derived from speech signals is a promising non-invasive technique for diagnosing type 2 diabetes mellitus (T2DM). Despite its potential, there remains a critical gap in knowledge regarding the optimal number of voice recordings and recording schedule necessary to achieve effective diagnostic accuracy. Objective: This study aimed to determine the optimal number of voice samples and the ideal recording schedule (frequency and timing), required to maintain the T2DM diagnostic efficacy while reducing patient burden. Methods: We analyzed voice recordings from 78 adults (22 women), including 39 individuals diagnosed with T2DM. Participants had a mean (SD) age of 45.26 (10.63) years and mean (SD) BMI of 28.07 (4.59) kg/m². In total, 5035 voice recordings were collected, with a mean (SD) of 4.91 (1.45) recordings per day; higher adherence was observed among women (5.13 [1.38] vs 4.82 [1.46] in men). We evaluated the diagnostic accuracy of a previously developed voice-based model under different recording conditions. Segmented linear regression analysis was used to assess model accuracy across varying numbers of voice recordings, and the Kendall tau correlation was used to measure the relationship between recording settings and accuracy. A significance threshold of P<.05 was applied. Results: Our results showed that including up to 6 voice recordings notably improved the model accuracy for T2DM compared to using only one recording, with accuracy increasing from 59.61 to 65.02 for men and from 65.55 to 69.43 for women. Additionally, the day on which voice recordings were collected did not significantly affect model accuracy (P>.05). However, adhering to recording within a single day demonstrated higher accuracy, with accuracy of 73.95% for women and 85.48% for men when all recordings were from the first and second days. Conclusions: This study underscores the optimal voice recording settings to reduce patient burden while maintaining diagnostic efficacy.
- Open Access
- 9 January 2025
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 9 (1) , e65448
Longitudinal Changes in Pitch-Related Acoustic Characteristics of the Voice Throughout the Menstrual Cycle: Observational Study
Background: Identifying subtle changes in the menstrual cycle is crucial for effective fertility tracking and understanding reproductive health. Objective: The aim of the study is to explore how fundamental frequency features vary between menstrual phases using daily voice recordings. Methods: This study analyzed smartphone-collected voice recordings from 16 naturally cycling female participants, collected every day for 1 full menstrual cycle. Fundamental frequency features (mean, SD, 5th percentile, and 95th percentile) were extracted from each voice recording. Ovulation was estimated using luteinizing hormone urine tests taken every morning. The analysis included comparisons of these features between the follicular and luteal phases and the application of changepoint detection algorithms to assess changes and pinpoint the day in which the shifts in vocal pitch occur. Results: The fundamental frequency SD was 9.0% (SD 2.9%) lower in the luteal phase compared to the follicular phase (95% CI 3.4%‐14.7%; P=.002), and the 5th percentile of the fundamental frequency was 8.8% (SD 3.6%) higher (95% CI 1.7%‐16.0%; P=.01). No significant differences were found between phases in mean fundamental frequency or the 95th percentile of the fundamental frequency (P=.65 and P=.07). Changepoint detection, applied separately to each feature, identified the point in time when vocal frequency behaviors shifted. For the fundamental frequency SD and 5th percentile, 81% (n=13) of participants exhibited shifts within the fertile window (P=.03). In comparison, only 63% (n=10; P=.24) and 50% (n=8; P=.50) of participants had shifts in the fertile window for the mean and 95th percentile of the fundamental frequency, respectively. Conclusions: These findings indicate that subtle variations in vocal pitch may reflect changes associated with the menstrual cycle, suggesting the potential for developing a noninvasive and convenient method for monitoring reproductive health. Changepoint detection may provide a promising avenue for future work in longitudinal fertility analysis.
- 9 January 2025
- Published by JMIR Publications Inc. in JMIR Formative Research
- Vol. 9 (1) , e65448
Open AccessLongitudinal Changes in Pitch-Related Acoustic Characteristics of the Voice Throughout the Menstrual Cycle: Observational Study
Background: Identifying subtle changes in the menstrual cycle is crucial for effective fertility tracking and understanding reproductive health. Objective: The aim of the study is to explore how fundamental frequency features vary between menstrual phases using daily voice recordings. Methods: This study analyzed smartphone-collected voice recordings from 16 naturally cycling female participants, collected every day for 1 full menstrual cycle. Fundamental frequency features (mean, SD, 5th percentile, and 95th percentile) were extracted from each voice recording. Ovulation was estimated using luteinizing hormone urine tests taken every morning. The analysis included comparisons of these features between the follicular and luteal phases and the application of changepoint detection algorithms to assess changes and pinpoint the day in which the shifts in vocal pitch occur. Results: The fundamental frequency SD was 9.0% (SD 2.9%) lower in the luteal phase compared to the follicular phase (95% CI 3.4%‐14.7%; P=.002), and the 5th percentile of the fundamental frequency was 8.8% (SD 3.6%) higher (95% CI 1.7%‐16.0%; P=.01). No significant differences were found between phases in mean fundamental frequency or the 95th percentile of the fundamental frequency (P=.65 and P=.07). Changepoint detection, applied separately to each feature, identified the point in time when vocal frequency behaviors shifted. For the fundamental frequency SD and 5th percentile, 81% (n=13) of participants exhibited shifts within the fertile window (P=.03). In comparison, only 63% (n=10; P=.24) and 50% (n=8; P=.50) of participants had shifts in the fertile window for the mean and 95th percentile of the fundamental frequency, respectively. Conclusions: These findings indicate that subtle variations in vocal pitch may reflect changes associated with the menstrual cycle, suggesting the potential for developing a noninvasive and convenient method for monitoring reproductive health. Changepoint detection may provide a promising avenue for future work in longitudinal fertility analysis.
- Open Access
- 2 January 2025
- Published by Oxford University Press (OUP) in The ISME Journal
- Vol. 19 (1)
Lysis of Escherichia coli by colicin Ib contributes to bacterial cross-feeding by releasing active β-galactosidase
The diffusible toxin ColIb produced by Salmonella enterica serovar Typhimurium SL1344 is a potent inhibitor of Escherichia coli growth. To identify and parameterize metabolic cross-feeding in states of competition, we established defined communities in which E. coli was the only species able to access a sole carbon source, lactose. Although ColIb was predicted to undermine cross-feeding by killing the lactose-converting E. coli, S. enterica populations thrived in co-culture. We discovered that ColIb caused the release of active β-galactosidase from E. coli cells, which induced galactose uptake by S. enterica. Although iron limitation stimulates ColIb production and makes E. coli more sensitive to the toxin, ColIb killing in iron-limited conditions did not enhance iron acquisition or siderophore scavenging by S. enterica. Also unexpected was the rapid rate at which resistance to ColIb evolved in E. coli through spontaneous mutation of the ColIb receptor gene cirA or horizontal acquisition of the S. enterica colicin immunity gene imm. Mathematical modelling effectively predicted the growth kinetics of E. coli and S. enterica populations, revealing a tractable system in which ColIb can shrink a competitor population while simultaneously amplifying the metabolic contributions of the suppressed population.
- 2 January 2025
- Published by Oxford University Press (OUP) in The ISME Journal
- Vol. 19 (1)
Open AccessLysis of Escherichia coli by colicin Ib contributes to bacterial cross-feeding by releasing active β-galactosidase
The diffusible toxin ColIb produced by Salmonella enterica serovar Typhimurium SL1344 is a potent inhibitor of Escherichia coli growth. To identify and parameterize metabolic cross-feeding in states of competition, we established defined communities in which E. coli was the only species able to access a sole carbon source, lactose. Although ColIb was predicted to undermine cross-feeding by killing the lactose-converting E. coli, S. enterica populations thrived in co-culture. We discovered that ColIb caused the release of active β-galactosidase from E. coli cells, which induced galactose uptake by S. enterica. Although iron limitation stimulates ColIb production and makes E. coli more sensitive to the toxin, ColIb killing in iron-limited conditions did not enhance iron acquisition or siderophore scavenging by S. enterica. Also unexpected was the rapid rate at which resistance to ColIb evolved in E. coli through spontaneous mutation of the ColIb receptor gene cirA or horizontal acquisition of the S. enterica colicin immunity gene imm. Mathematical modelling effectively predicted the growth kinetics of E. coli and S. enterica populations, revealing a tractable system in which ColIb can shrink a competitor population while simultaneously amplifying the metabolic contributions of the suppressed population.
- Open Access
- 9 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 123621-123629
Machine Learning-Enabled Hypertension Screening Through Acoustical Speech Analysis: Model Development and Validation
Hypertension, referred to as the “silent killer” by the World Health Organization, affects over 35% of the global population. Early diagnosis and behavioural interventions have been shown to mitigate morbidity and mortality associated with this condition. However, conventional methods of measuring blood pressure and accordingly identifying hypertension, such as sphygmomanometry, require technical expertise and may not be readily accessible, particularly in remote or underserved areas. Automatic blood pressure measurement devices offer an alternative but are often inaccessible in certain populations. In this study, we propose a novel framework for detecting hypertension through acoustic analysis of speech. By recording speech across multiple sessions and analyzing its temporal and spectral characteristics, we aim to identify indicators of hypertension. We explore two thresholds for labeling individuals with hypertension: 1) systolic blood pressure (SBP) $\geq 135$ mmHg or diastolic blood pressure (DBP) $\geq 85$ mmHg and 2) SBP $\geq 140$ mmHg or DBP $\geq 90$ mmHg. Our study involved 245 participants, including 91 females. We developed predictive models for each gender and assessed their performance using leave-one-subject-out validation. For the first threshold, the balanced accuracy achieved was 84% for females and 77% for males. For the second threshold, the corresponding balanced accuracies were 63% for females and 86% for males. These results demonstrate the potential of utilizing speech-based representations for non-invasive screening of hypertension.
- 9 September 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Access
- Vol. 12, 123621-123629
Open AccessMachine Learning-Enabled Hypertension Screening Through Acoustical Speech Analysis: Model Development and Validation
Hypertension, referred to as the “silent killer” by the World Health Organization, affects over 35% of the global population. Early diagnosis and behavioural interventions have been shown to mitigate morbidity and mortality associated with this condition. However, conventional methods of measuring blood pressure and accordingly identifying hypertension, such as sphygmomanometry, require technical expertise and may not be readily accessible, particularly in remote or underserved areas. Automatic blood pressure measurement devices offer an alternative but are often inaccessible in certain populations. In this study, we propose a novel framework for detecting hypertension through acoustic analysis of speech. By recording speech across multiple sessions and analyzing its temporal and spectral characteristics, we aim to identify indicators of hypertension. We explore two thresholds for labeling individuals with hypertension: 1) systolic blood pressure (SBP) $\geq 135$ mmHg or diastolic blood pressure (DBP) $\geq 85$ mmHg and 2) SBP $\geq 140$ mmHg or DBP $\geq 90$ mmHg. Our study involved 245 participants, including 91 females. We developed predictive models for each gender and assessed their performance using leave-one-subject-out validation. For the first threshold, the balanced accuracy achieved was 84% for females and 77% for males. For the second threshold, the corresponding balanced accuracies were 63% for females and 86% for males. These results demonstrate the potential of utilizing speech-based representations for non-invasive screening of hypertension.
- Open Access
- 28 August 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-9
Linear effects of glucose levels on voice fundamental frequency in type 2 diabetes and individuals with normoglycemia
Glucose levels in the body have been hypothesized to affect voice characteristics. One of the primary justifications for voice changes are due to Hooke’s law, in which a variation in the tension, mass, or length of the vocal folds, mediated by the body’s glucose levels, results in an alteration in their vibrational frequency. To explore this hypothesis, 505 participants were fitted with a continuous glucose monitor (CGM) and instructed to record their voice using a custom mobile application up to six times daily for 2 weeks. Glucose values from CGM were paired to voice recordings to create a sampled dataset that closely resembled the glucose profile of the comprehensive CGM dataset. Glucose levels and fundamental frequency (F0) had a significant positive association within an individual, and a 1 mg/dL increase in CGM recorded glucose corresponded to a 0.02 Hz increase in F0 (CI 0.01–0.03 Hz, P < 0.001). This effect was also observed when the participants were split into non-diabetic, prediabetic, and Type 2 Diabetic classifications (P = 0.03, P = 0.01, & P = 0.01 respectively). Vocal F0 increased with blood glucose levels, but future predictive models of glucose levels based on voice may need to be personalized due to high intraclass correlation.
- 28 August 2024
- Published by Springer Nature in Scientific Reports
- Vol. 14 (1) , 1-9
Open AccessLinear effects of glucose levels on voice fundamental frequency in type 2 diabetes and individuals with normoglycemia
Glucose levels in the body have been hypothesized to affect voice characteristics. One of the primary justifications for voice changes are due to Hooke’s law, in which a variation in the tension, mass, or length of the vocal folds, mediated by the body’s glucose levels, results in an alteration in their vibrational frequency. To explore this hypothesis, 505 participants were fitted with a continuous glucose monitor (CGM) and instructed to record their voice using a custom mobile application up to six times daily for 2 weeks. Glucose values from CGM were paired to voice recordings to create a sampled dataset that closely resembled the glucose profile of the comprehensive CGM dataset. Glucose levels and fundamental frequency (F0) had a significant positive association within an individual, and a 1 mg/dL increase in CGM recorded glucose corresponded to a 0.02 Hz increase in F0 (CI 0.01–0.03 Hz, P < 0.001). This effect was also observed when the participants were split into non-diabetic, prediabetic, and Type 2 Diabetic classifications (P = 0.03, P = 0.01, & P = 0.01 respectively). Vocal F0 increased with blood glucose levels, but future predictive models of glucose levels based on voice may need to be personalized due to high intraclass correlation.
- Open Access
- 15 April 2024
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 9, e56246
Impact of Audio Data Compression on Feature Extraction for Vocal Biomarker Detection: Validation Study
Background: Vocal biomarkers, derived from acoustic analysis of vocal characteristics, offer noninvasive avenues for medical screening, diagnostics, and monitoring. Previous research demonstrated the feasibility of predicting type 2 diabetes mellitus through acoustic analysis of smartphone-recorded speech. Building upon this work, this study explores the impact of audio data compression on acoustic vocal biomarker development, which is critical for broader applicability in health care. Objective: The objective of this research is to analyze how common audio compression algorithms (MP3, M4A, and WMA) applied by 3 different conversion tools at 2 bitrates affect features crucial for vocal biomarker detection. Methods: The impact of audio data compression on acoustic vocal biomarker development was investigated using uncompressed voice samples converted into MP3, M4A, and WMA formats at 2 bitrates (320 and 128 kbps) with MediaHuman (MH) Audio Converter, WonderShare (WS) UniConverter, and Fast Forward Moving Picture Experts Group (FFmpeg). The data set comprised recordings from 505 participants, totaling 17,298 audio files, collected using a smartphone. Participants recorded a fixed English sentence up to 6 times daily for up to 14 days. Feature extraction, including pitch, jitter, intensity, and Mel-frequency cepstral coefficients (MFCCs), was conducted using Python and Parselmouth. The Wilcoxon signed rank test and the Bonferroni correction for multiple comparisons were used for statistical analysis. Results: In this study, 36,970 audio files were initially recorded from 505 participants, with 17,298 recordings meeting the fixed sentence criteria after screening. Differences between the audio conversion software, MH, WS, and FFmpeg, were notable, impacting compression outcomes such as constant or variable bitrates. Analysis encompassed diverse data compression formats and a wide array of voice features and MFCCs. Wilcoxon signed rank tests yielded P values, with those below the Bonferroni-corrected significance level indicating significant alterations due to compression. The results indicated feature-specific impacts of compression across formats and bitrates. MH-converted files exhibited greater resilience compared to WS-converted files. Bitrate also influenced feature stability, with 38 cases affected uniquely by a single bitrate. Notably, voice features showed greater stability than MFCCs across conversion methods. Conclusions: Compression effects were found to be feature specific, with MH and FFmpeg showing greater resilience. Some features were consistently affected, emphasizing the importance of understanding feature resilience for diagnostic applications. Considering the implementation of vocal biomarkers in health care, finding features that remain consistent through compression for data storage or transmission purposes is valuable. Focused on specific features and formats, future research could broaden the scope to include diverse features, real-time compression algorithms, and various recording methods. This study enhances our understanding of audio compression’s influence on voice features and MFCCs, providing insights for developing applications across fields. The research underscores the significance of feature stability in working with compressed audio data, laying a foundation for informed voice data use in evolving technological landscapes.
- 15 April 2024
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 9, e56246
Open AccessImpact of Audio Data Compression on Feature Extraction for Vocal Biomarker Detection: Validation Study
Background: Vocal biomarkers, derived from acoustic analysis of vocal characteristics, offer noninvasive avenues for medical screening, diagnostics, and monitoring. Previous research demonstrated the feasibility of predicting type 2 diabetes mellitus through acoustic analysis of smartphone-recorded speech. Building upon this work, this study explores the impact of audio data compression on acoustic vocal biomarker development, which is critical for broader applicability in health care. Objective: The objective of this research is to analyze how common audio compression algorithms (MP3, M4A, and WMA) applied by 3 different conversion tools at 2 bitrates affect features crucial for vocal biomarker detection. Methods: The impact of audio data compression on acoustic vocal biomarker development was investigated using uncompressed voice samples converted into MP3, M4A, and WMA formats at 2 bitrates (320 and 128 kbps) with MediaHuman (MH) Audio Converter, WonderShare (WS) UniConverter, and Fast Forward Moving Picture Experts Group (FFmpeg). The data set comprised recordings from 505 participants, totaling 17,298 audio files, collected using a smartphone. Participants recorded a fixed English sentence up to 6 times daily for up to 14 days. Feature extraction, including pitch, jitter, intensity, and Mel-frequency cepstral coefficients (MFCCs), was conducted using Python and Parselmouth. The Wilcoxon signed rank test and the Bonferroni correction for multiple comparisons were used for statistical analysis. Results: In this study, 36,970 audio files were initially recorded from 505 participants, with 17,298 recordings meeting the fixed sentence criteria after screening. Differences between the audio conversion software, MH, WS, and FFmpeg, were notable, impacting compression outcomes such as constant or variable bitrates. Analysis encompassed diverse data compression formats and a wide array of voice features and MFCCs. Wilcoxon signed rank tests yielded P values, with those below the Bonferroni-corrected significance level indicating significant alterations due to compression. The results indicated feature-specific impacts of compression across formats and bitrates. MH-converted files exhibited greater resilience compared to WS-converted files. Bitrate also influenced feature stability, with 38 cases affected uniquely by a single bitrate. Notably, voice features showed greater stability than MFCCs across conversion methods. Conclusions: Compression effects were found to be feature specific, with MH and FFmpeg showing greater resilience. Some features were consistently affected, emphasizing the importance of understanding feature resilience for diagnostic applications. Considering the implementation of vocal biomarkers in health care, finding features that remain consistent through compression for data storage or transmission purposes is valuable. Focused on specific features and formats, future research could broaden the scope to include diverse features, real-time compression algorithms, and various recording methods. This study enhances our understanding of audio compression’s influence on voice features and MFCCs, providing insights for developing applications across fields. The research underscores the significance of feature stability in working with compressed audio data, laying a foundation for informed voice data use in evolving technological landscapes.
- Open Access
- 21 March 2024
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 9, e56245
Investigation of Deepfake Voice Detection Using Speech Pause Patterns: Algorithm Development and Validation
Background: The digital era has witnessed an escalating dependence on digital platforms for news and information, coupled with the advent of “deepfake” technology. Deepfakes, leveraging deep learning models on extensive data sets of voice recordings and images, pose substantial threats to media authenticity, potentially leading to unethical misuse such as impersonation and the dissemination of false information. Objective: To counteract this challenge, this study aims to introduce the concept of innate biological processes to discern between authentic human voices and cloned voices. We propose that the presence or absence of certain perceptual features, such as pauses in speech, can effectively distinguish between cloned and authentic audio. Methods: A total of 49 adult participants representing diverse ethnic backgrounds and accents were recruited. Each participant contributed voice samples for the training of up to 3 distinct voice cloning text-to-speech models and 3 control paragraphs. Subsequently, the cloning models generated synthetic versions of the control paragraphs, resulting in a data set consisting of up to 9 cloned audio samples and 3 control samples per participant. We analyzed the speech pauses caused by biological actions such as respiration, swallowing, and cognitive processes. Five audio features corresponding to speech pause profiles were calculated. Differences between authentic and cloned audio for these features were assessed, and 5 classical machine learning algorithms were implemented using these features to create a prediction model. The generalization capability of the optimal model was evaluated through testing on unseen data, incorporating a model-naive generator, a model-naive paragraph, and model-naive participants. Results: Cloned audio exhibited significantly increased time between pauses (P<.001), decreased variation in speech segment length (P=.003), increased overall proportion of time speaking (P=.04), and decreased rates of micro- and macropauses in speech (both P=.01). Five machine learning models were implemented using these features, with the AdaBoost model demonstrating the highest performance, achieving a 5-fold cross-validation balanced accuracy of 0.81 (SD 0.05). Other models included support vector machine (balanced accuracy 0.79, SD 0.03), random forest (balanced accuracy 0.78, SD 0.04), logistic regression, and decision tree (balanced accuracies 0.76, SD 0.10 and 0.72, SD 0.06). When evaluating the optimal AdaBoost model, it achieved an overall test accuracy of 0.79 when predicting unseen data. Conclusions: The incorporation of perceptual, biological features into machine learning models demonstrates promising results in distinguishing between authentic human voices and cloned audio.
- 21 March 2024
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 9, e56245
Open AccessInvestigation of Deepfake Voice Detection Using Speech Pause Patterns: Algorithm Development and Validation
Background: The digital era has witnessed an escalating dependence on digital platforms for news and information, coupled with the advent of “deepfake” technology. Deepfakes, leveraging deep learning models on extensive data sets of voice recordings and images, pose substantial threats to media authenticity, potentially leading to unethical misuse such as impersonation and the dissemination of false information. Objective: To counteract this challenge, this study aims to introduce the concept of innate biological processes to discern between authentic human voices and cloned voices. We propose that the presence or absence of certain perceptual features, such as pauses in speech, can effectively distinguish between cloned and authentic audio. Methods: A total of 49 adult participants representing diverse ethnic backgrounds and accents were recruited. Each participant contributed voice samples for the training of up to 3 distinct voice cloning text-to-speech models and 3 control paragraphs. Subsequently, the cloning models generated synthetic versions of the control paragraphs, resulting in a data set consisting of up to 9 cloned audio samples and 3 control samples per participant. We analyzed the speech pauses caused by biological actions such as respiration, swallowing, and cognitive processes. Five audio features corresponding to speech pause profiles were calculated. Differences between authentic and cloned audio for these features were assessed, and 5 classical machine learning algorithms were implemented using these features to create a prediction model. The generalization capability of the optimal model was evaluated through testing on unseen data, incorporating a model-naive generator, a model-naive paragraph, and model-naive participants. Results: Cloned audio exhibited significantly increased time between pauses (P<.001), decreased variation in speech segment length (P=.003), increased overall proportion of time speaking (P=.04), and decreased rates of micro- and macropauses in speech (both P=.01). Five machine learning models were implemented using these features, with the AdaBoost model demonstrating the highest performance, achieving a 5-fold cross-validation balanced accuracy of 0.81 (SD 0.05). Other models included support vector machine (balanced accuracy 0.79, SD 0.03), random forest (balanced accuracy 0.78, SD 0.04), logistic regression, and decision tree (balanced accuracies 0.76, SD 0.10 and 0.72, SD 0.06). When evaluating the optimal AdaBoost model, it achieved an overall test accuracy of 0.79 when predicting unseen data. Conclusions: The incorporation of perceptual, biological features into machine learning models demonstrates promising results in distinguishing between authentic human voices and cloned audio.
- Open Access
- 16 January 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Investigation of Deepfake Voice Detection Using Speech Pause Patterns: Algorithm Development and Validation (Preprint)
BACKGROUND The digital era has witnessed an escalating dependence on digital platforms for news and information, coupled with the advent of “deepfake” technology. Deepfakes, leveraging deep learning models on extensive data sets of voice recordings and images, pose substantial threats to media authenticity, potentially leading to unethical misuse such as impersonation and the dissemination of false information. OBJECTIVE To counteract this challenge, this study aims to introduce the concept of innate biological processes to discern between authentic human voices and cloned voices. We propose that the presence or absence of certain perceptual features, such as pauses in speech, can effectively distinguish between cloned and authentic audio. METHODS A total of 49 adult participants representing diverse ethnic backgrounds and accents were recruited. Each participant contributed voice samples for the training of up to 3 distinct voice cloning text-to-speech models and 3 control paragraphs. Subsequently, the cloning models generated synthetic versions of the control paragraphs, resulting in a data set consisting of up to 9 cloned audio samples and 3 control samples per participant. We analyzed the speech pauses caused by biological actions such as respiration, swallowing, and cognitive processes. Five audio features corresponding to speech pause profiles were calculated. Differences between authentic and cloned audio for these features were assessed, and 5 classical machine learning algorithms were implemented using these features to create a prediction model. The generalization capability of the optimal model was evaluated through testing on unseen data, incorporating a model-naive generator, a model-naive paragraph, and model-naive participants. RESULTS Cloned audio exhibited significantly increased time between pauses (P<.001), decreased variation in speech segment length (P=.003), increased overall proportion of time speaking (P=.04), and decreased rates of micro- and macropauses in speech (both P=.01). Five machine learning models were implemented using these features, with the AdaBoost model demonstrating the highest performance, achieving a 5-fold cross-validation balanced accuracy of 0.81 (SD 0.05). Other models included support vector machine (balanced accuracy 0.79, SD 0.03), random forest (balanced accuracy 0.78, SD 0.04), logistic regression, and decision tree (balanced accuracies 0.76, SD 0.10 and 0.72, SD 0.06). When evaluating the optimal AdaBoost model, it achieved an overall test accuracy of 0.79 when predicting unseen data. CONCLUSIONS The incorporation of perceptual, biological features into machine learning models demonstrates promising results in distinguishing between authentic human voices and cloned audio.
- 16 January 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessInvestigation of Deepfake Voice Detection Using Speech Pause Patterns: Algorithm Development and Validation (Preprint)
BACKGROUND The digital era has witnessed an escalating dependence on digital platforms for news and information, coupled with the advent of “deepfake” technology. Deepfakes, leveraging deep learning models on extensive data sets of voice recordings and images, pose substantial threats to media authenticity, potentially leading to unethical misuse such as impersonation and the dissemination of false information. OBJECTIVE To counteract this challenge, this study aims to introduce the concept of innate biological processes to discern between authentic human voices and cloned voices. We propose that the presence or absence of certain perceptual features, such as pauses in speech, can effectively distinguish between cloned and authentic audio. METHODS A total of 49 adult participants representing diverse ethnic backgrounds and accents were recruited. Each participant contributed voice samples for the training of up to 3 distinct voice cloning text-to-speech models and 3 control paragraphs. Subsequently, the cloning models generated synthetic versions of the control paragraphs, resulting in a data set consisting of up to 9 cloned audio samples and 3 control samples per participant. We analyzed the speech pauses caused by biological actions such as respiration, swallowing, and cognitive processes. Five audio features corresponding to speech pause profiles were calculated. Differences between authentic and cloned audio for these features were assessed, and 5 classical machine learning algorithms were implemented using these features to create a prediction model. The generalization capability of the optimal model was evaluated through testing on unseen data, incorporating a model-naive generator, a model-naive paragraph, and model-naive participants. RESULTS Cloned audio exhibited significantly increased time between pauses (P<.001), decreased variation in speech segment length (P=.003), increased overall proportion of time speaking (P=.04), and decreased rates of micro- and macropauses in speech (both P=.01). Five machine learning models were implemented using these features, with the AdaBoost model demonstrating the highest performance, achieving a 5-fold cross-validation balanced accuracy of 0.81 (SD 0.05). Other models included support vector machine (balanced accuracy 0.79, SD 0.03), random forest (balanced accuracy 0.78, SD 0.04), logistic regression, and decision tree (balanced accuracies 0.76, SD 0.10 and 0.72, SD 0.06). When evaluating the optimal AdaBoost model, it achieved an overall test accuracy of 0.79 when predicting unseen data. CONCLUSIONS The incorporation of perceptual, biological features into machine learning models demonstrates promising results in distinguishing between authentic human voices and cloned audio.
- Open Access
- 10 January 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Impact of Audio Data Compression on Feature Extraction for Vocal Biomarker Detection: Validation Study (Preprint)
BACKGROUND Vocal biomarkers, derived from acoustic analysis of vocal characteristics, offer noninvasive avenues for medical screening, diagnostics, and monitoring. Previous research demonstrated the feasibility of predicting type 2 diabetes mellitus through acoustic analysis of smartphone-recorded speech. Building upon this work, this study explores the impact of audio data compression on acoustic vocal biomarker development, which is critical for broader applicability in health care. OBJECTIVE The objective of this research is to analyze how common audio compression algorithms (MP3, M4A, and WMA) applied by 3 different conversion tools at 2 bitrates affect features crucial for vocal biomarker detection. METHODS The impact of audio data compression on acoustic vocal biomarker development was investigated using uncompressed voice samples converted into MP3, M4A, and WMA formats at 2 bitrates (320 and 128 kbps) with MediaHuman (MH) Audio Converter, WonderShare (WS) UniConverter, and Fast Forward Moving Picture Experts Group (FFmpeg). The data set comprised recordings from 505 participants, totaling 17,298 audio files, collected using a smartphone. Participants recorded a fixed English sentence up to 6 times daily for up to 14 days. Feature extraction, including pitch, jitter, intensity, and Mel-frequency cepstral coefficients (MFCCs), was conducted using Python and Parselmouth. The Wilcoxon signed rank test and the Bonferroni correction for multiple comparisons were used for statistical analysis. RESULTS In this study, 36,970 audio files were initially recorded from 505 participants, with 17,298 recordings meeting the fixed sentence criteria after screening. Differences between the audio conversion software, MH, WS, and FFmpeg, were notable, impacting compression outcomes such as constant or variable bitrates. Analysis encompassed diverse data compression formats and a wide array of voice features and MFCCs. Wilcoxon signed rank tests yielded P values, with those below the Bonferroni-corrected significance level indicating significant alterations due to compression. The results indicated feature-specific impacts of compression across formats and bitrates. MH-converted files exhibited greater resilience compared to WS-converted files. Bitrate also influenced feature stability, with 38 cases affected uniquely by a single bitrate. Notably, voice features showed greater stability than MFCCs across conversion methods. CONCLUSIONS Compression effects were found to be feature specific, with MH and FFmpeg showing greater resilience. Some features were consistently affected, emphasizing the importance of understanding feature resilience for diagnostic applications. Considering the implementation of vocal biomarkers in health care, finding features that remain consistent through compression for data storage or transmission purposes is valuable. Focused on specific features and formats, future research could broaden the scope to include diverse features, real-time compression algorithms, and various recording methods. This study enhances our understanding of audio compression’s influence on voice features and MFCCs, providing insights for developing applications across fields. The research underscores the significance of feature stability in working with compressed audio data, laying a foundation for informed voice data use in evolving technological landscapes.
- 10 January 2024
- Published by JMIR Publications Inc. in JMIR Preprints
Open AccessImpact of Audio Data Compression on Feature Extraction for Vocal Biomarker Detection: Validation Study (Preprint)
BACKGROUND Vocal biomarkers, derived from acoustic analysis of vocal characteristics, offer noninvasive avenues for medical screening, diagnostics, and monitoring. Previous research demonstrated the feasibility of predicting type 2 diabetes mellitus through acoustic analysis of smartphone-recorded speech. Building upon this work, this study explores the impact of audio data compression on acoustic vocal biomarker development, which is critical for broader applicability in health care. OBJECTIVE The objective of this research is to analyze how common audio compression algorithms (MP3, M4A, and WMA) applied by 3 different conversion tools at 2 bitrates affect features crucial for vocal biomarker detection. METHODS The impact of audio data compression on acoustic vocal biomarker development was investigated using uncompressed voice samples converted into MP3, M4A, and WMA formats at 2 bitrates (320 and 128 kbps) with MediaHuman (MH) Audio Converter, WonderShare (WS) UniConverter, and Fast Forward Moving Picture Experts Group (FFmpeg). The data set comprised recordings from 505 participants, totaling 17,298 audio files, collected using a smartphone. Participants recorded a fixed English sentence up to 6 times daily for up to 14 days. Feature extraction, including pitch, jitter, intensity, and Mel-frequency cepstral coefficients (MFCCs), was conducted using Python and Parselmouth. The Wilcoxon signed rank test and the Bonferroni correction for multiple comparisons were used for statistical analysis. RESULTS In this study, 36,970 audio files were initially recorded from 505 participants, with 17,298 recordings meeting the fixed sentence criteria after screening. Differences between the audio conversion software, MH, WS, and FFmpeg, were notable, impacting compression outcomes such as constant or variable bitrates. Analysis encompassed diverse data compression formats and a wide array of voice features and MFCCs. Wilcoxon signed rank tests yielded P values, with those below the Bonferroni-corrected significance level indicating significant alterations due to compression. The results indicated feature-specific impacts of compression across formats and bitrates. MH-converted files exhibited greater resilience compared to WS-converted files. Bitrate also influenced feature stability, with 38 cases affected uniquely by a single bitrate. Notably, voice features showed greater stability than MFCCs across conversion methods. CONCLUSIONS Compression effects were found to be feature specific, with MH and FFmpeg showing greater resilience. Some features were consistently affected, emphasizing the importance of understanding feature resilience for diagnostic applications. Considering the implementation of vocal biomarkers in health care, finding features that remain consistent through compression for data storage or transmission purposes is valuable. Focused on specific features and formats, future research could broaden the scope to include diverse features, real-time compression algorithms, and various recording methods. This study enhances our understanding of audio compression’s influence on voice features and MFCCs, providing insights for developing applications across fields. The research underscores the significance of feature stability in working with compressed audio data, laying a foundation for informed voice data use in evolving technological landscapes.
- Open Access
- 24 October 2023
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 8, e51754
A Radar-Based Opioid Overdose Detection Device for Public Restrooms: Design, Development, and Evaluation Study
Background: The opioid epidemic is a growing crisis worldwide. While many interventions have been put in place to try to protect people from opioid overdoses, they typically rely on the person to take initiative in protecting themselves, requiring forethought, preparation, and action. Respiratory depression or arrest is the mechanism by which opioid overdoses become fatal, but it can be reversed with the timely administration of naloxone. Objective: In this study, we described the development and validation of an opioid overdose detection radar (ODR), specifically designed for use in public restroom stalls. In-laboratory testing was conducted to validate the noncontact, privacy-preserving device against a respiration belt and to determine the accuracy and reliability of the device. Methods: We used an ODR system with a high-frequency pulsed coherent radar sensor and a Raspberry Pi (Raspberry Pi Ltd), combining advanced technology with a compact and cost-effective setup to monitor respiration and detect opioid overdoses. To determine the optimal position for the ODR within the confined space of a restroom stall, iterative testing was conducted, considering the radar’s bounded capture area and the limitations imposed by the stall’s dimensions and layout. By adjusting the orientation of the ODR, we were able to identify the most effective placement where the device reliably tracked respiration in a number of expected positions. Experiments used a mock restroom stall setup that adhered to building code regulations, creating a controlled environment while maintaining the authenticity of a public restroom stall. By simulating different body positions commonly associated with opioid overdoses, the ODR’s ability to accurately track respiration in various scenarios was assessed. To determine the accuracy of the ODR, testing was performed using a respiration belt as a reference. The radar measurements were compared with those obtained from the belt in experiments where participants were seated upright and slumped over. Results: The results demonstrated favorable agreement between the radar and belt measurements, with an overall mean error in respiration cycle duration of 0.0072 (SD 0.54) seconds for all recorded respiration cycles (N=204). During the simulated overdose experiments where participants were slumped over, the ODR successfully tracked respiration with a mean period difference of 0.0091 (SD 0.62) seconds compared with the reference data. Conclusions: The findings suggest that the ODR has the potential to detect significant deviations in respiration patterns that may indicate an opioid overdose event. The success of the ODR in these experiments indicates the device should be further developed and implemented to enhance safety and emergency response measures in public restrooms. However, additional validation is required for unhealthy opioid-influenced respiratory patterns to guarantee the ODR’s effectiveness in real-world overdose situations.
- 24 October 2023
- Published by JMIR Publications Inc. in JMIR Biomedical Engineering
- Vol. 8, e51754
Open AccessA Radar-Based Opioid Overdose Detection Device for Public Restrooms: Design, Development, and Evaluation Study
Background: The opioid epidemic is a growing crisis worldwide. While many interventions have been put in place to try to protect people from opioid overdoses, they typically rely on the person to take initiative in protecting themselves, requiring forethought, preparation, and action. Respiratory depression or arrest is the mechanism by which opioid overdoses become fatal, but it can be reversed with the timely administration of naloxone. Objective: In this study, we described the development and validation of an opioid overdose detection radar (ODR), specifically designed for use in public restroom stalls. In-laboratory testing was conducted to validate the noncontact, privacy-preserving device against a respiration belt and to determine the accuracy and reliability of the device. Methods: We used an ODR system with a high-frequency pulsed coherent radar sensor and a Raspberry Pi (Raspberry Pi Ltd), combining advanced technology with a compact and cost-effective setup to monitor respiration and detect opioid overdoses. To determine the optimal position for the ODR within the confined space of a restroom stall, iterative testing was conducted, considering the radar’s bounded capture area and the limitations imposed by the stall’s dimensions and layout. By adjusting the orientation of the ODR, we were able to identify the most effective placement where the device reliably tracked respiration in a number of expected positions. Experiments used a mock restroom stall setup that adhered to building code regulations, creating a controlled environment while maintaining the authenticity of a public restroom stall. By simulating different body positions commonly associated with opioid overdoses, the ODR’s ability to accurately track respiration in various scenarios was assessed. To determine the accuracy of the ODR, testing was performed using a respiration belt as a reference. The radar measurements were compared with those obtained from the belt in experiments where participants were seated upright and slumped over. Results: The results demonstrated favorable agreement between the radar and belt measurements, with an overall mean error in respiration cycle duration of 0.0072 (SD 0.54) seconds for all recorded respiration cycles (N=204). During the simulated overdose experiments where participants were slumped over, the ODR successfully tracked respiration with a mean period difference of 0.0091 (SD 0.62) seconds compared with the reference data. Conclusions: The findings suggest that the ODR has the potential to detect significant deviations in respiration patterns that may indicate an opioid overdose event. The success of the ODR in these experiments indicates the device should be further developed and implemented to enhance safety and emergency response measures in public restrooms. However, additional validation is required for unhealthy opioid-influenced respiratory patterns to guarantee the ODR’s effectiveness in real-world overdose situations.