Bowen Zhao
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Bowen Zhao has a total of 91 co-authors. Here are the top co-authors by number of shared publications:
Ran Chen
Department of Diagnostic Ultrasound & Echocardiography Sir Run Run Shaw Hospital Zhejiang University College of Medicine Hangzhou China
12 shared publicationsBei Wang
Department of Diagnostic Ultrasound and Echocardiography Sir Run Run Shaw Hospital, Zhejiang University College of Medicine Hangzhou China
11 shared publicationsMei Pan
Department of Diagnostic Ultrasound & Echocardiography Sir Run Run Shaw Hospital Zhejiang University College of Medicine Hangzhou China
11 shared publicationsXiaohui Peng
Department of Diagnostic Ultrasound and Echocardiography, Sir Run Run Shaw Hospital Zhejiang University Medical College, Technical Guidance Center for Fetal Echocardiography of Zhejiang Province & Sir Run Run Shaw Institute of Clinical Medicine of Zhejiang University Hangzhou China
6 shared publicationsMingming Ma
Department of Diagnostic Ultrasound & Echocardiography, Sir Run Run Shaw Hospital, Zhejiang University College of Medicine, Technical Guidance Center for Fetal Echocardiography of Zhejiang Province & Sir Run Run Shaw Institute of Clinical Medicine of Zhejiang University, Hangzhou 310016, China
4 shared publicationsYankai Mao
Department of Diagnostic Ultrasound and Echocardiography, Zhejiang University School of Medicine Sir Run Run Shaw Hospital
4 shared publications
Latest Publications
- 13 May 2026
- Published by Wiley in Echocardiography
- Vol. 43 (5) , e70499
How Does Right Atrial Function Differ? A Speckle‐Tracking Echocardiographic Comparison of Fetuses With Left Ventricular Outflow Tract Obstruction Versus Those With Significant Tricuspid Regurgitation
Purpose: To evaluate the feasibility of two‐dimensional speckle tracking echocardiography (2D‐STE) for quantitatively assessing right atrial global longitudinal strain (RAGLS) in normal fetuses, and to compare RAGLS among normal fetuses, fetuses with left ventricular outflow tract obstruction (LVOTO), and those with moderate‐to‐severe tricuspid regurgitation (TR). Methods: A total of 32 fetuses with LVOTO, 25 with moderate‐to‐severe TR, and 100 normal fetuses were enrolled. RAGLS was compared among the three groups, and its correlations with gestational age (GA) and other echocardiographic parameters were analyzed. Inter‐ and intra‐observer repeatability was assessed using intraclass correlation coefficients (ICC) and Bland‐Altman analysis. Results: RAGLS differed significantly among the three groups ( p < 0.01). The RAGLS values in both the TR and LVOTO groups were significantly lower than those in the control group (both p < 0.01), whereas the LVOTO group exhibited significantly higher RAGLS compared to the TR group ( p < 0.05). In the control group, RAGLS was negatively correlated with GA ( r = −0.47, p < 0.01). However, in the TR or LVOTO groups, RAGLS showed no significant correlation with GA or other measured parameters (all p > 0.05). The inter‐ and intra‐observer repeatability of RAGLS measurements was good (ICC > 0.75). Conclusion: The right atrial reservoir function is impaired in fetuses with TR and those with LVOTO. RAGLS may serve as a sensitive indicator for quantitatively evaluating RA dysfunction in fetal cardiac anomalies.
- 13 May 2026
- Published by Wiley in Echocardiography
- Vol. 43 (5) , e70499
How Does Right Atrial Function Differ? A Speckle‐Tracking Echocardiographic Comparison of Fetuses With Left Ventricular Outflow Tract Obstruction Versus Those With Significant Tricuspid Regurgitation
Purpose: To evaluate the feasibility of two‐dimensional speckle tracking echocardiography (2D‐STE) for quantitatively assessing right atrial global longitudinal strain (RAGLS) in normal fetuses, and to compare RAGLS among normal fetuses, fetuses with left ventricular outflow tract obstruction (LVOTO), and those with moderate‐to‐severe tricuspid regurgitation (TR). Methods: A total of 32 fetuses with LVOTO, 25 with moderate‐to‐severe TR, and 100 normal fetuses were enrolled. RAGLS was compared among the three groups, and its correlations with gestational age (GA) and other echocardiographic parameters were analyzed. Inter‐ and intra‐observer repeatability was assessed using intraclass correlation coefficients (ICC) and Bland‐Altman analysis. Results: RAGLS differed significantly among the three groups ( p < 0.01). The RAGLS values in both the TR and LVOTO groups were significantly lower than those in the control group (both p < 0.01), whereas the LVOTO group exhibited significantly higher RAGLS compared to the TR group ( p < 0.05). In the control group, RAGLS was negatively correlated with GA ( r = −0.47, p < 0.01). However, in the TR or LVOTO groups, RAGLS showed no significant correlation with GA or other measured parameters (all p > 0.05). The inter‐ and intra‐observer repeatability of RAGLS measurements was good (ICC > 0.75). Conclusion: The right atrial reservoir function is impaired in fetuses with TR and those with LVOTO. RAGLS may serve as a sensitive indicator for quantitatively evaluating RA dysfunction in fetal cardiac anomalies.
- Open Access
- 28 November 2025
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 20 (1) , 443
Congenital descending aorta to pulmonary vein fistula: an unusual cause of left ventricular dilation in a 21-year-old female
Congenital descending aorta to pulmonary vein fistula (cDAPVF) is a rare congenital vascular malformation diagnosed in infancy and childhood. Adult cDAPVF
- 28 November 2025
- Published by Springer Nature in Journal of Cardiothoracic Surgery
- Vol. 20 (1) , 443
Open AccessCongenital descending aorta to pulmonary vein fistula: an unusual cause of left ventricular dilation in a 21-year-old female
Congenital descending aorta to pulmonary vein fistula (cDAPVF) is a rare congenital vascular malformation diagnosed in infancy and childhood. Adult cDAPVF
- 12 April 2025
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 44 (8) , 1391-1404
Assessing Fetal Heart Morphology and Function in Fetuses With Right Ventricular Outflow Obstruction by Fetal Heart Quantitative Technique
Objectives: To investigate the clinical utility of the fetal heart quantification (Fetal HQ) technique in the assessment of morphological and functional changes in fetuses with right ventricular outflow obstruction (RVOTO).Methods: This study included 53 fetuses with RVOTO and 30 age‐matched normal controls. The RVOTO fetuses were divided into 2 groups based on the occurrence of other cardiovascular malformations: the simple pulmonary stenosis (PS group) and the conotruncal defects (CTD group). Size, shape, and contractility parameters of the fetal heart in 4‐chamber view (4CV), left ventricle, and right ventricle (LV and RV) detected by fetal HQ.Results: Fetuses with RVOTO exhibited an increased 4CV‐width, with normal 4CV‐Length. The end‐diastolic diameter (ED) of the LV segments 1–22 was significantly greater in RVOTO fetuses. The sphericity index (SI) of the LV 24‐segment was significantly smaller in the CTD and PS groups. Global longitudinal strain (GLS) and fractional area change (FAC) of the LV and RV were reduced in RVOTO fetuses.Conclusion: Our results suggested that the characteristic changes in the morphology and function of the RVOTO fetal heart could be detected early by the HQ technique, which has clinical utility in analyzing the morphology of the RVOTO fetal heart in a quantitative manner.
- 12 April 2025
- Published by Wiley in Journal of Ultrasound in Medicine
- Vol. 44 (8) , 1391-1404
Assessing Fetal Heart Morphology and Function in Fetuses With Right Ventricular Outflow Obstruction by Fetal Heart Quantitative Technique
Objectives: To investigate the clinical utility of the fetal heart quantification (Fetal HQ) technique in the assessment of morphological and functional changes in fetuses with right ventricular outflow obstruction (RVOTO).Methods: This study included 53 fetuses with RVOTO and 30 age‐matched normal controls. The RVOTO fetuses were divided into 2 groups based on the occurrence of other cardiovascular malformations: the simple pulmonary stenosis (PS group) and the conotruncal defects (CTD group). Size, shape, and contractility parameters of the fetal heart in 4‐chamber view (4CV), left ventricle, and right ventricle (LV and RV) detected by fetal HQ.Results: Fetuses with RVOTO exhibited an increased 4CV‐width, with normal 4CV‐Length. The end‐diastolic diameter (ED) of the LV segments 1–22 was significantly greater in RVOTO fetuses. The sphericity index (SI) of the LV 24‐segment was significantly smaller in the CTD and PS groups. Global longitudinal strain (GLS) and fractional area change (FAC) of the LV and RV were reduced in RVOTO fetuses.Conclusion: Our results suggested that the characteristic changes in the morphology and function of the RVOTO fetal heart could be detected early by the HQ technique, which has clinical utility in analyzing the morphology of the RVOTO fetal heart in a quantitative manner.
- 3 December 2024
- Published by Wiley in British Journal of Haematology
- Vol. 206 (1) , 345-348
Warning from heart: An unusual case report of isolated Rosai‐Dorfman disease in an Asian
- 3 December 2024
- Published by Wiley in British Journal of Haematology
- Vol. 206 (1) , 345-348
Warning from heart: An unusual case report of isolated Rosai‐Dorfman disease in an Asian
- Open Access
- 16 October 2024
- Published by Walter de Gruyter GmbH in Journal of Perinatal Medicine
- Vol. 53 (1) , 80-87
Evaluating fetal pulmonary vascular development in congenital heart disease: a comparative study using the McGoon index and multiple parameters of fetal echocardiography
Objectives: The purpose of this study was to evaluate the value of MGI and multi-parameter in the assessment of different pulmonary circulation blood volumes in congenital heart disease. Methods: This study included 350 fetuses categorized into two groups: Normal group consisted of 258 fetuses with no discernible abnormalities through echocardiography as control Group A; abnormal group with abnormal echocardiogram, including Group B of 71 fetuses with decreased pulmonary blood flow or pulmonary atresia and Group C of 21 fetuses with reduced or detached aortic blood flow. Results: The MGI and Z-scores were measured and compared among these groups. Significant variations were noted in the aortic outflow Z-scores (AO-Zs) (p<0.01), pulmonary artery (PA) (p<0.01), PA Z-scores (PA-Zs) (p<0.01), PA/AO (p<0.01), right PA (p<0.01), and MGI (p<0.01) among the three groups (all p<0.05). Among fetuses with decreased pulmonary blood flow or pulmonary atresia, PA, PA-Zs, and MGI in fetuses with reverse DA flow perfusion were lower than those in the DA forward perfusion group. Conclusions: Fetal echocardiography, incorporating the MGI and multi-parameter, not only allows for the evaluation of pulmonary blood flow and pulmonary vascular development of the fetus but also enables the observation of changes in pulmonary blood flow and MGI development across different gestational weeks.
- 16 October 2024
- Published by Walter de Gruyter GmbH in Journal of Perinatal Medicine
- Vol. 53 (1) , 80-87
Open AccessEvaluating fetal pulmonary vascular development in congenital heart disease: a comparative study using the McGoon index and multiple parameters of fetal echocardiography
Objectives: The purpose of this study was to evaluate the value of MGI and multi-parameter in the assessment of different pulmonary circulation blood volumes in congenital heart disease. Methods: This study included 350 fetuses categorized into two groups: Normal group consisted of 258 fetuses with no discernible abnormalities through echocardiography as control Group A; abnormal group with abnormal echocardiogram, including Group B of 71 fetuses with decreased pulmonary blood flow or pulmonary atresia and Group C of 21 fetuses with reduced or detached aortic blood flow. Results: The MGI and Z-scores were measured and compared among these groups. Significant variations were noted in the aortic outflow Z-scores (AO-Zs) (p<0.01), pulmonary artery (PA) (p<0.01), PA Z-scores (PA-Zs) (p<0.01), PA/AO (p<0.01), right PA (p<0.01), and MGI (p<0.01) among the three groups (all p<0.05). Among fetuses with decreased pulmonary blood flow or pulmonary atresia, PA, PA-Zs, and MGI in fetuses with reverse DA flow perfusion were lower than those in the DA forward perfusion group. Conclusions: Fetal echocardiography, incorporating the MGI and multi-parameter, not only allows for the evaluation of pulmonary blood flow and pulmonary vascular development of the fetus but also enables the observation of changes in pulmonary blood flow and MGI development across different gestational weeks.
- Open Access
- 9 October 2024
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 11, 1466016
Case Report: Multimodality imaging of a bronchogenic cyst in the interatrial septum
Intracardiac bronchogenic cysts (IBCs) are very rare. To date, only a few cases of IBC have been reported in the literature. We report a case of a bronchogenic cyst that arose from the interatrial septum in a 42-year-old man who presented with symptoms of palpitation. A unilocular cystic lesion of the heart was found initially on echocardiography and subsequently on computed tomography and magnetic resonance imaging. The diagnosis was further confirmed by histopathology after surgical resection. Multimodality imaging played a crucial role in the diagnosis and treatment of such rare lesions.
- 9 October 2024
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 11, 1466016
Open AccessCase Report: Multimodality imaging of a bronchogenic cyst in the interatrial septum
Intracardiac bronchogenic cysts (IBCs) are very rare. To date, only a few cases of IBC have been reported in the literature. We report a case of a bronchogenic cyst that arose from the interatrial septum in a 42-year-old man who presented with symptoms of palpitation. A unilocular cystic lesion of the heart was found initially on echocardiography and subsequently on computed tomography and magnetic resonance imaging. The diagnosis was further confirmed by histopathology after surgical resection. Multimodality imaging played a crucial role in the diagnosis and treatment of such rare lesions.
- Open Access
- 18 August 2024
- Published by Association of Basic Medical Sciences of FBIH in Biomolecules and Biomedicine
- Vol. 25 (2) , 482-492
Fetal heart quantification technique improves the prenatal prediction of coarctation of the aorta: A retrospective analysis
Coarctation of the aorta (CoA) ranks among the most prevalent congenital heart defects and poses a life-threatening risk if left undiagnosed. Herein, we utilized fetal heart quantification (HQ) technology to improve the prenatal prediction of CoA. A retrospective analysis was conducted on 64 fetal cases with suspected aortic arch constriction, identified through prenatal ultrasound findings between November 2020 and March 2022 at the Department of Ultrasound, Sir Run Run Shaw Hospital, Zhejiang University. According to the follow-up results, these cases were divided into two groups: 35 cases confirmed as CoA by postpartum surgery or induction, and 29 cases initially suspected of CoA prenatally but subsequently ruled out postnatally. Additionally, 88 cases of normal fetuses were randomly selected as the control group. Both conventional M-mode ultrasound techniques and Fetal HQ software were utilized for fetal analysis across all groups. Parameters related to the heart were measured, including fetal 4-CV length, width, Global Spherical Index (GSI), Mitral Annular Plane Systolic Excursion (MAPSE), areas and ratios of the left and right ventricles, as well as lengths and ratios of the left and right ventricles. Functional measurements of the left and right ventricles included ejection fraction (EF), fractional area change (FAC), global longitudinal strain (GLS), fractional shortening (FS), end-diastolic diameter (ED), and sphericity index (SI). Left ventricular (LV)-GLS, LV-FAC, LV-EF, and LV-EF Z-score could potentially differentiate between true CoA and false CoA or normal groups and serve as potential indicators for the clinical diagnosis of CoA. The receiver operating characteristic (ROC) curves indicated that LV-GLS and LV-EF Z-score have the greatest predictive power for CoA diagnosis. The segments 6-12 of FS in the confirmed CoA group were significantly lower than those in the false CoA and normal groups. Fetal HQ technology, by assessing changes in the size and shape of the heart, can provide relatively reliable parameter support for the prenatal diagnosis of fetal aortic coarctation.
- 18 August 2024
- Published by Association of Basic Medical Sciences of FBIH in Biomolecules and Biomedicine
- Vol. 25 (2) , 482-492
Open AccessFetal heart quantification technique improves the prenatal prediction of coarctation of the aorta: A retrospective analysis
Coarctation of the aorta (CoA) ranks among the most prevalent congenital heart defects and poses a life-threatening risk if left undiagnosed. Herein, we utilized fetal heart quantification (HQ) technology to improve the prenatal prediction of CoA. A retrospective analysis was conducted on 64 fetal cases with suspected aortic arch constriction, identified through prenatal ultrasound findings between November 2020 and March 2022 at the Department of Ultrasound, Sir Run Run Shaw Hospital, Zhejiang University. According to the follow-up results, these cases were divided into two groups: 35 cases confirmed as CoA by postpartum surgery or induction, and 29 cases initially suspected of CoA prenatally but subsequently ruled out postnatally. Additionally, 88 cases of normal fetuses were randomly selected as the control group. Both conventional M-mode ultrasound techniques and Fetal HQ software were utilized for fetal analysis across all groups. Parameters related to the heart were measured, including fetal 4-CV length, width, Global Spherical Index (GSI), Mitral Annular Plane Systolic Excursion (MAPSE), areas and ratios of the left and right ventricles, as well as lengths and ratios of the left and right ventricles. Functional measurements of the left and right ventricles included ejection fraction (EF), fractional area change (FAC), global longitudinal strain (GLS), fractional shortening (FS), end-diastolic diameter (ED), and sphericity index (SI). Left ventricular (LV)-GLS, LV-FAC, LV-EF, and LV-EF Z-score could potentially differentiate between true CoA and false CoA or normal groups and serve as potential indicators for the clinical diagnosis of CoA. The receiver operating characteristic (ROC) curves indicated that LV-GLS and LV-EF Z-score have the greatest predictive power for CoA diagnosis. The segments 6-12 of FS in the confirmed CoA group were significantly lower than those in the false CoA and normal groups. Fetal HQ technology, by assessing changes in the size and shape of the heart, can provide relatively reliable parameter support for the prenatal diagnosis of fetal aortic coarctation.
- Open Access
- 27 July 2024
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 53, 101380
Artificial intelligence in fetal echocardiography: Recent advances and future prospects
- 27 July 2024
- Published by Elsevier in IJC Heart & Vasculature
- Vol. 53, 101380
Open AccessArtificial intelligence in fetal echocardiography: Recent advances and future prospects
- 14 March 2024
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 52 (5) , 535-541
Echocardiographic features and outcomes of fetuses with isolated restrictive foramen ovale or redundant foramen ovale flap using atrial septum excursion index
Purpose: This study was designed to investigate the application value of the atrial septum excursion index (ASEI) in fetuses with isolated restrictive foramen ovale (RFO) or redundant foramen ovale flap (RFOF) and the outcomes of these fetuses.Methods: This was a retrospective study. Healthy pregnant women who were examined by antenatal fetal echocardiography from January 1, 2019 to December 31, 2021, at Sir Run Run Shaw Hospital were enrolled. One hundred seventy‐seven (177) fetuses were categorized into three groups by diagnosis: (1) RFOF (n = 33), (2) RFO (n = 21), and (3) normal (n = 123). Fetal echocardiographic features and postnatal outcomes were collected.Results: The median ASEIs were 0.50 (range, 0.41–0.65) in the control group, 0.76 (range, 0.67–0.88) in the RFOF group and 0.31 (range, 0.14–0.35) in the RFO group, and the differences were significant (p < 0.001). The ratios of right atrium/left atrium, right ventricle/left ventricle, and pulmonary artery diameter to aorta diameter (PA/AO) and the pulmonary annulus Z‐scores were greater in fetuses with RFOF and RFO than in the controls (p < 0.05). Twenty‐seven of 33 fetuses (87.9%) with RFOF and 19 of 21 fetuses (90.5%) with RFO had good outcomes after birth.Conclusion: The ASEI may be a new tool for quantitatively assessing the mobility of foramen ovale flaps in fetuses with isolated RFOF or RFO.
- 14 March 2024
- Published by Wiley in Journal of Clinical Ultrasound
- Vol. 52 (5) , 535-541
Echocardiographic features and outcomes of fetuses with isolated restrictive foramen ovale or redundant foramen ovale flap using atrial septum excursion index
Purpose: This study was designed to investigate the application value of the atrial septum excursion index (ASEI) in fetuses with isolated restrictive foramen ovale (RFO) or redundant foramen ovale flap (RFOF) and the outcomes of these fetuses.Methods: This was a retrospective study. Healthy pregnant women who were examined by antenatal fetal echocardiography from January 1, 2019 to December 31, 2021, at Sir Run Run Shaw Hospital were enrolled. One hundred seventy‐seven (177) fetuses were categorized into three groups by diagnosis: (1) RFOF (n = 33), (2) RFO (n = 21), and (3) normal (n = 123). Fetal echocardiographic features and postnatal outcomes were collected.Results: The median ASEIs were 0.50 (range, 0.41–0.65) in the control group, 0.76 (range, 0.67–0.88) in the RFOF group and 0.31 (range, 0.14–0.35) in the RFO group, and the differences were significant (p < 0.001). The ratios of right atrium/left atrium, right ventricle/left ventricle, and pulmonary artery diameter to aorta diameter (PA/AO) and the pulmonary annulus Z‐scores were greater in fetuses with RFOF and RFO than in the controls (p < 0.05). Twenty‐seven of 33 fetuses (87.9%) with RFOF and 19 of 21 fetuses (90.5%) with RFO had good outcomes after birth.Conclusion: The ASEI may be a new tool for quantitatively assessing the mobility of foramen ovale flaps in fetuses with isolated RFOF or RFO.
- 6 February 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (17) , 1575
Multimodality imaging of acute intramyocardial dissecting haematoma and its dynamic progression
A 65-year-old man was hospitalized 9 h later after a transient syncope. Electrocardiogram displayed abnormal Q-waves in the inferior wall, accompanied by modest elevation of the ST-segment. Coronary angiography showed an occlusive stenosis in the first obtuse marginal artery. Transthoracic echocardiography (TTE) revealed reduced left ventricular (LV) ejection fraction (49%) and an intramyocardial dissecting haematoma (IDH) in the lateral wall of the LV. The IDH communicated with LV through a ruptured endocardium (Panels A–C; Supplementary data online, Videos S1 and S2). Cardiovascular magnetic resonance imaging detected a heterogenous hypointense mass separated by the LV cavity with a thin line of late gadolinium enhancement (Panels D and E; Supplementary data online, Videos S3 and S4). Considering the high risk for operation during acute myocardial infarction (AMI), the patient was only treated with medications. Transthoracic echocardiography recorded the dynamic progress of the IDH in 24 days (Panel F; Supplementary data online, Figure S1). The subsequent operation detected a breakage in the endocardium (see Supplementary data online, Figure S2) and a grey myocardial infarction (Panel G). The patient has recovered during the 6-month follow-up.
- 6 February 2024
- Published by Oxford University Press (OUP) in European Heart Journal
- Vol. 45 (17) , 1575
Multimodality imaging of acute intramyocardial dissecting haematoma and its dynamic progression
A 65-year-old man was hospitalized 9 h later after a transient syncope. Electrocardiogram displayed abnormal Q-waves in the inferior wall, accompanied by modest elevation of the ST-segment. Coronary angiography showed an occlusive stenosis in the first obtuse marginal artery. Transthoracic echocardiography (TTE) revealed reduced left ventricular (LV) ejection fraction (49%) and an intramyocardial dissecting haematoma (IDH) in the lateral wall of the LV. The IDH communicated with LV through a ruptured endocardium (Panels A–C; Supplementary data online, Videos S1 and S2). Cardiovascular magnetic resonance imaging detected a heterogenous hypointense mass separated by the LV cavity with a thin line of late gadolinium enhancement (Panels D and E; Supplementary data online, Videos S3 and S4). Considering the high risk for operation during acute myocardial infarction (AMI), the patient was only treated with medications. Transthoracic echocardiography recorded the dynamic progress of the IDH in 24 days (Panel F; Supplementary data online, Figure S1). The subsequent operation detected a breakage in the endocardium (see Supplementary data online, Figure S2) and a grey myocardial infarction (Panel G). The patient has recovered during the 6-month follow-up.