Luis Isaac Ramos
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Luis Isaac Ramos has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Mauricio Cambeiro
Department of Radiation Oncology, Clinica Universidad de Navarra, 28027 Madrid, Spain
8 shared publications - Javier Aristu
Department of Radiation Oncology, Clinica Universidad de Navarra, 28027 Madrid, Spain
7 shared publications Rafael Martínez-Monge
Department of Oncology, University of Navarre, Pamplona, Spain
5 shared publications- Rafael Martínez-Monge
Department of Radiation Oncology Cancer Center Clínica Universidad de Navarra (CCUN) Pamplona Spain
5 shared publications Matías Jurado
Department of Gynecology, Clínica Universidad de Navarra, University of Navarre, Pamplona, Navarre, Spain; Instituto de Investigación Sanitaria de Navarra (IDISNA), Pamplona, Navarre, Spain
4 shared publicationsAlicia Olarte
Department of Radiation Oncology, Clínica Universidad de Navarra, University of Navarre, Pamplona, Navarre, Spain; Instituto de Investigación Sanitaria de Navarra (IDISNA), Pamplona, Navarre, Spain
3 shared publications
Latest Publications
- Open Access
- 24 August 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (17) , 9126
Local Preirradiation of Infarcted Cardiac Tissue Substantially Enhances Cell Engraftment
The success of cell therapy for the treatment of myocardial infarction depends on finding novel approaches that can substantially implement the engraftment of the transplanted cells. In order to enhance cell engraftment, most studies have focused on the pretreatment of transplantable cells. Here we have considered an alternative approach that involves the preconditioning of infarcted heart tissue to reduce endogenous cell activity and thus provide an advantage to our exogenous cells. This treatment is routinely used in other tissues such as bone marrow and skeletal muscle to improve cell engraftment, but it has never been taken in cardiac tissue. To avoid long-term cardiotoxicity induced by full heart irradiation we developed a rat model of a catheter-based heart irradiation system to locally impact a delimited region of the infarcted cardiac tissue. As proof of concept, we transferred ZsGreen+ iPSCs in the infarcted heart, due to their ease of use and detection. We found a very significant increase in cell engraftment in preirradiated rats. In this study, we demonstrate for the first time that preconditioning the infarcted cardiac tissue with local irradiation can substantially enhance cell engraftment.
- 24 August 2021
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 22 (17) , 9126
Open AccessLocal Preirradiation of Infarcted Cardiac Tissue Substantially Enhances Cell Engraftment
The success of cell therapy for the treatment of myocardial infarction depends on finding novel approaches that can substantially implement the engraftment of the transplanted cells. In order to enhance cell engraftment, most studies have focused on the pretreatment of transplantable cells. Here we have considered an alternative approach that involves the preconditioning of infarcted heart tissue to reduce endogenous cell activity and thus provide an advantage to our exogenous cells. This treatment is routinely used in other tissues such as bone marrow and skeletal muscle to improve cell engraftment, but it has never been taken in cardiac tissue. To avoid long-term cardiotoxicity induced by full heart irradiation we developed a rat model of a catheter-based heart irradiation system to locally impact a delimited region of the infarcted cardiac tissue. As proof of concept, we transferred ZsGreen+ iPSCs in the infarcted heart, due to their ease of use and detection. We found a very significant increase in cell engraftment in preirradiated rats. In this study, we demonstrate for the first time that preconditioning the infarcted cardiac tissue with local irradiation can substantially enhance cell engraftment.
- 1 September 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (18) , N417-N427
Improving the gamma analysis comparison using an unbinned multivariate test
In this study, we present a new procedure for the comparison of two dose matrices by means of a statistical test. A statistical distance is proposed to decide whether the difference between the two matrices is statistically significant. This statistical test is based on the square difference between the experimental and expected gamma matrix results. The expected gamma matrix is calculated by simulating the measurement process. For comparison purposes, the significance level of the test was chosen to give the same statistical significance as 90% of gamma-pass rate. The performance of the statistical distance is checked against 53 VMAT. The power of the presented test was compared using simulations with the 90% gamma-pass rate criteria for two cases in which intentional errors are introduced. In both cases, the test is uniformly more powerful. According to the test, two of the measured plans have a significant difference with calculated matrices, although the gamma pass rate measured was always greater than 90%.
- 1 September 2017
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 62 (18) , N417-N427
Improving the gamma analysis comparison using an unbinned multivariate test
In this study, we present a new procedure for the comparison of two dose matrices by means of a statistical test. A statistical distance is proposed to decide whether the difference between the two matrices is statistically significant. This statistical test is based on the square difference between the experimental and expected gamma matrix results. The expected gamma matrix is calculated by simulating the measurement process. For comparison purposes, the significance level of the test was chosen to give the same statistical significance as 90% of gamma-pass rate. The performance of the statistical distance is checked against 53 VMAT. The power of the presented test was compared using simulations with the 90% gamma-pass rate criteria for two cases in which intentional errors are introduced. In both cases, the test is uniformly more powerful. According to the test, two of the measured plans have a significant difference with calculated matrices, although the gamma pass rate measured was always greater than 90%.
- 3 August 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (16) , 6266-6268
Reply to Comment on ‘A new method to measure electron density and effective atomic number using dual-energy CT images’
In this note, we would like to respond to the comments made by Professor Bouchard on our recent published work and clarify some aspects of it.
- 3 August 2016
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (16) , 6266-6268
Reply to Comment on ‘A new method to measure electron density and effective atomic number using dual-energy CT images’
In this note, we would like to respond to the comments made by Professor Bouchard on our recent published work and clarify some aspects of it.
- 1 August 2016
- Published by Elsevier in Physica Medica
- Vol. 32 (8) , 972-980
Polarized dosimetry method for Gafchromic EBT3
- 1 August 2016
- Published by Elsevier in Physica Medica
- Vol. 32 (8) , 972-980
Polarized dosimetry method for Gafchromic EBT3
- 9 December 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (1) , 265-279
A new method to measure electron density and effective atomic number using dual-energy CT images
The purpose of this work is to present a new method to extract the electron density ( ) and the effective atomic number ( Z eff ) from dual-energy CT images, based on a Karhunen-Loeve expansion (KLE) of the atomic cross section per electron. This method was used to calibrate a Siemens Definition CT using the CIRS phantom. The predicted electron density and effective atomic number using 80 kVp and 140 kVp were compared with a calibration phantom and an independent set of samples. The mean absolute deviations between the theoretical and calculated values for all the samples were 1.7 % ± 0.1 % for and 4.1 % ± 0.3 % for Z eff . Finally, these results were compared with other stoichiometric method. The application of the KLE to represent the atomic cross section per electron is a promising method for calculating and Z eff using dual-energy CT images.
- 9 December 2015
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 61 (1) , 265-279
A new method to measure electron density and effective atomic number using dual-energy CT images
The purpose of this work is to present a new method to extract the electron density ( ) and the effective atomic number ( Z eff ) from dual-energy CT images, based on a Karhunen-Loeve expansion (KLE) of the atomic cross section per electron. This method was used to calibrate a Siemens Definition CT using the CIRS phantom. The predicted electron density and effective atomic number using 80 kVp and 140 kVp were compared with a calibration phantom and an independent set of samples. The mean absolute deviations between the theoretical and calculated values for all the samples were 1.7 % ± 0.1 % for and 4.1 % ± 0.3 % for Z eff . Finally, these results were compared with other stoichiometric method. The application of the KLE to represent the atomic cross section per electron is a promising method for calculating and Z eff using dual-energy CT images.
- 1 July 2015
- Published by Elsevier in Brachytherapy
- Vol. 14 (4) , 565-570
Time to loading and locoregional control in perioperative high-dose-rate brachytherapy: The tumor bed effect revisited
- 1 July 2015
- Published by Elsevier in Brachytherapy
- Vol. 14 (4) , 565-570
Time to loading and locoregional control in perioperative high-dose-rate brachytherapy: The tumor bed effect revisited
- 1 November 2014
- Published by Elsevier in Brachytherapy
- Vol. 13 (6) , 591-596
Volume of high-dose regions and likelihood of locoregional control after perioperative high-dose-rate brachytherapy: Do hotter implants work better?
- 1 November 2014
- Published by Elsevier in Brachytherapy
- Vol. 13 (6) , 591-596
Volume of high-dose regions and likelihood of locoregional control after perioperative high-dose-rate brachytherapy: Do hotter implants work better?
- 1 October 2014
- Published by Wiley in Medical Physics
- Vol. 41 (10) , 107102
Response to “Comment on ‘A method for multichannel dosimetry with EBT3 radiochromic films’ ” [Med. Phys. 41, 062101 (10pp.) (2014)]
- 1 October 2014
- Published by Wiley in Medical Physics
- Vol. 41 (10) , 107102
Response to “Comment on ‘A method for multichannel dosimetry with EBT3 radiochromic films’ ” [Med. Phys. 41, 062101 (10pp.) (2014)]