Shang-Yen Wu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shang-Yen Wu has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Cheng-Jen Chiu
Department of Ophthalmology, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien 970, Taiwan
2 shared publications - Jen-Hung Wang
Department of Medical Research, Hualien Tzu Chi Hospital, Buddhist Tzu Chi Medical Foundation, Hualien, Taiwan
2 shared publications - Ti-Yen Cheng
School of Medicine, Tzu Chi University, Hualien 970, Taiwan
1 shared publication
Latest Publications
- Open Access
Clinical Safety and Performance of Ultra-High Dk Tisilfocon A Orthokeratology Lenses: A Prospective Multicenter Study
This prospective multicenter study evaluated the safety and clinical performance of ultra-high Dk (180 ISO/Fatt) Tisilfocon A orthokeratology (Ortho-K) lenses to treat myopia. We enrolled 67 participants aged 8–49 years with myopia up to 8.00 D. Participants were followed for 36 weeks to assess uncorrected visual acuity (UCVA), axial length (AL), and corneal endothelial cell density (ECD). From the first week, UCVA significantly improved and remained stable through week 36. AL elongation was statistically significant overall, driven primarily by age-appropriate physiological growth in younger participants; adults and individuals with high myopia showed no significant axial elongation. Safety evaluations showed high biocompatibility with no adverse events exceeding Grade 2 corneal staining. ECD remained stable after 36 weeks of lens wear, demonstrating that the ultra-high oxygen permeability of Tisilfocon A supports corneal health and prevents hypoxic stress during overnight wear. Overall, these findings suggest that ultra-high Dk Tisilfocon A Ortho-K lenses are a safe and effective clinical solution for myopia management across diverse patients, providing long-term corneal integrity and stable visual outcomes. ECD remained stable over the 36-week observation period, providing reassuring short- to mid-term evidence that the ultra-high oxygen permeability of Tisilfocon A may help limit hypoxic stress during overnight wear. Overall, these findings suggest that ultra-high Dk Tisilfocon A Ortho-K lenses are well tolerated and clinically effective across diverse patients during this period; however, in the absence of a concurrent control group and given the relatively short follow-up, these results should be regarded as preliminary, and longer-term controlled studies are needed to confirm the durability of axial length control and corneal endothelial safety.
Open AccessClinical Safety and Performance of Ultra-High Dk Tisilfocon A Orthokeratology Lenses: A Prospective Multicenter Study
This prospective multicenter study evaluated the safety and clinical performance of ultra-high Dk (180 ISO/Fatt) Tisilfocon A orthokeratology (Ortho-K) lenses to treat myopia. We enrolled 67 participants aged 8–49 years with myopia up to 8.00 D. Participants were followed for 36 weeks to assess uncorrected visual acuity (UCVA), axial length (AL), and corneal endothelial cell density (ECD). From the first week, UCVA significantly improved and remained stable through week 36. AL elongation was statistically significant overall, driven primarily by age-appropriate physiological growth in younger participants; adults and individuals with high myopia showed no significant axial elongation. Safety evaluations showed high biocompatibility with no adverse events exceeding Grade 2 corneal staining. ECD remained stable after 36 weeks of lens wear, demonstrating that the ultra-high oxygen permeability of Tisilfocon A supports corneal health and prevents hypoxic stress during overnight wear. Overall, these findings suggest that ultra-high Dk Tisilfocon A Ortho-K lenses are a safe and effective clinical solution for myopia management across diverse patients, providing long-term corneal integrity and stable visual outcomes. ECD remained stable over the 36-week observation period, providing reassuring short- to mid-term evidence that the ultra-high oxygen permeability of Tisilfocon A may help limit hypoxic stress during overnight wear. Overall, these findings suggest that ultra-high Dk Tisilfocon A Ortho-K lenses are well tolerated and clinically effective across diverse patients during this period; however, in the absence of a concurrent control group and given the relatively short follow-up, these results should be regarded as preliminary, and longer-term controlled studies are needed to confirm the durability of axial length control and corneal endothelial safety.
- Open Access
- 15 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (14) , 4126
Assessment of Satisfaction, Compliance and Side Effects among Long-Term Orthokeratology Wearers
Purpose: This study aims to assess the satisfaction, compliance, and side effects among the long-term orthokeratology (Ortho-K) users in a tertiary hospital in Taiwan and analyze the side effects and related risk factors. Methods: Children and their guardians were assessed using a structured and validated questionnaire inquiring about background information, wear and care behaviors, daily activities, satisfaction, and related concerns. Clinical information, including refractive data and side effects, was obtained through patient medical files. Results: Three hundred and five school-aged patients were enrolled, and the average age was 13.13 ± 3.39 years, with an average wearing period of 17.1 ± 8.1 months. Over 83% of the subjects had clear daytime vision all day, around 88% felt satisfied or very satisfied with the results, and 98% exhibited a willingness to continue wearing the Ortho-K lenses. Most guardians (83%) were pleased with the controlling effect of myopic progression. Initial spherical equivalent and regular cleaning of the lens protein significantly correlated with clear day vision. Wearing >6 days/week correlated with less risk of lens binding. Based on the questionnaire, the main reasons for using Ortho-K were effectiveness, safety, and practicality, while the major concerns were discomfort, harmful to the eyes, and no effect. Conclusion: With a comprehensive care program from practitioners and good compliance of users, Ortho-K could be the most effective and satisfactory option for myopic children in Taiwan.
- 15 July 2022
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 11 (14) , 4126
Open AccessAssessment of Satisfaction, Compliance and Side Effects among Long-Term Orthokeratology Wearers
Purpose: This study aims to assess the satisfaction, compliance, and side effects among the long-term orthokeratology (Ortho-K) users in a tertiary hospital in Taiwan and analyze the side effects and related risk factors. Methods: Children and their guardians were assessed using a structured and validated questionnaire inquiring about background information, wear and care behaviors, daily activities, satisfaction, and related concerns. Clinical information, including refractive data and side effects, was obtained through patient medical files. Results: Three hundred and five school-aged patients were enrolled, and the average age was 13.13 ± 3.39 years, with an average wearing period of 17.1 ± 8.1 months. Over 83% of the subjects had clear daytime vision all day, around 88% felt satisfied or very satisfied with the results, and 98% exhibited a willingness to continue wearing the Ortho-K lenses. Most guardians (83%) were pleased with the controlling effect of myopic progression. Initial spherical equivalent and regular cleaning of the lens protein significantly correlated with clear day vision. Wearing >6 days/week correlated with less risk of lens binding. Based on the questionnaire, the main reasons for using Ortho-K were effectiveness, safety, and practicality, while the major concerns were discomfort, harmful to the eyes, and no effect. Conclusion: With a comprehensive care program from practitioners and good compliance of users, Ortho-K could be the most effective and satisfactory option for myopic children in Taiwan.