Amrita Banerjee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Amrita Banerjee has a total of 37 co-authors. Here are the top co-authors by number of shared publications:
- Anna Louise David
University College London
3 shared publications Davor Jurkovic
Elizabeth Garett Anderson Institute for Women's Health, University College London London UK
3 shared publicationsMaria Ivan
Fetal Medicine Unit, Elizabeth Garrett Anderson Wing University College London Hospital London UK
3 shared publicationsRaffaele Napolitano
Fetal Medicine Unit, Elizabeth Garrett Anderson Wing University College London Hospital London UK
3 shared publications- Raffaele Napolitano
Fetal Medicine Unit University College London Hospitals NHS Foundation Trust London UK
3 shared publications A. L. David
Fetal Medicine Unit University College London Hospitals NHS Foundation Trust London UK
2 shared publications
Latest Publications
- Open Access
- 10 April 2026
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 105 (6) , 1140-1150
Prediction of preterm birth using 3D volume cesarean scar morphology in pregnant women with previous advanced labor cesarean delivery
Introduction: This study aimed to develop a multiparameter predictive model for spontaneous preterm birth in pregnant women with a history of advanced labor cesarean delivery, using cesarean scar ultrasound characteristics. Material and Methods: This prospective observational cohort study included pregnant women with a history of advanced labor cesarean delivery (≥8 cm cervical dilatation) at University College London Hospitals (August 2019–August 2023). Participants underwent transvaginal ultrasound using validated protocols for cesarean scar evaluation. Measurements included scar distance to the internal os, niche dimensions (length, depth, and width), residual and adjacent myometrial thickness, and 3D niche and cervical volumes. Predictive models for spontaneous preterm birth and short cervical length ≤25 mm were developed using multivariable logistic regression, adjusting for potential confounders. Results: During the surveillance period, 12.6% (21/166) of women developed a short cervix, and 23.5% (39/166) received preterm birth prophylactic interventions. Spontaneous preterm birth rate was 7.8% (13/166) p = 0.006; aOR 5.00, 95% CI 1.10, 22.78, p = 0.037, respectively). Traditional predictive models based on cervical length and obstetric history demonstrated modest performance. Scar distance to the internal os consistently emerged as the strongest independent predictor of short cervix across all models ( p < 0.001–0.005). Models incorporating 3D ultrasound scar parameters improved predictive accuracy, with the final model achieving AUC 0.91 (95% CI 0.81, 0.98) and 91% (95% CI 0.73, 1.00) sensitivity at FPR of 25% for spontaneous preterm birth. For short cervix prediction, the AUC was 0.89 (95% CI 0.80, 0.96), at 88% (95% CI 0.62, 1.00) sensitivity for the same FPR. Conclusions: 3D transvaginal ultrasound assessment of cesarean scar morphology was associated with improved prediction of spontaneous preterm birth in pregnant women with a history of advanced labor cesarean delivery; however, scar position relative to the internal os remained the strongest individual predictor.
- 10 April 2026
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 105 (6) , 1140-1150
Open AccessPrediction of preterm birth using 3D volume cesarean scar morphology in pregnant women with previous advanced labor cesarean delivery
Introduction: This study aimed to develop a multiparameter predictive model for spontaneous preterm birth in pregnant women with a history of advanced labor cesarean delivery, using cesarean scar ultrasound characteristics. Material and Methods: This prospective observational cohort study included pregnant women with a history of advanced labor cesarean delivery (≥8 cm cervical dilatation) at University College London Hospitals (August 2019–August 2023). Participants underwent transvaginal ultrasound using validated protocols for cesarean scar evaluation. Measurements included scar distance to the internal os, niche dimensions (length, depth, and width), residual and adjacent myometrial thickness, and 3D niche and cervical volumes. Predictive models for spontaneous preterm birth and short cervical length ≤25 mm were developed using multivariable logistic regression, adjusting for potential confounders. Results: During the surveillance period, 12.6% (21/166) of women developed a short cervix, and 23.5% (39/166) received preterm birth prophylactic interventions. Spontaneous preterm birth rate was 7.8% (13/166) p = 0.006; aOR 5.00, 95% CI 1.10, 22.78, p = 0.037, respectively). Traditional predictive models based on cervical length and obstetric history demonstrated modest performance. Scar distance to the internal os consistently emerged as the strongest independent predictor of short cervix across all models ( p < 0.001–0.005). Models incorporating 3D ultrasound scar parameters improved predictive accuracy, with the final model achieving AUC 0.91 (95% CI 0.81, 0.98) and 91% (95% CI 0.73, 1.00) sensitivity at FPR of 25% for spontaneous preterm birth. For short cervix prediction, the AUC was 0.89 (95% CI 0.80, 0.96), at 88% (95% CI 0.62, 1.00) sensitivity for the same FPR. Conclusions: 3D transvaginal ultrasound assessment of cesarean scar morphology was associated with improved prediction of spontaneous preterm birth in pregnant women with a history of advanced labor cesarean delivery; however, scar position relative to the internal os remained the strongest individual predictor.
- Open Access
- 19 January 2026
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 105 (3) , 528-536
Risk of recurrent spontaneous preterm birth following preterm full dilatation cesarean delivery
Introduction: Term full dilatation cesarean delivery (FDCD) is associated with an increased risk of subsequent spontaneous preterm birth (sPTB). The impact of preterm FDCD on recurrent sPTB is unknown. We investigated the relationship between recurrent sPTB and the mode of prior sPTB. Material and Methods: This is a retrospective cohort study of singleton pregnant women attending two high‐risk preterm birth surveillance clinics (University College London Hospital and St Thomas' Hospital London, UK), with one previous sPTB (24–36 + 6 weeks). Women were categorized according to their mode of birth in the index sPTB pregnancy: (1) preterm FDCD, (2) preterm vaginal birth and (3) preterm cesarean delivery at p = 0.454). Recurrent sPTB p = 0.023) and 5.1 (95% CI 1.6–16.5; p = 0.022), respectively. Recurrent sPTB p = 0.016) and 5.7 (95% CI 1.4–23.1; p = 0.022), respectively. CD scar location was assessed in 15 women with preterm FDCD in one centre. Scar visualization was 87%, with 77% (10/13) of scars being located within the cervix or <5 mm above the internal cervical os. Conclusions: Women undergoing FDCD following preterm labor have a significantly higher risk of recurrent sPTB at <37 and <34 weeks of gestation compared to women with previous preterm vaginal birth or CD prior to the second stage of labor. These findings suggest that preterm FDCD may further compromise cervical function. It is important that clinicians are aware of this increased risk of recurrent sPTB to guide patient counseling and management accordingly.
- 19 January 2026
- Published by Wiley in Acta Obstetricia et Gynecologica Scandinavica
- Vol. 105 (3) , 528-536
Open AccessRisk of recurrent spontaneous preterm birth following preterm full dilatation cesarean delivery
Introduction: Term full dilatation cesarean delivery (FDCD) is associated with an increased risk of subsequent spontaneous preterm birth (sPTB). The impact of preterm FDCD on recurrent sPTB is unknown. We investigated the relationship between recurrent sPTB and the mode of prior sPTB. Material and Methods: This is a retrospective cohort study of singleton pregnant women attending two high‐risk preterm birth surveillance clinics (University College London Hospital and St Thomas' Hospital London, UK), with one previous sPTB (24–36 + 6 weeks). Women were categorized according to their mode of birth in the index sPTB pregnancy: (1) preterm FDCD, (2) preterm vaginal birth and (3) preterm cesarean delivery at p = 0.454). Recurrent sPTB p = 0.023) and 5.1 (95% CI 1.6–16.5; p = 0.022), respectively. Recurrent sPTB p = 0.016) and 5.7 (95% CI 1.4–23.1; p = 0.022), respectively. CD scar location was assessed in 15 women with preterm FDCD in one centre. Scar visualization was 87%, with 77% (10/13) of scars being located within the cervix or <5 mm above the internal cervical os. Conclusions: Women undergoing FDCD following preterm labor have a significantly higher risk of recurrent sPTB at <37 and <34 weeks of gestation compared to women with previous preterm vaginal birth or CD prior to the second stage of labor. These findings suggest that preterm FDCD may further compromise cervical function. It is important that clinicians are aware of this increased risk of recurrent sPTB to guide patient counseling and management accordingly.
- Open Access
- 8 November 2025
- Published by Elsevier in American Journal of Obstetrics & Gynecology MFM
- Vol. 8 (1) , 101839
A systematic review of transvaginal ultrasound assessment of cesarean scar characteristics and prediction of adverse obstetric outcomes
- 8 November 2025
- Published by Elsevier in American Journal of Obstetrics & Gynecology MFM
- Vol. 8 (1) , 101839
Open AccessA systematic review of transvaginal ultrasound assessment of cesarean scar characteristics and prediction of adverse obstetric outcomes
- Open Access
- 25 February 2025
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 65 (3) , 344-352
Transvaginal cervical cerclage: double monofilament modified Wurm vs single braided McDonald technique
Objective: To compare pregnancy outcome in women at high risk of preterm birth undergoing the modified Wurm (two monofilament sutures) vs those undergoing the McDonald (single braided suture) transvaginal cervical cerclage technique. Methods: This was a single‐center prospective observational study of all women with a singleton pregnancy attending a prematurity surveillance clinic because of an increased risk of preterm birth, and undergoing history‐ or ultrasound‐indicated transvaginal cervical cerclage. Two cerclage techniques were evaluated and the choice of cerclage was at the physician's discretion. In the modified Wurm technique using monofilament material, two circumferential sutures are placed with two insertions each (four in total). Outcomes were compared vs those of women undergoing the McDonald technique (single braided suture using a diamond‐type insertion method with four insertions in total). Primary outcome was the rate of preterm birth at < 32 weeks' gestation, with planned subanalyses according to cervical cerclage indication (history‐ or ultrasound‐indicated), preterm birth rate at any gestational age (< 37, < 34, < 28 and < 24 weeks), and sonographic cervical length (CL) of ≤ 25 mm and ≤ 15 mm. Secondary outcome measures included maternal and neonatal adverse events and outcomes, including the pre‐ and postsurgical characteristics. In addition, a reproducibility analysis using Bland–Altman plots was performed to evaluate the intra‐ and interobserver reproducibility in assessment of CL on ultrasound examination before and after cerclage. Results: In total, 147 patients were included in the final analysis: 55 (37%) received modified Wurm cerclage and 92 (63%) received McDonald cerclage. Other than race, demographic characteristics were comparable between the two groups. Of these, 22 (40%) women in the modified Wurm group had history‐indicated cerclage, vs 50 (54%) women in the McDonald group; the remaining cerclages were ultrasound‐indicated. In women with a short CL (≤ 25 mm), there was a significantly lower rate of preterm birth at < 32 weeks' gestation after modified Wurm compared with the McDonald technique (3 (9%) vs 14 (29%); adjusted odds ratio (aOR), 0.25 (95% CI, 0.06–0.95); P = 0.042). However, the study was underpowered to provide definitive conclusions. In the overall population, there was no significant difference in preterm birth rate for < 32 weeks' gestation between the two techniques (7 (13%) vs 22 (24%); aOR, 0.51 (95% CI, 0.20–1.33); P = 0.169). There was no difference in overall surgical complications between the two techniques. The pregnancy loss rate and composite neonatal morbidity/mortality rate were comparable between the two groups (2 (4%) vs 7 (8%); odds ratio (OR), 0.47 (95% CI, 0.09–2.33); P = 0.485; and 5 (9%) vs 11 (13%); OR, 0.68; (95% CI, 0.22–2.09); P = 0.593, respectively). Conclusions: In high‐risk women with a sonographic short CL, placement of a modified Wurm cervical cerclage is associated with a lower rate of preterm birth < 32 weeks compared with McDonald cervical cerclage. Further research in larger cohorts is needed to confirm this finding and to determine if this technique reduces the preterm birth rate after elective cervical cerclage without CL shortening. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
- 25 February 2025
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 65 (3) , 344-352
Open AccessTransvaginal cervical cerclage: double monofilament modified Wurm vs single braided McDonald technique
Objective: To compare pregnancy outcome in women at high risk of preterm birth undergoing the modified Wurm (two monofilament sutures) vs those undergoing the McDonald (single braided suture) transvaginal cervical cerclage technique. Methods: This was a single‐center prospective observational study of all women with a singleton pregnancy attending a prematurity surveillance clinic because of an increased risk of preterm birth, and undergoing history‐ or ultrasound‐indicated transvaginal cervical cerclage. Two cerclage techniques were evaluated and the choice of cerclage was at the physician's discretion. In the modified Wurm technique using monofilament material, two circumferential sutures are placed with two insertions each (four in total). Outcomes were compared vs those of women undergoing the McDonald technique (single braided suture using a diamond‐type insertion method with four insertions in total). Primary outcome was the rate of preterm birth at < 32 weeks' gestation, with planned subanalyses according to cervical cerclage indication (history‐ or ultrasound‐indicated), preterm birth rate at any gestational age (< 37, < 34, < 28 and < 24 weeks), and sonographic cervical length (CL) of ≤ 25 mm and ≤ 15 mm. Secondary outcome measures included maternal and neonatal adverse events and outcomes, including the pre‐ and postsurgical characteristics. In addition, a reproducibility analysis using Bland–Altman plots was performed to evaluate the intra‐ and interobserver reproducibility in assessment of CL on ultrasound examination before and after cerclage. Results: In total, 147 patients were included in the final analysis: 55 (37%) received modified Wurm cerclage and 92 (63%) received McDonald cerclage. Other than race, demographic characteristics were comparable between the two groups. Of these, 22 (40%) women in the modified Wurm group had history‐indicated cerclage, vs 50 (54%) women in the McDonald group; the remaining cerclages were ultrasound‐indicated. In women with a short CL (≤ 25 mm), there was a significantly lower rate of preterm birth at < 32 weeks' gestation after modified Wurm compared with the McDonald technique (3 (9%) vs 14 (29%); adjusted odds ratio (aOR), 0.25 (95% CI, 0.06–0.95); P = 0.042). However, the study was underpowered to provide definitive conclusions. In the overall population, there was no significant difference in preterm birth rate for < 32 weeks' gestation between the two techniques (7 (13%) vs 22 (24%); aOR, 0.51 (95% CI, 0.20–1.33); P = 0.169). There was no difference in overall surgical complications between the two techniques. The pregnancy loss rate and composite neonatal morbidity/mortality rate were comparable between the two groups (2 (4%) vs 7 (8%); odds ratio (OR), 0.47 (95% CI, 0.09–2.33); P = 0.485; and 5 (9%) vs 11 (13%); OR, 0.68; (95% CI, 0.22–2.09); P = 0.593, respectively). Conclusions: In high‐risk women with a sonographic short CL, placement of a modified Wurm cervical cerclage is associated with a lower rate of preterm birth < 32 weeks compared with McDonald cervical cerclage. Further research in larger cohorts is needed to confirm this finding and to determine if this technique reduces the preterm birth rate after elective cervical cerclage without CL shortening. © 2025 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
- Open Access
- 25 January 2024
- Published by Elsevier in American Journal of Obstetrics & Gynecology MFM
- Vol. 6 (3) , 101298
Prediction of spontaneous preterm birth in women with previous full dilatation cesarean delivery
- 25 January 2024
- Published by Elsevier in American Journal of Obstetrics & Gynecology MFM
- Vol. 6 (3) , 101298
Open AccessPrediction of spontaneous preterm birth in women with previous full dilatation cesarean delivery
- Open Access
- 1 September 2022
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 60 (3) , 396-403
Reproducibility of assessment of full‐dilatation Cesarean section scar in women undergoing second‐trimester screening for preterm birth
Objective: To assess the reproducibility of a standardized method of measuring the Cesarean section (CS) scar, CS scar niche and their position relative to the internal os of the uterine cervix by transvaginal ultrasound in pregnant women with a previous full‐dilatation CS.Methods: This was a prospective, single‐center reproducibility study on women with a singleton pregnancy and a previous full‐dilatation CS who underwent transvaginal ultrasound assessment of cervical length and CS scar characteristics at 14–24 weeks' gestation. The CS scar was identified as a hypoechogenic linear discontinuity of the myometrium at the anterior wall of the lower uterine segment or cervix. The CS scar niche was identified as an indentation at the site of the scar with a depth of at least 2 mm. The CS scar position was evaluated by measuring the distance to the internal cervical os. CS scar niche parameters, including its length, depth, width, and residual and adjacent myometrial thickness, were assessed in the sagittal and transverse planes. Qualitative reproducibility was assessed by agreement regarding visibility of the CS scar and niche. Quantitative reproducibility of CS scar measurements was assessed using three sets of images: (1) real‐time two‐dimensional (2D) images (real‐time acquisition and caliper placement on 2D images by two operators), (2) offline 2D still images (offline caliper placement by two operators on stored 2D images acquired by one operator) and (3) three‐dimensional (3D) volume images (volume manipulation and caliper placement on 2D images extracted by two operators). Agreement on CS scar visibility and the presence of a niche was analyzed using kappa coefficients. Intraobserver and interobserver reproducibility of quantitative measurements was assessed using Bland–Altman plots.Results: To achieve the desired statistical power, 72 women were recruited. The CS scar was visualized in > 80% of images. Interobserver agreement for scar visualization and presence of a niche in real‐time 2D images was excellent (kappa coefficients of 0.84 and 0.85, respectively). Overall, reproducibility was higher for real‐time 2D and offline 2D still images than for 3D volume images. The 95% limits of agreement (LOA) for intraobserver reproducibility were between ± 1.1 and ± 3.6 mm for all sets of images; the 95% LOA for interobserver reproducibility were between ± 2.0 and ± 6.3 mm. Measurement of the distance from the CS scar to the internal cervical os was the most reproducible 2D measurement (intraobserver and interobserver 95% LOA within ± 1.6 and ± 2.7 mm, respectively). Overall, niche measurements were the least reproducible measurements (intraobserver 95% LOA between ± 1.6 and ± 3.6 mm; interobserver 95% LOA between ± 3.1 and ± 6.3 mm). There was no consistent difference between measurements obtained by reacquisition of 2D images (planes obtained twice and caliper placed), caliper placement on 2D stored images or volume manipulation (planes obtained twice and caliper placed).Conclusions: The CS scar position and scar niche in pregnant women with a previous full‐dilatation CS can be assessed in the second trimester of a subsequent pregnancy using either 2D or 3D volume ultrasound imaging with a high level of reproducibility. Overall, the most reproducible CS scar parameter is the distance from the CS scar to the internal cervical os. The method proposed in this study should enable clinicians to assess the CS scar reliably and may help predict pregnancy outcome. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
- 1 September 2022
- Published by Wiley in Ultrasound in Obstetrics & Gynecology
- Vol. 60 (3) , 396-403
Open AccessReproducibility of assessment of full‐dilatation Cesarean section scar in women undergoing second‐trimester screening for preterm birth
Objective: To assess the reproducibility of a standardized method of measuring the Cesarean section (CS) scar, CS scar niche and their position relative to the internal os of the uterine cervix by transvaginal ultrasound in pregnant women with a previous full‐dilatation CS.Methods: This was a prospective, single‐center reproducibility study on women with a singleton pregnancy and a previous full‐dilatation CS who underwent transvaginal ultrasound assessment of cervical length and CS scar characteristics at 14–24 weeks' gestation. The CS scar was identified as a hypoechogenic linear discontinuity of the myometrium at the anterior wall of the lower uterine segment or cervix. The CS scar niche was identified as an indentation at the site of the scar with a depth of at least 2 mm. The CS scar position was evaluated by measuring the distance to the internal cervical os. CS scar niche parameters, including its length, depth, width, and residual and adjacent myometrial thickness, were assessed in the sagittal and transverse planes. Qualitative reproducibility was assessed by agreement regarding visibility of the CS scar and niche. Quantitative reproducibility of CS scar measurements was assessed using three sets of images: (1) real‐time two‐dimensional (2D) images (real‐time acquisition and caliper placement on 2D images by two operators), (2) offline 2D still images (offline caliper placement by two operators on stored 2D images acquired by one operator) and (3) three‐dimensional (3D) volume images (volume manipulation and caliper placement on 2D images extracted by two operators). Agreement on CS scar visibility and the presence of a niche was analyzed using kappa coefficients. Intraobserver and interobserver reproducibility of quantitative measurements was assessed using Bland–Altman plots.Results: To achieve the desired statistical power, 72 women were recruited. The CS scar was visualized in > 80% of images. Interobserver agreement for scar visualization and presence of a niche in real‐time 2D images was excellent (kappa coefficients of 0.84 and 0.85, respectively). Overall, reproducibility was higher for real‐time 2D and offline 2D still images than for 3D volume images. The 95% limits of agreement (LOA) for intraobserver reproducibility were between ± 1.1 and ± 3.6 mm for all sets of images; the 95% LOA for interobserver reproducibility were between ± 2.0 and ± 6.3 mm. Measurement of the distance from the CS scar to the internal cervical os was the most reproducible 2D measurement (intraobserver and interobserver 95% LOA within ± 1.6 and ± 2.7 mm, respectively). Overall, niche measurements were the least reproducible measurements (intraobserver 95% LOA between ± 1.6 and ± 3.6 mm; interobserver 95% LOA between ± 3.1 and ± 6.3 mm). There was no consistent difference between measurements obtained by reacquisition of 2D images (planes obtained twice and caliper placed), caliper placement on 2D stored images or volume manipulation (planes obtained twice and caliper placed).Conclusions: The CS scar position and scar niche in pregnant women with a previous full‐dilatation CS can be assessed in the second trimester of a subsequent pregnancy using either 2D or 3D volume ultrasound imaging with a high level of reproducibility. Overall, the most reproducible CS scar parameter is the distance from the CS scar to the internal cervical os. The method proposed in this study should enable clinicians to assess the CS scar reliably and may help predict pregnancy outcome. © 2022 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.