Aleksandr A. Chekushin
Research Subjects
Aleksandr A. Chekushin has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- Andrey Vladimirovich Fedoseev
Ryazan State Medical University
4 shared publications - Alexey Viktorovich Alpatov
Ryazan State Medical University
2 shared publications - Anna V. Kulakova
Ryazan State Medical University
2 shared publications - Maria Sergeevna Ashapkina
I.M. Sechenov First Moscow State Medical University (Sechenovskiy University)
2 shared publications - Polina A. Kiseleva
Ryazan State Medical University
2 shared publications - Vadim N. Budarev
Ryazan State Medical University
2 shared publications
Latest Publications
- Open Access
- 30 June 2026
- Published by ECO-Vector LLC (Publications) in I.P. Pavlov Russian Medical Biological Herald
- Vol. 34 (2) , 299-309
Comparison of digital gait study methods (non-systematic review)
BACKGROUND: Human gait is of scientific and practical interest in medical knowledge system, since standardized gait parameters can help assess the results of conservative or surgical treatment in various categories of patients. Digital study methods allow for an objective assessment of the lower limb functions in locomotion. AIM: To conduct a comparative analysis of digital gait assessment methods in terms of their advantages, limitations and scope of application. This article systematizes the main digital methods for studying gait, provides their original classification, examples of ready-made solutions available on the market, and identifies key trends in gait study. It demonstrates that the 'gold standard' for studying gait is the use of optical systems. The method gaining popularity among researchers, is the use of inertial sensors based on microelectromechanical systems, but it often requires validation. Pedobarography is a valuable tool for identifying key step events and load distribution during walking. Electromyography, electrogoniometry, and electroencephalography are auxiliary methods. A relevant area of research is machine learning technologies facilitating work with large amounts of data obtained in research. CONCLUSION: Digital gait analysis methods are a diverse group comprising various technologies, the leading ones being optical systems and inertial sensors based on microelectromechanical systems. Promising direction of research are methods of gadget minimization and machine learning.
- 30 June 2026
- Published by ECO-Vector LLC (Publications) in I.P. Pavlov Russian Medical Biological Herald
- Vol. 34 (2) , 299-309
Open AccessComparison of digital gait study methods (non-systematic review)
BACKGROUND: Human gait is of scientific and practical interest in medical knowledge system, since standardized gait parameters can help assess the results of conservative or surgical treatment in various categories of patients. Digital study methods allow for an objective assessment of the lower limb functions in locomotion. AIM: To conduct a comparative analysis of digital gait assessment methods in terms of their advantages, limitations and scope of application. This article systematizes the main digital methods for studying gait, provides their original classification, examples of ready-made solutions available on the market, and identifies key trends in gait study. It demonstrates that the 'gold standard' for studying gait is the use of optical systems. The method gaining popularity among researchers, is the use of inertial sensors based on microelectromechanical systems, but it often requires validation. Pedobarography is a valuable tool for identifying key step events and load distribution during walking. Electromyography, electrogoniometry, and electroencephalography are auxiliary methods. A relevant area of research is machine learning technologies facilitating work with large amounts of data obtained in research. CONCLUSION: Digital gait analysis methods are a diverse group comprising various technologies, the leading ones being optical systems and inertial sensors based on microelectromechanical systems. Promising direction of research are methods of gadget minimization and machine learning.
- 31 March 2026
- Published by Ryazan State Medical University in Nauka Molodykh (Eruditio Juvenium)
- Vol. 14 (1)
Application of Video-Analysis Program Based on MediaPipe Pose for Diagnosis of Gait Disorders in Outpatient Setting: Two Clinical Cases
BACKGROUND: In recent years, alternative methods based on video recording and machine learning (ML) have been actively developed. These methods allow for objective assessment of movement parameters using a single device, significantly reducing time and cost. However, for the differential diagnosis of normal and pathological conditions, clinical validation of such approaches is required. AIM: To demonstrate the potentials of the developed gait video analysis program based on the MediaPipe Pose platform for quantitative assessment and comparison of spatiotemporal gait parameters in a healthy volunteer and a female patient with osteoarthritis (OA) of the knee joints. METHODS: The study was conducted on a stand (a treadmill, a GoPro 4K/60fps camera). The program based on MediaPipe Pose identified 33 key body points with calculation of knee joint angles, step timing characteristics, symmetry coefficients, and variability. Two clinical cases are presented. CONCLUSION: A video analysis program based on MediaPipe Pose allows for quantitative differentiation between pathological and normal walking pattern. Changes identified in a patient with gonarthrosis are consistent with the clinical picture and can serve as objective markers of disorders. The method holds promise for clinical application as an accessible screening tool. Further work to improve the program will focus on studying flexion angles in the lower extremity joints relative to gait events, examining their interrelationships to obtain more accurate results.
- 31 March 2026
- Published by Ryazan State Medical University in Nauka Molodykh (Eruditio Juvenium)
- Vol. 14 (1)
Application of Video-Analysis Program Based on MediaPipe Pose for Diagnosis of Gait Disorders in Outpatient Setting: Two Clinical Cases
BACKGROUND: In recent years, alternative methods based on video recording and machine learning (ML) have been actively developed. These methods allow for objective assessment of movement parameters using a single device, significantly reducing time and cost. However, for the differential diagnosis of normal and pathological conditions, clinical validation of such approaches is required. AIM: To demonstrate the potentials of the developed gait video analysis program based on the MediaPipe Pose platform for quantitative assessment and comparison of spatiotemporal gait parameters in a healthy volunteer and a female patient with osteoarthritis (OA) of the knee joints. METHODS: The study was conducted on a stand (a treadmill, a GoPro 4K/60fps camera). The program based on MediaPipe Pose identified 33 key body points with calculation of knee joint angles, step timing characteristics, symmetry coefficients, and variability. Two clinical cases are presented. CONCLUSION: A video analysis program based on MediaPipe Pose allows for quantitative differentiation between pathological and normal walking pattern. Changes identified in a patient with gonarthrosis are consistent with the clinical picture and can serve as objective markers of disorders. The method holds promise for clinical application as an accessible screening tool. Further work to improve the program will focus on studying flexion angles in the lower extremity joints relative to gait events, examining their interrelationships to obtain more accurate results.
- 16 July 2023
- Published by ECO-Vector LLC in I.P. Pavlov Russian Medical Biological Herald
- Vol. 31 (2) , 317-328
Complex Approach in Examination of Function of the Knee Joint in Patients with Osteoarthritis
INTRODUCTION: Osteoarthritis (OA) of the knee joint (KJ) is a common problem. The basic factors impairing the function of the KJ are pain and restriction of movement. Evaluation of function of the KJ in OA is an indispensable part of the diagnostic and treatment process. There exists a problem of a quantitative evaluation of pain and restriction of movement of the KJ in OA, associated with the absence of a single standard for evaluation of the KJ function. In the article, the data are given on the modern possibilities for evaluation of the KJ function in OA. The KJ function is evaluated in clinical examination, functional tests, numerous functional questionnaires, as well as with the use of devices for record of movements. Clinical picture of OA of the KJ is evaluated in the clinical examination which includes diagnostic tests, evaluation of the volume of movement, force of muscles, with conclusions about the phenotype of the disease. Functional tests recommended by OARSI (Osteoarthritis Research Society International) are preferable for express-testing, but not all of them have reference values. Functional questionnaires for evaluation of the KJ function exist in many variants, which impedes their choice and interaction between specialists, and they are characterized by different labor intensity in use. There exists a diversity of devices for evaluation of function of the KJ, some of which are expensive, require special rooms, training of the specialist, and take considerable time. Others are simpler in use and inexpensive, but give less reliable results. CONCLUSION: The authors showed the possibilities of a comprehensive evaluation, described the problem of the lack of a single standard for investigation of the KJ function. A conclusion is made about the necessity to develop a software-hardware complex that maximally satisfies the criteria of objectivity, accessibility and quickness of use for evaluation of function of the KJ in OA.
- 16 July 2023
- Published by ECO-Vector LLC in I.P. Pavlov Russian Medical Biological Herald
- Vol. 31 (2) , 317-328
Complex Approach in Examination of Function of the Knee Joint in Patients with Osteoarthritis
INTRODUCTION: Osteoarthritis (OA) of the knee joint (KJ) is a common problem. The basic factors impairing the function of the KJ are pain and restriction of movement. Evaluation of function of the KJ in OA is an indispensable part of the diagnostic and treatment process. There exists a problem of a quantitative evaluation of pain and restriction of movement of the KJ in OA, associated with the absence of a single standard for evaluation of the KJ function. In the article, the data are given on the modern possibilities for evaluation of the KJ function in OA. The KJ function is evaluated in clinical examination, functional tests, numerous functional questionnaires, as well as with the use of devices for record of movements. Clinical picture of OA of the KJ is evaluated in the clinical examination which includes diagnostic tests, evaluation of the volume of movement, force of muscles, with conclusions about the phenotype of the disease. Functional tests recommended by OARSI (Osteoarthritis Research Society International) are preferable for express-testing, but not all of them have reference values. Functional questionnaires for evaluation of the KJ function exist in many variants, which impedes their choice and interaction between specialists, and they are characterized by different labor intensity in use. There exists a diversity of devices for evaluation of function of the KJ, some of which are expensive, require special rooms, training of the specialist, and take considerable time. Others are simpler in use and inexpensive, but give less reliable results. CONCLUSION: The authors showed the possibilities of a comprehensive evaluation, described the problem of the lack of a single standard for investigation of the KJ function. A conclusion is made about the necessity to develop a software-hardware complex that maximally satisfies the criteria of objectivity, accessibility and quickness of use for evaluation of function of the KJ in OA.
- Open Access
- 18 January 2023
- Published by LLC Global Media Technology in Experimental and Clinical Gastroenterology
- No. 10,p. 58-62
Method for increasing scientific value of portal hypertension modeling experiment
Aim: development and testing of a technically simple method for the formation of portal hypertension in the body of a domestic pig, which makes it possible to obtain a model that is close in key parameters to humans. Materials and methods. The material of the study was the results of an experiment conducted in the vivarium of the Ryazan State Medical University on 12 domestic pigs. Results. A method for modeling portal hypertension in the body of a domestic pig by dosed compression of the hepatoduodenal ligament with a plastic clamp was developed and tested. Conclusions. A model of portal hypertension was obtained, which makes it possible to obtain scientific data easily extended to humans, due to the similarity of the anatomy, physiology, and size of the used laboratory animal with those of humans.
- 18 January 2023
- Published by LLC Global Media Technology in Experimental and Clinical Gastroenterology
- No. 10,p. 58-62
Open AccessMethod for increasing scientific value of portal hypertension modeling experiment
Aim: development and testing of a technically simple method for the formation of portal hypertension in the body of a domestic pig, which makes it possible to obtain a model that is close in key parameters to humans. Materials and methods. The material of the study was the results of an experiment conducted in the vivarium of the Ryazan State Medical University on 12 domestic pigs. Results. A method for modeling portal hypertension in the body of a domestic pig by dosed compression of the hepatoduodenal ligament with a plastic clamp was developed and tested. Conclusions. A model of portal hypertension was obtained, which makes it possible to obtain scientific data easily extended to humans, due to the similarity of the anatomy, physiology, and size of the used laboratory animal with those of humans.
- Open Access
- 15 July 2022
- Published by ECO-Vector LLC in Perm Medical Journal
- Vol. 39 (3) , 137-142
Modeling of bleeding from varicose vein of esophagus in a laboratory animal
Objective. To develop an accessible, easily reproducible, functional method for modeling bleeding from varicose veins of the esophagus based on the body of a laboratory animal. Materials and methods. The work is based on an experiment carried out in the operating room of the vivarium of Ryazan State Medical University using laboratory animals 12 domestic pigs of the Large White breed. Results. In 10 cases out of 12, it was possible to successfully form changes in the animal's body, allowing to provoke bleeding from the dilated veins of the esophagus, damaging them with biopsy forceps during fibroesophagoscopy. Conclusions. Creation of an experimental model of bleeding from varicose veins of the esophagus in the body of a domestic pig by dosed clamping of the hepato-duodenal ligament with a plastic clamp, which was followed by subsequent damage of the esophageal veins with biopsy forceps during fibroesophagoscopy, is technically feasible, reliable, and the model itself is quite functional.
- 15 July 2022
- Published by ECO-Vector LLC in Perm Medical Journal
- Vol. 39 (3) , 137-142
Open AccessModeling of bleeding from varicose vein of esophagus in a laboratory animal
Objective. To develop an accessible, easily reproducible, functional method for modeling bleeding from varicose veins of the esophagus based on the body of a laboratory animal. Materials and methods. The work is based on an experiment carried out in the operating room of the vivarium of Ryazan State Medical University using laboratory animals 12 domestic pigs of the Large White breed. Results. In 10 cases out of 12, it was possible to successfully form changes in the animal's body, allowing to provoke bleeding from the dilated veins of the esophagus, damaging them with biopsy forceps during fibroesophagoscopy. Conclusions. Creation of an experimental model of bleeding from varicose veins of the esophagus in the body of a domestic pig by dosed clamping of the hepato-duodenal ligament with a plastic clamp, which was followed by subsequent damage of the esophageal veins with biopsy forceps during fibroesophagoscopy, is technically feasible, reliable, and the model itself is quite functional.
- Open Access
- 15 March 2015
- Published by ECO-Vector LLC in I.P. Pavlov Russian Medical Biological Herald
- Vol. 23 (1) , 168-174
The problems of cement fixation of hip prosthesis components in patients with hip fracture (review)
Hip joint arthroplasty one of wasps mainly treatment of degenerative diseases and injuries of the hip joint. There are two methods of fixing components of hip prosthesis - cement and cementless. The authors present data on the problems of cement hip joint arthroplasty both during consideration of the properties of bone cement, and clinical stage. Also highlight the prospects development of new types of bone cement.
- 15 March 2015
- Published by ECO-Vector LLC in I.P. Pavlov Russian Medical Biological Herald
- Vol. 23 (1) , 168-174
Open AccessThe problems of cement fixation of hip prosthesis components in patients with hip fracture (review)
Hip joint arthroplasty one of wasps mainly treatment of degenerative diseases and injuries of the hip joint. There are two methods of fixing components of hip prosthesis - cement and cementless. The authors present data on the problems of cement hip joint arthroplasty both during consideration of the properties of bone cement, and clinical stage. Also highlight the prospects development of new types of bone cement.